You are on page 1of 16

471

407

Validate Print Help Percentage BoQ


Tender Inviting Authority:

Name of Work: E- Tender for "Conducting NDT, Load Testing, preparation of Traffic diversion plan, Rate Analysis, Cost Estimate, BOQ, Interpretation of Test Results, Correlation of Theoretical and Field
Results, Rehabilitation Measures, Report Preparation Etc. for Bridges/Flyovers (Two Packages) Under Hoogly River Bridge Commissioners (HRBC)- Kolkata , Govt. of West Bengal" - (Package - 2 : BOQ for
Structural Health Assessment Project of 3 Nos. Bridges /Flyovers at Kolkata - Flyovers/Bridges under Package-2: (i) Nagerbazar flyover, (ii) Cossipore & Lockgate flyover) & (iii) Kidderpore new flyover).

Contract No: Open e-Tender No. RITES/IS/RCED/HRBC-KOL – 6 Flyovers/2020, Dated 26.05.2020


Name of the STRUCT GEOTECH RESEARCH LABORATORIES PRIVATE LIMITED
Bidder/
Bidding Firm /
Company :
PRICE SCHEDULE Package-2
(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to
enter the Bidder Name and Values only )
Note:- 1-Annexur-B of Tender Document shall also be reffered prior to Quote the Rates.
2- Rates shall be quoated excluding GST. GST Rate/Amount shall not be considered for evaluation of financial Bid.
3-GST shall be paid over and above the quoted price at the current applicable rate i.e. 18%.

NUMBER # TEXT # NUMBER # TEXT # NUMBER NUMBER # TEXT #

Estimated Rate TOTAL AMOUNT


Sl. TOTAL AMOUNT
Item Description Quantity Units in in
No. In Words
Rs. Rs.

1 2 4 5 6 7 8
Updation of NDT marking plan as provided by RITES, by visual inspection
through a bridge expert and videographer, using its own means to cover
areas of high distress & abnormal variations in structure prior to start of NDT
1 activity. Submission of detailed investigation plan along with updated NDT 3 No. of flyovers 25000.00 75000.00 INR Seventy Five Thousand Only
marking plan within 10 days from the date of initiation of work for approval of
RITES. Mapping over the structural members at the site with good quality
paint (for visibility at day & night) with indication of width, length and depth.
2 NDT FOR RCC STRUCTURES
2.01 Rebound Hammer Test: For determining the estimated compressive
strength of concrete and uniformity of concrete in terms of surface hardness
INR Fifty Seven Thousand Seven Hundred & Fifty
as per IS 13311 (Part-2)-1992, also establishing correlation chart between 330 Nos 175.00 57750.00
Only
rebound hammer and other confirmatory test for estimated in-situ strength of
concrete if required.
i d
2.02 Ultrasonic Pulse Velocity Test: for ascertaining the quality of concrete,
INR One Lakh Twenty Five Thousand Four Hundred
soundness and density of concrete, uniformity of concrete in terms of density 330 Nos 380.00 125400.00
Only
as per IS 13311 (Part-1)-1992.
2.03 CORE Sampling and Testing (Partially Destructive Test): Extracting the
concrete core samples at select locations from RCC members of the
structures covered under the study and evaluating the properties fck value,
grade of concrete in the laboratory from the core samples selected. IS
456:2000; IS516:1959, IS 1199:2002; without encountering any steel
18 Nos. of Set 12000.00 216000.00 INR Two Lakh Sixteen Thousand Only
reinforcement from the RCC members at specified locations by site in-
charge with portable power driven core cutting equipment. After extraction of
core from the structures, each core extraction/cutting location shall be filled
with epoxy materials asper standard practice and codal guide lines.
(1 Set = 3 Nos. of Core)
2.04 Carbonation Test: Measurement of carbonation depth by phenolphthalein
spray test at selected locations on RCC members of the structures covered
under the study to see the depth of carbonation as per BS EN 14630:2006, 142 Nos 1500.00 213000.00 INR Two Lakh Thirteen Thousand Only
BS EN 13295:2004. Ratio of Carbonation depth to cover depth is also
measured to check the intensity of carbonation attack on steel bar
472
407

