You are on page 1of 1

LEGEND

LEGENDS 1. THIS DRAWING IS THE PROPERTY AND COPYRIGHT AND


COPYRIGHTOF M/S DESIGN PLUS AND SHALL NOT BE COPIED
OR USED IN ANY WAY WITHOUT THEIR WRITTEN
PERMISSION.

2. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH


THE OTHER RELEVANT ARCHITECTURAL AND OTHER
CONSULTANTS DRAWINGS. IT SHALL BE DEEMED THE
RESPONSIBIAPTY OF THE CONTRACTOR OR THE
FABRICATOR TO BRING TO THE NOTICE OF THE
K OUT ARCHITECTS, PRIOR TO STARTING ANY CONSTRUCTION
-03 BREA
ST-A OR FABRICATION, ANY DISCREPANCY WITHIN OR
BETWEEN THE ABOVE MENTIONED DRAWINGS.
3. ALL DIMENSIONS ARE IN MM AND TO BE READ ONLY AND
NOT MEASURED.

VP
CORR
IDOR 4. ANY DISCRIPANCY IN THE CROSS CHECK DIMENSIONS
WIDE
1.8 M ARE TO BE BROUGHT IN THE NOTICE OF THE ARCHITECTS
BY THE CONTRACTOR/PROJECT MANAGERS IMMEDIATELY.

AVP
5. PROJECT MANAGERS / CONTRACTORS TO VERIFY ALL SITE
CONDITIONS AND ANY CONDITION DIFFERENT OR NOT IN
COHERRENCE WITH THE DRAWINGS / DETAILS MUST BE
IMMEDIATELY INFORMED TO THE ARCHITECTS.
)
TOI(L

R
6. ALL DRAWINGS.DETAILS TO BE REFERED IN

CORRIDO
CONJUNCTION TO THE CORRESPONDING ITEMS OF BILL
OF QUANTITIES. ANY DISCRIPANCY TO BE INFORMED TO
ARCHITECTS.

Key Plan

GUARD

OR
TABLE

RRID
. RM. R. NO. DESCRIPTION ISSUE DATE
ELEC

O
ST-A-01

E C
WID
F.T.

RM.

M
AHU

2.8
AVP
M.
HUB R

S
AT
4 SE
32
1- WIDE
CORRIDOR

C 3.3 M

OD

DOR GUARD

R RI TABLE

E CO
ID
M
W
S
MEETING ROOM T-A-09
.9 AT 4 PAX
1 1 SE
-12
C2
OD MEETING ROOM

1.
4 PAX

9
M
RM.

W
AHU

ID
MEETING ROOM

E
4 PAX

CO
R
RI
DOR
A -04
ST-
FR
01
-A-
ST
FR

MEETING ROOM
4 PAX
.
RM

TS
U
AH

MEETING ROOM
1. A
SE
T.

4 PAX
F.

8 9
M -9
W 3
)

ID
I(L

C
TO

A.
E
CO OD MEETING ROOM
4 PAX
C. AV -03
AM

SH
RR
LO OU 0
W T
BE UT X20

P -A
BE

AF
ST
C 00

T
T ING

FR
ID
4

AF B
SH LUM

O
P

R
)
I(G
TO

E
G
UN

ION
ANS
LO

K . EXP T.
H DE
25 T T AS/
.
RM
T.

N
JOI
F.

B
HU

sink

MICROWAVE
TEA/COFFEE
MACHINE

WATER
DISPENSER
NY

WATER
DISPENSER
O
LC

ARCHITECTS
BA

DESIGNPLUS ASSOCIATES SERVICES


PRIVATE LIMITED
(Designplus Architecture Pvt. Ltd.)
7TH Floor, Tower , DLF Cyber Greens,
.
M
.R

DLF Cyer City, Gurugram,


T.

EC
F.

EL

.
RM
U

Phone : +91-122-4684300
AH

website : www.dpa.co.in
ARCHITECTS
A.
PHE CONSULTANT
R
O

C.
S

ID

SH
NK

RR

AF
CO
TA

T
T.
ER

F.
AT
W

2
-0
-A
ST
FR

PROJECT TITLE:
PROPOSED INTERIOR FOR
GENPACT,
HYDERABAD, INDIA
DRAWING TITLE:
GROUND FLOOR PLAN
FIRE FIGHTING LAYOUT

DEALT BY: PULKIT APPROVED BY:


CHKD BY: FAIZAN
SCALE : AS/SPECIFY DATE : 21.10.2020
SIGN: NORTH
FOR TENDER
FOR INFORMATION
FOR EXECUTION
FOR GFC
E
REVISION:
DRAWING NO:
FF-01 R0