Professional Documents
Culture Documents
www.daliform.com
Disposable formwork
for two-way voided slabs
in reinforced concrete
cast on site
MADE IN ITALY
KEY:
Formwork
Utility passage
Foundations
Certifications
SWITCHBOARD
Telephone +39 0422 2083
3
Advantages
Traditional one way slab System optimised with U-Boot® Beton
2 1
3 2
3
4
6 6
7
8
10
11 11 12
12
4
Real advantages
We are incorrectly led to estimate the advantage of a slab lightened with U-Boot® Beton limiting it to a mere comparison between
savings in concrete and the cost of the formwork on the level of the slabs only. In this way however, as the analysis is immediate
and intuitive, it does not account for the various economic, practical and operational advantages provided with U-Boot® Beton
for the entire structure: less use of iron in the slabs, pillars and foundation up to a total of 15% (also in the case of variants); less
concrete is used not only for the slabs but also for the columns and foundations; there are antiseismic advantages connected to
reduced building weight; slimmer pillars and foundations, lower costs related to excavation for foundations; the arrangement, also
irregularly if needed, of the pillars to reflect the architectural freedom of the structure. Reduction of work and overhead transfer of
the formworks; advantages in on-site logistics.
5
Applications
U-Boot® Beton is used in all applications that require a structural plate
together with the need to use less concrete and therefore for a lighter
structure.
U-Boot® Beton is the ideal solution for creating slabs with a large span
and/or great load-bearing capacity: it is particularly suited for structures
that require considerable open spaces, such as executive, commercial
and industrial buildings as well as public, civil and residential structures.
It makes it possible to more irregularly distribute the pillars, as beams do
not need to be created.
In the case of yards that are difficult to access or restructuring work,
U-Boot® Beton, due to its stackability, modularity, lightness and
manoeuvrability, can be used to make horizontal structures without the
help of handling and hoisting equipment.
With U-Boot® Beton also foundation rafters can be created with a larger
thickness with a reduced amount of concrete.
6
Photo gallery
7
Range Installation Application examples: rafts
Among the various foundation types, rafts are one of the most well known.
REINFORCEMENTS
LOWER REINFORCEMENT
TRADITIONAL SHUTTERING REINFORCEMENTS FORMWORK They are used above all in ground conditions with little bearing capacity,
IN WOOD OR METAL
SIDE SIDE or with poor quality soil, large thicknesses must be used which increases
SHUTTERING SHUTTERING the construction cost.
Thanks to the use of U-Boot® Beton lightened rafts can be created with
SPACER SPACER
PILLAR PILLAR the same performance but at a considerably lower cost.
PROP PROP Once drown in the concrete casting, U-Boot® Beton forms the structure
single single single single single double single double single single single double single double double double double double just like double two fulldouble slabs, with a variable
double thickness,double
double connecteddouble by a double double double double double double double double double double double double double double double double double
52 perpendicular beam gridwork to form a bidirectional static honeycomb
H cm 10 13 16 18 20 20 22 surface23of the slab24to be cast 25
1 The entire 26
on site is shuttered 2 26
The U-Boot®28 28 are positioned
Beton formworks 29 30 the lateral31
