IMPERIAL TEAS GROUP
Environmental Monitoring Plan
DOCUMENT NO. IMP – R - 098 ISSUE NO: 00 REVIEWED BY :
REVISION NO: 00 REVISION DATE: 2021.02.15 ISSUE DATE: 2021.02.15 APPROVED BY:
Test Frequency Locations Test Test Method Due Date Regular Contact Contact E-mail Address
Parameter organization
Potable Water Annually Hand washing tap. PH APHA 4500- 03/July Microchem Services (Pvt) microchem@sltnet.lk
H+ Ltd
Electrometric
method
Free residual APHA 4500 cl:
Chlorine DPD
Colorimetric
method
Total SLS 1461:
Coliform Part1/Section
3:2013
E.coli SLS 1461:
Part1/Section
3:2013
Swab Testing Annually Hand swabs from direct Aerobic plate ISO 4833- 03/July Microchem Services (Pvt) microchem@sltnet.lk
tea handlers (Person count 1:2013 Ltd
from tea feeding point,
person from manual Yeast & SLS 516: Part2
packing, person from Mould count :1991
blending area)
Air Quality (Tea direct
exposing areas such as
manual packing area,
blending area, tea
bagging area)
IMPERIAL TEAS GROUP
Environmental Monitoring Plan
DOCUMENT NO. IMP – R - 098 ISSUE NO: 00 REVIEWED BY :
REVISION NO: 00 REVISION DATE: 2021.02.15 ISSUE DATE: 2021.02.15 APPROVED BY:
Swabs from tea direct
touching areas such as
tea tipping hopper, tea
storing bins, feeding
hopper, blending
machine, conveyors)
Treated Waste Annually Final discharge point of PH APHA 4500- 10/July Global Scientific Mr. Chaminda H.
water treatment plant H+B Laboratories (Pvt) Ltd (coordinate & done by
Mr. Chaminda)
BOD APHA 5210- B
COD APHA 5220- B
TSS APHA 2540- D
Oil & Grease APHA 5520-B
Fecal SLS 1461: P1 :
coliform Sec 3: 2013