You are on page 1of 51

AccuMark™ Professional Edition

Software Release Notice


8.4.0

Release Contents.......................................................................................................................................... 2
Introduction ................................................................................................................................................... 3
System Requirements ................................................................................................................................... 3
Using SQL 2005/2008 Express or SQL 2005/2008 Server for AccuMark storage areas............................. 6
Software Installation Instructions .................................................................................................................. 9
Using Standard AccuMark PE Test Data for System ................................................................................. 13
Coordination of AccuMark Hardware and Software ................................................................................... 15
NESTERserver™ Update for AccuMark V8.4 ............................................................................................ 16
Software Status Update .............................................................................................................................. 17
Known Limitations ....................................................................................................................................... 17
AccuMark 8.4.0 ........................................................................................................................................... 18
Pattern Design Software 8.4.0 .................................................................................................................... 41

Page 1 of 51
AccuMark™ Professional Edition
Software Release Notice
8.4.0

Release Contents
This release contains

• One AccuMark DVD

• One paper document identified as:

Installation document for the AccuMark Professional Edition Release 8.4.0

• Electronic documents: AccuMark PE Software Release Notice for 8.4.0, AccuMark PE Configuration
Notes and AccuMark PE What’s New

• For New Installations and possibly for Upgrades (depending on the version)
• One software security license file
• One hardware security dongle

The DVD contains the full set of executable files and the installation program for the AccuMark
Professional Edition System and is marked as:

AccuMark Family
V 8.4.0
December 2009

Page 2 of 51
Introduction
Welcome to the AccuMark Family software. AccuMark software is the standard for pattern design,
grading and marker making/nesting in the apparel, transportation interiors, furniture and industrial fabrics
industries. It is used by thousands of companies worldwide in more than 24 languages.

We offer two versions of AccuMark - Advanced Edition, to satisfy the needs of first-time automation users
and Professional Edition, for the seasoned CAD user. For more information, please visit
www.gerbertechnology.com

System Requirements
• Adjust the power switch on the back of the computer in accordance to the local power settings (either
115 VAC or 220 VAC).
• All systems require a mouse or compatible pointing device and a standard keyboard.
• A DVD drive is needed for installing software unless you have downloaded the installation from the
GT software download website.
• System settings for Colors must be set higher than 256 Colors.
• Parallel or USB port for workstation security for the security dongle (key). Network connection for
Concurrent or Networked security.

Note: USB to parallel port devices do not generally work with parallel security dongles. It is
recommended to request a Gerber USB security dongle replacement or to use a PCMCIA card.

• You must be logged on as an administrator to properly install the software. You may not be
fully able to uninstall an application under Windows if you are not logged on with the same privileges
that you had when you installed the application. For further details please refer to the Configuration
Notes for Windows.

• Latest Service Packs: AccuMark version 8.0.5 and later installations require that you have the latest
windows service packs installed before proceeding with the installation of AccuMark software.

• Windows Professional Updates: It is highly recommended to keep your systems up to date with the
latest Microsoft Windows critical updates. Windows Updates can be downloaded from Microsoft’s
website. From the Start Menu, select All Programs followed by Windows Update. Note this requires
an Internet connection.

• Microsoft .NET Framework 3.5 or higher must be installed. Microsoft .NET Framework V3.5 SP1
is installed automatically beginning with AccuMark Family 8.4.0 installation. Windows XP SP2 users
may need to install “Windows Installer” prior to AccuMark software installation if the Microsoft .NET
Framework V3.5 SP1 fails to install properly, displaying an error message. Windows installer is
available from the Microsoft downloads website.

• Internet Explorer 7.0 or Internet Explorer 8.0 and curent service packs.

• Install Adobe Acrobat Reader to view the documentation. Additional training materials may require
Microsoft Office Word or Power Point applications or viewers.

Note: With the introduction of AccuMark 8.4.0, the software now supports 64-Bit operating systems. For
individual product restrictions/known limitations, please refer to the specific product’s Release Notes, for
example, the AccuNest or AccuScan Release Notes.

Page 3 of 51
• Refer to the appropriate Release Notes for compatible optional equipment (plotters, digitizers,
networks, etc.).
• The use of disk compression utilities is not recommended.

1.1. Auto-Uninstall of Previous AccuMark software


If you run the installation of AccuMark version 8.0.5 or later and have a previous version of AccuMark V8
software, the installation will first remove the previous version. If your system does not meet the minimum
operating system requirements, you will not be able to proceed with the installation. You may return to a
previous version by re-installing that software.

1.2. Required User Permissions


There are many permutations and combinations of user permissions that an administrator can implement.
The AccuMark installation does not override security permissions (does not take ownership). Since an
administrator can create registry keys at most levels, it is required that a user with administrator privileges
perform all setups. You may want to check the permissions of AccuMark Family data and application
areas if users are having problems with data or programs.

Installation on AccuMark Professional or Advanced edition runs a security permission program at the end
of the install that sets administrator privileges for the Users group to AccuMark data (storage areas), its
program directories and registry entries. Setting Permissions provides the ability for non-administrator
users to access Gerber data and applications. For complete details, see Setting Permissions.

To see a list of folders and registry values that are created by the AccuMark installation and require the
appropriate security settings to run the applications, please follow the System Requirements link from the
main installation html page for Setting Manual Permissions.

1.3. Windows XP Professional Requirements

Hardware Recommended
Processor Type Pentium IV
Processor Speed 2.0+ GHz or higher
Video Adapter / Ultra VGA 1280 X 1024
Monitor
Hard Disk Capacity 20+ GB
Memory 2 GB
Service Packs SP3 or higher

Additional Requirements
• Microsoft Critical Updates which can be found by clicking the Start, All Programs, Windows Update
on your XP or Vista System. Note that this requires an Internet connection.
• In XP, turn off Fast User Switching when creating new users. If this is turned on, it will result in
configuration errors. Fast User Switching is not supported in Vista. Do not use Switch User with
Windows 7 operating systems.
• In XP, turn off Simple File Sharing through the Tools, Folder Options in Windows Explorer or Control
Panel.

Page 4 of 51
1.3.1.Windows Firewall with Windows XP SP3

Note beginning with XP SP2 and higher that a newer, more capable Windows Firewall is installed and
many services and capabilities are automatically turned off or disabled for security reasons. If you are
having any problems running AccuMark Family software, please contact your Gerber customer support
representative or use the Gerber Firewall Assistant which is available from the GERBERnet software
download website.

1.4. Windows Vista Business, Enterprise or Ultimate Requirements


Windows 7 Ultimate or Professional Requirements

Hardware Recommended
Processor Speed 3 GHz 32-bit (x86) or
1.7 GHz dual core
Hard Disk Capacity 20+ GB
Memory 2+ GB
Service Packs SP1 or higher

Additional Requirements
• Microsoft Critical Updates which can be found by clicking the Tools, Windows Update from the
Internet Explorer. Note that this requires an Internet connection.

Windows Vista/Windows 7 Folder Virtualization

With Windows Vista Microsoft has changed where user account profile and program data gets stored.
Instead of storing all profile data under c:\Documents and Settings\ as they did with Windows XP, things
are now split between c:\Users\ and c:\ProgramData\ (on a standard installation).

Under User Account Control, Windows Vista and Windows 7 restrict portions of the Windows file system
and registry. UAC also restricts write operations during normal operation (i.e., standard user mode). For
example, applications no longer have unlimited access to C:\Program Files and C:\Windows. The system-
wide file system and Registry writes are automatically and silently redirected to per-user locations that
won't harm the wider system.

To accommodate existing software for Windows that writes to protected file directories, Microsoft
provides a backward compatibility technology known as Virtualization. Virtualization is often referred to as
data redirection because it functions by funneling attempted access to protected locations to new
locations stored under user profiles. For example, if a legacy application attempts to write to the Program
Files directory, UAC silently redirects that operation to an unprotected user-specific folder.

Page 5 of 51
Unsupported Operating Systems
The following operating systems are not supported for AccuMark Family software. While you may be able
to install this software, it is possible you will experience technical problems.
ƒ Windows ME
ƒ Windows XP Home, Media Center, TabletPC Editions
ƒ Windows 95 and Windows 98
ƒ Windows NT
ƒ Windows 2000
ƒ Windows Vista Home Premium or Home Basic
ƒ Windows 7 Home Edition
Note: AccuMark V8.2.2 and earlier releases are not compatible with Windows Vista. AccuMark V8.3 and
higher are provided for use on Windows Vista Business, Enterprise or Ultimate editions providing the
system meets the minimum requirements for Vista as listed above. AccuMark V8.4 and higher are
provided for use on Windows 7 Ultimate and Professional providing the system meets the minimum
requirements for Windows 7 listed above.

Using SQL 2005/2008 Express or SQL 2005/2008 Server for


AccuMark storage areas
AccuMark data can be optionally stored in SQL databases instead of or in addition to the userroot-type
storage areas. These SQL databases are equipped to look and feel the same as userroot storage with
several advantages:
o Eliminates the potential for file-locking problems that can occur across networks as with userroot-type
storage areas
o Increased limit for data, now up to 100,000 data items per data type
o Allows the ability to create sub-storage areas or sub-folders
o Allows the ability to set allow or deny permissions to individual storage areas
o Allows the ability to set read or write permissions to individual data types

AccuMark Supported SQL Versions


o AccuMark Version 8.1 supports SQL Server 2000 or MSDE 2000
o AccuMark Version 8.2 supports SQL 2005 or SQL 2005 Express in addition to SQL Server 2000 and
MSDE 2000
o AccuMark Version 8.3 supports SQL 2005 or SQL 2005 Express and SQL Server 2000
o Starting with AccuMark Version 8.3.1 also supports SQL 2008 Express or SQL 2008
o AccuMark Version 8.4 supports SQL 2005, SQL 2005 Express, SQL 2008, and SQL 2008 Express

NOTE: MSDE is not supported in Windows operating systems newer than Windows XP.

It is highly recommended to use the same version of SQL for all systems that will be accessing the same
storage areas for compatibility purposes.

NOTE: Subfolders for SQL storage areas were implemented in AccuMark V8.2 and WebPDM 5.1
release. Please see the What’s New document for detailed information on AccuMark subfolders for SQL
storage areas.

It is highly recommended to install the latest service packs and updates for SQL SQL 2005 Server
and SQL 2005 Express requires SP2

Refer to the Training Docs Manuals documents for setup and additional detailed information for the
various SQL versions that are support by the AccuMark Family of products.

Page 6 of 51
1.5. SQL 2005 Express
SQL 2005 Express may be installed from the Supplemental Components V2 CD March 2007. Microsoft®
SQL Server 2005 Express is Microsoft's imbedded database engine. It is a free and easy-to-use version
of SQL Server 2005 that replaces the Microsoft SQL Server 2000 Desktop Engine (MSDE). SQL Server
2005 Express makes it easy to deploy powerful, secure, data-driven applications. SQL Server Express
can function as an embedded client database as well as a basic database server.

For complete details for installing or upgrading to SQL 2005 Express, please see the document Installing
SQL 2005 Express.pdf available in the Training Docs Manuals folder on the AccuMark DVD.

1.5.1.Additional Requirements for SQL 2005 Express


In addition to the requirements listed above per operating system, SQL 2005 Express also requires:
o Microsoft .NET Framework
o Microsoft Internet Explorer 6.0 SP1 or later (prerequisite for .NET Framework)
o 192 MB RAM minimum
o 600 MB free hard disk space
o Pentium III Compatible or higher processor (500 MHz minimum, recommended 1GHZ or higher)
o Windows XP Professional SP2, Windows Vista (other operating systems are supported, see
complete list in the Installation Requirements).
o On networked XP Professional systems, the user logins must have a password
associated with the user names. This applies for PC to PC network or accessing SQL
2005 Express. The standard behavior for XP requires a password

1.5.2.sa password (System Administrator)


It is highly recommended to enter a sa password when prompted during the install (do not leave the SQL
2005 Express instance with a blank password). Entering an sa password will help prevent disastrous
worms from trying to log into the default instance of a SQL/SQL 2005/SQL 2008 Express server with a
blank (null) sa password, thus helping to prevent it from infecting your server. Refer to Microsoft
Knowledge Base Article 313418 for details.

1.5.3. Microsoft SQL Server Management Studio Express (SSMSE)


Microsoft SQL Server Management Studio Express (SSMSE) provides a graphical management tool for
SQL Server 2005 Express Edition. For more details refer to the Microsoft SQL Server Management
Studio Express link on the Supplemental Components V2 CD.

It is recommended to use the Backup and Restore utility in SSMSE for backing up and restoring
AccuMark storage areas with SQL 2005 Express. See the Backup and Restore for SQL 2005
Express.doc in the AccuMark Manuals folder.

1.5.4. Upgrading MSDE to SQL Server Express


If you currently have MSDE installed, it is recommended to install SQL 2005 Express as a separate
instance and then copy existing MSDE storage areas into new SQL 2005 Express storage areas. See
Installing SQL 2005 Express.pdf for detailed information (available in the AccuMark Manuals folder).

SQL 2005 Express may be installed from the Supplemental Components V2 CD March 2007. SQL 2005
Express is a reliable storage engine and query processor that runs on most operating systems and is
redistributed royalty free. It is a low cost option for a database server.

SQL 2005 Express Notes:


• Language dependant
• SQL 2005 Express by default uses Windows Authentication
• SQL Server may also be used to access AccuMark SQL storage areas and is recommended

Page 7 of 51
for use with large AccuMark systems. Refer to the section, Supported SQL Server
Configurations for details. Additional setup information can be found in the document,
Management of AccuMark Data storage using MS-SQL-2000 Server.
• Database size is limited to 2GB
• Runs best with 5 or fewer concurrent users when using database transactions (read, write,
moving of data, order process or similar operations). You can have more than 5 concurrent
users manipulating data. However, when the SQL 2005 Express reading and writing
transactions are run simultaneously, limitations are invoked.

1.6. Supported SQL Server Configurations


Shown below is GT’s recommendation for a SQL Server configuration for use with large AccuMark
systems. This configuration may be used as a guide in preparing similar configurations using locally
available PC servers.