2.05 Determination of pH, Chloride & Sulphate Content : Water Soluble


Chloride & Sulphate Content % (by mass of concrete) to check the risk of
corrosion due to present chloride % as per IS: 14959 (Part 2) – 2001, B.S.
70 Nos 2000.00 140000.00 INR One Lakh Forty Thousand Only
5328 Part 1, ACI 201.2R-92, BS 1881 Part 124:1988, BS 8110, IS 456:2000
and other relevant Codes. pH Value (to check alkanity of concrete) as per
relevant B.S. 5328, ACI 201.2R-92 and ACI-318-99, IS 456:2000, BS 8110.
2.06 Cover Depth Test :RCC details by using ferro-scanner for measuring the
cover depth by using cover meter and existing protecting layer of steel rebar,
54 Nos 1200.00 64800.00 INR Sixty Four Thousand Eight Hundred Only
diameter of steel and number of rebar, Preparation of structural details of
RCC sections.
2.07 Half Cell Potential Test :Measuring the Half Cell Potential readings with
electrode at the nodes of pre-marked grid points on concrete surface in a
suitable grid for determining the probability of corrosion activity of embedded
steel reinforcement in concrete with specified half cell electrode in
accordance with ASTM C876-1980 after moistening the concrete surface
with water. The rate shall include surface preparation, moistening concrete
INR Forty Three Thousand Seven Hundred & Fifty
surface for assessing the percentage risk of corrosion in reinforcement, 35 Nos 1250.00 43750.00
Only
Measuring the half-cell / surface potentials at selected locations on RCC
members of the structures covered under the study to understand the extent
of reinforcement corrosion and contour Mapping of corrosion, Plotting the
half cell potential readings in graphical presentation with potential contours
plotted in terms of probable risk of corrosion of steel bar as per ASTM C876
[6]-1991.
2.08 Resistivity Meter Test : It is used in determination of Estimation of the
likelihood of corrosion, Indication of corrosion rate, Correlation to chloride
permeability, Determination of zonal requirements for cathodic protection
35 Nos 2500.00 87500.00 INR Eighty Seven Thousand Five Hundred Only
systems, Identification of areas within a structure most susceptible to
chloride penetration as per BS EN 12696:2000, RILEM TC-154, AASHTO
T277 RCP, AASHTO T259, ASTM C 1202 971
2.09 RCC Mapping by GPR/Section Profiling : Mapping of reinforcement in
RCC members by using x-ray/magnetic based scanner at doubtful location in
the grid size of 600x600mm; each picture shot and plotting of the same
details on drawings measuring the cover depth and existing protecting layer 70 Nos 2500.00 175000.00 INR One Lakh Seventy Five Thousand Only
of steel rebar, diameter of steel and number of rebar, Preparation of
structural details of RCC sections spacing of bar up to 300mm -450 mm
depth, Very high frequency Hz GPR
3 NDT FOR STEEL STRUCTURES

3.01 Liquid Penetration Testing : To reveal surface breaking flaws by bleed out
off a colored
l d or fluorescent
fl t dye
d from
f the
th flaw
fl as per ASME standards
t d d refers
f
400 Nos 500.00 200000.00 INR Two Lakh Only
to the ASME Code Section V Article 6 and ASME VIII Div 1 Appendix 8 and
other relevant sections/guidelines.
3.02 Ultrasonic Pulse Eco Testing of Metallic Sections:- For assessment of

welding/joints assessment of Steel Plates/Tube/Pipe Weld/Forging/Casting 400 Nos 1000.00 400000.00 INR Four Lakh Only

as per ASTM A-435/A435M-82 ASME Sec V, range (0mm-5000mm).


3.03 Dry Film Thickness:- Dry film / Coating thickness of external surface
materials (paint, anti-corrosive coating etc..) on Ferrous and Non-ferrous 190 Nos 250.00 47500.00 INR Forty Seven Thousand Five Hundred Only
Metals/Alloys as per IS: 3023 Up to 1000 micron.
3.04 Magnetic Particle Testing Ferrous Metals as per ASTM-709, 1995; ASME
Sec-5, 200; ASTM A275 range(Up to 3mm depth) to assess the 440 Nos 500.00 220000.00 INR Two Lakh Twenty Thousand Only
cracks/joints/welding conditions rang
3.05 UT Thickness for Steel Section Size Assessment:- Local thickness of a
solid/hollow element based on the time taken by the ultrasound wave to
190 Nos 500.00 95000.00 INR Ninety Five Thousand Only
return to the surface as per ASTM E797 / E797M for section detailing of steel
members.
473
407