using 32 plate. 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 56
Working dimensions cm 52 x 52 52 x 52 52 x 52 52 x 52 52 x 52 52 x 52 with 52wood
x 52 deckings
52 x 52 (or similar
52 x 52 systems),52 x 52then the 52 xlower
52 52spacers
x 52 joints
52 x to
52 place them
52 x 52at the desired
52 x 52 centre52distance
x52 that
52 x52 52 x52 For this 52 xconcrete
52 bed,
52 x 52 the distribution
52 x 52 of weights
52 x 52 due52tox 52hight inertia
52 x 52 is 52 x 52 52 x 52 52 x 52 52 x 52 52 x 52 52 x 52 52 x 52 52 x 52 52 x 52 52 x 52 52 x 52 52 x 52 52 x 52 52 x 52 52 x 52 52 x 52 52 x 52
reinforconcrete bars are positioned in two mutually perpendicular will determine the beam width. Thanks to the conic elevator 32
rationalised
33
in order 34
to permit maximum
35
stiff
36
ness and lightness
37
for38
the 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 56
52 Height H cm 10 13 16 18 20 20 22 23 24 25 26 26 28 28 29 30 31
directions according to the design and the lattice for the upper foot, theU-Boot® Beton formworks will be lifted from the surface, structure with a minimum amount of concrete, which makes it possible
Foot height p cm 0-5-6-7-8-9-10 0-5-6-7-8-9-10 0-5-6-7-8-9-10 0-5-6-7-8-9-10-12 0-5-6-7-8-9-10 0-5-6-7-8-9-10-15 reinforconcrete
0-5-6-7-8-9-10-12 0-5-6-7-8-9-10-15
is arranged. 0-5-6-7-8-9-10-12 0-5-6-7-8-9-10 0-5-6-7-8-9-10-12 0-5-6-7-8-9-10-15
making it0-5-6-7-8-9-10-17
possible for0-5-6-7-8-9-10-15
the lower slab 0-5-6-7-8-9-10-15 0-5-6-7-8-9-10-15
to be formed. If double0-5-6-7-8-9-10-15
or 0-5-6-7-8-9-10-15 0-5-6-7-8-9-10-15where
to eliminate, 0-5-6-7-8-9-10-15
possible,0-5-6-7-8-9-10-15
the foundation 0-5-6-7-8-9-10-12-15
piles. 0-5-6-7-8-9-10-15 0-5-6-7-8-9-10-12-15 0-5-6-7-8-9-10-15 0-5-6-7-8-9-10-12 0-5-6-7-8-9-10-15 0-5-6-7-8-9-10-12 0-5-6-7-8-9-10-12 0-5-6-7-8-9-10-12 0-5-6-7-8-9-10 0-5-6-7-8-9-10-12 0-5-6-7-8-9-10-12 0-5-6-7-8-9-10-12 0-5-6-7-8-9-10-12 0-5-6-7-8-9-10-12 0-5-6-7-8-9-10 0-5-6-7-8-9-10-12 0-5-6-7-8-9-10 0-5-6-7-8-9-10-12 0-5-6-7-8-9-10-17
52 Height H cm 10 13 14 16 18 20 20 22 23 24 24 26 26 27 28 28 29 30 30 31 32 33 34 35 36 37
Purpose: 38 39 40 41 42 43 44 46 48 50 52 54 56 58 60
Foot height p cm 0-5-6-7-8-9...15 0-5-6-7-8-9...15 0-5-6-7-8-9...15 0-5-6-7-8-9...15 0-5-6-7-8-9...15 0-5-6-7-8-9...15 0-5-6-7-8-9...20 0-5-6-7-8-9...15 0-5-6-7-8-9...20 0-5-6-7-8-9...15 0-5-6-7-8-9...20 0-5-6-7-8-9...15 0-5-6-7-8-9...20 0-5-6-7-8-9...20 0-5-6-7-8-9...15 0-5-6-7-8-9...20 0-5-6-7-8-9...20 0-5-6-7-8-9...15 0-5-6-7-8-9...20 0-5-6-7-8-9...20 0-5-6-7-8-9...20 0-5-6-7-8-9...20 0-5-6-7-8-9...20 0-5-6-7-8-9...20 0-5-6-7-8-9...20 creation
0-5-6-7-8-9...20of very rigid rafts,
0-5-6-7-8-9...20 minimising
0-5-6-7-8-9...20 the
0-5-6-7-8-9...20 0-5-6-7-8-9...20 0-5-6-7-8-9...20 0-5-6-7-8-9...20 0-5-6-7-8-9...20 0-5-6-7-8-9...20 0-5-6-7-8-9...20 0-5-6-7-8-9...20 0-5-6-7-8-9...20 0-5-6-7-8-9...20 0-5-6-7-8-9...20 0-5-6-7-8-9...20 0-5-6-7-8-9...20
5 Once suitably set, the casting can be restarted from the starting 6 Once the structure has hardened, the formwork can be removed. UPPER quantity of concrete and the foundation
Spacer height d cm 1 1 1 1 1 1
point, 1completely burying
1 1
the U-Boot® Beton.1 1
The casting is 1
The surface is1 smooth in correspondence
1 1 1
of the soffit. 1 1 1 FORMWORK
1 1 1 1 REINFORCEMENT
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
weight in the case of inconsistent ground
d Weight per piece kg 1,579 1,730 1,650 1,784 1,860 1,806 then levelled and smoothed
1,947 in a traditional manner.