1.6.1.Database Server Hardware General Requirements


Dell PowerEdge 2600 Pentium Xeon 2.4GHz
• Pentium Xeon 2.4 GHz 512KB Level 2 cache
(Single processor installed, dual processor capable)
• 533MHz front side bus
• 1GB high-performance Registered PC2100 DDR SDRAM memory
(6GB maximum capacity)
• 10/100/1000 TX LAN adapter with 25-foot CAT5 Patch Cable
• PERC4/Di RAID controller (128MB cache)
• Three 36GB Ultra 320 SCSI , low profile, 10K rpm, hot swap disk drives
(RAID-5 capacity 72GB)
• Internal DDS-4 20/40GB tape backup with 5 tapes
• 24x IDE CD-ROM Drive and 1.44MB Floppy
• 730W hot-plug power supply
• Five hot-plug/redundant fans
• Keyboard and Mouse
• 15-inch Color Monitor
• 56K Internal modem
• 700va UPS
• Three years Dell Hardware Support Services,
Next Business Day Parts and Labor On-Site Response

1.6.2.Software

Notes:
AccuMark’s use of SQL Server is not a traditional database application. The AccuMark’s use of SQL
Server involves two database tables, one of which contains approximately a dozen type records. There
are no complex queries to be processed involving difficult joins or views. Indeed, there are only a handful
of simple queries that are used throughout the entire operation of AccuMark.

AccuMark’s use of SQL Server is limited to saving and retrieving BLOBS using simple queries. As a
result, the database server’s throughput will be limited only by disk performance and network limitations.
The database server’s CPU will not be consumed by traditional database operations, like optimizing
queries, handling indexed-based operations, etc. Our recommended hardware and software are based
on the preceding observations.

Disk Storage: Hardware RAID 5 should be specified for performance and reliability. 10,000 RPM SCSI
drives will provide the best performance. (UDMA 7,200 RPM drives, each with 8MB of cache would be

Page 8 of 51
adequate.) To estimate the amount of disk storage space recommended, total the amount of disk storage
space used for data storage within the present AccuMark storage areas. Multiply this by two (for
database and RAID 5 overhead) and then multiply it by two again for future growth. For example, if the
customer currently has 15 GB of data, a total of 60 GB of storage should be ordered and configured using
RAID 5.

Network Interface: A NIC designed for server application including an on-board processor, should be
specified. 100 MBPS is a must. Most new servers now come with integrated 1000/100/10 Mbps Ethernet.

Memory: Memory is relatively inexpensive. Since only very simple database operations that are
performed by AccuMark, no great demand for memory is placed upon the system. 512 MB of RAM is
adequate. Yet memory is the cheapest technology and has the greatest performance benefit in a
server/database system. Since the cost difference between 512MB and 1GB or 2 GB is very small, 2GB
is recommended.

Software: SQL Server 2005/2008 Standard Edition, processor license version. Windows Server 2008
may also be used if the customer is comfortable with this latest OS from Microsoft.

Processor: Because of the light-weight queries, even a single processor will be adequate. Throughput will
not be limited by CPU speed. A single 2.0 GHz - 2.4 GHz processor may be used. The availability of a
dual processor upgrade option provides for future growth.

Power Backup: An APC 700va SmartUPS.


Data Backup: A DAT DDS4 20/40GB
Maintenance: A 56K modem and Diskeeper disk defragmentation software.

Software Installation Instructions


The Installation procedure for Release 8.4 will automatically install the following software on the
AccuMark system:
• Pattern Design
• ASTM Pattern Conversion Wizard
• AccuMark Batch Processing
• CSV Tools
• DXF Converter (DXF Import)
• Lconvert (Lectra to AccuMark)

Additional applications such as Winplot are included with the professional software license but
must be installed separately.

IMPORTANT!
Clock Date and Time
It is extremely important to check the date and time BEFORE proceeding with the installation of
the software. Turning back the clock once the software has been installed and running is strongly
discouraged!

Installing the AccuMark Professional Edition Release 8.4.0

IMPORTANT: Close any open programs before installing the software.

No Previous Version of AccuMark installed


Simply follow the Steps to Install below.

Page 9 of 51
Previous Version of AccuMark 8.x installed
If a previous version of AccuMark 8.x is installed, it will automatically be uninstalled prior to
installing this software. A dialog box is displayed informing the user when the installation is
started.

Previous Version of AccuMark 7.6.x installed


If you have AccuMark version 7 software on your system, you must uninstall it first. Use the
Add/Remove Programs in the Control Panel to remove this software.

Important! If you uninstall AccuMark V7 with previous V8 already installed:


When AccuMark V7 and V8 are installed on the same PC, AccuMark V8 must be reinstalled if
AccuMark V7 is uninstalled. Reinstalling V8 will restore the software environment so that V8 will
continue to run properly.

Steps to Install

1. Insert the DVD of AccuMark Professional release into the DVD drive, or locate the Setup
folder if the software was downloaded and saved to disk.
2. On most Windows systems setup will automatically start the installation when the DVD is
loaded. If AutoPlay is not enabled on your system,
a) From the Start menu, select Run…
b) Type e:\setup (where e: is the letter of your DVD drive)
c) Select OK

3. Install Acrobat Reader and view the documentation.


4. Click Install AccuMark.
5. You may be prompted by a Software Security Prerequisite. If you are installing the AccuMark
software for the first time, or if you are upgrading from a previous version you will be
prompted to update the software security drivers. Select OK to continue with the security
prerequisite.
6. You may select an alternate destination directory when prompted, or simply accept the
default folder.
7. For a standard installation select Typical. Selecting the Typical Setup type will assure all
required applications and files are installed.
8. You may be prompted to choose to overwrite only the Sample storage areas that are
installed with PE installations. Selecting Yes will remove any existing data in those storage
areas only, and re-copy the sample data. Selecting No will leave the current data intact. The
sample storage areas are GTBASICS, DATA70 and SIL2000. Overwriting these storage
areas will not affect any other user created storage areas.

Page 10 of 51
9. If you desire to use the Send To option (to email data) available in the AccuMark Explorer,
you must select one of the Email Options when prompted. This option will work with the
Email system that is installed on your PC. For instance, if you are using Microsoft Outlook,
select Microsoft Mail/Lotus cc:Mail option.
10. The installation will also launch a subsequent install for the Problem Report Utility for new
installations or if updates have been made to these applications. The Problem Report Utility
provides the ability to send electronic reports to GT.
11. The installation will also launch a subsequent install for the new GTLM Security for new
installations or if updates have been made to these applications. GTLM installs Sentinel
drivers and services that will be used for the V8 keys and license files.
12. On new installations a license agreement is displayed. Read and accept the terms of the
agreement.
13. An informational dialog box will display instructing the user how to install your license file.
This is only needed for new installations or purchased Upgrades (for example, 8.3 to 8.4).
V8.4.0 requires a new license file. Maintenance updates do not require re-installing your
license file (for example, 8.3.0 to 8.3.1). Refer to section 5 Software Security for details.
14. The security permission program is started at the end of the install to set administrator
privileges for the Users group to AccuMark data (storage areas) and program directories.
Setting Permissions provides the ability for non-administrator users to access Gerber data
and applications.
15. You can optionally view the Release Notes and What’s New documents at the end of the
installation, which will open the Release Notes using Adobe Acrobat Reader.
16. When the installation has completed, select Yes to restart your computer, if prompted.

License Agreement
When you run the AccuMark system for the first time after installing the software an approval of
the licensing agreement is necessary. Once the affirmative response has been entered, the
licensing agreement will not display again

Directory Structure
The installation creates the C:\USERROOT directory structure, which contains the data, required
by the system. The default program files are located in the subdirectories under c:\program
files\Gerber Technology, unless a different destination is chosen during the installation.

1.1. Hardware and Security


AccuMark Products use a combination of software based security technology and a hardware
security key (dongle) to license and protect the software. Version 8 software will not run on a
system that does not have access to a security key and license file.

1.1.1.Workstation Security
If you are using a workstation system with its own local security key and license file, attach the
security key (dongle) to the parallel or USB port of the PC or workstation. A Security License File
is unique to each security key (dongle). The combination of key and license file will allow
activation of the AccuMark Family software as stated in the software subscription contract.

Page 11 of 51
If you are using a workstation or a server that will be using concurrent licensing, please see the
document Concurrent Licensing that is in the AccuMark Manuals folder on the AccuMark DVD for
information.

1.1.2.Retrieving your License File


The security license file name is a combination of the product and key number with the file
extension of .lic, for example accumark123.lic. Copy the appropriate license file onto the system
with the matching key number.

If the license file was received through Email, save the attached file to a location on your hard
drive or on the desktop (for example, c:\program files\common files\gerber technology\gt license
manager). If the license file was received on a floppy, it may be installed directly from the floppy
and/or copied to your hard drive.

Important! Version 8.4.0 or higher will require a license upgrade from previous 8.3, 8.2, 8.1 or
8.0 software. If an 8.0.x, 8.1.x, 8.2.x or 8.3.x version of software is currently in use and will be
upgraded to 8.4.x, the license file must also be upgraded. Please contact your customer service
representative for assistance.

1.1.3.Software Security License – Install License program


The AccuMark Family Product DVD installs an Install License program that easily copies your
license file into the proper destination for use by AccuMark applications. Use the Install License
icon on the Desktop, or from the LaunchPad on the AccuMark Explorer/Utilities page, or use the
AccuMark V8 folder, select AccuMark Explorer/Utilities and then Install License.

A dialog box displays allowing you to choose the Product and source location for the license file
(use the ellipses (…) button to locate your license file). Note the key number in the dialog box
and match to the right license file. Run the program once for each Product. The program, by
default, looks for files of type .lic. It will prompt you to overwrite the existing license file if one
already exists.

The Install License application will automatically verify if your key and license file match, and then
display the license components allowing you to easily see the applications as specified by your
license entitlement.

1.2. Starting AccuMark Professional Edition Components


Start the AccuMark applications from the following locations:

1. From the Start menu select the Gerber LaunchPad G icon or, from the Desktop, double
click on the G icon if LaunchPad is not displayed. The AccuMark LaunchPad menu contains
the selections for Pattern Processing, Digitizing and Pattern Design, Marker Creation,
Editors, Plotting, Cutting, AccuMark Explorer and Utilities and documentation.

2. In addition, from the Start menu, applications can be accessed from the associated program
folders in AccuMark V8. Shortcuts to the desktop can also be created from this location.

Page 12 of 51
1.3. Support/Problem Reporting Procedure
Customer Service support hours are from 8am until 7pm Eastern Standard Time. If you have a
question or encounter a problem, please contact GT’s Customer Service Department. Our toll
free number 1-800-321-2448 can be called during support hours from anywhere in North
America. International customers please contact your local Gerber Office or Agent and Distributor
for assistance.

Using Standard AccuMark PE Test Data for System


This section describes the procedures for checking the AccuMark Professional Edition system by
using the standard version 7 test data, which is installed, in the DATA70 storage area. The
DATA70 storage area will automatically be installed during a typical installation if no other
storage area by that name exists, and may be optionally overwritten if the storage area already
exists.

It is recommended for users to create their own storage areas to contain their data (do not use
storage area names DATA70, GTBASICS, or SIL2000). These areas should only be used for
training or testing purposes.

DISPLAY A PIECE
From the LaunchPad menu select AccuMark Explorer

1. Select LADIES-BLOUSE-BK and open it in Pattern Design.


2. Bring piece into the work area and select View/Grades sizes.
3. Press right mouse button or cancel functions.
4. Exit Pattern Design.

ORDER A MARKER
From the LaunchPad menu select the Marker Creation, Editors page and
click on the Order Icon or, open AccuMark Explorer.

1. From the Order form select File Open and select TESTMARKER.
2. Press the green arrow key or select File - PROCESS.
3. The message Processing order: TESTMARKER should now display on the screen. When
the order has finished processing, the message Processed Successfully should display.

RETRIEVING A MARKER
From the LaunchPad menu select the Marker Creation, Editors page and
click on the Marker Making Icon or, open AccuMark Explorer.

1. From the File Menu select Open.


2. Two marker names will be displayed:
TESTMARKER an unmade marker (created by ORDER A MARKER above)
LADIES-BLOUSE a made marker
3. To select a marker from the list, highlight the marker name using the mouse, and select
Open.

Page 13 of 51
SELECTING AND SLIDING PIECES IN MARKER MAKING
Move the mouse cursor over the numbers below the pieces in the icon menu. The piece count
will highlight and the associated piece name and size will display in the status bar.
1. Select using the left mouse button.
2. When a piece is selected, the perimeter will become dotted and the piece will attach to the
mouse cursor.
3. To slide the piece into the marker, press and hold the left mouse button and draw a vector in
the direction desired. Release the mouse button.
4. The piece will move in the direction of the slide vector. If the piece fits into the area where it
was slid, it will place.

PLOTTING A MARKER
Use the Hardware Configuration icon to configure a plotter. Then from the LaunchPad menu
select the Plotting and Cutting page or, open AccuMark Explorer.

1. From the LaunchPad options select the MARKER PLOT icon.


2. Select the location as Data70. In the marker name field select LADIES-BLOUSE.
3. From AccuMark Explorer, right-click on the marker LADIES-BLOUSE and select Send To
Plotter.
4. Press the green arrow or select PROCESS ALL from the File drop down menu.
Note: Auto Process is turned off by default enabling the plot form to display. If the plot form
does not appear, check the Plot Options.
5. If the plotter is online and properly configured it will begin plotting.

Page 14 of 51
Coordination of AccuMark Hardware and Software
Supported Software
The following table shows version compatibility between releases of AccuMark and other related
software. Software versions listed are the earliest releases that are known to work with specific AccuMark
versions. A more recent version may exist.