3.06 Hardness Testing of metals: Hardness of Ferrous & Non-ferrous

Metals/Alloys Vickers 80-94; HRC 17.9-68.5 HRB 13.5-99.5, LD 200-900, HB 40 Nos 400.00 16000.00 INR Sixteen Thousand Only

82.0-940.0 to get the type of material and its estimated tensile strength.
3.07 Inspecting torque/Tension on Nut/ Bolt: To determine the torque to a
fasten nut or bolt permits proper tension and loading wherever bolts are
loose and found deteriorated. Check torque applied to the nut/bolt so it can
be matched to the specifications as per codal requirement IS 6623: 2004.
Also check the gap between bolt/nut using filler gauge. When nuts and bolts 10 Nos 8000.00 80000.00 INR Eighty Thousand Only
are fastened together under load the action of tightening the nut increases
the force applied to the bolt causing elongation. Bolt tension monitors should
be also used to accurately measure the elongation, stress, and %strain of the
bolt during traffic load in 5% intact bolts.
3.08 Mechanical Testing of Loosened Bolt : To evaluate the mechanical
properties like Tensile Strength and Shear Strength of the bolt and to 12 Nos 4000.00 48000.00 INR Forty Eight Thousand Only
evaluate the grade of bolt.
3.09 Radiography test for weld/lamination, as per field requirement. Test should
be conducted the conducted under the supervision of approved radioactive 9 Nos 10000.00 90000.00 INR Ninety Thousand Only
system operator (license holder from Govt.).

4 Load Testing and Miscellaneous

4.01 Geotechnical Survey: Carrying out Geotechnical soil investigation work by


tools & plants as per Indian codal provisions and site requirement. Drilling of
150mm dia Bore Hole (BH) in approaches of flyovers for a depth o approx.
15m or refusal strata whichever is earlier, including providing and supplying
4 Nos of BH 150000.00 600000.00 INR Six Lakh Only
of wooden core boxes for samples, logging of all bore holes and also
includes preparation of reports, conducting of various field and lab tests as
per scope of work, complete all as per specifications/latest relavent IS codes
and as per instructions of Engineer in Charge.
4.02 Static Load Testing of the bridges/flyover for all Flyovers : Conducting
load testing on already constructed deck slabs and assessment of its load
carrying capacity as per latest guidelines of IRC and other relevant
standards. The rating of the structure shall be assessed both using
8 Nos 600000.00 4800000.00 INR Forty Eight Lakh Only
Analytical Method & through Load Testing. A comparative chart to be plotted
between observed v/s theoretical strain and deflection against the sequence
loading up to full proof loading. Traffic Diversion Plan and Contingency plan
shall also be prepared.
474
407

4.03 Dynamic load test on the flyover/bridge spans: Evaluate the dynamic
behavior of bridge with calculation of various parameter like strain, vertical
deflection, vibration and lateral movement near the expansion joints through
correlation with the identified peaks and traffic loads and full load test. 3 Nos 200000.00 600000.00 INR Six Lakh Only
Sensors to be installed 3-Axis Accelerometer (Vibration due to Traffic
movement & Displacement), Strain Gauge (Strain value) & LVDT Sensor
(Displacement/crack movement).
4.04 Condition Assessment of the each and every Bearings & expansion
joint of flyover: Each and every bearing identification along with
3 No. of flyovers 100000.00 300000.00 INR Three Lakh Only
photograph of their present condition, suggestion for replacement or
maintenance if required immediate marked over the drawing.
5 PREPARATION & SUBMISSION OF DPR

5.01 Specialized consulting firm /Agency shall prepare and submit the DPR of
each flyovers/bridge in 3 copies which includes all inspection and NDT
results, interpretation of test results, load test reports, conclusion, site
photographs, scheme for repair/rehabilitation/ retro-fitting works with BOQ
and Rate analysis, technical Specifications, design and execution drawing
3 No. of flyovers 150000.00 450000.00 INR Four Lakh Fifty Thousand Only
(feasible and economic options) for rehabilitation/strengthening of flyovers,
improvement of drainage system, traffic diversion plan, bridge inspection
and maintenance manual including QAP, safety and environmental plan. HD
quality site photographs and Video during inspection & testing shall be
provided in a good quality CD/DVD/USB hard disk..

