You are on page 1of 14

LOCAL AND REMOTE CONTROL UNIT

FOR TYPE 1A + 1R PUMPING STATIONS


LOCAL AND REMOTE CONTROL UNIT
FOR TYPE 1A + 1R PUMPING STATIONS
Contents of the presentation:

1. PURPOSE OF THE WORK


2. EQUIPMENT OF A PUMPING STATION
3. PROPOSED SOLUTION
4. DEVELOPMENT OF A SOFT COMFORT LOGO
PROJECT
5. CONTROL AND MONITORING OF PARAMETERS
THROUGH THE CMR2020 COMMUNICATION
MODULE
6. Conclusions
LOCAL AND REMOTE CONTROL UNIT
FOR TYPE 1A + 1R PUMPING STATIONS
1. The purpose of the paper
LOCAL AND REMOTE CONTROL UNIT
FOR TYPE 1A + 1R PUMPING STATIONS
2. Equipment of a pumping station
LOCAL AND REMOTE CONTROL UNIT
FOR TYPE 1A + 1R PUMPING STATIONS
2.1 Automation panel

Fig. a Exterior view Fig. b Interior view


LOCAL AND REMOTE CONTROL UNIT
FOR TYPE 1A + 1R PUMPING STATIONS
2.2 DAB electronic pump, EVOSTA 40-70 / 130



LOCAL AND REMOTE CONTROL UNIT
FOR TYPE 1A + 1R PUMPING STATIONS
2.3 EXPERIMENTAL STAND

The control panel,


pumps and water
basins are
attached to the
experimental
support.
LOCAL AND REMOTE CONTROL UNIT
FOR TYPE 1A + 1R PUMPING STATIONS

3. THE PROPOSED SOLUTION


LOCAL AND REMOTE CONTROL UNIT
FOR TYPE 1A + 1R PUMPING STATIONS
4. Develop a project in SOFT COMFORT LOGO

The following shows how the


control blocks for the pumping station
equipment were created, along with
the I / O settings. An FBD Function
Block Diagram programming language
was used to develop the software.
LOCAL AND REMOTE CONTROL UNIT
FOR TYPE 1A + 1R PUMPING STATIONS
4. Develop a project in SOFT COMFORT LOGO
LOCAL AND REMOTE CONTROL UNIT
FOR TYPE 1A + 1R PUMPING STATIONS
4. Develop a project in SOFT COMFORT LOGO

• EQUIPMENT OPERATION SIMULATION, WITH THE HELP OF THE LOGO SOFT CONFORT
PROGRAMMING SOFTWARE
LOCAL AND REMOTE CONTROL UNIT
FOR TYPE 1A + 1R PUMPING STATIONS
5. GPS / GPRS control
LOCAL AND REMOTE CONTROL UNIT
FOR TYPE 1A + 1R PUMPING STATIONS
6. CONCLUSIONS

1. The need to improve and optimize technological processes has led to the implementation of advanced control
strategies.
2. In the automation of a pumping station, certain steps must be taken into account in the design of the control
system.
3. Programming a station via a PLC can be done using several programming languages (LAD, STL, FBD, etc.). Using
a different programming language can be an opening for another stage.
4. The supervision of the pumping stations helps to monitor the specific parameters in order to make a decision
regarding the technological process.
THANK YOU FOR YOUR ATTENTION !