You are on page 1of 4

MRU – Competence in gas analysis. For more than 35 years.

FSM
Particulate Matter
Measurement
Precise – Robust – Reliable
Particulate matter
measurement
The 3-component-system
Your advantages:

� Very reasonable in price and easy to maintain


� precise standard-reference-measuring methode (gravimetrically)
� extremly robust components
� reliable and secure evaluation unit (scale) for the office
The components in detail

Measuring- and control unit


The proven , multifunction measurinf device SPECTRA/
OPTIMA controls all processes of the particulate matter
measurement and in addition it provides the required flue
SPECTRA or gas test results.
OPTIMA

Case for collecting particulate matter FSM


The FSM case is a compact an d robust module for
collecting particulate matter. It loads the filter catridges
with particulate matter for evaluation.

Weighing and drying modul, FSM scale

The special scale weighs and drys simultaneously and


transmits the results to SPECTRA or OPTIMA.

� Scale also suitable to measure


humidity of pellets!
FSM-System
Technical Data
Particulate matter probe
Length of probe tube 300 mm
Diameter of probe tube 10 mm
Length of sampling hose 4m
Filtertemperature in the probe regulated 70 °C
Material of probe stainless steel/PTFE
Material of filter Borosilicate

Measuring results (particulate matter in flue gas)


Measuring principle gravimetrically
Measuring range 0 ... 1000 mg/Nm3
Averaging time 15 min
Accuracy of filter weighing < 1 mg
corresponding to mass concentration < 5 mg/m3

Calculated values Total


Total volume collected
Collection time 15 min
Conversion to normative 0 °C, 1013 hPa
Accuracy ± 5%
Average content of oxygen
Averaging time 15 min
Average content of carbon monoxide

Technical data sublect to change without notice. | * higher value is relevant | N-64524EN-K0-0M-0322
Averaging time 15 min
Conversion to content of reference oxygen �
Content of particulate matter in flue gas
Conversion to reference oxygen �

General data SPECTRA/OPTIMA FSM-case FSM-scale


Operating temperature +5°C ... +45 °C +5°C ... +45 °C +15 °C ... +30 °C
Storage and transportation temperature –20 °C ... +50 °C –20 °C ... +50 °C –20 °C ... +50 °C
Humidity 95 % 10 % ... 70 % 10 % ... 70 %
Number and type of batteries LiIthium Ion 0 0
Housing material PA6 Aluminium ABS
Weight 0,75 kg 9 kg 4,8 kg
Dimensions/ mm 244 x 113 x 54 mm 470 x 230 x 315 335 x 210 x 158
Sample gas
Flow (dry, 0 °C) 1 l/min 13 ln/min
Flow regulation (differential pressure measurement) �
Accuracy of flow regulation ± 5%
Max. flue gas temperature, depending on humidity 350 °C

MRU – Competence in gas analysis. For more than 35 years.

MRU · Messgeräte für Rauchgase Sales and Service:


und Umweltschutz GmbH
Fuchshalde 8 +12
74172 Neckarsulm-Obereisesheim
Fon 07132 99620 · Fax 07132 996220
info@mru.de · www.mru.eu