INR Ninety One Lakh Forty Four Thousand Seven


Total in Figures 9144700.00 Hundred Only

INR Seventy Seven Lakh Seventy Two Thousand Nine


Quoted Rate in Figures Less (-) 15.00% 7772995.00 Hundred & Ninety Five Only

Quoted Rate in Words INR Seventy Seven Lakh Seventy Two Thousand Nine Hundred & Ninety Five Only
2194
508

Validate Print Help Percentage BoQ


Tender Inviting Authority:

Name of Work: E- Tender for "Conducting NDT, Load Testing, preparation of Traffic diversion plan, Rate Analysis, Cost Estimate, BOQ, Interpretation of Test Results, Correlation of Theoretical and Field
Results, Rehabilitation Measures, Report Preparation Etc. for 3 Flyovers/Bridges Under Hoogly River Bridge Commissioners (HRBC)- Kolkata , Govt. of West Bengal" - BOQ for Structural Health Assessment
Project of 3 Nos. Flyovers/Bridges at Kolkata - (i) Nagerbazar flyover, (ii) Cossipore & Lockgate flyover) & (iii) Kidderpore new flyover).

Contract No: RITES/IS/RCED/HRBC-KOL – 3 Flyovers/2020, Dated 17.08.2020

Name of the Cortex Construction Solutions Pvt Ltd


Bidder/
Bidding Firm /
Company :

PRICE SCHEDULE
(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to
enter the Bidder Name and Values only )
Note:- 1-Annexur-B of Tender Document shall also be reffered prior to Quote the Rates.
2- Rates shall be quoated excluding GST. GST Rate/Amount shall not be considered for evaluation of financial Bid.
3-GST shall be paid over and above the quoted price at the current applicable rate i.e. 18%.

NUMBER # TEXT # NUMBER # TEXT # NUMBER NUMBER # TEXT #

Estimated Rate TOTAL AMOUNT


Sl. TOTAL AMOUNT
Item Description Quantity Units in in
No. In Words
Rs. Rs.

1 2 4 5 6 7 8
Updation of NDT marking plan as provided by RITES, by visual inspection
through a bridge expert and videographer, using its own means to cover
areas of high distress & abnormal variations in structure prior to start of NDT
1 activity. Submission of detailed investigation plan along with updated NDT 3 No. of flyovers 25000.00 75000.00 INR Seventy Five Thousand Only
marking plan within 10 days from the date of initiation of work for approval of
RITES. Mapping over the structural members at the site with good quality
paint (for visibility at day & night) with indication of width, length and depth.
2 NDT FOR RCC STRUCTURES

2.01 Rebound Hammer Test: For determining the estimated compressive


strength of concrete and uniformity of concrete in terms of surface hardness
INR Fifty Seven Thousand Seven Hundred & Fifty
as per IS 13311 (Part-2)-1992, also establishing correlation chart between 330 Nos 175.00 57750.00
Only
rebound hammer and other confirmatory test for estimated in-situ strength of
concrete if required.
2.02 Ultrasonic Pulse Velocity Test: for ascertaining the quality of concrete,
INR One Lakh Twenty Five Thousand Four Hundred
soundness and density of concrete, uniformity of concrete in terms of density 330 Nos 380.00 125400.00
Only
as per IS 13311 (Part-1)-1992.
2.03 CORE Sampling and Testing (Partially Destructive Test): Extracting the
concrete core samples at select locations from RCC members of the
structures covered under the study and evaluating the properties fck value,
grade of concrete in the laboratory from the core samples selected. IS
456:2000; IS516:1959, IS 1199:2002; without encountering any steel
18 Nos. of Set 12000.00 216000.00 INR Two Lakh Sixteen Thousand Only
reinforcement from the RCC members at specified locations by site in-charge
with portable power driven core cutting equipment. After extraction of core
from the structures, each core extraction/cutting location shall be filled with
epoxy materials asper standard practice and codal guide lines.
(1 Set = 3 Nos. of Core)
2195
508