2,044 2,195 2,271 2,250 10 LOWER surfaces.
H
Piece volume m3 0,0220 0,0290 0,0310 0,0350 0,0387 0,0427 0,0440 0,0465 0,0510 0,0503 0,0530 0,0540 Comply0,0581*
with the requirements
0,0600 for concrete.
0,0576 0,0608 0,0641 0,0611
48
0,0647 0,0678 0,0701* 0,0718 0,0738* 0,0755 TRESTLEWORK
0,0778* 0,0793 0,0815* 0,0830 0,0854* 0,0866 0,0892* 0,0901 0,0930* 0,0968* 0,1006* 0,1043* 0,1080* 0,1116* 0,1152* 0,1187 0,1222
p Advantages:
Pallet dimensions cm 110x110x243 110x110x248 110x110x249 110x110x250 110x110x254 110x110x249 110x110x250 110x110x249 110x110x250 110x110x250 110x110x250 110x110x247 110x110x250 110x110x250 110x110x248 110x110x250 110x110x250 110x110x251 110x110x250 110x110x250 110x110x250 110x110x250 110x110x250 110x110x250 110x110x250 110x110x250 110x110x250 110x110x250 110x110x250 110x110x250 110x110x250 110x110x250 110x110x250 110x110x250 110x110x250 110x110x250 110x110x250 110x110x250 110x110x250 110x110x250 110x110x250
SINGLE
10 • lightens the structure
d Pallet pieces pcs/PAL 460 460 460 460 460 440 440 440 420 420 420 • less concrete use
LOWER • structure stiffness
Pallet weight kg/PAL 739 809 846 834 869 808 870 912 935 967 958
H REINFORCEMENT • decrease on stress on the ground
Composed of U-Boot UP cm 10 13 14 13 - 16 14 18 16 20 18 16 - 22 20 24 - 18 22 18 - 20 - 26 24 20-22-28 26 20-22-24-30 28 22 - 24 - 26 30 22-24-26-28 24-26-28-30 24-26-28-30 26 - 28 - 30 26 - 28 - 30 28 - 30 28 - 30 30 30
d 20 52 20
NATURAL GROUND • elimination of foundation piles
p 13 - 10
DOUBLE Composed of U-Boot DOWN cm 10 10 10 13 10 13 10 13 16 - 10 13 10 - 16 13 18 - 16 - 10 13 18-16-10 13 20-18-16-10 13 20 - 18 - 16 13 22-20-18-16 22-20-18-16 24-22-20-18 24 - 22 - 20 26 - 24 - 22 26 - 24 28 - 26 28 30
*Volume related to one possible combination “UP + DOWN”.
Photographic details of the complete sequence of positioning the scaffolding, positioning the U-Boot® Beton, reinforconcrete of the structure to be performed on site, casting
and final smoothing.