AccuMark Release 7.6 8.0 8.1 8.2 8.3 8.4


Foreign Language ---
National Language Support 1.2.4
CSV Tools for Windows 7.6.5 8.0 8.1 8.2
AccuMark Database 7.6.5 8.0 8.1 8.2 8.3 8.4
Programming Software Toolkit
AAMACVT for Windows 4.3.4 ---- ---- ----
Pattern Conversion Wizard - --- 8.0* 8.1* 8.2* 8.3* 8.4*
ASTM
MCONVERT for Windows 4.1.1
AccuMark Batch Processing 7.7.0 8.0* 8.1* 8.2* 8.3* 8.4*
AutoMark --- 8.0* 8.1* 8.2* 8.3* 8.4*
Booster Pak 7.3.1
MTM 3.0.1 8.0 8.1 8.0 8.3 8.4
Pattern Design 2000 2.0.3 8.0** 8.1** 8.2* 8.3* 8.4*
DXF to AccuMark Piece 1.0.1 8.0* 8.1* 8.2* 8.3* 8.4*
Converter
Ultra Queue 1.3
WinPlot 3.0.1 8.0** 8.1** 8.2** 8.3 8.4
Infinity User Interface 1.3.2 1.4.3
Lconvert for Windows * 8.0.2 8.1* 8.2*
*
AccuMark™V-Stitcher ™ by 8.0.7 8.1 8.2 8.3 8.4
Browzwear
AccuNest PE 8.1 8.2 8.3 8.4
AccuNest EE 8.2 8.3 8.4
NESTERserver 4.0 5.1 6.0 6.1 6.1 6.1
Cutworks
WebPDM 5.0 5.0 5.1,5.2 5.2 & 5.3&
& 5.3 5.3 6.0/6.1

* 8.x Releases that are part of the AccuMark Professional software.


** 8.x Releases that are also available as stand-alone.

Lconvert component – A2L


Lconvert for Windows is included in the 8.03 release or later. The AccuMark to Lectra software
component of Lconvert 8.0 is included on the DVD but available for an additional charge to new
users. It also requires an additional software license code.

Page 15 of 51
NESTERserver™ Update for AccuMark V8.4
NESTERserver will need to be updated in order to operate it in the AccuMark V8.4environment.

The NESTER Update for AccuMark 8.4 must be installed on all systems that will submit to the AccuMark
V8.4 Nester queue. Nester Update for a Nesting Server is not supported on 64Bit operating systems.

• Job Submission will allow AccuMark workstations to submit jobs through UltraQueue for nesting.
• The full installation will install NESERserver and UltraQueue updates for the nesting server.

Supported Plotters
The following plotters are supported on the AccuMark system:

AccuJet 510/520 Lectra FlyPen(Lectra)


Accuplot 100 MicroJet 20/30
Accuplot 300/310/320 MicroJet 30W
Accuplot 350 MicroJet 60/85
Accuplot 700 MicroJet 60W/85W
Accuplot 700-CXS Misomex
Accuplot 700-VPS Mutoh AC-1650 (mutoh-ac)
APC-L800 (Zund-L800) SM-1000-1.5 (sample15)
APC-XL800 (Zund-XL800) SM-1000-2.0 (sample20)
APC-L1200 (Zund-L1200) SM-1000-2.5(sample25)
Gerber Infinity (Infinity) SM-1000-3.0x2 (samp30x2)
Gerber Infinity II (inf-II) SP-100
HP DesignJet 600 SP-120
HP DesignJet 700 SP-150
HP Windows device driver SP-200
(hpwdev) WildTA10
HP7440 WildTA10b
HP7475A WildTA10BL
HP7595 (generic) WildTA40
HP7595 (hp7595) WildTA400
Investronica P2000(inv_p2000) WildTA500
Investronica Partner (INV_PART) Windows device driver(windev)
XLP Series Plotters

Page 16 of 51
Software Status Update
Refer to the Configuration Notes and What’s New with AccuMark in the AccuMark documentation folder
of the Launchpad for further up-to-date information relating to your software and installation.

Known Limitations
Online Help
Due to a limitation in Internet Explorer versions 6, 7 and 8, double-clicking a link to a popup window in the
Online Help files included with this software may present an error message. Closing the error message
and single clicking on the link will open the appropriate popup window.

Page 17 of 51
AccuMark 8.4.0
Software Changes and Enhancements
Enhancement changes are documented in the What’s New document in the AccuMark LaunchPad and
the program folder.

AccuMark 8.4.0
Changes since 8.3.1

AccuNest

11790 AccunNest will stop working when job from batch with ALL ENGS in previous
version. Now it has been fixed.
9721 Attached marker can't be nested by Eng1 in previouse version. Now it is fixed, this
marker can be nested by Eng1.
11142 Block Fuses are now maintained in nested markers. Use the option "Unplace All
Pieces" when Restarting a marker to maintain them.
11288 Corrected a problem for foldable pieces on tubular fabric. In prior releases, folded
pieces werre sometimes left out of tubular marker. This issue has been fixed, and all
pieces are placed correctly.

11377 Corrected an issue of crashing with tubular and bookfold makers, using Restart.
10009 Corrected an issue present in previous versions when data issues were present.
The user will now be alerted if a marker contains select intersecting line segments
by an error message in the log file. Previously, the marker failed but no indication of
this failure was reported.
11624 Corrected the Accunest engine problem when set too large tilt amount(90 degree) in
laylimit.Previously,nest failed with Bad Nest File error.Now,the too large tilts will be
restricted to 45 degree to nest marker successfully.

10595 Corrected the image problem when AccuNest save and push to RDBMS.Previously,
the image was not generated.Now,it is fixed.
10873 Corrected the overlap checking problem for the marker which contains rotated
folded pieces.Previously,it reported successful even when the pieces reached
outside marker.Now, it is fixed.

9778 Corrected the overlap problem with laylimit Bookfold and flipped pieces when use
AccuNest.Now, pieces are correctly placed.
11064 Corrected the overlap with Engine 3 pack. Previously, pieces overlap in the specific
marker after packed with Engine 3. Now the overlap will not occur.
11849 Corrected the problem for AccuNest read Laylimt CW/CCW restriction. Previously,
AccuNest was not according to Laylimit CW/CCW to rotate piece to get better
utilization. Now, it has been fixed. Engine 1 ignores assymetric tilt limits - it takes the
minimum of CW and CCW as its tilt limit value and uses it for both CW and CCW.
Engine 2 limits tilt internally to 22 degrees.
11503 Corrected the problem for AccuNest. Previously, marker can't be nested when size
quantity is defined 0 in the first model. Now it has been fixed, marker can be nested
correctly.

Page 18 of 51
8672 Corrected the problem for marker with constructs through AccuNest.Previously,
pieces were placed on the first 9 constructs. Now, it has been fixed.
9845 Improved the efficiency of Engine 1. The new engine requires an update to the
nesting key. Refer to the AccuNest What's New for the procedure to request this key
update.
11373 Improvements have been made for markers with folded pieces. If Finish is selected
with a marker containing folded pieces, an error message will be displayed. Restart
will nest the marker correctly.

11513 New engine1 nests marker and gets better efficiency.


8878 Pieces are overlap in marker in previous version. Now it is fixed.
12306 Previously, nest marker contains piece in foldable category being not foldable, or
having fold line with invalid orientation would fail process or pieces overlap. Now, it
has been fixed. Marker is nested with warning message "Laylimits have been
restricted due to some peices in foldable category being not foldable, or having
invalid fold line orientation", these kind of pieces are not folded.

11795 Previously,HASP driver for Engines 2 and 3 were not automatically installed. Now, it
has been fixed.
AccuScan

10682 Corrected the problem for create internal line. Previously, some internals are show
in scan preview but nothing was created at all. Now, internal line created is
improved, most lines can be created.

10693 Drill mark is not graded with the option Grade Drill Holes in previous version. Now, it
is fixed.
9256 In previous versions narrow cutouts used to be converted into slit lines Now upon
proper selection of Line Thinness and Thin Line Compensation settings narrow
cutouts are converted correctly. Recommended settings:
Line Thinness=Middle
Thin Line Compensation=None

10406 In previous versions there was an issue when a minimized AccuScan window was
closed by selecting Closed from the Right Mouse Button Menu. The next time
AccuScan was invoked, it would run in minimized mode. This issue has been
corrected.

9507 In previous versions, the creation of internal lines and cut outs was usually
misunderstood by AccuScan. Closed cut outs and/or internal lines crossing each
other were converted into wrong shapes. These issues have been corrected. Now
the creation of internal objects is properly handled.

11586 Set Up under the Actions Menu is now gray out to prevent making changes in a
non-existing scanner, if there is an invalid scanner driver, or if there is no scanner
driver available in the system,

11887 There was a conflict with the communication between Graphtec Scanner IS210-
11eN and AccuScan; this problem has been resolved.

Page 19 of 51
Activity Log

9461 Previously, print or print view Activity Log and Version Information will crash. Now, it
is fixed. print view or print Activity Log and Version Information correctly.
Alteration

9763 Corrected the case that alteration on some paste piece was wrong in marker.

11653 Previously, altered piece with wrong seam in MED. Now, regenerate the marker,
altered pieces are correct in MED.
7896 Corrected an issue with annotation being incorrectly oriented on flipped pieces.

Annotation

11278 Corrected an issue with the Annotation Editor being corrupted after performing a
marker plot. The editor may now be saved and/or deleted without issue.
11131 Corrected the annotation problem in marker plot.Previously,the Default annotation
also worked for internal line and drill holes.Now, it is fixed to only work for piece.
11049 Corrected the issue that RMB Cut & Copy/Paste were not working in 8.3.0.

3142 Corrected the problem for delete the fist row in Annotation Editor. Previously, delete
the fist row would make the annotation mistake. Now, "Insert Row" and "Delete
Row" are grayed in context menu on the first row of Annotation Editor.

9560 Corrected the problem for insert row before the fist row in Annotation Editor.
Previously, insert row before the fist row would make the annotation mistake. Now,
"Insert Row" and "Delete Row" are grayed in context menu on the first row of
Annotation Editor.
12153 Previously, "Delete Row" and "Clear Contents" work incorrectly in Annotation Editor.
Now it is fixed.
9962 The Annotation table has been updated so that double clicking on left selections will
automatically copy the contents to the right column.
Assyst
10931 Assyst Design files of version 27 can be supported now.
7723 Corrected the problem when importing Assyst marker data.Previously,even if the
marker name is less then 20 characters, would get error message. Now the marker
can be imported with correct name.

9697 Previously,notches at internal lines would be lost when importing assyst file. Now, it
has been fixed.

Page 20 of 51
ASTM/AAMA

12114 Corrected an issue that ASTM and AAMA file exported from same model in Assyst
would get different result when import to AccuMark, some notches would be
imported lost or with wrong angles. Now it has been fixed.

11595 Corrected the case that function DCU and PDS\File Open was not converting rule
table & assigning PDS correctly for the specific file 'LT-SPEED-JKT-Scale10-
RUL.dxf' and 'LIGHT SPEED JKT 08-2.rul'.

9651 Corrected the problem for importing the dxf files with both graded nest and
external rule file as well.Previously,it could not be correctly converted.Now,can
choose import option "One Piece Per Size" to convert all graded piece to a single
piece
11660 Updated the rule table lookup conditions in DCU import option.Now,"NORULE"
has been removed from Rule Table field and once import dxf file without rule table
name,it will look for alternate rule table in DCU Import Option or PDS Preference
before assigning the dummy rule table name.

AutoMark

9687 Automark has been updated.

11424 Corrected the issue where 'Fabric Yield' displayed wrong since the this entry has
been removed from the AutoMark Report.
11350 When sending multi-markers from Explorer to AutoMark, processing job list hung.
This issue has been corrected.
Backup

11042 Corrected the backup issue when used Backup in the lower right of the MSDE
Manager backup window.Previously,it didn't run a backup.And now,it works.
10701 Corrected the case where the function BackUp couldn't backup or restore Nework
drives .
11043 Corrected the option issue when schedule backup job.Previously,the Daily,Weekly
and Monthly options were always active.Now,they are gray out when not checked.
11024 Correctted the probelm when created the MSDE backup job with duplicate
name.Prior to this,invalid job was created and no further jobs could be created.
Now,the duplicate job will not be created.

Batch

7504 Corrected the batch cut processing problem for a completed batch
job.Previously,the cut file would be given a second extension. Now,the export cut
file will be overwritten when autoprocess is on.

10499 Corrected the plot error problem when send marker with 20 characters length
name to batch plot.Now the plot file can be successfully created.
7785 Corrected the problem for cut file name created by batch
processing.Previously,option "Append Count to Filename" didn't work. Now,it is
fixed.

Page 21 of 51
8995 Corrected the problem for local plot job name, which is created from batch
processing. Previously,the job batch sent to local plotter had the DOS file naming
in plot queue. Now, it is fixed.

10136 Corrected the problem for some specified orders processed via Batch and
AcuNest.Prior to this, some jobs were with Marker Pending status.Now,they can be
succesfully completed.
12533 Corrected the problem that MmAmBatch Order files not saving in correct SA
w/default. Now, it has been fixed.
11396 Corrected the problem to order process in Batch.Previously,orderload failed for
MED, Auto and Lay method.Now, it is fixed.
2946 Fixed the overwrite peompt issue in Batch.Prior to this, option "Yes To All" didn't
work for all markers in the list.Now,overwrite can be done for all items once select
that option.
9954 In previous version, when sent job from batch to AccuNest, in QueueSubmit,
"Save Best Nest" line is always display firstly. Now,the the display is correctly.
11207 Corrected the problem for confirm replace message in Batch.Previously, once
performed Yes To All or No To All, would not get confirm replace message. Now, it
is fixed.

Block Buffer

9585 Corrected the hang problem when highlight column to copy and paste in block
buffer.
11450 Corrected the problem when copy/paste and cut/paste in block buffer.Previously,
the pasted value can't be saved.
8928 Rule number "999" can't be saved in previous version. Now it has been fixed.

CSV Tools

2043 Corrected the problem in CSV tool when file name contains blank. Previously,
CSV cannot access file in the directory which name contains a blank character.
Now, it has been fixed.

Cut Generation
9720 Corrected the problem for ASTM cut files.Previously,that format can't be
recognized in AccuMark,now it is fixed.

11304 Corrected the problem for copy/paste row in Cut Generation. Previousely,
copy/paste row worked wrong. Now it has been fixed.

10207 Corrected the problem for cut generation.Previously,folded mirrored pieces and
cut option "Bi-L/R Mirror" lead to crash.Now, it is fixed.

10813 Corrected the problem for CutGen in Vista system. Now,it will create the
destination directory if it doesn;t exist.The default destination on a clean installation
is changed to C:\Cut.

