for Universal Viewer
Multi-Modality Image Management.
Visit us:
www.gehealthcare.com/aw/
applications/integrated-registration/
Features treatment efficacy. Intended Use
• Combines images from different • Define volume of interest in one Integrated Registration provides easy
modalities for enhanced volume model for automatic report to comparison of three-dimensional (3D)
definition. another model for subsequent use images from Computed Tomography
• Fuses functional and anatomical in Radiation Therapy (RT) planning.4 (CT), Magnetic Resonance Imaging
images. • Provide referring physicians with (MRI), Emission Tomography (PET or
• Provides access to Volume Viewer2 clearer, more detailed reports. SPECT5) and X-Ray Angiography
functions, including Multiplanar images (XA). To help physicians in
Reformat, slab and oblique Image Requirements diagnostic radiology or therapy
reformations, triple oblique easy Acquisition position and plane, slices planning, Integrated Registration
definition, volume rendering, 3D resolution, number, thickness, and allows 3D registration between
display, distance and Region of spacing may be different in the volumetric acquisitions that may
Interest (ROI) measurements,3 acquisition of the two exams to be come from the same acquisition
layout management, registered. modality or from different acquisition
segmentations, film, and save. modalities.
• Ability to save registered data as Each image set should meet basic
new DICOM series or as a requirements, however: Regulatory Compliance
Registration DICOM object • Field of view, matrix size, and This product complies with the
• Loads exams and series from CT, display center should be the same European Council Directive
MR, PET, or XA together for for all images inside one series 93/42/EEC Medical Device Directive
registration in the same session. • Orientation should be the same for as amended by European Council
• Offers a choice of four registration all images in the series Directive 2007/47/EC.
methods. • Series should include more than
• Draw and save contours as RTSS one image
1For XA modality series, Integrated
Registration
With Integrated Registration, you can employ four
rigid registration methods:
1. Automatic registration based on “mutual
information” and “matching boundaries” for CT,
MR, PET, or XA.
2. Automatic regional registration, which can be Quality Control
run by defining an ROI upon which the Two methods are made available to you with which
registration methods (listed in #1 above) are to validate the accuracy of the registration:
applied only within the designated boundaries. 1. Qualitatively by visually inspecting registration
3. Interactive manual registration, which, in real results using all available display modes (see
time, conveys translation and rotation made to Visualization below).
the alignment of one data set to the second 2. Quantitatively by defining pairs of common
data set. This method can be used with all landmarks on the two exams. This includes
modality pair combinations. calculation of the Maximal Error on a pair and
4. Landmark registration, which is based on the Root Mean Square (RMS) error on all pairs.
manual definition of common points between
the two data sets. This method can be used Visualization
with all modality pair combinations. Optimized screen layouts are provided which you
You can combine these four methods to achieve can customize to suit your needs.
optimal results. The methods allow registration of The common cursor, active by default, provides you
volumes with linear FOV rescaling and 6 degrees of with a triangulated display in which the cursor is
freedom (translation and rotation). positioned at the same geometrical coordinates in
Non-rigid automatic registration can be employed all views.
for CT to CT data sets only. The non-rigid You can apply dedicated display modes to fused
registration performed on CT series can then be views during your review:
propagated to any other MR, PET, or XA series. • Windows – An adjustable viewing window of the
Global registrations are possible for both rigid and
Integrated Registration -1
registered exam that can be moved anywhere
over the reference exam and shows the
corresponding part of the moving exam.
Contours
With Integrated Registration, you can define one or
multiple contours around relevant anatomical
• Fused – The moving exam is overlaid on the
structures on the exam.
reference exam with an adjustable fusion
percentage.
Integrated Registration -2
DICOM RT Structure Set format for export to DICOM RT-
compatible planning systems.
Integrated Registration protocols also allow you to
define, save, and load RTSS objects.
Autobind MR Series
Integrated Registration gives you the capability to bind
several MR axial series acquired at sequential axial
locations into a single series. This series may then be Initiating a registration protocol is easy:
displayed as coronal or sagittal reformats. This is useful 1. Load a DICOM 3 CT, MR, PET, or XA data set and
for consolidating multi-stage acquisitions for displaying another data set from one of these modalities
Whole Body MR scanning. into the Integrated Registration protocol.
Registration is performed based on reference
Saving and moving series selection.
You can save registered results in several ways: 2. Review the registration quality with
As a new reformatted series in the reference or moving visualization tools and validate the result.
exam geometry 3. Optionally, you can define and save the
contours of structures of interest.
4. Save registration results.
Summary
Integrated Registration gives you the capability to
As Save State after the registration is completed; combine findings from different modality exams
display, segmentations, and measurements are also into a fused model demonstrating relationships
saved between anatomical structures and physiological
As a DICOM spatial registration object in the same processes. The program makes registration and
exam with the reference series in the AW browser fusion easy and fast with features such as:
Robust automatic registration that can be run
Operation over a matter of only a few seconds.
Registration is possible in two contexts: The ability to perform automatic registration
1. Loading a dedicated registration protocol. upon loading the exam from the patient list or
2. Loading multiple volumes into a generic Volume from Dynamic Load, eliminating the need for you
Viewer protocol, after which registration can be to manually launch the registration.
performed on demand using the registration tool. Automatic registration propagation to all series
acquired in the same exam (i.e. same frame of
reference), speeding the registration process
(specifically helpful for MR exams where multiple
series are acquired).
Ability to load additional series into an active
session. Registration applied to already loaded
series of the same exam (i.e. same frame of
reference) automatically propagates to the
additional series.
Interactive manual registration provides flexible
registration optimization based on real time
visual feedback.
Integrated Registration -3