9 16 17 12
U-Boot® Beton parameter and consumption table
Formwork Base Height Feet Spacers Joist width Joist centre U-Boot Concrete saving Concrete
H p d distance incidence consumption
cm cm cm cm cm cm pcs/m2 m3/pcs m3/m2 m3/m2
10 62 2,60 0,055 0,045
12 64 2,44 0,052 0,048
u - 10 52 x 52 10 0-5-6-7-8-9-10...15 1 14 66 2,30 0,0213 0,049 0,051
16 68 2,16 0,046 0,054
18 70 2,04 0,043 0,057
20 72 1,93 0,041 0,059
10 62 2,60 0,073 0,057
12 64 2,44 0,068 0,062
u - 13 52 x 52 13 0-5-6-7-8-9-10...15 1 14 66 2,30 0,0280 0,064 0,066
16 68 2,16 0,060 0,070
18 70 2,04 0,057 0,073
20 72 1,93 0,054 0,076
10 62 2,60 0,091 0,069
12 64 2,44 0,085 0,075
u - 16 52 x 52 16 0-5-6-7-8-9-10...15 1 14 66 2,30 0,0350 0,081 0,080
16 68 2,16 0,076 0,084
18 70 2,04 0,071 0,089
20 72 1,93 0,068 0,092
10 62 2,60 0,112 0,088
12 64 2,44 0,105 0,095
u - 20 52 x 52 20 0-5-6-7-8-9-10...15 1 14 66 2,30 0,0430 0,099 0,101
16 68 2,16 0,093 0,107
18 70 2,04 0,088 0,112
20 72 1,93 0,083 0,117
10 62 2,60 0,128 0,102
12 64 2,44 0,120 0,110
u - 23* 52 x 52 23 0-5-6-7-8-9-10...15 1 14 66 2,30 0,0493 0,113 0,117
16 68 2,16 0,106 0,124
18 70 2,04 0,101 0,129
20 72 1,93 0,095 0,135
10 62 2,60 0,133 0,107
12 64 2,44 0,125 0,115
u - 24 52 x 52 24 0-5-6-7-8-9-10...15 1 14 66 2,30 0,0513 0,118 0,122
16 68 2,16 0,111 0,129
18 70 2,04 0,105 0,135
20 72 1,93 0,099 0,141
10 62 2,60 0,146 0,114
12 64 2,44 0,137 0,123
u - 26* 52 x 52 26 0-5-6-7-8-9-10...15 1 14 66 2,30 0,0563 0,129 0,131
16 68 2,16 0,122 0,138
18 70 2,04 0,115 0,145
20 72 1,93 0,109 0,151
10 62 2,60 0,146 0,134
12 64 2,44 0,137 0,143
u - 28 52 x 52 28 0-5-6-7-8-9-10...15 1 14 66 2,30 0,0562 0,129 0,151
16 68 2,16 0,121 0,159
18 70 2,04 0,115 0,165
20 72 1,93 0,108 0,172
10 62 2,60 0,164 0,126
12 64 2,44 0,154 0,136
u - 29* 52 x 52 29 0-5-6-7-8-9-10...15 1 14 66 2,30 0,0630 0,145 0,145
16 68 2,16 0,136 0,154
18 70 2,04 0,129 0,161
20 72 1,93 0,122 0,168
10 62 2,60 0,182 0,138
12 64 2,44 0,171 0,149
u - 32* 52 x 52 32 0-5-6-7-8-9-10...15 1 14 66 2,30 0,0700 0,161 0,159
16 68 2,16 0,151 0,169
18 70 2,04 0,143 0,177
20 72 1,93 0,135 0,185
10 62 2,60 0,185 0,145
12 64 2,44 0,173 0,157
u - 33* 52 x 52 33 0-5-6-7-8-9-10...15 1 14 66 2,30 0,0710 0,163 0,167
16 68 2,16 0,153 0,177
18 70 2,04 0,145 0,185
20 72 1,93 0,137 0,193
* Composed of two single elements
» The table of parameters and consumptions of the full range of U-Boot® Beton elements is available and downloadable on website www.daliform.com
8
Formwork Base Height Feet Spacers Joist width Joist centre U-Boot Concrete saving Concrete
H p d distance incidence consumption
cm cm cm cm cm cm pcs/m2 m3/pcs m3/m2 m3/m2
» The table of parameters and consumptions of the full range of U-Boot® Beton elements is available and downloadable on website www.daliform.com
Project Treviso Maggiore - Arch. Mario Botta “The Quad” Business Towers in Malta
13
Characteristics of a U-Boot® Beton slab and comparison with a full slab
S1
S1 H
H
S2 S2
Modelling of a shell+solid undeformed structure. Modelling of a solid deformed structure and Modelling of a frame - undeformed structure
illustration of stress.