Page 22 of 51
11078 Corrected the problem for the marker with construct when cut using ASTM
format.Prior to this, crash happened.Now,cut file is correctly generated.

8201 Corrected the problem fot auto process cut generation and save to current storage
area. Previously,error message appeared when there was existing data.Now, it is
fixed.

9895 Corrected the problem of overlap exsits in cut file in previous version. Now, this is
fixed.
10233 Corrected the problem of piece has unclosed perimeter in cut file after delete
static block in MED. Now the piece has closed perimeter in cut file .

10664 Cut data now reports the correct format for marker length.

9017 Some pieces are distorted in Cut data in previous verion. Now it is fixed, all piece
in cut are correct.

Cut Param Tbl

11050 Corrected a issue that the Label 1 and 2 couldn't be selected in CutGen
Parameter.
8398 Corrected the perimeter line was not completely cut with option Bi L/R mirror set in
Cut Parameter Table.
11074 Corrected the problem for the categories in P-Cutter.Previously,multiple
categories couldn't be saved. Now, it is fixed.

11122 Default Bite Length in CutGenPt is changed from 0.00 to 1.00In(2.54cm). The
previous 0.00 can't be saved.

10982 Edge Tolerance not converted between Metric/Imperial in previous version. Now it
converts correctly.

10815 Using "Save As" to create a new Cut Generation Parameter Table no longer
crashes.
Cut Plot

8816 Correct the problem for copy/paste row in CutPlot. Previously, pasted row always
get invalid strings. Now it has been fixed.
11540 Correscted the issue of Open function in Cut Plot. Previously, Open in RMB in cut
plot form can't open cutview window. Now it has been fixed.
DCU

11423 Collected an issue that some specific standard dxf data would be failure to convert
by DCU. Now it has been fixed.
11400 Corrected a specific case where the DCU Export Report Results Log displayed
the wrong total piece and model warnings when piece names in the model didn't
exist in the storage area.

Page 23 of 51
10884 Corrected a specific case where the function Data Conversion Utility was unable
to import Assyst Marker.

10784 Corrected an issue that DCU could only export ASTM/AAMA file with Metric unit.
Now it has been fixed, proper unit Metric or English can be writed into exported
ASTM/AAMA dxf file according its export unit Metric or Imperial.

10590 Corrected an issue that importing special Assyst AAMA data would cause DCU
stop responding.

11411 Corrected an issue that some special standard dxf files were imported with wrong
piece shape, now this problem has been fixed.

12003 Corrected an issue that some versions of Assyst design formats such as V27,V28
couldn't be supported in AccuMark. Now,these design files can be imported and
grading can be assigned to pieces if the data have folders like design/styles and
graderules both.
12679 Corrected an issue when importing certain pieces in a model were getting the
following warning message “different vertex count for different sizes, Unable to
create internal rule table. Sample Size imported only.” The nest for such pieces
was not created, causing the piece to be duplicated multiple times as if it was one
per size. This issue has been corrected.

10485 Corrected the count problem in DCU when import rule table.Previously,Converted
count and Total Count were zero.Now, they are correctly displayed.

10874 Corrected the DCU conversion error for standard dxf.Previously,it failed because
of incorrect tolerance setting.Now,it can be correctly converted.

10752 Corrected the error message when run DCU without printer installed.Now DCU
can be correctly run.

10851 Corrected the issue for rule table importing in DCU/PDS. Prior to this,rule table
was not imported and saved.Now,it is imported and dxf data is graded.

10435 Corrected the issue that none was checked for Export AAMA/ASTM option after a
clear installation.

10307 Corrected the issue that the ASTM/AAMA rule file was imported with zero values
for pieces by Data Conversion Wizard.

10300 Corrected the issue that the grading was lost for the error "different vertex count
for different sizes" when import DXF file.

12592 Corrected the issue that the radius (curved intersection) of the DXF file was
incorrectly importing in DCU.

Page 24 of 51
11198 Corrected the issue when selecting storage area the SQL Disk of LookUp field
couldn't be kept.

10639 Corrected the issue where the Status column of Data Conversion Utility didn't
clear all icons when processing same files twice.

11161 Corrected the message when rule table is not found duing dxf file importing. Now
if the associated rule table doesn't exist,the warning message is changed to "Rule
Table *** doesn't exist.The system is assigning rule table name 'Import' with one
single size 'X'".
10289 Corrected the pop-up error that when run Data Conversion Utility as a limited user
and select Report Results. Now the Report Result path is changed to :
'C:\Documents and Settings\current_user\Application Data\Gerber
Technology\Silhouette 2000\Conversion\'

11194 Corrected the problem for DCU and PDS options on a clean system.Previously,
the options would not run.Now,they work well.

10616 Corrected the problem for importing ASTM file by DCU/PDS


Open.Previously,error message "Piece perimeter is not closed" appearred for
some files.Now,import conversion is successful.

8656 Corrected the problem for importing AutoCad piece. Previously, all points in the
piece had N attribute. Now each point of LINE and POLYLINE segment is imported
as N point, intermediate points between particular segments is imported as N
point. All other segment types are imported with smooth points. Smooth points are
not stored in standard dxf file directly, they are generated by approximation
algorithm and they depend on the import option “Curve Approximation Tolerace”.
So in order to get pretty smooth line like in AutoCad, have to change the default
value, make it smaller.

11275 Corrected the problem for importing models and markers to SQL database and
subfolder by DCU.Prior to this,the entry couldn't be saved in RDBMS, now the
model and marker information will be pushed to RDBMS.

11593 Corrected the problem for importing some StyleCad AAMA files.Previously,could
not correctly import those files that have no rule table name defined in dxf file and
grading was not correct due to G1 line issues. Now all those issues are fixed.

10415 Corrected the problem that Export Standard DXF file always took inch as unit
whatever you select Imperial or metric as export unit. Now Export Standard DXF
file with metric as unit, select Centimeter as import unit to match;Export Standard
DXF file with imperial as unit, select Inch as import unit to match.

10624 Corrected the problems to make overwrite Rule Table valid and Tolerance field
editable.

10930 Corrected the specific case that the IGES file couldn't be imported to the Subfolder
whose path >17 characters.

Page 25 of 51
10319 Corrected the unit conversion problem in DCU import.Previously, could not get
proper size for other CAD system text such as "CM".

10498 DCU will crash when import the MDL file in previous version. Now it is fixed, DCU
can import this MDL.

10357 DCU will crash when import this MDL in previous version. Now it is fixed, dcu can
import this MDL. PDS also can import this MDL.

11916 Import the attached mdl, DCU will crash in previous version. Now it has been
fixed, DCU import the MDL correctly.

11661 Now DCU Import Options-rule table look up is enable for ASTM/AAMA and TIIP
Tab . Previously it was greyed out.

9718 Now Print Preview can give multi pages if there are many contents in Data
Conversion Wizard.
11312 Periviously, if there are more then 100 pieces in the dxf file, DCU convert the dxf
only get 100 pieces. Now, thie problem is fixed, DCU convert the dxf can get all
pieces more then 100.

11261 Previously, DCU import AAMA/ASTM dxf or TIIP dxf, if the category is blan in the
dxf, after imported, piece categary same as piece name which is changed with the
option "Piece Name Only", "Precede Piece Name with Style Name" or "Append
Style Name to Piece Name". Now, after imported, piece categary will always same
as original piece name and don't change with that three options setting.

11746 Previously, pieces in standard dxf file could not be converted wholly by DCU and
PDS, now, it has been fixed.

11881 Previously,AAMA.dxf file generated by 3D flattening tool could be imported with


notches lost. now,it has been fiexed, all notches can be imported well.

11693 Previously,the grading of drill holes were missing after converted by DCU/PDS.
Now,it has been fixed.

9532 Problem for displaying Japanese piece name in DCU Import Results has been
corrected.Prior to this,invalid characters were displayed.Now,the "dashes" will
replace all invalid characters.

11166 The ASTM/AAMA Import has been updated so that if there is a grade rule table
name in the dxf file but the default rul file is not in the same location as the DXF
file, the system is auto assigning rule table name "IMPORT" with only base size.

10712 The rules of a-11775 for import of incorrect graded nest were implemented after
the task a-10712 and overwrote the rules from a-10712. So please refer to the
What's New note in #11775.

11647 When exporting DXF with modified grading rules in DCU, the warning messages
in Export Result Log didn't display right. This issue has been corrected.

Page 26 of 51
11291 When exporting Marker/Piece to Standard DXF with Space in annotation or Plot
Parameter table name in Export Options, it failed and got an error. This issue has
been corrected.

9195 When importing the AAMA/ASTM file and if some pieces have different vertex
count for different sizes, the grading is wrong after importing by DCU/PDS. This
issue has been corrected, each size is imported as a single piece now.

Data Entry
Forms
11308 Corrected the problem that there were duplicate files in File Recent List for Marker
Plot Parameter and Layrule Search windows.

11346 Previously, copy item from Excel to Marker Plot ,Cut Plot and CutGen were get
wrong pasted value. Now it has been fixed.

10495 Recent file list is now available in previous broken forms.

Database
Engine
8959 AccuNest does not create mrkr entry in RDBMS when saving in previous
version.Now it is fixed, marker info will be updated after AccuNest save the best
marker.
8960 AccuNest is not updating Last Mod date in RDBMS when saving in previous
version.

Now it is fixed, all date&time be updated correctly after AccuNest saved the best
marker.
11961 Corrected display error when set user permissions. Previously, change marker rw
permission, model rw also display changed. Now it has been fixed.
11620 Corrected problem when add/modify MSDE login user on XPSP3 and Vista
system.Previously,MMC error happened.Now, it is fixed.
10563 Corrected the crash problem when copy data to the storage area, which has the
same name of Relational Database. Now, data can be successfully copied.
10938 Corrected the issue when imported Assyst/Investronic Marker to a subfolder more
than 6 levels the DCU crashed.
9456 Corrected the problem for field update in Cad_Marker_Details and Cad_MK_Sizes
tables after adding bundles/pieces. Previously, the Size and Quantity fields
displayed the value set in order. Now, it shows the actual size quantity in marker.

8801 Corrected the problem for Model_Material in Cad_MK_Model.Previously, attached


marker without fabric code will leave that field blank.Now, N/A will be replaced.
9432 Corrected the problem for Size field update in Cad_Marker_Details after adding
bundles/pieces. Previously, the Size field displayed the size quantity set in order.
Now, it shows the actual size quantity in marker.

10491 Corrected the problem for Size field update in Cad_Marker_Details table after
adding pieces/bundles.Previously, had to place some pieces to make that field
update. Now,it can be correctly stored into RDBMS without placing piece.

Page 27 of 51
11525 Corrected the problem that when save an unmade marker to relational database,
the Length field in Cad_Marker_Details was not updated. Now that field will
become 0 when all pieces in marker are returned to menu.

10814 Corrected the problem to generate image when push Accumark data to
WebPDM.Previously,there were no image displayed in WebPDM when
automatically pull models. Now, the piece images can be correctly created.

8530 Corrected the problem when importing zip file to SQL database.Previously, the
data weren't shown in Relational database.Now,all data are correctly shown.
11621 Corrected the write permission problem for plot data.Previously,plot file could still
be sent to DOS without permission.Now, it is fixed.
8779 Original Marker is not updated in RDBMS which is deleted when attach marker in
previous version. Now it is fixed, the deleted original marker will be updated in
Cad_Marker_Details, IsActive=0.

12559 Previously marker and piece images were not generated when Chinese Character
in data name in webPDM. Now, add new registry value "FixImageFileName" of
type REG_BINARY and set it to 1 in
"HKEY_CURRENT_USER\Software\Gerber\SQLSupport\RDBMS", marker and
piece images are display correctly in WebPDM.
10937 The DCU used the P-USER-ENVIRONMENT "overwrite" checking so that the
existing markers in subfolder couldn't be overwritten when imported Lectra/Inves
Markers. This issue has been corrected.

Edit Digitize

11594 Corrected the issue when verifying Digitized Data in PDS it diplayed unavailable
rules messages.
11986 Corrected the problem for copy/paste function in Edit Digitize. Previously,multiple
rows couldn't be pasted correctly.Now,it works.
10112 Corrected the problem for Save command. Previously, Save command open Save
As window. Now, it has been fixed.
Explorer

8814 Characters display incomplete in Plot Output in previous version. Now, it is fixed,
the interface is ok on SC OS
11497 Correct the option issue in Export Summary.Previously,"Select Model Options"
was always available.Now, only when check "Include Components",that option can
be used.
11255 Corrected the problem for Previous Modified date in AccuMark Explorer.
Previously,after saving marker,its Previous Modified Date was incorrect.Now,it is
fixed.
11265 Corrected the problem for the read only sql storage area. Previously,that kind of
storage area was locked. Now,it can be normally visited.
11764 Corrected the problem that when check the imported storage area in accumark
explorer.Previously,after checking, Created and Last Modified Date were changed
to Current Date and Previous Modified was lost. Now all date can be kept.

Page 28 of 51
11185 Corrected the problem when Delete with Components with Filter option.Prior to
this,only the displayed data were deleted.Now,all components will be deleted.
7286 Corrected the problem when rename sql storage area with duplicate
name.Now,choice of Rename SQL is disable because the physical files don't
change name.
7417 Previously, when export to zip file, the check box "Include Components" and
"Model Options" were not sticky. Now, it has been fixed.
11492 Same warning message pops up twice when save as model with components in
previous version. Now it is fixed, the warning message only given one time.
4556 The new option "Yes To All" has been added to the function "Export V8 Piece to
V7" so that it is able to replace existing data item from V8 storage area to V7.
Export
1309 "export to zip" will append to a zip file, instead of overwriting it.
6784 Corrected the confusing option in Export dialog.

