You are on page 1of 4

Contact

Mining cables
Phone: +49 (0) 2166 27 2326
frontoffice.mg@nexans.com

POWERMINETM (N)TMCGEH3S 6/10 kV

Trailing cables

Description
Application
POWERMINE® (N)TMCGEH3S was developed for use in open pit mines for
operation under difficult requirements.
This polyurethane sheathed version - with optimized wall thicknesses - can be
used for laying along conveyor belts in open pit mines, on stackers/reclaimers
e.g. in coal bunker, on shiftable belt conveyor systems, on spreaders and auxiliary
equipment like hopper cars, belt wagons or trippers, on material handling
equipment.
Design
Power Conductors
Conductor: Flexible, stranded, tinned annealed copper in accordance with DIN
VDE 0295 / IEC 60228 class 5.
Insulation: triple extruded consisting of: Standards
• Inner semi-conductive stress control layer International Nexans specification
• Elastomeric insulation of dielectric and thermal high graded, ozone-resistant National DIN VDE 0298 part 4;
EPR compound acc. to DIN VDE 0207 part 20 DIN VDE 0298 part 3
• Outer semi-conductive insulation, easy-strip (thermo-strip)
Shield: Mixed braid with tinned copper wires and synthetic threads Colour code:
black, white and red
Ground conductors
Flexible, stranded, tinned, annealed bare, copper
Ground check conductor
Conductor: Flexible, stranded, tinned, annealed copper class 5
Insulation: Hytrel colour: yellow
Cabling
The three phase conductors are stranded with two groundings and the ground
check conductor in the interstices with a left hand lay.
Jacket
TPU, abrasion and impact resistant, good elastic recovery, tear and kick-resistant,
oil and grease resistant, hydrolytic stable, colour: orange,
Inkjet marking:
POWERMINE (N)TMCGEH3S 3x120+2x50E+1x10P 6/10 KV year I NEXANS I

Flame Oil U.V Weather RoHS Max.conductor Ambient static Ambient dynamic
retardant resistance resistance resistance conform temp.in service op. temp operating temperature,
IEC EN Yes Very good Yes 90 °C -40 .. 80 °C range
60332-1-2 60811-2-1 -30 .. 80 °C

Version 1.2 Generated 7/12/16 - http://www.nexans.de Page 1 / 4


All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
Mining cables
Phone: +49 (0) 2166 27 2326
frontoffice.mg@nexans.com

POWERMINETM (N)TMCGEH3S 6/10 kV

Characteristics
Construction characteristics
Sheath colour Orange
Conductor material Plain annealed copper
Insulating material EPR
Outer sheath Polyurethane-compound TPU
Mechanical characteristics
Abrasion resistance High
Maximum tensile strength static 15 N/mm2
Maximum tensile strength dynamic 25 N/mm2
Tear resistance High
Usage characteristics
Field of application Open cast
Flame retardant IEC 60332-1-2
Oil resistance EN 60811-2-1
Ozone resistance Yes
U.V resistance Yes
Weather resistance Very good
RoHS conform Yes
Silicon free Yes
Limit surface temperature, flexible application -30 .. 80 °C
Max. conductor temperature in service 90 °C
Ambient static operating temperature, range -40 .. 80 °C
Short-circuit max. conductor temperature 250 °C
Moisture resistance Yes
Minimum bending radius, static (XD) 4
Ambient dynamic operating temperature, range -30 .. 80 °C
Min. drumcore radius. Approx. 8 (xD)

Product List =Make to order, =In stock


Nexans Construction Cable Max. outer diam. Approx. weight (kg/ Rated Voltage Uo/U
ref. type flexibility (mm) km) (Um)
71303253 3x35+3x25/3 Very flexible 46.0 2800 6 / 10 (12) kV
71303254 3x50+3x25/3 Very flexible 49.0 3400 6 / 10 (12) kV
71303255 3x70+3x35/3 Very flexible 53.0 4300 6 / 10 (12) kV
71303286 3x95+3x50/3 Very flexible 58.0 5400 6 / 10 (12) kV
= Make to order, = In stock

Flame Oil U.V Weather RoHS Max.conductor Ambient static Ambient dynamic
retardant resistance resistance resistance conform temp.in service op. temp operating temperature,
IEC EN Yes Very good Yes 90 °C -40 .. 80 °C range
60332-1-2 60811-2-1 -30 .. 80 °C

Version 1.2 Generated 7/12/16 - http://www.nexans.de Page 2 / 4


All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
Mining cables
Phone: +49 (0) 2166 27 2326
frontoffice.mg@nexans.com

POWERMINETM (N)TMCGEH3S 6/10 kV


Nexans Construction Cable Max. outer diam. Approx. weight (kg/ Rated Voltage Uo/U
ref. type flexibility (mm) km) (Um)
71303285 3x120+3x70/3 Very flexible 61.0 6400 6 / 10 (12) kV
71303256 3x150+3x70/3 Very flexible 67.0 7650 6 / 10 (12) kV
71304270 3x185+3x95/3 Very flexible 71.0 9000 6 / 10 (12) kV
71303257 3x240+3x120/3 Very flexible 76.0 11400 6 / 10 (12) kV
= Make to order, = In stock

Electrical data
Current-carrying capacity

Cross-section
[mm²] [A]
35 162
50 202
70 250
95 301
120 352
185 461
Current-carrying capacity in ampere [A] at 30° C ambient temperature
acc DIN VDE 0298 on ground
Short circuit Current-carrying capacity
(80 - 250° C /Ithr = 149 A/mm²) in kA
Ithz = Ithr x (tkr/tk)^0,5

Cross-section
1s (tkr) 0.5 s (tk)
[mm²]
35 4.5 6.3
50 7.5 10.5
70 10.4 14.7
95 14.1 20.0
120 15.4 21.7
185 23.7 33.5

Flame Oil U.V Weather RoHS Max.conductor Ambient static Ambient dynamic
retardant resistance resistance resistance conform temp.in service op. temp operating temperature,
IEC EN Yes Very good Yes 90 °C -40 .. 80 °C range
60332-1-2 60811-2-1 -30 .. 80 °C

Version 1.2 Generated 7/12/16 - http://www.nexans.de Page 3 / 4


All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
Mining cables
Phone: +49 (0) 2166 27 2326
frontoffice.mg@nexans.com

POWERMINETM (N)TMCGEH3S 6/10 kV


letter code
Letter code Explanation
(N) in line with DIN VDE 0250 part 813
T Trailing cable
M single sheath version
CGE mixed braid over each conductor
H Hytrel® Thermoplastic Elastomer isolation over pilot wire
3S NEXANS code for PUR sheath

Resistance

Max. conductor Outer-Ø Weight


Cross-section resistance at 20 °C min. max. appr.
Type - No.: [mm²] [W/km] [mm] [mm] [kg/km]
3x35 0.565 43 46 2900
3x50 0.393 47 50 3700
3x70 0.277 49 52 4300
3x95 0.210 53 56 4900
3x120 0.164 58 62 6100
3x185 0.108 66 70 8500
Rated voltage: 6/10 kV
Test voltage: 17 kV AC

Flame Oil U.V Weather RoHS Max.conductor Ambient static Ambient dynamic
retardant resistance resistance resistance conform temp.in service op. temp operating temperature,
IEC EN Yes Very good Yes 90 °C -40 .. 80 °C range
60332-1-2 60811-2-1 -30 .. 80 °C

Version 1.2 Generated 7/12/16 - http://www.nexans.de Page 4 / 4


All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.

You might also like