pump. which are used in swimming pools and garden ponds, and
v Keep these operating instructions in a safe place. equipped with firm power cable should be fed via an ÖVE
approved isolating transformer – rated voltage must not exceed
s.
Contents 1. Applications Range of Your GARDENA Pump . . . . . . . . . . . . . . . . 10 230 V.
2. For Your Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
al
In Switzerland In Switzerland mobile appliances which are used outdoors,
3. Initial Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 must be connected via a residual-current device.
4. Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
u
5. Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Mains power According to DIN VDE (German Electrical Engineers’ Associa-
an
6. Trouble-Shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 tion) 0620, mains power cables must not have a smaller cross-
7. Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 section than the rubber-sheathed cables of the designation
H05 RNF (model 9000 S Inox) or H07 RNF (model 15000 S / SP
8. Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
em
Inox). The cable length must be at least 10 m.
9. Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Data indicated on the type plate must match technical data of
the mains supply.
1. Applications Range of Your GARDENA Pump v Take care that the electrical connections are made within dry
ic
area, protected from flooding.
Protect plug and power cable from heat, oil and sharp edges.
ev
Intended use GARDENA Pumps have been designed for private use around
your house and garden. They are predominantly destinated for v Don’t use the power cable for plugging off.
drainage after flooding, transfer of liquids, draining containers, tak- The power cable or the float switch must not be used for mount-
.d
ing water from wells and shafts, draining boats and yachts as well ing or relocating the pump. For submerging or lifting / securing
as for water aeration and circulation for a limited period of time. the pump, fix a rope to the pump’s carrying handle.
w
Liquids to be pumped Liquids which can be handled by the GARDENA Pump are the Extension cables must meet the requirements of DIN VDE 0620.
following: clean and slightly contaminated water (max. particle size
w
9000 S Inox = 5 mm / 15000 S / SP Inox = 30 mm), swimming pool Visual check v Before operating the pump, first make a visual check, if there
water (prerequisite is the recommended dosage of additives) and is any damage of the pump (esp. regarding power cable and
w
10 11
G G
Connecting the hose : The universal fitting 7 allows you to connect all the hoses listed
Notes on use v Clear the outlet line before use. in the previous table.
Dry-running operation causes increased wear and is to be 1. Cut off nipples of the universal fitting 7, which are not needed,
avoided. Therefore, in continuous operation the pump must be to match the hose connection.
immediately unplugged when water fails to flow. 2. Screw the universal fitting 7 onto the pump.
Avoid running of the pump for more than 10 min. against closed 3. Connect the hose to the universal fitting 7.
delivery side of the pump.
We recommend that you secure 32 mm (5 /4”) and 25 mm (1”)
Sand and other abrasive substances cause increased wear and hoses additionally with a GARDENA Hose Clip Art. No. 1591.
reduce the pump’s output.
Take care that the pump is located where the inlet openings at Only for 13 mm (1/ 2”) hose :
the suction base are obstructed neither completely nor partly. The universal fitting 7 can also be equipped with a GARDENA
Stand the pump on a brick if using in a pond.
7 Regulator Valve Art. No. 977 so that the contents of the out-
let line do not flow back through the pump after pumping.
Thermal motor protector The pump is automatically switched off on overheating by The Regulator Valve can be ordered from GARDENA Service.
the built-in thermal motor protector. After having cooled down,
eu
the motor automatically switches on again (see 6. Trouble
Shooting).
4. Operation
s.
Automatic deaerating The automatic deaerating valve eliminates any air pockets in To ensure that the pump draws the water out, the water to be
valve the pump. During this process, air escapes through the vent drained must be at least 10 cm deep.
al
bore and air bubbles appear underwater. This is not a defect of
Automatic operation : The float switch 5 turns the pump on automatically when the
your pump, but serves to deaerate the pump.
water level exceeds the cut-in height and the water is pumped out.
u
2 The float switch 5 turns the pump off again as soon as the water
an
level falls below the cut-out height.
3
3. Initial Operation 1. Stand the pump on a firm surface
7 – or –
em
13 mm (1/ 2 ”) use a rope attached through the bore hole in the carrying
Hose diameter 16 mm (5 / 8”) 25 mm (1”) 32 mm (5 /4”)
5 handle 2 to immerse the pump in a well or shaft.
19 mm (3 /4”) During automatic operation, ensure that the float switch 5
can move freely.
ic
6 1 2. Plug the power cable 1 into a mains socket.
ev
a Adjusting the Cut-in and Cut-out Height :
The maximum cut-in height and minimum cut-out height (see
b 8. Technical Data) can be adjusted.