Now, the checkbox "Select Model Options" has been renamed to "Include Pieces
From Selected Model Options". And the dialog caption of all model options has
been changed to "Export Pieces From Model Options".
Find

11337 Corrected the issue when searching one SQL storage arae in Find window all
SQL Storage areas be showed if they had same front part name.
7655 Previously the Find function was not allowing you to delete data items that were in
subfolders, but it did allow you to delete data items that were in parent sql storage
areas from the Results pane. Now it is fixed, can delete and can rename item in
subfolder from the results pane of Find

7411 Previously, open Find from SQL sunfolder which was using # for separation. Now,
it is changed to "\".
11160 The searching in SQL storage area has been improved.Previously,it took a long
time to search data in a big SQL storage area. Now,it is quick to find the data.
General
9014 It has been updated that not display error and warning message during DCU
processing.
GERBERplanne
r
10953 Corrected the issue when running Read Marker Data function in Garment Editor
and then Received a Run Time Error 453.
5944 Corrected the problem that couldn't save and open planner editors with Chinese
character.
6002 Corrected the problem when delete size in Garment Editor.Previously,run time
error occurred.Now, it is fixed.
10751 Corrected the runtime errors when ran orders through Planner.
10658 Fixed the version problem for GerberPlanner. Now,the version is correctly
displayed.

Page 29 of 51
7913 Gerber Planner has been updated so that it could run in Thailand and Chinese
Language systems.
7897 Gerber PLanner now supports access to SQL Storage Areas.
5945 When clicking or entering value in some fields of Import Cut Orders function in
Planner, "Run-Time error5" showed. This problem has been corrected.
IGES

10759 Corrected a specific case the incorrect message "Internal is not closed” was
displayed when importing IGES.
6166 Corrected the problem for imported IGES file.Previously,imported IGES piece to
AccuMark, exported to IGES format and imported it again, another internal line
was added on G0 line.Now, it is fixed.

Import

12439 Corrected an issue that model notes files couldn't be displayed in the list of Non-
AccuMark files. Now it has been fixed.
12416 Previously,unsupported characters in piece name would be imported different
when open in PDS/DCU and Marker Making. Now,for all kinds of data,the first
unsupported character in item name will be replaced with 'X' and others replaced
with '-' after imported.
Installation

11045 Downloading files from GERBERnet now have a CRC check added to help
determine if the download was successful.
10714 Service Pack Check has been implemented in each installation, it will ask user to
check SP2 for XP as "Service Pack 2 or greater for Windows XP must be installed
before continuing with the installation. You may obtain this Service Pack from the
MicroSoft Website as http://www.microsoft.com/windows/downloads".

Laylimits

11316 Copy list to laylimit category column will get duplicate name in previous version.
Now it is fixed, all case copy/paste in this form can get correct result.
Lectra

11284 Corrected the problem of Lectra markers and models have different piece names.
Perivously, marker can't be imported. Now it has been fixed, during performing
PLX import we can get same pieces names like are build from MDL file during
MDL to AM import.
11905 DCU will crash when import this MDL in previous version. Now it is fixed, dcu and
PDS can import this MDL well.
10471 DCU will crash when import this MDL in previous version. Now it is fixed, dcu and
PDS can import this MDL.
11602 Previously, Lectra marker had overlaps as the piece was flipped and rotated. Now,
it has been fixed, Lectra marker can keep piece flipped and rotated.

Page 30 of 51
9589 The rotate/ flip piece in Lectra Marker were converted correctly by DCU.

Made to
Measure

11587 Corrected the crash issue when choose the first record to do Prev or select the last
record to do Next. Now, it works correctly.

11915 Corrected the problem for MTM order generating. Previously, if the order with two
garments and used the laylimit with 20 characters name, error occurred when
generated order. Now,the order can be successfully created.

10741 Corrected the problem for negative ShrinkStretch in MTM order.Previously, symbol
"%" was not displayed.Now,it can be correctly shown.
11164 Corrected the problem for unit in MTM and storage area.Now,the data can be
correctly converted for different setting of MTM unit and storage area unit.
11163 Corrected the problem when delete the utlization value in MTM
order.Previously,error "Invalid procedurecall or argument" appeared. Now,it is fixed.
10606 Corrected the xyShrink/Stretch problem in MTM.Previously,1 turns to
100.00%.Now, the values are correct.
10707 In previous versions there was a limitation on the number of alpha sizes allowed to
enter when creating a Base Measurement File due to the name length. This
limitation has been resolved. There is no limit now based on the number of sizes
allowed to be entered at once.
6220 In previous versions, when field selections made in Preferences for MTM were
deleted and wanted to keep fields blank, MTM was unable to save such changes.
This issue has been corrected.

11583 Now the warning message "Batch is no license to run" will instead the previous
runtime error when run View\Batch Status in a standalone MTM computer.
11331 Corrected Display Alterations on a stanalone MTM system, when AccuMark is not
installed. Now, this function will display the alterations correctly.

Marker Plot

10817 Corrected a case where the function Marker Plot program was not responding when
click Process.
11114 Corrected the crash problem for marker plot. Previously, marker plot with different
annotation forms led to crash and error.Now, it is fixed.
11246 Corrected the crash problem for marker plot.Previously, plot marker twice led to
runtime error and crash. Now, it is fixed.
11436 Corrected the problem for bump line annotation plot.Previously,for some old version
data,annotation was probably plotted twice. Now,it can be correctly plotted out.
11274 Corrected the problem for marker plot many times with Annotation.Previously,the
MarkerPlot form hanged.Now,it is fixed.
11035 Corrected the problem for plotting marker to DOS and generating image.
Previously,the plot file was lost when image created. Now, the existing plot files will

Page 31 of 51
not be affected.

10831 Corrected the problem to send unmade marker to AccuNest with Relational
Database configured. Previously,got save failed result. Now, the marker can be
successfully nested with correct image created.

10853 Corrected the problem when process marker image to a non existing directory
C:\Plot. Now, that directory will be automatically created when process.
11313 Corrected the right mouse button copy and paste functions in Marker
Plot.Previously,copy and paste didn't correctly work. Now, it has been fixed.
10820 Errors/Overlaps outputting AccuMark hpgl Plot files as DOS HPGL and DXF in
previous version. Now it is fixed.
11390 new flag in marker plot parameter table

"plot half pieces with dashed lines"


Marking

11040 Corrected a slide problem in marker making that caused some sliding layrule
movements to overlap pieces. This has been resolved.
8920 Corrected issue for marker constructs when resizing marker window.Previously,all
constructs were missing.Now,it is fixed.
6411 Corrected marker length problem in printout.Now, it correctly shows 3m, not
2M100.00C.
11889 Corrected most problems with unplaceable pieces when regenerate marker.
11133 Corrected the case that paste piece in options of model couldn't be processed to
marker.

9956 Corrected the issue if a Piece was Dynamic Split 50% the part of the Piece in the
Marker Plot fliped.
7377 Corrected the marker length problem when perform UNDO.Previously,the marker
length wasn't updated.Now, it is fixed.
11221 Corrected the problem for Back layrule.Previously,it would not return to the original
state after doing Back to the end of layrule.Now, it is fixed.
12224 Corrected the problem for displaying cut sequence line in a marker with unplaced
pieces. Previously, the cut lines were incorrectly displayed.Now,the marker can be
opened with correct cut sequence lines.

10122 Corrected the problem for opening marker.Previously, error message "error in
MMEDINIT icons" occurred because of the unexisting or corrupt file
\USERROOT\SYSTEM\TEXT\icon.dat. Now, it is fixed.

12000 Corrected the problem for Size field update in Cad_Marker_Details after Copy Fuse
in marker, which has added bundles/pieces. Previously, the original added quantities
and its copies in block fuse were missing in Size field. Now, it is correct.

6491 Corrected the problem for the piece with override buffer 0. Now, the piece will have
solid line,not previous dash line.
11059 Corrected the problem for the special mirror piece with v notch on mirror
line.Previously, those pieces could not be folded in Marker Making.Now,they can be

Page 32 of 51
done.

10739 Corrected the problem for the values "YLD/BD" and "YLD/DZ" in Marker
Making.Previously,they turned to invalid if return all pieces to menu.Now,it is fixed.
12536 Corrected the problem when change the buffered piece to blocked piece through
Block/Buffer Override.Now, the blocked piece will have solid line rather than the
dash line.
7114 Corrected the problem when converted PLX file to Accumark Marker
Making.Previously, the CU couldn't be correctly shown before refreshing.Now it has
been fixed.
7323 In previous version, if place all pieces in a marekr and run Cut
Sequencing>Automatic, and then return all pieces and place some in the work area.
And use any of the cut sequence options, it will crash or not response when
selecting the pieces. This problem has been corrected.

11086 Modify sliding layrule will dispaly zig zag graphics in icon menu in previous version.
Now it is fixed, piece icon is correct in the menu.
10962 No piece split tool in the custom toolbar in previous version. Now these split tools
have been added to custom toolbar.
10531 Parallel buffer may lead to piece overlap when sliding piece group.This problem
was corrected and can't reproduce overlap issue again.
10845 PDS annotation were shown incorrectly in MED in previous version. Now it has
been fixed.
11326 Resolved an issue in Markermaking with the version information being listed
incorrectly. The version number shown now is correct.
31 The annotate bump line dialog has been enlarged to show entire 20 characters.
Matching

11239 Corrected a problem with point matching on an altered flipped piece. Previously,
point matching was applied incorrectly on the altered flipped piece. This issue has
been corrected.

10934 Corrected the problem for line matching in Marker Making.Previously, it was not
applied.Now, it is fixed.
MicroMark to
AccuMark
Conv
3181 Corrected the problem for Annotation Convert.Prior to this,conversion tool created
only one line for different annotation lines, which led to annotation open
error.Now,the conversion wroks properly.

10539 The conversion of MicroMark markers with 45 degree rotation restriction on pieces
will now be maintained in the AccuMark marker after the conversion. If 90 rotation is
allowed, that will still be maintained. The control of 45 degree rotation requires the
use of the Environment Variable MM45CONSTRAINT=1

Model
10489 "Add Piece" option has been removed from model print options in AE.
11022 "Dyn Split" option is added in model print options in AE.

Page 33 of 51
11397 Corrected a case where the Model columns displayed incomplete after a clear
installation.
11355 Corrected a data specific crash opening the model form.
10395 Corrected an issue that the first row of pieces would overlap header information
when printing a model.Now piece information and head display well.
11958 Corrected the case that Paste piece's Category and Description couldn't be printed
out in model print.
10379 Corrected the issue for model print.Priviousy,it was not possible to print selected
pages.Now, it can print.
5615 Corrected the model print issue on Simplified Chinese operation
system.Previously,there were some extra characters under X Shrink and Y Shrink
headers.Now, it is fixed.
11263 Corrected the print preview problem for paste piece in model.Previously,paste piece
wihout flips amount couldn't be printed.Now, it is fixed.
10964 Corrected the problem for editing piece name,category and description in model
Rename Mode. Previously,the changes were not saved.Now,it is enabled.
11558 Corrected the problem for model print with option.Previously,duplicate option would
be printed.Now, it has been fixed.
9606 Corrected the problem for model print.Previously,an empty page was got at last.
Now,model pages can be correctly printed.
11030 Corrected the problem for opening modified pieces in earlier version.Previously,the
pieces saved in 8.3.1 couldn't be opened in 8.3.0.Now, it is fixed.
12033 Corrected the problem for the model option print.Previously, only piece name was
printed out for the removed option piece. Now, its image, piece category and
description all all available.

10623 Corrected the problem in Model Editor when right click on column header field to
run Insert.Previously,all column headers were changed. Now,Insert function can be
correctly done and keep column headers right.

11065 Corrected the problem to open model with option in PDS.Previously,there was
problem to retrieve model.Now, it is fixed.
10389 Corrected the problem when reselect piece in model Rename Mode and then close
window. Previously,no save prompt message was provided.Now,it is fixed.
9497 Corrected the shrink stretch problem in model editor.Previously,those values
couldn't be deleted by Delete key or Clear function.Now, it is fixed.
10535 Insert row will remove the X/Y Shrink Stretch value in previous version. Now it is
fixed.
8696 Model option only support one digit for the flips in the previous version. Now it has
been fixed, it can support two digits.
2483 Previously, model option name can accept invalid characters. Now, if enter invalid
character in model option name, it will prompt "Option name contains unsuported
character XXX"
11376 The shrink stretch values in the Model Editor will no longer change from 1 to 2.54.
Notch
11231 Corrected crash problem when copy and paste fields between 2 notch tables.

Page 34 of 51
11341 Corrected the copy and paste problem in notch table. Previously,copy and paste led
to invalid entry error.Now, the correct data can be pasted.
11202 Corrected the problem for check notch on flipped pieces.Previously,the notch could
not flip in marker plot, now it is flipped along with the pieces in all cases.
Open/ Open
With
11292 Use Filename Filter Lookup doesn't display all storage area in previous version.
Now this function is complemented as below:
1. go up one level, the filter string will disappear and the checkbox will become
unchecked
2. switch to C: or another device, the filter string will disappear and the checkbox will
become unchecked.
3. switch to another storage area, the lookup settings will remain.
4. switch to another device, the filter string will disappear and the checkbox will
become unchecked

Order
Processing
11280 (if a marker exists for overwrite, but an error occurs, then the original marker will
remain in the storage area) this is different behaviour from previous releases.

11115 Corrected the issue when running Order Process the Look In field of the poped
window was blank.
10665 Corrected the problem for the message shown in Generate Marker result
window.Previously, it displayed Cancelled although the marker was generated.Now
it is fixed.

11232 Order Process will be frozen when copy/paste Order Name in previous version.
Now it is fixed, copy/past can be used correctly in this form.

11917 Previously, a notch on the merge point disappear after generate marker.Now, the
notch is kept in the marker.

Other

12518 Corrected the wrong seam corner problem in marker making due to the unclipped
lines. Now the specified piece looks good in all applications, including PDS Plot,
Piece Plot, Order Process, Marker Making, Marker Plot and Cut Gen.

12333 The new toolkit for V8.4.0 to handle Importing Accumark userroot data into
webPDM DB (Pulling in Data into the RDBMS) has been verified and works
successfully with webPDM 5.3.2829 and V6.0 client.

Piece Plot

11687 Corrected a specific case where the function Piece Plot crashed if the first line of
alteration rule was blank.
11222 Corrected the crash issue for piece plot in AE.Now,piece plot can be successfully
performed.

Page 35 of 51
11443 Corrected the display problem for Piece Plot windows title.Previously,the title was
changed after run Print Preview and Close to return.
11715 Corrected the problem for create piece image to DOS file. Previously, the image is
not created if the DOS destination path has dot. Now it has been fixed, the image file
can be created correctly.