2.04 Carbonation Test: Measurement of carbonation depth by phenolphthalein


spray test at selected locations on RCC members of the structures covered
under the study to see the depth of carbonation as per BS EN 14630:2006, 142 Nos 1500.00 213000.00 INR Two Lakh Thirteen Thousand Only
BS EN 13295:2004. Ratio of Carbonation depth to cover depth is also
measured to check the intensity of carbonation attack on steel bar
2.05 Determination of pH, Chloride & Sulphate Content : Water Soluble
Chloride & Sulphate Content % (by mass of concrete) to check the risk of
corrosion due to present chloride % as per IS: 14959 (Part 2) – 2001, B.S.
70 Nos 2000.00 140000.00 INR One Lakh Forty Thousand Only
5328 Part 1, ACI 201.2R-92, BS 1881 Part 124:1988, BS 8110, IS 456:2000
and other relevant Codes. pH Value (to check alkanity of concrete) as per
relevant B.S. 5328, ACI 201.2R-92 and ACI-318-99, IS 456:2000, BS 8110.
2.06 Cover Depth Test :RCC details by using ferro-scanner for measuring the
cover depth by using cover meter and existing protecting layer of steel rebar,
54 Nos 1200.00 64800.00 INR Sixty Four Thousand Eight Hundred Only
diameter of steel and number of rebar, Preparation of structural details of
RCC sections.
2.07 Half Cell Potential Test :Measuring the Half Cell Potential readings with
electrode at the nodes of pre-marked grid points on concrete surface in a
suitable grid for determining the probability of corrosion activity of embedded
steel reinforcement in concrete with specified half cell electrode in
accordance with ASTM C876-1980 after moistening the concrete surface
with water. The rate shall include surface preparation, moistening concrete
INR Forty Three Thousand Seven Hundred & Fifty
surface for assessing the percentage risk of corrosion in reinforcement, 35 Nos 1250.00 43750.00
Only
Measuring the half-cell / surface potentials at selected locations on RCC
members of the structures covered under the study to understand the extent
of reinforcement corrosion and contour Mapping of corrosion, Plotting the
half cell potential readings in graphical presentation with potential contours
plotted in terms of probable risk of corrosion of steel bar as per ASTM C876
[6]-1991.
2.08 Resistivity Meter Test : It is used in determination of Estimation of the
likelihood of corrosion, Indication of corrosion rate, Correlation to chloride
permeability, Determination of zonal requirements for cathodic protection
35 Nos 2500.00 87500.00 INR Eighty Seven Thousand Five Hundred Only
systems, Identification of areas within a structure most susceptible to chloride
penetration as per BS EN 12696:2000, RILEM TC-154, AASHTO T277 RCP,
AASHTO T259, ASTM C 1202 971
2.09 RCC Mapping by GPR/Section Profiling : Mapping of reinforcement in
RCC members by using x-ray/magnetic based scanner at doubtful location in
the grid size of 600x600mm; each picture shot and plotting of the same
details on drawings measuring the cover depth and existing protecting layer 70 Nos 2500.00 175000.00 INR One Lakh Seventy Five Thousand Only
of steel rebar, diameter of steel and number of rebar, Preparation of
structural details of RCC sections spacing of bar up to 300mm -450 mm
depth, Very high frequency Hz GPR

3 NDT FOR STEEL STRUCTURES

3.01 Liquid Penetration Testing : To reveal surface breaking flaws by bleed out
of a colored or fluorescent dye from the flaw as per ASME standards refers
400 Nos 500.00 200000.00 INR Two Lakh Only
to the ASME Code Section V Article 6 and ASME VIII Div 1 Appendix 8 and
other relevant sections/guidelines.
3.02 Ultrasonic Pulse Eco Testing of Metallic Sections:- For assessment of

welding/joints assessment of Steel Plates/Tube/Pipe Weld/Forging/Casting 400 Nos 1000.00 400000.00 INR Four Lakh Only

as per ASTM A-435/A435M-82 ASME Sec V, range (0mm-5000mm).


3.03 Dry Film Thickness:- Dry film / Coating thickness of external surface
materials (paint, anti-corrosive coating etc..) on Ferrous and Non-ferrous 190 Nos 250.00 47500.00 INR Forty Seven Thousand Five Hundred Only
Metals/Alloys as per IS: 3023 Up to 1000 micron.
2196
508

3.04 Magnetic Particle Testing Ferrous Metals as per ASTM-709, 1995; ASME
Sec-5, 200; ASTM A275 range(Up to 3mm depth) to assess the 440 Nos 500.00 220000.00 INR Two Lakh Twenty Thousand Only
cracks/joints/welding conditions rang
3.05 UT Thickness for Steel Section Size Assessment:- Local thickness of a
solid/hollow element based on the time taken by the ultrasound wave to
190 Nos 500.00 95000.00 INR Ninety Five Thousand Only
return to the surface as per ASTM E797 / E797M for section detailing of steel
members.
3.06 Hardness Testing of metals: Hardness of Ferrous & Non-ferrous