.d
7 v Push the cable of the float switch 5 into the float switch lock 3.
The shorter the length of cable between the float switch 5
w
and the float switch lock 3, the lower the cut-in height and the
Hose connection higher the cut-out height.
w
of universal fitting 7
Continuous operation : The pump remains in constant operation because the float switch
w
Hose connection Cut off topmost Do not cut off Cut off top two is bypassed.
nipple at a. any nipples. nipples at b. 1. Stand the pump on a firm surface
Use GARDENA pump connection set art. no. 1750 (for 13 mm / 5 – or –
16 mm) or art.-no. 1752 (for 19 mm) for hose diameters from use a rope attached through the bore hole in the carrying
13 mm to 19 mm. 2 handle 2 to immerse the pump in a well or shaft.
Best results in delivery capacity are achieved when using 32 mm 2. Plug the power cable 1 into a mains socket.
(5 /4”) hoses. 3. Fix float switch 5 vertically above the pump (with the cable
at the bottom).
As long as the float switch is positioned vertically above the
pump, the pump will operate regardless of the water level.
The residual water height (9000 S Inox = 5 mm / 15000 S / SP
Inox = 30 mm) is only reached during continuous operation
since the float switch turns off the pump during automatic opera-
1 tion before this water level is reached.
12 13
G G
5. Cleaning Attention ! Repairs on electrical parts should only be done by our
GARDENA Service Centres.
The pumps are virtually maintenance-free.
If you have any problems with your Pump, please contact our Service.
Flushing the Pump : After having pumped chlorinated swimming pool water or other
liquids leaving residues, the pump should be rinsed with clear
water.
7. Storage
Cleaning the suction Warning ! Electric shock !
base and turbine : A Risk of injury due to electric shock.
Frost-free storage Store the pump away from frost before the first frost sets in.
V Disconnect the pump from the mains before clean-
9 6 8 ing the suction base and turbine.
eu
2. Clean the suction base 6 and the turbine 9.
3. Reinstall the suction base 6 and screw in the Phillips screws 8. Type Submersible Pump Dirty-Water Pump
9000 S Inox 15000 S / SP Inox
s.
For safety reasons a damaged turbine 9 can only be ex- (Art. No. 1452) (Art. No. 1459)
changed by the GARDENA Service Centre. Rated power 400 W 800 W
al
Max. delivery capacity 9,000 l / h 15,000 l / h
6. Trouble-Shooting
u
Max. pressure 0.7 bar 0.9 bar
Max. delivery height 7m 9m
an
Problem Probable cause Remedy
Max. submersion depth 9m 9m
Pump is running, Air cannot escape, since v Open pressure line Residual water height 5 mm 30 mm
em
but doesn’t deliver. pressure line is closed. (e.g. kinked pressure pipe).
Contaminated water with
Air locks in the suction base. v Wait for max. 60 seconds particle size of max. 5 mm 30 mm
until the pump deaerates
Power cable 10 m H05 RNF 10 m H07 RNF
ic
automatically over the vent
valve. If necessary, switch Pump connection 32 mm (5 /4”) / 25 mm (1”) graduated nipple,
ev
off and start it again. option GARDENA Water hose Plug-in-system
Turbine clogged. v Disconnect plug and clean Min. water level for operation 7 cm 10 cm
turbine (see 5. Cleaning).
.d
Weight approx. 4 kg 6 kg
When starting the pump, v Submerge pump deeper.
Max. media temperature 35 °C 35 °C
water height falls below the
w
min. water level. Mains voltage /
mains frequency 230 V / 50 Hz 230 V / 50 Hz
w
Pump doesn’t start or Thermal overload switch has v Disconnect plug and clean
suddenly stops during switched the pump off due turbine (see 5. Cleaning). Cut-in height 55 cm 60 cm
w
14 15
G
Performance characteristics
G
m bar EU Certificate of Conformity
10 1.0
The undersigned
GARDENA Kress + Kastner GmbH · Hans-Lorenser-Str. 40 · D-89079 Ulm
8 0.8
hereby certifies that, when leaving our factory, the units indicated below are in accordance with the
150 harmonised EU guidelines, EU standards of safety and product specific standards.
6 00 0.6
S / SP This certificate becomes void if the units are modified without our approval.
Ino
4 x 0.4
90 Description of the units : Submersible Pump / Dirty-Water Pump
00
S Types : 9000 S Inox / 15000 S / SP Inox
2 Ino 0.2
x Art. No. : 1452 / 1459
0
EU directives : Machinery Directive 98 / 37/ EC
0 5000 10000 15000 Electromagnetic Compatibility 89 / 336 / EC
l/h Low Voltage Directive 73 / 23 / EC
eu
Directive 93 / 68 / EC
Harmonised
9. Service European standards : EN 292 -1 Ulm, 01.06.1999
s.