Modelling of a frame illustrating torque. Modelling of a shell - undeformed structure Modelling of a shell illustrating torque.
14
Beams in the slab thickness - The spacer joint
The U-Boot® Beton lightened plate slab has a perpendicular beam gridwork of the same
thickness as the slab that transfers all stresses directly to the pillars around which it will
suffice to leave a full zone of variable dimensions based on the shearing forces. Beam
dimensioning and their perfect implementation on site depends on the orderly and precise
layout of the lightening elements during installation but especially during casting.
Correct positioning of the U-Boot® Beton is guaranteed by an effective rigid spacer joint
with graduated scale with which the desired width of the beams is quickly determined. The
joint fits into the top of the formwork inside notches housing the fixing elements.
Thanks to this system, the connection of the formworks is simple and quick because it is not
hindered by the beam reinforcements.
The rigid interconnection ensures perfect geometric compliance with the design as well as
with the bearing capacity of the formworks when casting under the pressure of the concrete,
the weight of the operators and equipment.
Fig. 1
Advantages:
40
40
24
25
GRECA Ø10/15 cm
L=VAR (SEE. PLAN)
• no lowered structures (beams)
• bidirectional structure
15
Installation
REINFORCEMENTS
TRADITIONAL SHUTTERING REINFORCEMENTS FORMWORK
LOWER REINFORCEMENT
IN WOOD OR METAL
SIDE SIDE
SHUTTERING SHUTTERING
SPACER SPACER
PILLAR PILLAR
PROP PROP
1 The entire surface of the slab to be cast on site is shuttered 2 The U-Boot® Beton formworks are positioned using the lateral
with wood deckings (or similar systems), then the lower spacers joints to place them at the desired centre distance that
reinforconcrete bars are positioned in two mutually perpendicular will determine the beam width. Thanks to the conic elevator
directions according to the design and the lattice for the upper foot, theU-Boot® Beton formworks will be lifted from the surface,
reinforconcrete is arranged. making it possible for the lower slab to be formed. If double or
triple elements are used, these elements must first be assembled,
which will be supplied on distinct pallets in the yard.
SPACER SPACER
PILLAR PILLAR
PROP PROP
3 The positioning of the reinforconcretes is completed by placing 4 The concrete casting must be performed in two phases to prevent
above the U-Boot® Beton formwork the upper bars in the two the floatation of the formworks: an initial layer will be cast to fill
directions as well as the reinforcement for shear and punching a thickness equal to the height of the elevator foot. Casting will
where necessary, according to the design. continue for this first portion of the slab until the concrete starts to
set and become semi fluid.
SIDE
SHUTTERING
PILLAR PILLAR
PROP BACKPROP
5 Once suitably set, the casting can be restarted from the starting 6 Once the structure has hardened, the formwork can be removed.
point, completely burying the U-Boot® Beton. The casting is The surface is smooth in correspondence of the soffit.
then levelled and smoothed in a traditional manner.
Comply with the requirements for concrete.
Photographic details of the complete sequence of positioning the scaffolding, positioning the U-Boot® Beton, reinforconcrete of the structure to be performed on site, casting
and final smoothing.
16
Application examples: rafts
Among the various foundation types, rafts are one of the most well known.
They are used above all in ground conditions with little bearing capacity,
or with poor quality soil, large thicknesses must be used which increases
the construction cost.
Thanks to the use of U-Boot® Beton lightened rafts can be created with
the same performance but at a considerably lower cost.
Once drown in the concrete casting, U-Boot® Beton forms the structure
just like two full slabs, with a variable thickness, connected by a
perpendicular beam gridwork to form a bidirectional static honeycomb
plate.