11575 Corrected the problem in piece plot. Previously, "Yes to All", "No to All" and
"Cancel" on overwrite confirm window are not work. Now it has been fixed.

2938 If a piece plot was saved as a plot file, and all sizes are created as individual files,
individual files were not created for each size. This problem has been resolved.
6299 If the Piece Plot Parameter Table name includes some special characters, it may
lead to crash when plot twice in Piece Plot Form. Now the issue has been corrected.
7576 Plot piece with paste piece in nest, the paste piece in the base size only in
previouse version.Now, it is fixed, paste piece will be plot in nest.
Piece Plot
Param Tbl

6135 Corrected the crash prolem to save P-PIECE-PLOT before closing the
form.Previously, if made edits, saved,then made more edits and then tried to close
the form, crash occurred. Now, it is fixed.

Plot Queue
Management

12571 Corrected the problem that plot job not visible in plot queue. Now, it has been fixed.

12124 Corrected the problem to drag and drop plot files to specified plot
queue.Previously,it failed to do that with error message. Now, all the supported plot
files can be dragged from windows explorer to plot queue.

Print
11335 Corrected the case where the column title of Model Option was printed incorrectly.
3515 Corrected the issue that the title and path of model editor in print preview was not
clear when using some specific printers.
11544 Corrected the problem for model print layout. Previously,the column header was
printed on each row. Now, the header is just for first row.
Problem
Report
12069 Corrected the issue that PRU couldn't send problem if select Active Messaging as
Email Configuration. Now it has been fixed.

12591 Now new PERU in Version 8.3.14 has been used in AccuMark, AccuScan,
AccuNest etc.

Page 36 of 51
Reports

11241 Corrected the crash problem in explorer when do marker report because of the
string overflow.Now, those markers can run report without problem.
11728 Corrected the problem for piece area in piece report. Previously, some pieces have
closed H internal line which Area were in negative value in piece report. Now it has
been fixed, piece area is shown correct value.

10577 Corrected the problem for the extension of CSV file.Previously,the extension name
was incorrect when save report to CSV.
10698 Corrected the problem in Marker Header Report.Previously,Length field is
incorrectly displayed for different options.Now, it is fixed.
6988 For Marker Report,display units of some fields are incorrect when use Feet as the
unit.Now it has been fixed.
8575 In previous version select User ID, date and time fields in cut report, model all
piece report, marker piece report and piece all piece report will crash. Now crash will
not occur.
10915 In previous version, add piece/bundle or add new size in marker, the Size in Marker
Header Report was not updated. Now, it has been fixed.
10846 Marker Head Report has been updated so that the Yield/Bundel and Yield/Dozen
fields display the correct values as them in BD and DZ fields even split piece in
marker.
10545 The problem for length displayed in report has been fixed.Previously, changed the
view options could not correctly display the length. Now, it is fixed.
Rule Table

12047 Corrected a problem in rename break size in AlphaNumeric rule table. Previously,
rename break size would change grade value. Now, it has been fixed.
9571 Corrected a problem in rename size bresk. Proviously, rename all size breaks,
irregular grade value would change to regular. Now it has been fixed.
11567 Corrected the problem when changed grade method.Previously,Grade values are
updated wrong after change grade method. Now it has been fixed.
11639 When saving rule table in "Base Up-Down Cumulative" Grade Method the values of
the grade rules were auto changed. This issue has been corrected.
Security

11796 AccuMark Family applications have been updated to run with the new V8.4 security
license files
11422 Corrected the license expire message in Information dialog.Previously,some words
were cut off. Now, it can be completely shown.
Size Code

9478 Corrected the Cut option in Size Code right button menu.Previously,it didn't work.
Now, cut function has been fixed.

Page 37 of 51
11104 Corrected the problem for the actual size name, which exceeds 6
characters.Previously,invalid character was shown in name.Now,the warning
message will be provided to let you rename.
7564 Corrected the problem to enter size name and alteration rule name in
sizeCode.Now,the size name is limited 6 characters and alteration rule name is
limited 10 characters.
11578 It was unable to print negative values with the desimal sysmbol "comma" from Size
Code. This issue has been corrected.
System

9027 Corrected an issue with European regional settings for SP plotter settings related to
Cut and Tab Length. The values entered using a comma for decimal will now be
read correctly.
11597 Corrected the case that Copy & Paste could not be done between AM editor forms
and Microsoft Excel.
Translation

10308 Corrected some translation problem in AccuNest.

9987 Corrected the dialog layout problem on Japanese operation system.Now, the
SaveAs dialog can be completely displayed.
8050 Corrected the file name fonts of File Dialog Box in PDS and Marker were displayed
very small in Hebrew OS.
10619 Corrected the issue that the characters “Labels” was un-translated in Piece Plot file
even after installing Chinese Translation packs.
10370 Corrected the problem of invalid Japanese characters. Now, all Japanese
characters are showing correct.
12035 Corrected the problem on Japanese system with language installed. Previously,
some buttons in Delete Confirm dialog were hidden. Now, it is fixed.
11025 Corrected the traditional characters problem in TC system.Previously, some
applications could not correctly run with the data using those characters.now, it is
fixed.
12222 Previously, "Marker Plot Paramater" was not shown in Permissions edit dialog after
installed language pack. Now, it is fixed.
11193 Previously, file contents window was in English. Now, it is translated.

11319 Previously, HPGL files couldn't be plot by winplot as the string "MK" translated.
Now, string "MK" is back to english, regenerated HPGL files are plot correctly.
11874 Previously, Japanese can't be shown completely in order selection fields. Now, we
can menually change “MS Shell Dlg” in
\HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows
NT\CurrentVersion\FontSubstitutes to “Microsoft Sans Serif”, Jpanese would be
show completey in Order Editor.
11646 Previously, some error massages were not shown in DCU import or export after
installed language. Now, it has been fixed.

Page 38 of 51
12580 Previously,in SC/HK/TC AccuMark Explorer,if run Model-All Piece Report and
Piece-All Piece Report,Area and Total Area fields in report always got same values
without SQ units although different units in View>Options were checked. Now it has
been fixed. Value and unit of Area and Total Area can switched well according the
selected units.
10793 Resource strings have been updated to use positional arguments making it better
for the string substitution parameters to work with translated text.
10361 Some characters in Accumark and PDS with JP language show invalid.This issue
has been corrected.
12475 Sytle Convertion Options dialogs have been updated to properly display translated
text
11005 The marker name was displayed wrong when retrieving marker in Greek OS with
Greek translation bundels installed. This issue has been corrected.
10659 Titles for Import Settings & Export Settings are now translatable: "Restore MED
Settings" and "Save MED Settings

6437 Updates have been made to allow for the translation of marker report strings
including header columns.
UltraQueue
11362 New fields "Yield/Dozen","Yield/Bundle","Fabric Cost" and "Cost/Bundle" now can
be exported to csv files.
Utilities

3095 Fixed the problem of Lock Storage Area in AccuMark Utilities, now the selected
Storage Area can be locked, and it will show as locked status in AM-Explorer after
refresh the list in AM-Explorer.

7421 Functions "Lock All Storage Areas" and "Unlock All Storage Areas" has been
updated so that all storage areas of one device can be locked or unlocked at a time .
8538 Previously, it always shown first SA on C in Set New Defaults. Now, the problem
has been fixed. The selected SA is kept in Set New Defaults. On new install system
or after Reset System Defaults, the Device and Storage Area fields are blank in Set
New Defaults.

View/Quick
View
11090 Corrected the problem in Model Quick View with Fabric Type displayed.Previously,
the group label was overlapped, now it is fixed.
9665 Corrected the problem that pieces may drop when landscape print.Now, both
portrait and landscape can correctly print pieces.
9152 Quick View with a model with several fabric types was not spacing the groups
properly on the page for Portrait printing. This has been corrected.

Page 39 of 51
Windows Vista

11220 Added support for DCU to run in on 64-bit operating systems.

12055 Corrected the case that system crashed when opening digitized data from SQL
storage area or subfolder in Vista.
9738 Corrected the crash problem when run AccuNest engine2 on Vista system.
Now,that engine can be compatiable with Vista operation system.
10292 In VISTA system, the default path for the Planner related files has been updated so
that the default Sample data can be opened from "C:\ProgramData\Gerber
Technology\GP2000\Data".
11788 OrderProc crashed during generate marker in SQL subfolder when working in Vista
system connecting with SQL Authentication to WebPDM database. This issue hase
been corrected.

WinPlot

7941 Corrected problem for some plt files plotting with WinPlot.Previously,winplot didn't
support IP and RO commands. Now,those files can be plotted correctly.
11067 Corrected the crash problem when plot invalid name file in Winplot.Now the error
message "Unable to load file.File does not exist" will be instead.
11574 Corrected the problem set media for multiplotter. Previously, Multiplotter does not
list created media in winplot. Now, after set the media and reboot, the media will be
list in winplot.

9176 Corrected the problem to correctly plot some special dxf files.Previously,some
entries in dxf files were placed at wrong position or misplaced. Now, it is fixed.
10414 Corrected the problem when plot an invalid file in WinPlot.Now,error message
"unsupported file type" will appear, instead of sending an empty plot file.
10430 Now when plot files by winplot without a plotter configured, it will give Plotter error
"Error 2 opening None". Previously it gave Runtime error and plotter.ini error.

Page 40 of 51
Pattern Design Software 8.4.0
Software Changes and Enhancements
Enhancement changes are documented in the What’s New document in the AccuMark LaunchPad and
the program folder.

Pattern Design Software 8.4.0


Pattern Design Changes

Alterations
16085 A previously opened ASTM file which contained some unsupported strings would cause PDS to
lose the Process Log. This problem has been fixed.
AM/MM Integration
15463 Added new selection in Standard DXF Export Option,now,Annotation and P-Piece-Plot fields are
active to select each storage area.
Assyst
15479 All text in the AccuMark family applications have been updated to use the font MS Shell Dlg to
help properly display non-English characters.
14303 Correct the issue of perimeter lines being distort at one side for symmetry pieces when importing
MDL files.
17276 Correct the issue that PX/PY value displayed several times in the steps when Record Script file
with Calculator and apply the value for many times. Now PX/PY in the step only record the last
values entered.
17164 Corrected a specific case that parts of size line seams could not be updated when used the
fuction Update Seam.
17245 Corrected an issue about MDL file importion that PDS would stop responding if the imported MDL
file contained dependency.
17206 Corrected an issue about MDL file importion that PDS would stop responding when imported
some specific Lectra data. Now this problem has been fixed.
17034 Corrected an issue that a special MDL file was imported to PDS with wrong direction of
grading(smallest size was outside,biggest size was inside).Now it has been fixed.
17243 Corrected an issue that create line offset uneven then swap would cause error. Now it has been
fixed.
17016 Corrected an issue that import AccuMark ASTM file could not create internal rule table for pieces
and would get wrong grading at mirror line. Now these problems have been fixed.
17002 Corrected an issue that import AccuMark ASTM file would get some corner notches shift in each
graded size. Now it has been fixed.
17005 Corrected an issue that importing AccuMark ASTM file would get some notches lost or with
wrong angles, now it has been fixed, all notches can be imported well.
17020 Corrected an issue that importing special MDL file would cause PDS stop responding.
17021 Corrected an issue that multi-operation of closing and opening work area with Current Pieces box
displayed would cause PDS stop responding. Now it has been fixed. Current Pieces box works
well to re-display or clear piece names when pieces are actived or inactived in work area.
17017 Corrected an issue that previously export AccuMark piece added with positive seam out as ASTM
file then import in would get some corner notches lost. Now it has been fixed.
17053 Corrected an issue that some MDL files would show wrong growths of Distance Points after
imported into PDS.
16375 Corrected an issue that some notches in certain graded sizes were graded incorrectly when
export AccuMark data out as ASTM/AAMA file then imported back into PDS.
16646 Corrected an issue that some notches would be imported to PDS with incorrect angle when
export AccuMark piece out as ASTM file then import back,now it has been fixed.

Page 41 of 51
15828Corrected an issue that some PAD ASTM/AAMA file would be imported with all notches
disappeared and only base size . Now it has been fixed, all size line and notches can be imported
well.
15571 Corrected an issue that using too long path to export AM modle as ASTM file would cause
PDS/DCU stop responding or path unable to read. Now it has been fixed.
15605 Corrected an issue when some Seam Corner Notches with either positive or negative seam
amount were removed after using Export AAMA/ASTM and then imported back into AccuMark
15522 Corrected an issue with AAMA/ASTM DXF file importion Process Log where "Std DXF" was
displayed in the first line instead of "AAMA/ASTM DXF".
Costing Marker
15785 Corrected an issue with Create Fusible where changing line to piece to create fusible then undo
would cause PDS stop responding.now this problem has been fixed.
16822 Corrected an issue with MDL file importion that PDS would stop responding if piece imported had
sepearte slide point on end of line in Lectra.
16442 Corrected an issue with Measure on mirror piece where the measurements would move from one
line to another after save/save as piece. Now it has been fixed.
16190 Corrected the issue of grading on some special pieces being incorrect when importing MDL files.
14932 Corrected the issue of notch shape displayed incorrectly due to an intermediate point.
Darts
12009 Corrected the issue of notch shape displayed incorrectly due to smoothing point.

DXF
14991 Corrected the issue of perimeter lines being unclipped when importing MDL files.
14990 Corrected the issue of shortening the piece name incorrectly when importing MDS files. Now it is
supported piece name length up to 20 chatacters.
16068 Corrected the issue of some special data didn't work with the function Process Costing Marker
when importing into a SQL storage area.
16329 Corrected the issue that the reference notch became into standard notch on mirror part.
15705 Corrected the issue that there were no prompt for the same size names but in different cases in
Measure Chart.
Edit
11268 In previous, Blend with a blended line in value mode, script will record the distance of the last line
and original line, but not the distance of two new lines. Now, it is fixed.
15588 In the Measure Chart the right mouse button option " Clear Selection" and the buttons"Yes/No"
were not translatable. This problem has been resolved.
Line
16556
If do the first fullness in value mode, then do the second, it will still be in curson mode. So, there
will be value in Dis and Ang, and will be OK if playback.
Plot-PDS
16199 Notches at mirror line of some pieces, which created by previous version, were not displayed.
This problem has been resolved.
16418 Now creating a line with the function Mirror, the grading of the new line will also be mirrorlike.
16813 Now when opening a closed dart, the drill hole will be removed.
17179 Now zero at the end will be removed for the values on Measure Chart Editor after click Enter
Point
13512 One-point internals or any two-point internals with the two points on top of each other cannot be
selected if Move Offset, Offset Even and Offset Uneven now.
13071 Pieces with darts including notches and drill marks were not created properly when data was
exported as AAMA/ASTM; notches were missing or on the wrong angle, and drill marks were not
graded properly. theses issues have been corrected.

