GE Healthcare

Integrated Registration
for Universal Viewer
Multi-Modality Image Management.

In Radiology practice today, multiple complementary imaging


modalities are frequently relied on to image the same patient, as
each modality provides unique anatomical and physiological
• Load and register on the fly
information. 3D modalities such as CT and MRI provide information with drag and drop.
• Easy registration and fusion.
about the relationship of anomalous findings to surrounding • Automatic registration
structures and tissues. The Integrated Registration application propagation across series:
one-click access to pre-defined
provides you with the a streamlined workflow to combine and display protocols.
images from any two of the following major modalities CT, MR, PET, • Automatic, manual, and
landmark registration methods.
and X-ray angiography, aimed at improving your ability to provide • 2D, 3D, and hybrid capabilities.
more clinically relevant diagnostic information, and improving • Rigid and non-rigid
(deformable) registration.
surgical and treatment planning. • Lets you draw and save
contours as RTSS DICOM
objects.
• Optional definition of
anatomical regions of interest
Overview for optimization of registration
in this region.
Integrated Registration provides you
• Compatible with GE Advantage
with the capability to fuse and register
SIM MD and other standard
two volumetric acquisitions from either
treatment planning software.
the same or different acquisition
modalities. With it, you can easily
compare 3D anatomical images from
CT, MR with PET, and X-ray
angiography1 for a more
comprehensive analysis.

Visit us:
www.gehealthcare.com/aw/
applications/integrated-registration/
Features treatment efficacy. Intended Use
• Combines images from different • Define volume of interest in one Integrated Registration provides easy
modalities for enhanced volume model for automatic report to comparison of three-dimensional (3D)
definition. another model for subsequent use images from Computed Tomography
• Fuses functional and anatomical in Radiation Therapy (RT) planning.4 (CT), Magnetic Resonance Imaging
images. • Provide referring physicians with (MRI), Emission Tomography (PET or
• Provides access to Volume Viewer2 clearer, more detailed reports. SPECT5) and X-Ray Angiography
functions, including Multiplanar images (XA). To help physicians in
Reformat, slab and oblique Image Requirements diagnostic radiology or therapy
reformations, triple oblique easy Acquisition position and plane, slices planning, Integrated Registration
definition, volume rendering, 3D resolution, number, thickness, and allows 3D registration between
display, distance and Region of spacing may be different in the volumetric acquisitions that may
Interest (ROI) measurements,3 acquisition of the two exams to be come from the same acquisition
layout management, registered. modality or from different acquisition
segmentations, film, and save. modalities.
• Ability to save registered data as Each image set should meet basic
new DICOM series or as a requirements, however: Regulatory Compliance
Registration DICOM object • Field of view, matrix size, and This product complies with the
• Loads exams and series from CT, display center should be the same European Council Directive
MR, PET, or XA together for for all images inside one series 93/42/EEC Medical Device Directive
registration in the same session. • Orientation should be the same for as amended by European Council
• Offers a choice of four registration all images in the series Directive 2007/47/EC.
methods. • Series should include more than
• Draw and save contours as RTSS one image
1For XA modality series, Integrated

DICOM objects. Registration currently supports only 3D X-


• Tilted acquisitions are not Ray Angiography images (stored as CT
• Allows you to define one or more supported by mutual information Image Storage DICOM objects) acquired with
contours around relevant anatomy. based automatic algorithms; they GE Innova equipment and
• Ability to automatically bind several can be registered with manual, reconstructed with the Innova3DXR
MR axial series corresponding to application.
landmark, or automatic “matching 2Requires Volume Viewer key
sequential axial locations into a boundaries” registration methods. 3The ROI measurement works only on rigid
single series. This may be • Datasets used as reference and registered images, not on non-rigid
displayed as sagittal or coronal moving should have some registered images.
4Requires DICOM RT capability on RT
reformats. matching anatomical location. planning system
• Provides comparison of a current System Requirements 5SPECT modality partially supported in
exam with previous exams to  Centricity PACS 5.0 with Universal Universal Viewer
evaluate disease progression or Viewer, or Centricity IW-PACS 5.0
with Universal Viewer

© 2013 General Electric Company.


All rights reserved. Data subject to change.
GE and GE Monogram are trademarks of General Electric Company.
* Trademark of General Electric Company.
Integrated Registration
non-rigid registrations. Rigid registration also
benefits from regionally optimized registration
Feature Details using an ROI.
Multiple series acquired in the same exam (i.e. with
Loading the same frame of reference) are grouped together
Load multiple exams and series from CT, MR, PET, or and registration that is applied to one series of the
XA for registration in the same session. Within an group is automatically propagated to other series
open registration protocol session, you can easily of the same group by default. You can manually
add additional series using a simple drag and drop group or ungroup series if desired. Propagation will
method. You can also choose to have the then be applied to manually grouped series while
registration protocol run automatically at loading ungrouped series may be registered independent
or dynamic loading. Reference and Moving series of their original group. Use manual ungrouping
are preselected; however you can easily control specifically to independently register series of one
and adjust these selections. identical exam during which the patient has moved.
The Center, Reset, and Undo/Redo options
significantly improve productivity during the
registration process.