For this concrete bed, the distribution of weights due to hight inertia is
rationalised in order to permit maximum stiffness and lightness for the
structure with a minimum amount of concrete, which makes it possible
to eliminate, where possible, the foundation piles.
pillar pillar
foundation
piles
Purpose:
creation of very rigid rafts, minimising the
FORMWORK UPPER REINFORCEMENT quantity of concrete and the foundation
weight in the case of inconsistent ground
10 LOWER surfaces.
TRESTLEWORK
48
Advantages:
10 • lightens the structure
• less concrete use
LOWER • structure stiffness
REINFORCEMENT • decrease on stress on the ground
20 52 20
NATURAL GROUND • elimination of foundation piles
17
U-Boot® Beton: excellence
The quality of the used mixture, the innovative shape, the thicknesses and dimensions of the product, the fire safety and strict working
techniques make it a product of excellence.
U-Boot® Beton, is not subject to deformations, either during or after the casting, either due to the weight of the concrete or the dynamic
effect connected to the work operations: it is able to support before casting the workers and fresh concrete, the pressure created during
the compression and vibration of the casting, the weight of people, reinforconcretes and equipment guaranteeing conditions of safety,
and lack of deformations. Furthermore, the safety of the lateral spacer guarantees its perfect positioning and respect of the geometry of
the beams under the pressure of the concrete.
Numerous national and international Product and System Certifications have been received that prove not only product quality, but also
the validity of the constructive solutions and the applications in the building industry
All of this, together with the advantages mentioned below, make U-Boot® Beton the product of reference for operators and professionals.
18
Environmental compatibility
Daliform Group has again demonstrated to be extremely precise with regard to respecting
health and the environment having been the first to obtain Environmental Compatibility
Certification (CCA) for its products.
This certificate is very important for U-Boot® Beton because it demonstrates: the lack
of dangerous substances in its composition (even if recycled materials are used); the
lack of emissivity of toxic substances during the various phases of the product's life and
operating cycle, which benefits the health of the intermediate users (production and
installation personnel) as well as final users (people living in the building) as well as the
environment in general.
Certifications
• Fire Resistance Certificate REI 180 for U-Boot® Beton issued by the CSI institute in
Bollate (MI).
• Certification of a Load Test on a sample with U-Boot® Beton issued by the University
of Darmstadt.
• Acoustic test according to the standard UNI EN ISO 140-6 - Measurement of acoustic
insulation in buildings and building elements; Laboratory measurements of the
insulation footstep noise issued by the Istituto Giordano di Gatteo (FC).
• Acoustic test according to the standard UNI EN ISO 140-3 - Measurement of acoustic
insulation in buildings; Laboratory measurements of the insulation of air-borne noise
from building elements issued by the Istituto Giordano di Gatteo (FC).
• Loading and breaking test certified by the University of Padua.
• Environmental Compatibility Certification (CCA).
19
Specifications
U-BOOT® BETON
Supply of lightening formwork U-Boot® Beton and its accessories, for the execution of a reinforced concrete slab, with a bidirectional
capacity, to be casted on suitable horizontal formwork (or on a prefabricated slab).
Total slab thickness is ______ cm lightened in compliance with the design, with recycled plastic elements such as U-Boot® Beton of
the Daliform Group Company, truncated-pyramid in shape with a crossed semi-cylindrical notch at the top to put reinforcement bars or
installations to be integrated in the casting. U-Boot® Beton has got plan dimensions equal to 52 x 52 cm and height equal to H ______
cm, with the four semi-circular notched corners at the base of which the conic elevator foot is created, in integral way, facing down, with
a height equal to H ______ cm, basing on the scaffolding to form the thickness of the intrados suitably reinforced with bidirectional
mesh of reinforcing bars in steel type B450C, with diameter and spacing adapted to the design stresses.
The supply includes positioning of the U-Boot® Beton modules with rigid spacer joints to form a link and thus create the perpendicular
ribs between the formworks according to the predefined thickness and ensure the perfect geometry and bearing capacity upon
casting, to be placed at the top of them inside the notches.