Metals/Alloys Vickers 80-94; HRC 17.9-68.5 HRB 13.5-99.5, LD 200-900, 40 Nos 400.00 16000.00 INR Sixteen Thousand Only

HB 82.0-940.0 to get the type of material and its estimated tensile strength.
3.07 Inspecting torque/Tension on Nut/ Bolt: To determine the torque to a
fasten nut or bolt permits proper tension and loading wherever bolts are
loose and found deteriorated. Check torque applied to the nut/bolt so it can
be matched to the specifications as per codal requirement IS 6623: 2004.
Also check the gap between bolt/nut using filler gauge. When nuts and bolts 10 Nos 8000.00 80000.00 INR Eighty Thousand Only
are fastened together under load the action of tightening the nut increases
the force applied to the bolt causing elongation. Bolt tension monitors should
be also used to accurately measure the elongation, stress, and %strain of
the bolt during traffic load in 5% intact bolts.
3.08 Mechanical Testing of Loosened Bolt : To evaluate the mechanical
properties like Tensile Strength and Shear Strength of the bolt and to 12 Nos 4000.00 48000.00 INR Forty Eight Thousand Only
evaluate the grade of bolt.
3.09 Radiography test for weld/lamination, as per field requirement. Test should
be conducted the conducted under the supervision of approved radioactive 9 Nos 10000.00 90000.00 INR Ninety Thousand Only
system operator (license holder from Govt.).
2197
508

4 Load Testing and Miscellaneous

4.01 Geotechnical Survey: Carrying out Geotechnical soil investigation work by


tools & plants as per Indian codal provisions and site requirement. Drilling of
150mm dia Bore Hole (BH) in approaches of flyovers for a depth o approx.
15m or refusal strata whichever is earlier, including providing and supplying
4 Nos of BH 150000.00 600000.00 INR Six Lakh Only
of wooden core boxes for samples, logging of all bore holes and also
includes preparation of reports, conducting of various field and lab tests as
per scope of work, complete all as per specifications/latest relavent IS codes
and as per instructions of Engineer in Charge.
4.02 Static Load Testing of the bridges/flyover for all Flyovers : Conducting
load testing on already constructed deck slabs and assessment of its load
carrying capacity as per latest guidelines of IRC and other relevant
standards. The rating of the structure shall be assessed both using
8 Nos 600000.00 4800000.00 INR Forty Eight Lakh Only
Analytical Method & through Load Testing. A comparative chart to be plotted
between observed v/s theoretical strain and deflection against the sequence
loading up to full proof loading. Traffic Diversion Plan and Contingency plan
shall also be prepared.
4.03 Dynamic load test on the flyover/bridge spans: Evaluate the dynamic
behavior of bridge with calculation of various parameter like strain, vertical
deflection, vibration and lateral movement near the expansion joints through
correlation with the identified peaks and traffic loads and full load test. 3 Nos 200000.00 600000.00 INR Six Lakh Only
Sensors to be installed 3-Axis Accelerometer (Vibration due to Traffic
movement & Displacement), Strain Gauge (Strain value) & LVDT Sensor
(Displacement/crack movement).
4.04 Condition Assessment of the each and every Bearings & expansion
joint of flyover: Each and every bearing identification along with
3 No. of flyovers 100000.00 300000.00 INR Three Lakh Only
photograph of their present condition, suggestion for replacement or
maintenance if required immediate marked over the drawing.

5 PREPARATION & SUBMISSION OF DPR

5.01 Specialized consulting firm /Agency shall prepare and submit the DPR of
each flyovers/bridge in 3 copies which includes all inspection and NDT
results, interpretation of test results, load test reports, conclusion, site
photographs,
h t h scheme
h for
f repair/rehabilitation/
i / h bilit ti / retro-fitting
t fitti works
k with
ith BOQ
and Rate analysis, technical Specifications, design and execution drawing
3 No. of flyovers 150000.00 450000.00 INR Four Lakh Fifty Thousand Only
(feasible and economic options) for rehabilitation/strengthening of flyovers,
improvement of drainage system, traffic diversion plan, bridge inspection and
maintenance manual including QAP, safety and environmental plan. HD
quality site photographs and Video during inspection & testing shall be
provided in a good quality CD/DVD/USB hard disk..