EN 292 - 2
Warranty GARDENA honours the guarantee legally required for this pro- EN 60335 -1
al
duct (starting from the date of purchase). This guarantee covers EN 60335 - 2 - 41
all serious defects of the unit that can be proved to be material
Year of CE marking : 1999 Thomas Heinl
u
or manufacturing faults. Under warranty we will either replace the
Technical Dept. Manager
unit or repair it free of charge if the following conditions apply:
an
• The unit must have been handled properly and in keeping with
the requirements of the operating instructions.
• Neither the purchaser or a non-authorised third party have
em
attempted to repair the unit.
• The turbine is a wearing part and is not covered by the guar-
antee.
ic
This manufacturer’s guarantee does not affect the user’s existing
warranty claims against the dealer / seller.
ev
If you have any problems with your pump, please contact our
Customer Service or return the defective unit together with
.d
a short description of the problem directly to one of the
GARDENA Service Centres listed on the back of this leaflet.
w
Product Liability We expressly point out that, in accordance with the product
liability law, we are not liable for any damage caused by our units
w
16 17
Deutschland Finland Norway
GARDENA Kress + Kastner GmbH Habitec Oy GARDENA Norge A / S
GARDENA Service Martinkyläntie 52 Postboks 214
Hans-Lorenser-Straße 40 01720 Vantaa 2013 Skjetten
D-89079 Ulm France Poland
Produktfragen: (07 31) 490 - 123 GARDENA France GARDENA Polska Sp. z o.o.
Reparaturen: (07 31) 490 - 290 Service Après-Vente Szymanów 9 d
Argentina BP 50080 05 - 532 Baniocha
Argensem S.A. 95948 ROISSY CDG Cedex Portugal
Venezuela 1075 Great Britain MARKT (Portugal), Lda.
(1618) El Talar - Buenos Aires GARDENA UK Ltd. Recta da Granja do Marquês
Australia 27- 28 Brenkley Way Edif. GARDENA
NYLEX Corporation Ltd. Blezard Business Park Algueirão
25 - 29 Nepean Highway Seaton Burn 2725-596 Mem Martins
P.O. Box 68 Newcastle upon Tyne Russia / Россия
Mentone, Victoria 3194 NE13 6DS АО АМИДА ТТЦ
eu
Austria Greece ул. Моcфилмовcкая 66
GARDENA Österreich Ges. m.b.H. Agrokip G. Psomadopoulos & Co. 117330 Моcква
Stettnerweg 11-15 20, Lykourgou str. Singapore
2100 Korneuburg Kallithea - Athens Variware
s.
Belgium Hungary Holland Road Shopping Centre
MARKT (Belgium) NV/ SA GARDENA Magyarország Kft. 227-A 1st Fl., Unit 29
al
Sterrebeekstraat 163 Késmárk utca 22 Holland Avenue
1930 Zaventem 1158 Budapest Singapore 1027
u
Brazil Iceland Slowenia / Croatia
M. Cassab Heimilistaeki hf Silk d.o.o. Trgovina
an
Av. das Nações Unidas, 20.882 Saetun 8 Brodišče 15
Santo Amaro, CEP 04795-000 P.O. Box 5340 1236 Trzin
São Paulo - S.P. 125 Reykjavik South Africa
em
Bulgaria / България Republic of Ireland GARDENA South Africa (Pty.) Ltd.
ДЕНЕКС ООД Michael McLoughlin & Sons P.O. Box 11534
бул. „Черни връх“ 43 Hardware Limited Vorna Valley 1686
София 1407 Long Mile Road Spain
ic
Canada Dublin 12 ANMI Andreu y Miriam S.A.
GARDENA Canada Ltd. Italy Calle Pere IV, 111
ev
100, Summerlea Road GARDENA Italia S.r.l. 08018 Barcelona
Brampton, Ontario Via Donizetti 22 Sweden
Canada L6T 4X3 20020 Lainate (Mi) GARDENA Svenska AB
.d
Chile Japan Box 9003
Antonio Martinic Y CIA. LTDA. KAKUDAI Mfg. Co. Ltd. 20039 Malmö
Gilberto Fuenzalida 185 Loc. 1- 4 - 4, Itachibori Nishi-ku Switzerland
w
Las Condes - Santiago de Chile Osaka 550 GARDENA Kress + Kastner AG
Costa Rica Luxembourg Bitziberg 1
w