Registration
With Integrated Registration, you can employ four
rigid registration methods:
1. Automatic registration based on “mutual
information” and “matching boundaries” for CT,
MR, PET, or XA.
2. Automatic regional registration, which can be Quality Control
run by defining an ROI upon which the Two methods are made available to you with which
registration methods (listed in #1 above) are to validate the accuracy of the registration:
applied only within the designated boundaries. 1. Qualitatively by visually inspecting registration
3. Interactive manual registration, which, in real results using all available display modes (see
time, conveys translation and rotation made to Visualization below).
the alignment of one data set to the second 2. Quantitatively by defining pairs of common
data set. This method can be used with all landmarks on the two exams. This includes
modality pair combinations. calculation of the Maximal Error on a pair and
4. Landmark registration, which is based on the Root Mean Square (RMS) error on all pairs.
manual definition of common points between
the two data sets. This method can be used Visualization
with all modality pair combinations. Optimized screen layouts are provided which you
You can combine these four methods to achieve can customize to suit your needs.
optimal results. The methods allow registration of The common cursor, active by default, provides you
volumes with linear FOV rescaling and 6 degrees of with a triangulated display in which the cursor is
freedom (translation and rotation). positioned at the same geometrical coordinates in
Non-rigid automatic registration can be employed all views.
for CT to CT data sets only. The non-rigid You can apply dedicated display modes to fused
registration performed on CT series can then be views during your review:
propagated to any other MR, PET, or XA series. • Windows – An adjustable viewing window of the
Global registrations are possible for both rigid and

Integrated Registration -1
registered exam that can be moved anywhere
over the reference exam and shows the
corresponding part of the moving exam.

Create 2D, 3D fused, and hybrid 2D/3D fused views


with a simple drag and drop method. Save the layouts
you define for personalized display of registration
results.
• Tiles – The selected view is subdivided into four
tiles that meet at the position of the 3D cursor.
Two tiles display regions of the reference exam,
and two display the corresponding regions of the
moving exam.

Contours
With Integrated Registration, you can define one or
multiple contours around relevant anatomical
• Fused – The moving exam is overlaid on the
structures on the exam.
reference exam with an adjustable fusion
percentage.

To help define the area, the contour appears on all


exams as you draw it. You can draw the contour slice
• Inversed fused – The moving exam is displayed
by slice or on two non-contiguous slices with
over the reference exam in inverse linear grey
interpolation on slices in between.
levels with an adjustable fusion percentage.
You can modify or remove contours from a single slice
or from the entire exam. You can also save them in the
browser, linked with the corresponding exams in

Integrated Registration -2
DICOM RT Structure Set format for export to DICOM RT-
compatible planning systems.
Integrated Registration protocols also allow you to
define, save, and load RTSS objects.

Autobind MR Series
Integrated Registration gives you the capability to bind
several MR axial series acquired at sequential axial
locations into a single series. This series may then be Initiating a registration protocol is easy:
displayed as coronal or sagittal reformats. This is useful 1. Load a DICOM 3 CT, MR, PET, or XA data set and
for consolidating multi-stage acquisitions for displaying another data set from one of these modalities
Whole Body MR scanning. into the Integrated Registration protocol.
Registration is performed based on reference
Saving and moving series selection.
You can save registered results in several ways: 2. Review the registration quality with
 As a new reformatted series in the reference or moving visualization tools and validate the result.
exam geometry 3. Optionally, you can define and save the
contours of structures of interest.
4. Save registration results.

Summary
Integrated Registration gives you the capability to
 As Save State after the registration is completed; combine findings from different modality exams
display, segmentations, and measurements are also into a fused model demonstrating relationships
saved between anatomical structures and physiological
 As a DICOM spatial registration object in the same processes. The program makes registration and
exam with the reference series in the AW browser fusion easy and fast with features such as:
 Robust automatic registration that can be run
Operation over a matter of only a few seconds.
Registration is possible in two contexts:  The ability to perform automatic registration
1. Loading a dedicated registration protocol. upon loading the exam from the patient list or
2. Loading multiple volumes into a generic Volume from Dynamic Load, eliminating the need for you
Viewer protocol, after which registration can be to manually launch the registration.
performed on demand using the registration tool.  Automatic registration propagation to all series
acquired in the same exam (i.e. same frame of
reference), speeding the registration process
(specifically helpful for MR exams where multiple
series are acquired).
 Ability to load additional series into an active
session. Registration applied to already loaded
series of the same exam (i.e. same frame of
reference) automatically propagates to the
additional series.
 Interactive manual registration provides flexible
registration optimization based on real time
visual feedback.

Integrated Registration -3
© 2013 General Electric Company.
All rights reserved. Data subject to change.