SERVICE MANUAL NUMBER 14 TROUBLESHOOTING

Trim UP/OUT Switch Inoperative In Manual Trim Control

TRIM DOWN/IN SWITCH FUNCTIONS, AUTO MODE FUNCTIONS PROPERLY

Cause Special Instructions

Trim 20 amp fuse “43” blown (if equipped). Determine cause for blown fuse and
correct before replacing fuse.
Check voltage at terminal 44. If no voltage
Open in power supply lead to trim and is indicated, check lead 45 for a poor
trailer switch.
connection or damage.
Faulty trim UP/OUT switch (applies only to
Check for voltage at terminal 40 while
trim controls where it is necessary to
actuating trim UP/OUT switch. Replace
actuate trim UP switch in order for trailer
switch if no voltage is indicated.
switch to function).

Trailer Switch In Manual, Trim Control Inoperative

TRIM UP/OUT SWITCH FUNCTIONS

Cause Special Instructions


Check for voltage at terminal 41 and 42
while actuating trailer switch. If voltage
exists at terminal 42, but not at terminal
Faulty trailer switch.
41, a faulty switch is indicated. If no
voltage exists at terminal 42, check power
supply lead for an opening.

Opening in wiring. Check lead 39 for damage or a loosened


or corroded connection.

Boat Is On Plane Well Before Drive Unit Begins To Trim Out


Cause Special Instructions
Control module adjustment incorrect. Adjust. (Refer to SECTION 5)
Faulty control module. Replace control module.

Boat Is Not On Plane Before Drive Unit Begins To Trim Out


Cause Special Instructions
Control module adjustment incorrect. Adjust. (Refer to SECTION 5)
Faulty control module. Replace control module.