Page 42 of 51
15129 Previosly , Edit Info Window would not be closed and updated after changing the filter options
and right click OK in workarea . This problem has been fixed.
14322 Previouly if only checked Toolbar in Screen Layout, this setting could not be saved. When
reopening PDS, Toolbar was missing. Now this problem has been resolved.
14214 Previouly PDS stopped responding when Move line on a drill during recording the script file. Now
this problem has been fixed.
17109 Previouly the distance between notches in a group would not be properly updated for Scale and
Shrink/Stretch. Now this problem has been resolved.
16460 Previouly, if a V-Stitcher model was imported and one piece had a different size line the work
area would display incorrectly.. Now this problem has been fixed and a warning is given : Size line
is different on piece.
16461 Previouly, there was no prompt for the base size missing when apply Action>Calculate Sizes on a
measure chart without base size. Now it has been resolved.
16430 Previously ,"*" can't be used for renaming piece when Play scripts. Now it has been resolved.
16175 Previously a savekey error would come up when Import/Export User Settings. Now this problem
has been resolved.
4086 Previously add Regular Corner with Extension notches on some specific pieces, when Save or
Save As the piece, it will cause the system to stop responding. Now this problem has been fixed.
15717 Previously all data conversions would convert the unsupported characters to "-", even it was the
first character of the data item name. This problem has been fixed. Now if the first character of the
data name is unsupported, it will be converted to "X" instead of "-".
15485 Previously Costing Marker didn't work with the model which name contained a underscore. The
activity log would show: The order XXX_XX does not exist. Now this problem has been resolved.
9475 Previously creating a horizontal line in Wizard with the function Digitized or 2 Point, when played
back it wouldn't keep the line hotizontal. Now this problem has been resolved.
12416 Previously if a tool was selected while the Custom Toolbar editor was open the system would
stop responding. This problem has been resolved.
12732 Previously if changed "Import File Path" in Preference/Options, the "Path" in Import Browser box
of the function Import wouldn't update immediately with the change. Now this problem has been
resolved.
10192 Previously if changed the options for Sleeve in the process of the function Armhole/Sleeve Cap,
the sleeve cap prompts would return to the armhole prompts. Now this problem has been
resolved.
Preferences
15649 Previously if entered the expression "-(10/2+20)" in the user input box, it would be treated as an
"invalid expression". This problem has been resolved. Now it can be used as a normal value.
16308 Previously if moved points on internal lines or on Grain Line with the function Move Point/Move
Single Point/Move Point Vert/Move Point Horiz, the movements was not displayed in the Value
Input box. This problem has been resolved.
16272 Previously if switched the pages in Preferences/Options, the combo box of "Plot Grade Sizes to
Use" in Plot(AM) page would display the list twice or more. Now this problem has been resolved.
16441 Previously if switched the pages in Preferences/Options, the combo box of "Quick Open" in
General page would display the list twice or more. Now this problem has been resolved.
16451 Previously in the Compass functions, the Left, Up, Right, and Down options could not be
translated into other languages. They are now translatable.
16605 Previously it didn't move the reference notch correctly when using the function Reference
Notch/Move with the option "Copy Distance". Now this problem has been resolved.
16603 Previously it didn't remember the settings of options in Offset Uneven. Now this problem has
been resoved.
16604 Previously minimize PDS window with an opened Grade Measure dialog box, and then resize it
back, some duplicate measurements would appeare in the box. Now this problem has been fixed.

Page 43 of 51
16582 Previously Notch Depth field in the function Add Notch would not reflect the actual notch depth in
the P-Notch table after PDS was just start up. Now this problem has been resolved.
16773 Previously opening pieces from AccuMark-Explorer, if the pieces were not from the Storage Area
which set in Preferences/Options, when View>Notch>Shapes in PDS, it would give an error
message "Error opening notch table P-NOTCH. No notch infomation for piece(s)". Now this
problem has been resolved.
16904 Previously PDS stopped the response when pull down pieces from piece icon during editing
script files. Now this problem has been fixed.
16907 Previously PDS would crash when draging the scroll bar in the print priview window. Now this
prolem has been resolved.
16866 Previously PDS would stop responding if export a rule table to \DXF\EXPORT folder with the
function Export Rules to RUL File. This problem has been resolved.
Print
15274Previously PDS would stop responding if selected Cancel in the process of creating a Knife Pleat
or a Box Pleat. Now this problem has been resolved.
Problem Report
16543 Previously PDS would stop responding if used Trace on a small piece with checking the option
"Maintain Graded Nest". Now this problem has been resolved.
17127 Previously PDS would stop responding when using Modify Curve on an unclipped line in clipped
mode. Now this problem has been resolved.
Seam
15835 Previously PDS would stop responding when using Swap Line at the lines with seams of some
specific data. Now this problem has been resolved.
17043 Previously PDS would stop responding when using the function Swap Line with checking the
option "Maintain Graded Nest" on a small piece. Now this problem has been resolved.
17081 Previously PDS would stop responding when using the function Tapered Fullness with some
specific data. Now this problem has been resolved.
17074 Previously PDS would stop responding when using Trace with the option "Mirror" on a nest piece.
Now this problem has been resolved.
17012 Previously Reduce Points with the option "N Attributes/Turn Points" or "S Attributes/Turn Points",
gave the incorrect results. This problem has been resolved.
16569 Previously seam corner displayed wrong on long perimeter line when add Bisect Step Corner and
Slant Step Corner on two sides. Now it has been resolved.
16586 Previously Snap to Geometry ON didn't save when close and reopen PDS. Now this problem has
been fixed.
16781 Previously some Japanese characters were displaying incorrectly in the piece name field and for
piece annotation. This problem has been resolved.
16887 Previously Swap Line and Replace Line would make reference notches (include tangent notch)
move in Unclipped mode. This problem has been fixed.
16783 Previously the changes on filter option were kept though click Cancle for Edit
piece/point/line/notch infor. Now this problem has been fixed.
16328 Previously using Plot with Plot Form, if closed Plot Form window when no work area was opened,
PDS would stop responding. Now this problem has been resolved.
16298 Previously using the function Process Costing Marker, if Quantity or Width filed is blank in
Costing Marker dialogue box, click OK, it would give the same prompt window twice. Now this
problem has been resolved.
16365 Previously using the function Reshape Curve, if selected the lines in wrong order, when Undo it
would reposition the pieces. Now this problem has been resolved.
16000 Previously when browsing path in Preferences/Options, it was unable to recognize the path
contained dot. Now this problem has been resolved.

Page 44 of 51
16108 Previously when creating a line by using the function Digitized with the option "Line" or "Curve"
from the "right menu", if placed a point with the option "Horizontal/Vertical/Perpendicular to last
segment/Along last segment", the radio button would go back to "Normal" but its functionality was
still sticky. Now this problem has been resolved.
15978 Previously when creating a wizard, Perp Point Off Line did not create point number on newly
created line. This problem is now resolved.
15778 Previously when importing an invalid User Settings into PDS, it would cause PDS stop
responding without any warnings. This problem has been resolved. Now it will show the progress
bar and finally gives the success or failure message.
3531 Previously when importing ASTM data and the import process fails to build a graded nest and
imports each individual size as a separate piece, sample size was assigned for each piece all
sizes. Now this problem has been fixed. I will assign the appropriate size for each individual size
piece.
14637 Previously when importing ASTM/AAMA file, it would sort the pieces alphabetically. Now the
pieces are using the order they appear in the ASTM file.
15587 Previously when importing DXF files which created in Cutworks Designer, notches were ignored.
Now this problem has been resolved.
15590 Previously when moving a drill hole with the function Move Single Point or Move Point, the value
of the movements didn't display in the Value Input box. Now this problem has been resolved.
15473 Previously when moving point(s) on a Draft Piece with the functions Move Single Point/Move
Point/Move Pt Line Slide/Move Point Horiz/Move Point Vert, the movement of the point(s) was
invisible. Now this problem has been resolved.
17259 Previously when ploting pieces with the function Plot Altered, if selected "Nested" as Preference,
the last selected size in the size list would not be plotted. Now this problem has been resolved.
17189 Previously when prompted for the point to move in Armhole/ Sleeve Cap, unchecking the "Create
Composite Line" option, PDS would stop responding. Now this problem has been resolved.
17061 Previously when using Armhole/Sleeve Cap with the option "Move Smooth Line", it didn't take the
same movements for armhole and sleeve cap. And the pieces would be distorted after clicked OK.
Now this problem has been resolved.
16660 Previously when using Copy Grade Rule, if selected multiple target points by using marquee box,
it wouldn't make grade reference line to the selected one. Now this problem has been resolved.
16567 Previously when using Flatten Line Segment on an open dart which had a few points on the legs,
PDS would hang and eventually crash. Now this problem has been resolved.
15007 Previously when using Move Point in some specific cases, PDS would stop responding. Now this
problem has been resolved.
TIIP
14006 Previously when using Move Pt Line/Slide on a digitized line in value mode, the line length would
not change to the entered value. This problem has been resolved.
15377 Previously when using Record from the Wizard menu with the functions Digitized, 2 Point, 2
Point-Curve, Perp on Line, Perp off Line, Perp 2 points, it would also record the option "Add
Grade Rules on Intersections". This problem has been resolved. Now the option "Add Grade
Rules on Intersections" in these three functions is inactive when Record.
16930 Previously when using Replace Line with an internal line which had several intersections with the
perimeter, PDS would stop responding. Now this problem has been resolved.
Translation
15553 Previously when using Reshape Curve, if selected the split point to move, finally it would make
the piece to be a point. This problem has been fixed. Now it will give a message "Lines need to be
selected in clockwise order." when the user make a wrong selection.
15558 Previously when using the function Adjust Length on an internal line with a notch at the endpoint,
if selected the notch to shorten, it would cause PDS to stop responding. This problem has been
resolved.
15567 Previously when using the function Move Point in cursor mode, if selected multiple points to move
(including points on internal lines), the X and Y fields would be blank. This problem has been

Page 45 of 51
resolved.

17091 Previously when using the function Offset Even, if moved a line pass a split point with checking all
the options, and then repeated the same behavior with unchecking all the options, PDS would
stop responding. Now this problem has been resolved.
15288 Previously when using the function Plot, Cut or Swap Sew/Cut, the notch which was on a step
corner would change the notch angle. Now this problem has been resolved.
16784 Previously when using the function Rotate Piece, if selected a drill point as pivot point, PDS
would stop responding. Now this problem has been resolved.
16724 Previously when using the function Save, it would save a piece with invalid piece name "-" without
any warning. This problem has been resolved. Now it isn't allowed to start a piece name with "-".
16792 Previously when using the function Taper Slash n Spread, some internal lines didn't move
following the guide. Now this problem has been resolved.
16909 Previously, Edit Delta worked with wrong values on pieces with stacking 2 points . Now apply
Edit Delta, Edit Offset, Create Delta, and Create Offset functions on a piece with stacking 2 points,
the grading is changed with right values entered.
16922 Previously, an extra area was added to the edit dialog when the steps and details sections were
hidden. This problem is now resolved.
16726 Previously, an extra checkbox displayed on the left top of the File>Open dialog. The checkbox
has been removed.
16753 Previously, an mdl file with constraints would cause an error if opened in PDS. This problem is
now resolved.
16733 Previously, angle of notch would be incorrect if import special mdl file. Now, it is fixed.
16709 Previously, Armhole/Sleeve Cap with "Create Composite Line" and "Move Smooth Line" would
cause PDS to stop responding. This problem is now resolved.
16385 Previously, Armhole/Sleeve Cap with Sleeve:Mv Sm Line(-) cause crash. Now, it is fixed.
16708 Previously, Chinese character would be cut to '?' if open mdl file with piece name more than 20
characters. Now, it is fixed.
13437 Previously, Circle could be created with more than 20 characters as name , then PDS stopped
response. Now this problem has been resolved.
14053 Previously, Combine/Merge the two pieces with the same line in different sequence get different
result. Now it is fixed.
15181 Previously, Costing Marker would cause PDS to stop responding when run with a model that had
a name with more than 18 characters and process with the fabric type. Now this problem has
been fixed.
15192 Previously, create different line name if playback script with Rotate Dart. Now, it is fixed.
15183 Previously, Description of Chinese characters would be missing if Edit Piece Info in JP OS. Now,
it is fixed.
15117 Previously, drills could be added in space not relatiece to piece, even if the warning 'Point needs
to be relative to the piece' was displayed. This problem is now resolved.
User Interface
15189 Previously, error come out if play script with first point of value for 'Loc'(like:PD(0)). Now, it is
fixed.
14925 Previously, error 'Unreconized character (,) token in the formula' come out if Calculate with
comma when Record script in German system. Now, it is fixed.
14296 Previously, Export Standard DXF would sometimes fail and not display the process log. This
problem has been resolved.
16590 Previously, Exported some special data as ASTM with 'Export Perimeter as One Line' checked as
nest, then imported again, would get wrong grading. Now, it is fixed.
16501 Previously, exporting to a DXF file would cause a warning that said the plot file already existed.
This warning has been removed.

