Ecklin Generator Experiment For this experiment, we used the stator from a 25 horsepower motor with alternate poles removed. Thus there were 12 active poles. The rotor from a 1 horsepower motor had its coils removed and the Core machined so it resulted in 6 poles. The the rotor laminations Were not insulated perfectly. There could have been a shot circuit under stress, For a driver, we used a 600 Watt series motor. This was regulated with a triac (light dimmer) so we could try the experiment oe Speeds up to 10,000 R.P.M. With the output short circuited, the load on the motor decreased, which resulted in a speed increase. With the output unloaded, the generator was difficult to control and the motor required full’ power. With a pure ohmic load resistance of the same resistance as the generator, the output was @ reasonably low load to the motor (about 200 W). We then used about 96 W for magnetization and got 80 W out. The ghmic load was composed of a combination of heating elemencs and. lamps. By increasing the magnetic field to around 12,000 ampere-turns for the whole generator, this effect decreased. The input poles were then connected in different ways. This Tpsulted in some connection configurations receiving power from a 12 V lead-acid battery. At no time did we get more energy out of the generator than we put into it. Arhus ds 22/6 1985 Forseg med Ecklin generators Til forsaget, benyttede vi statoren fra en 0,25 HK r ae motor. hvor hver anden! pol dlev/fjernet. Der var s& falt 12 poler tiJbage (vist pA flour (ds -Rotoren blev drejat2so ¥ ned af et kortslutningsanker fra en | Hk, motors ‘og ud- i Yow frest 84 der dannades 6 odler. Lasmellerne { rotoren var ivke {solerede nerfekt. De kan have veret Kortsluttet ved 1 oa ui fresninaen. | / ) Som drivmotor bruate vi en 600 4 saptemotor enne =F styrede vi med en triac (lysdemoer). s4 vi kupne drave onstillingen ved forskelliae bast lohedet fon til 10.000 omd./mins { wo Es | | ved kortslutning af | woanaens falot belastningen at motoren, hvilket bevirkede is at dendlabsop { ont 1 a i Ved uoelastet udaang var ADRES cay svanattrekke. 09 ninger. ij motoren trak fuld «strom, mens der ved en-rery chmsk be- lastning med samme modstand som generatorudaancens var en rimelig lav belastning af motored (omkring 200 Wi. Vi maqnetiserede da med omkring 96 W, oa fik BO Wud. Den ohmske belastnina bestod af kombinationer af varmelzgemer og Llamoer. Ved overm# tet maanetfelt. omkring 12,000 amoarevin= dinger for hele generatoren, faldt virkninasoraden. In- putsoolerne. der blev koblet 04 forskellige mader Veh.as Neale kantkonektore, fik stram fra en 12 V blyakkumula- tor. Vii fik pa intet tidspunkt mere energi ud af genera- toren, end vi tiltorte den. Ole Nilsen VN ene vending Stater 12 poler Reter 6 peter Polbredde pa stator: rm SS ee

You might also like