INR Ninety One Lakh Forty Four Thousand Seven


Total in Figures 9144700.00 Hundred Only

INR Eighty One Lakh Five Thousand Eight Hundred &


Quoted Rate in Figures Less (-) 11.36% 8105862.08 Sixty Two Only

Quoted Rate in Words INR Eighty One Lakh Five Thousand Eight Hundred & Sixty Two Only
2343
508

Validate Print Help Percentage BoQ


Tender Inviting Authority:

Name of Work: E- Tender for "Conducting NDT, Load Testing, preparation of Traffic diversion plan, Rate Analysis, Cost Estimate, BOQ, Interpretation of Test Results, Correlation of Theoretical and Field Results,
Rehabilitation Measures, Report Preparation Etc. for 3 Flyovers/Bridges Under Hoogly River Bridge Commissioners (HRBC)- Kolkata , Govt. of West Bengal" - BOQ for Structural Health Assessment Project of 3
Nos. Flyovers/Bridges at Kolkata - (i) Nagerbazar flyover, (ii) Cossipore & Lockgate flyover) & (iii) Kidderpore new flyover).

Contract No: RITES/IS/RCED/HRBC-KOL – 3 Flyovers/2020, Dated 17.08.2020

Name of the AIMIL LIMITED


Bidder/
Bidding Firm /
Company :

PRICE SCHEDULE
(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter
the Bidder Name and Values only )
Note:- 1-Annexur-B of Tender Document shall also be reffered prior to Quote the Rates.
2- Rates shall be quoated excluding GST. GST Rate/Amount shall not be considered for evaluation of financial Bid.
3-GST shall be paid over and above the quoted price at the current applicable rate i.e. 18%.

NUMBER # TEXT # NUMBER # TEXT # NUMBER NUMBER # TEXT #

Estimated Rate TOTAL AMOUNT


Sl. TOTAL AMOUNT
Item Description Quantity Units in in
No. In Words
Rs. Rs.

1 2 4 5 6 7 8
Updation of NDT marking plan as provided by RITES, by visual inspection
through a bridge expert and videographer, using its own means to cover areas
of high distress & abnormal variations in structure prior to start of NDT activity.
1 Submission of detailed investigation plan along with updated NDT marking plan 3 No. of flyovers 25000.00 75000.00 INR Seventy Five Thousand Only
within 10 days from the date of initiation of work for approval of RITES.
Mapping over the structural members at the site with good quality paint (for
visibility at day & night) with indication of width, length and depth.
2 NDT FOR RCC STRUCTURES

2.01 Rebound Hammer Test: For determining the estimated compressive strength
of concrete and uniformity of concrete in terms of surface hardness as per IS
13311 (Part-2)-1992, also establishing correlation chart between rebound 330 Nos 175.00 57750.00 INR Fifty Seven Thousand Seven Hundred & Fifty Only
hammer and other confirmatory test for estimated in-situ strength of concrete if
required.
2.02 Ultrasonic Pulse Velocity Test: for ascertaining the quality of concrete,
INR One Lakh Twenty Five Thousand Four Hundred
soundness and density of concrete, uniformity of concrete in terms of density 330 Nos 380.00 125400.00
Only
as per IS 13311 (Part-1)-1992.
2.03 CORE Sampling and Testing (Partially Destructive Test): Extracting the
concrete core samples at select locations from RCC members of the
structures covered under the study and evaluating the properties fck value,
grade of concrete in the laboratory from the core samples selected. IS
456:2000; IS516:1959, IS 1199:2002; without encountering any steel
18 Nos. of Set 12000.00 216000.00 INR Two Lakh Sixteen Thousand Only
reinforcement from the RCC members at specified locations by site in-charge
with portable power driven core cutting equipment. After extraction of core
from the structures, each core extraction/cutting location shall be filled with
epoxy materials asper standard practice and codal guide lines.
(1 Set = 3 Nos. of Core)
2344
508