Page 46 of 51
16643 Previously, if ASTM file contained both Graded Nest and External Rul file references,this ASTM
file would be imported with one piece per size. Now it has been fixed, this kind of ASTM file can
be imported as One Graded Piece.
16855 Previously, if do Taper Slash n Spread or Parallel Slash n Spread with two pieces, select first
point of the slash line on one piece, then press Tab to select the first point of the latter slash line
on another piece, PDS would close. Now, it is fixed.
15608 Previously, if import the AAMA/ASTM data with the rule table with the name more than 6
characters, pieces cannot defined correct Rule Table. Now, it is fixed.
15570 Previously, if Move Pt Line/Slide with the end point of the line in draft piece in value mode, PDS
will crash. Now, it is fixed.
View
15031 Previously, if Record 'Move Point Line/Slide', the line name would be changed later, but then if
edit the line, script would be record with the original line name, and this would cause PDS close if
playback. Now, it is fixed.
14004 Previously, if record Rectangle, Circle, Oval, Facing, Fusible, Binding, Ruffle, Copy, Trace with
'Add piece to Modle' with measurechart, then playback in new workarea, keep clicking 'Cancle'
when prompt to enter new piece name, PDS would crash. Now, it is fixed.
16428 Previously, if selected line to move with function Make Paralell or Make/Move Parallel, then scroll
mouse to change the piece scale on workarea, PDS would crash. Now, it is fixed.
16429 Previously, if Verify digitized data of mirror piece, angle notch would change its angle. Now, it is
fixed.
16716 Previously, Import some mdl file, line of one side of mirror piece would change it's shape. Now, it
is fixed.
16801 Previously, in the Skirt and Oval functions, if an invalid value was entered in the field "Dist
Between" PDS would stop responding. This problem is now resolved.
15376 Previously, 'Intersection error' would display if show all sizes with some piece. Now, it is fixed.
17106 Previously, it displays "--" if enter negative value when Add Point with tangent option. Now, it's
fixed.
16914 Previously, it is record wrong in script if select or not select N Attribute when Add Point, Mark X
Point, Reduce Point, Combine/Merge. Now, it is fixed.
17045 Previously, Matched Seam Corner of the biggest size of some piece will get distort in Piece-plot,
PDS-plot, Mark Making and Marker-Plot. Now, it is fixed.
17182 Previously, Measure Line from calculate would always measure the complete line length, even if
Perimeter Mode had been set to Unclipped. Now, it is fixed.
15568 Previously, Mirror line was extended if Unfold Mirror with the notch on the end of mirror line. Now,
it is fixed.
15630 Previously, mirrored Piece did not show Tangent Notch and Reference notch when unfold or fold
back piece in PDS. Now it is fixed and displays well.
V-Stitcher
16622 Previously, if pieces with different size lines were selected for the Grade/Measure functions, PDS
would stop responding. This problem has been resolved and the functions now give an error
message.
16630 Previously, if record any function with calculate in front of the first step when edit script with
measure chart, measurement would disappear in measurt chart. Now, it is fixed.
16633 Previously, if record applying Line>Curved Intersection on rectangle piece with 'All Perimeters'
and 'Add/Change Radius', or, 'All Perimeters' and 'Add Severed', or, 'Internals' and 'Add Severed'
options checked, save the script and play it back on the same piece, PDS would close. Now, it is
fixed.
13841 Previously, if Record Fusible with two pieces at the same time with some measurement, then
Play back with nest, the nest of the pieces will display wrong. Now, it is fixed.
Wizard
14971 Previously, Move Offset with Cursor Mode can not be played back correctly. Now, it is fixed.

Page 47 of 51
14594 Previously, Move Smooth Line, Move Pt Line\Slid using calculator with measurement functions,
chart values and formulas, the calculator function couldn't be record in script. Now, it is fixed.
14649 Previously, Notch will not keep same distance on negative seam if Add Seam with Seam
Extension. Now, it is fixed.
14450 Previously, Notch with point type 9 in Lectra placed on incorrect position of piece if open directly
in PDS or convert with LConvert. Now, it is fixed.
15079 Previously, notch would come out if save some piece with Squared Corner added with None
Notch. Now, it is fixed.
15322 Previously, Notches can not be added on both sides of the lines notched if add Mirror Corner or
Turnback Corner, and notches can not be added with different informations if add Match Squared
Corner or Match Seam Corner. Now, it is fixed.
15196 Previously, notches on Squared Corners would be lost if Copy Piece no Seam. Now, it is fixed.
15197 Previously, notches would be lost if save some piece. Now, it is fixed.
15004 Previously, 'Out of Memory' would display if do Fusible with more than 5 pieces Set Selected or
just maquee select the pieces. Now, it is fixed.
14277 Previously, PDS cannot keep the interface of toolbar if reopen PDS with AccuScan toolbar. Now,
it is fixed.
14468 Previously, PDS crashed if Measure piece with number of sizes more or less than the number of
sizes in the chart. Now, it is fixed.
14465 Previously, PDS stopped response if apply another fucntion during add Envelope Corner and
show warnings for the Preference.Now it has been resolved.
14551 Previously, PDS would close if import mdl data with incorrect seam display. Now, it is fixed.
14671 Previously, PDS would close if import some mdl file. Now, it is fixed.
14268 Previously, PDS would close if open mdl file with no end point of the line. Now, it is fixed.
14220 Previously, PDS would close if play incomplete script 'Rotate Line'. Now, it is fixed.
15984 Previously, PDS would close if Play Swap Line with selecting internal line as perimeter, or
selecting perimeter line as internal line. Now, it is fixed.
16016 Previously, PDS would close if select notch point when Perim Pt Fold with some data. Now it is
fixed.
16018 Previously, PDS would crash if drag second piece from piece icon when Edit script. Now, it is
fixed.
13883 Previously, PDS would stop responding if a perimeter line was selected as an internal line in
Extract Piece. This problem is now resolved.
12953 Previously, PDS would stop responding if a PLT file that had a name with more than 19
characters was imported. This problem had been resolved.
13390 Previously, PDS would stop responding if all interenal lines were selected by selecting the piece
when playing the script. This problem has been resolved.
16552 Previously, PDS would stop responding if import some special MDL files. now it has been fixed.
16448 Previously, Piece mismatched if Check Grade with piece '7737TE-COSTD' and 'TANIA ESP'.
Now, it is fixed.
16412 Previously, piece would get wrong perimeter sharp if import mdl file. Now, it is fixed.
16322 Previously, play back Move Smooth Line get wrong result if Input value with Beg after move
thumbtacks. Now, it is fixed.
16387 Previously, play some special script, graded points on curve would move, and the line
measurements would be different. Now, it is fixed.
16307 Previously, playing a script with Delete Piece From Work Area, then using Undo twice would
cause PDS to stop responding. This problem has been resolved.
16320 Previously, Plot Altered didn't plot the altered shape. Now, it is fixed.
16557 Previously, Point>Move Smooth,Point>Move Smooth Line,Point>Move Smooth Horiz,Point>Move
Smooth Vert,Line>Move Range,Line>Modify Curve don't work with end point of internal line if
playback script. Now, it is fixed.

Page 48 of 51
16512 Previously, Porcess Cost Marker failed if Laylimit and Annotation include Chinese Characters in
the name for the costorder. Now it has been resolved.
16558 Previously, Record script with Move Smooth, Move Smooth Line, Move Smooth Horiz, Move
Smooth Vert in AE were record differently from PE and could not be played back well in PE. Now,
it is fixed.
16573 Previously, Record two point curve with the right mouse button option along midpoint
perpendicular, curve point value for loc was record with X and Y value. Now, it is fixed.
16579 Previously, Reference Notch just appeared only one side of mirror piece when imported mdl file.
Now, it is fixed.
16497 Previously, reference notches move with reference point is seam corner point if Show Actual
Sizes+Alterations or plot Altered or plot marker with altered piece. Now, it is fixed.
16818 Previously, reference notches moved on seam of altered pieces. Now, it is fixed.
16829 Previously, script playback not correctly if Rotate Dart with select the new apex point. Now, it is
fixed.
16831 Previously, script run with error if set Regional setting to Netherland-Belgium in Dutch system and
change decimal to '.'. Now, it is fixed.
16585 Previously, seam would be distorted if import some special mdl data. Now, it is fixed.
16677 Previously, selecting end points of Turnback corners on special piece to Split Piece>Point to
Point would cause PDS stop responding. Now this problem has been fixed.
16931 Previously, SelReferenceLoc, MoveMultiLineInReverse and PerNotch don't display when record
Move Offset or Offset Even if all the options are selected. Now, it is fixed.
16937 Previously, SHIFT + 3 was the hotkey for Intersect Parrallel. Rule numbers with '#'s could not be
entered. The hotkey for 'Intersect Parrallel' has been changed to Shift+6.
16943 Previously, size line is lost when export Measure Chart. Now it is fixed.
16944 Previously, Slant Step had been imported as Bisect Corner if import mdl file. Now, it is fixed.
16946 Previously, some Adobe DXF files could not be imported due to improper formatting. This
problem has been resolved.
16895 Previously, some cut line of piece with no seam defined could not be plot. Now, it is fixed.
16896 Previously, some DFX files exported by Lectra in an incorrect format could not be opened in PDS
directly. This problem has been resolved.
16897 Previously, some Point ID was very big when import MDL file. Now, it is fixed.
16877 Previously, some special related points of mdl data would cause PDS closed. Now, it is fixed.
16878 Previously, Squared Corner would be lost if Change Base Size, then Change Base Size back
again. Now, it is fixed.
16842 Previously, strings of unit of Import AAMA/ASTM and Export Standard DXF are missing in
translation package. Now, it is fixed.
16844 Previously, Tangent Notch displayed on the incorrect position if Export as AAMA or ASTM. Now,
it is fixed.
16845 Previously, the quick keys for Offset Even, Tangent Off Line, Circle Ctr Cirm and Curved
Intersection were the same. Now the functions have unique quick keys.
16849 Previously, the seam corner on piece was incorrect when import Lectra MDL file. Now it is
converted well with the right shape.
16814 Previously, the uneven seam on piece displayed wrong or distorted when import Lectra MDL file.
Now it has been resolved.
16865 Previously, there is one more check box on the open dialog of Edit Model. Now, it is moved away.
16833 Previously, There were no prompt for unavaliable rule table and still displayed successfully in
process log. Now it has been resolved with error message in red.
16836 Previously, using Zoom In/out by the wheel of the mouse during the process of Fold Keep, PDS
stopped responding.Now this problem has been resolved.
16823 Previously, Value of Smooth Facter of Smooth stay as 4e-006. Now it is removed, and shows
correct value.

Page 49 of 51
16837 Previously, V-Stitcher closed if import model from SQL storage with long path more than 30
character . Now it has been resolved.
16843 Previously, when creating a new line using right mouse button Horizontal or Vertical, the script
would record both the right click and the percentage of the line, but playback just performed the
percentage. This problem is now resolved.
16903 Previously, when creating a script, ranges were not recorded when the pushpins were
repositiond. This information is now recorded for the following functions: MoveLineAnchor,
MoveSmoothLine, AlignPoints, Armhole SleeveCap, ModifyCurve, ReshapeCurve, Move Smooth,
Move Smooth Horizontal, and Move Smooth Vertical.
16668 Previously, Wizard Calculator removed decimal point for the value if use the key on the mainarea
of the keyboard. Now it has been resolved.
16481 Previously, zero displayed with the diffrent way when apply Action/Edit growth amount on
Measure Chart Editor. Now it has been resolved and display the integer.
16618 Previously,apply Offset Uneven on a drill or a space point, PDS stopped the response. Now all
one-point internals (label 'D' and different label) can no longer be selected in the Offset Even and
Offset Uneven functions.
16030 Previously,if Auto Update Seam was ON,Combine/Merge these multiple lines whose seam
allowance were overlapping each other would cause PDS stop responding. Now it has been fixed.
16155 Previously,if the piece contains two alt grade linges and G0 has end points with grade rule,export
it as ASTM file then import back would get wrong graded shapes.Now it has been fixed. Export
Graded Nest can get right shapes without grade rules on G0 endpoints. And export with Rul file
can maintain grade rules on G0 endpoints.
15325 Previously,importing AccuMark Marker as standard DXF with PDS and DCU would get different
displays of marker and some internals were missing. Now this problem has been fixed.
15380 Previously,importing Assyst design files to PDS would get some unexpected lables which were
not defined in Assyst Import Option.Now,this problem has been fixed.
15267 Previously,improper operation of P-Notch would get misspelled error message"Error opening
notch table P-Notch. No notch information for piece(s)." Now this message has been modified
as"Error opening notch table %1 in %2 storage area %3." where %1 is the Notch Parameter Table
name, %2 is the device name and %3 is the storage area name.
16205 Previously,PDS stopped the response when apply Match LineX/Y on draft piece in Clipped
Perimeter Mode .Now It's fixed with Match LineX/Y function disable for draft piece.
16305 Previously,PDS would stop responding when some special MDL files were imported. now this
problem has been fixed.
16402 Previously,Save some Micromark data as MicroMark style and export rules , system would stop
response. This problem has been fixed now.
16230 Previously,some TIIP DXF files caused PDS crash with option "One Graded Piece ". Now it has
been fixed.
15692 Previously,unsupported characters in item names would be imported different. Now,for all kinds
of data,the first unsupported character in item name will be replaced with 'X' and others replaced
with '-'.
15684 Previously,View\Notch\Shapes would cause PDS stop responding if the default Notch Parameter
Table does not exist. Now it has been fixed.
17148 PreviouslyŒ92 Calculate Sizes updated the values on all the rows. Now it has been fixed that it
will updated the selected row or the row that current cell is in if no row is selected.
16976 Resource strings have been updated to use positional arguments making it better for the string
substitution parameters to work with translated text.
16977 Reviously, some notch would be lost if Flip Piece. Now, it is fixed.
16974 Some notches on the seam line of the pieces, which created in previous version were displayed
incorrectly. Now this problem has been resolved.
17103 Some of the menu items of the Classic AccuMark menus were displayed incorrectly. This
problem has been resolved.
17060 The display of fonts in the Pattern Wizard were incorrect in many areas for Japanese. This

Page 50 of 51
problem has been resolved.
17260 The error "unsupported transpo record XXX uses unimplemented transforms" is corrected into
warning.
17038 The 'G' has been removed from the toolbar.
15561 Tool tips were not displaying in the Pattern Wizard forms. Tool tips now display for the toolbars.
15632 Using Zoom In while in Offset Uneven would cause the system to prompt for a value before a
point was selected. This problem has been resolved.