The supply and casting of the concrete (minimum resistance class equivalent to C25/30, consistency class Slump S4 or S5 and
diameter of the aggregates such to avoid “segregation” phenomena) is also included. The lower slab must be made, in a first phase,
by casting the concrete and vibrating it until it covers the entire U-Boot® Beton feet (max 4 cm above them in case of Double type
lightening). In a second phase, the completion casting will continue as soon as the first layer has lost fluidity (in this second phase a
class of concrete consistency other than the previous one is allowed).
The U-Boot® Beton modules, produced in ALAPLEN® CV30, must be safe to walk on and certified with a resistance characteristic
of 150 kg in the weakest point on an 8 x 8 cm footprint; they must not release any polluting substances and must have a Certificate
of Compliance with the environmental compatibility criteria (CCA) and be produced by a company using an Integrated Management
System (ISO 9001, ISO 14001, ISO 45001, SA 8000).
The final design of the voided slabs must have graphs and calculations provided by the Company supplying the U-Boot® Beton, which
must exhibit the product certificate approved by an EOTA member Body (European Organisation for Technical Approvals).
The Manufacturer must provide: the Technical and Safety Data Sheet of the product and as well as that of the granule used ALAPLEN®
CV30; a Certificate of acoustic behaviour that shows the raw minimum value of the sound insulation of the bare floor (Rw) equal to 56
dB, and a value of the noise level of footing of the bare floor (Ln,w) maximum of 82 dB verified on a lightened slab type of thickness equal
to 26 cm (5 + 16 + 5), issued by certified Third Parties.
With reference to fire regulations, the Manufacturer must provide fire behaviour test, issued by an accredited Body, which demonstrates
for a voided slab of 25 cm thickness (5 + 16 + 4) a fire resistance REI 180 with a design moment of at least 4880 daNm and minimum
concrete cover of 3 cm, and which also demonstrates that the behaviour of the U-Boot® Beton feet is similar to that of overpressure
relief valves, and therefore it is not necessary to provide suitable vents for overpressure (as, on the contrary, it is necessary for
lightening in polystyrene or similar materials). Moreover the Manufacturer will have to provide a detailed study, conducted by an EOTA
member accredited Body, of the fire behaviour of a lightened slab with elements in recycled plastic, executed on scaled samples from
which the isothermal temperature propagation curves inside the slab can be deduced.
In addition, the manufacturer shall provide, on request, appropriate certifications relating experimental test that proving the bi-
directional resistant mechanism of the system, namely its actual behaviour as a slab, and appropriate certifications relating to tests of
slab-column node, in order to provide the system’s ability to perform, in a seismic zone, its secondary system function supported to a
primary system of ductile bracings.
The cost for the creation of holes with the dimensions and sections foreseen by the architectural drawings is also included, the price also
includes and covers all costs for providing the finished work in a workmanlike manner; it does not include the supply and positioning
of the horizontal formwork that supports the slab and accessories, the steel reinforcements, which will be entered separately.
20
Specifications
21
Daliform Group technical office
FEASIBILITY STUDY
Predimensioning and optimisation of the structures, comparative and/or revised
proposals, material and manpower estimates, cost analysis.
Evaluation of forced ventilation in the case of cold rooms.
CALCULATION REPORT
Reports certifying the execution of Daliform Group constructive systems.
ON-SITE SUPPORT
If necessary, our technical staff can be present on-site to help the construction
company during the operational phase.
The technical consultancy is only valid for the Daliform Group construction systems.
To contact the technical office: Tel. +39 0422 2083 - tecnico@daliform.com
To obtain updated technical cards, support material, new photos and case studies, go to www.daliform.com
8,20/9,60 x 2,45
Tractor (8,20/9,60x2,45) 14/16
6,20 x 2,45
Trailer (6,20x2,45) 10
13,60 x 2,45
Semi-trailer (13,60x2,45) 22/23
The information contained in this catalogue could be changed. Please request updated informations from DALIFORM GROUP, which reserves the right to
make changes at any moment without notice. In consideration of recycled material, it is specified that there are tolerance margins caused by environmental
factors.
22
www.daliform.com
Rating di legalità: