Automatoc Transmision Winter Sonata

You might also like

You are on page 1of 42

NF – SONATA

AUTOMATIC TRANSAXLE
HIVEC (F4A42-2, F4A51, A5HF1)

September, ’04
Chonan Technical Service Training Center
NF – A/T 2

Technical Highlights

♡ Line up

♡ Variable Line Pressure Control

♡ VFS Valve

♡ Reducing Pressure

♡ Comparison

♡ Others

♡ A5HF1

♡ SAT
Line up 3

Variation

Increased torque capacity -


☞ F5A51: 31.5kgf.m, A5HF1: 35kgf.m
A5HF1 : CM D-2.2L, TG λ-3.8L [A5HF1-2]
A5GF1 : NF2.4L [Aug.’05], TG δ-II 2.7L [Delphi PCM]
Variable Line Pressure Control 4

Concept
Comparison Purpose
Controlled
Line
pressure Line
pressure Solenoid valve
pressure
Regulator valve Optimum line
Regulator valve pressure
Pump
Pump

Line pressure (bar) Line pressure (bar) Improved


efficiency
10.5 10.5
8.5

3.2

1 2 3 4 5 Lower fuel
TPS consumption
Gear

Unnecessary high pressure Optimum pressure


Variable Line Pressure Control 5

VFS (Variable Force Solenoid) valve

Being applied on the other maker’s vehicle. (Toyota, Nissan, Ford)

Improved power transmission efficiency and fuel consumption. (1.8%)

Applied on NF, CM, TG [From 2006  FO, GK, JM]

VFS

4-speed 5-speed
Variable Line Pressure Control 6

Line pressure control


Variable Line Pressure Control 7

Line pressure control


UD pressure

A B C
D-1st
N
Variable Line Pressure Control 8

Line pressure control


UD pressure

S-1st D-2nd
D-1st S-2nd
N
Variable Line Pressure Control 9

Line pressure control


UD pressure

D-1st S-1st
N
Variable Line Pressure Control 10

Line pressure control


UD pressure
Variable Line Pressure Control 11

Line pressure control


UD pressure
Variable Line Pressure Control 12

Line pressure control


2nd pressure

D-2nd D-4th
D-1st D-3rd
Variable Line Pressure Control 13

Line pressure control


2nd pressure
Variable Line Pressure Control 14

Line pressure control


Variable Line Pressure Control 15

Line pressure control


LR pressure (D range 1st gear)

VSS=0
Variable Line Pressure Control 16

Line pressure control


LR pressure (Sports mode 1st gear)
Variable Line Pressure Control 17

Line pressure control


LR pressure (Reverse gear)
Variable Line Pressure Control 18

Variable line pressure is prohibited under the following conditions.

- ATF sensor failed or

- PG-A failed or

- PG-B failed or

- A solenoid valve failed (UD,OD,2nd,LR,RED,DCC,VFS) or

- Incorrect gear ratio detected or

- CAN communication failed or

- A/T relay failed or

- Inhibitor switch failed


VFS valve 19

Specification
- Resistance : 4.35Ω±0.35 (RT)
- Current vs. Controlled pressure
1,100㎃ ~ 100㎃ 3.2 ~ 10.5Bar(D-Range)
4.9 ~ 15.5Bar(R – Range)
- Frequency : 600Hz
VFS valve 20

VFS output - N
VFS valve 21

VFS output – D 1st gear


VFS valve 22

VFS output – S 1st gear


VFS valve 23

VFS output – R gear


VFS valve 24

Failsafe
VFS - Short to B+
VFS valve 25

Failsafe
VFS - Short to Ground
VFS valve 26

Failsafe
VFS - DTC
Reducing pressure 27
Reducing pressure 28

Without reducing pressure Reducing valve adjusting


screw

Current valve body VFS valve body


Reducing pressure 29

Reducing valve

Current valve body VFS valve body


Comparison 30

Current valve body VFS valve body


Comparison 31

Current valve body VFS valve body

Line pressure adjusting screw


Comparison 32

Oil passage and the


accumulators on the A/T case
were not changed.
(F4A42 only)

F4A42

A5HF1
Others 33

Step gate type shift lever, A/T relay location

ATM
RLY
Others 34

TCM location

Theta, Lambda

NF D-2.0L : Separated type


(MELCO TCM)
A5HF1 35

SSP (Single Sided Plate)


Items U/D O/D Rev Dir Items L/R 2ND RED

BWA D-0880 BWA BWA BWA BWA SD-


Material Material
-5610 -88 -4301 -4300 -4301 -6100 177-B

DSP 1 DSP 1
Usage 4 2 3 Usage 6 WRAP
SSP 6 SSP 6

Disc inner Disc inner Drum


Φ123 Φ123 Φ152 Φ87 Φ161 Φ152.8
diameter diameter Φ134

Disc outer Disc outer


Φ148 Φ148 Φ166 Φ122 Φ178.5 Φ178.5 -
diameter diameter

Double side Single side


DSP 6EA Waves 10EA - -
Waves 10EA 11EA -
SSP -

Endplay Endplay 1.65 1.09


1.7±0.1 1.1±0.1 1.6±0.1 0.7±0.1 -
(mm) (mm) ~2.11 ~1.55
A5HF1 36

2nd brake
O/D Clutch

Reaction plate

DSP
Reaction plate

DSP

SSP (outer – 3 pairs) SSP


(outer – 3 pairs)
SSP (inner – 3 pairs)
SSP (inner – 3 pairs)

Pressure plate
A5HF1 37

O/D, DIR planetary gear

F5A51 (Three pinions) F5A51 (Four pinions)

For Lower noise and durability

Output gear Differential gear Oil reservoir


(Increased width by 2mm) (Increased width by 2mm) (A5HF1 only)
A5HF1 38

Flat Torque converter

Current New
Diameter Φ260 Φ260
Width (mm) 96.6 93.8
Max. torque (kgfm) 25 35
SAT (Siemens Adaptive Transaxle) 39

Lock-up
2-1 3-2 4-3
1-2 2-3 3-4

2nd lkp 3th lkp 4th lkp


SAT (Siemens Adaptive Transaxle) 40

• Power On Up Shift Learning

Zone Procedure

TPS 25%, 1st  4th gear upshift


3 zone
(Repeat 2~3times)

TPS 15%, 1st  4th gear upshift


2 zone
(Repeat 2~3times)

TPS 7~8%, 1st  4th gear upshift


1 zone
(Repeat 2~3times)

4 zone TPS 40%, 1st  4th gear upshift


(40% ~ WOT) (Repeat 2~3times)
SAT (Siemens Adaptive Transaxle) 41

• N→D, N→R Learning


(1) The learning zone for ‘Static Shift’ is decided depending on the ATF temperature
(-5~120 ) and engine speed.
(2) After N->R shift, select N range for 4sec or more and then shift N->R (Repeat
several times)
(3) After N->D shift, select N range for 4sec or more and then shift N->D (Repeat
several times)

• Power On Down Shift Learning


(1) The learning zone is decided depending on the ATF temperature(50~120 ) and
turbine speed.
(2) Especially it will be mainly affected from the engine condition(load and torque).
(3) There are many conditions to be satisfied, however it is important that the TPS
ratio must be higher than 30% (1.9V).
SAT (Siemens Adaptive Transaxle) 42

Diagnosis

You might also like