6 Nov. 2022 22:58:47 - trabajo smyah studio.

sm

AREA OF STRUCTURAL STEEL SECTIONS

SURNAMES AND NAMES: PAITAN GIRALDEZ, JHON SMITH

9) design the section of a rectangular beam, to do so consider a minimum width of 25cm, then calculate the
area of ??steel needed under service load conditions, with an acting bending force of 2.4ton-m, also indicate
the type of failure and the stresses that occur in concrete and steel. Check if the internal tensile and
compressive forces are in balance.
For the calculation of "n", consider Es= 2.1*10^6

DATA

kgf kgf
f`C 175 fy 4200
2 2
cm cm
411879300 f`c kg
f`c fy
2
ms
kgf
fc.max 0.45 f`C 78.75
2 kgf
cm fs.max 0.50 fy 2100
2
cm

Mac 2.4 tonnef m

Solution
calculation of resistant moment mr
1) Calculation of k in a balanced fault

1 kgf kgf
k fs fs.max 2100 fc fc.max 78.75
fs 2 2
1 cm cm
n fc

6 kgf
Es 2.1 10
2 f`C
cm kgf 5 kgf
Ec 15000 1.9843 10
kgf 2 2
cm cm
2
cm

Es we assume n round n , 0 11 n homogenizes the type of material


n 10.583
Ec

1
k 0.292
fs k 0.292
1
n fc

1/3
6 Nov. 2022 22:58:47 - trabajo smyah studio.sm

2) calculation of the sections of the rectangular beam

k 0.292 k
j 1 0.903
3

bmin 25 cm (according to regulations it is also a fact to consider)

b bmin
2 from formula the unknown d is cleared
fc k j b d
M
2

2 Mac
d 30.412 cm h d 6 cm 36.41 cm
fc k j b

Mac 2
As 4.1632 cm
fs j d

3) understanding of concrete (C)

fc k d b
C 8742.64 kgf
2

4) tensile steel (T)

T As fs 8742.64 kgf

we adapt

h 35 cm

b bmin 25 cm

2
As 4.16 cm use 1Ø5/8" + 2Ø1/2"

5
in
8
d h 4 cm 0.95 cm 29.26 cm
2

2/3
6 Nov. 2022 22:58:47 - trabajo smyah studio.sm

grafica

caracteristicas de las barras corrugadas

3/3