2.04 Carbonation Test: Measurement of carbonation depth by phenolphthalein


spray test at selected locations on RCC members of the structures covered
under the study to see the depth of carbonation as per BS EN 14630:2006, BS 142 Nos 1500.00 213000.00 INR Two Lakh Thirteen Thousand Only
EN 13295:2004. Ratio of Carbonation depth to cover depth is also measured
to check the intensity of carbonation attack on steel bar
2.05 Determination of pH, Chloride & Sulphate Content : Water Soluble
Chloride & Sulphate Content % (by mass of concrete) to check the risk of
corrosion due to present chloride % as per IS: 14959 (Part 2) – 2001, B.S.
70 Nos 2000.00 140000.00 INR One Lakh Forty Thousand Only
5328 Part 1, ACI 201.2R-92, BS 1881 Part 124:1988, BS 8110, IS 456:2000
and other relevant Codes. pH Value (to check alkanity of concrete) as per
relevant B.S. 5328, ACI 201.2R-92 and ACI-318-99, IS 456:2000, BS 8110.
2.06 Cover Depth Test :RCC details by using ferro-scanner for measuring the
cover depth by using cover meter and existing protecting layer of steel rebar,
54 Nos 1200.00 64800.00 INR Sixty Four Thousand Eight Hundred Only
diameter of steel and number of rebar, Preparation of structural details of RCC
sections.
2.07 Half Cell Potential Test :Measuring the Half Cell Potential readings with
electrode at the nodes of pre-marked grid points on concrete surface in a
suitable grid for determining the probability of corrosion activity of embedded
steel reinforcement in concrete with specified half cell electrode in accordance
with ASTM C876-1980 after moistening the concrete surface with water. The
rate shall include surface preparation, moistening concrete surface for
35 Nos 1250.00 43750.00 INR Forty Three Thousand Seven Hundred & Fifty Only
assessing the percentage risk of corrosion in reinforcement, Measuring the
half-cell / surface potentials at selected locations on RCC members of the
structures covered under the study to understand the extent of reinforcement
corrosion and contour Mapping of corrosion, Plotting the half cell potential
readings in graphical presentation with potential contours plotted in terms of
probable risk of corrosion of steel bar as per ASTM C876 [6]-1991.
2.08 Resistivity Meter Test : It is used in determination of Estimation of the
likelihood of corrosion, Indication of corrosion rate, Correlation to chloride
permeability, Determination of zonal requirements for cathodic protection
35 Nos 2500.00 87500.00 INR Eighty Seven Thousand Five Hundred Only
systems, Identification of areas within a structure most susceptible to chloride
penetration as per BS EN 12696:2000,
12696:2000 RILEM TC-154,
TC-154 AASHTO T277 RCP, RCP
AASHTO T259, ASTM C 1202 971
2.09 RCC Mapping by GPR/Section Profiling : Mapping of reinforcement in RCC
members by using x-ray/magnetic based scanner at doubtful location in the
grid size of 600x600mm; each picture shot and plotting of the same details on
drawings measuring the cover depth and existing protecting layer of steel 70 Nos 2500.00 175000.00 INR One Lakh Seventy Five Thousand Only
rebar, diameter of steel and number of rebar, Preparation of structural details
of RCC sections spacing of bar up to 300mm -450 mm depth, Very high
frequency Hz GPR

3 NDT FOR STEEL STRUCTURES

3.01 Liquid Penetration Testing : To reveal surface breaking flaws by bleed out of
a colored or fluorescent dye from the flaw as per ASME standards refers to the
400 Nos 500.00 200000.00 INR Two Lakh Only
ASME Code Section V Article 6 and ASME VIII Div 1 Appendix 8 and other
relevant sections/guidelines.
3.02 Ultrasonic Pulse Eco Testing of Metallic Sections:- For assessment of

welding/joints assessment of Steel Plates/Tube/Pipe Weld/Forging/Casting as 400 Nos 1000.00 400000.00 INR Four Lakh Only

per ASTM A-435/A435M-82 ASME Sec V, range (0mm-5000mm).


2345
508

3.03 Dry Film Thickness:- Dry film / Coating thickness of external surface
materials (paint, anti-corrosive coating etc..) on Ferrous and Non-ferrous 190 Nos 250.00 47500.00 INR Forty Seven Thousand Five Hundred Only
Metals/Alloys as per IS: 3023 Up to 1000 micron.
3.04 Magnetic Particle Testing Ferrous Metals as per ASTM-709, 1995; ASME
Sec-5, 200; ASTM A275 range(Up to 3mm depth) to assess the 440 Nos 500.00 220000.00 INR Two Lakh Twenty Thousand Only
cracks/joints/welding conditions rang
3.05 UT Thickness for Steel Section Size Assessment:- Local thickness of a
solid/hollow element based on the time taken by the ultrasound wave to return
190 Nos 500.00 95000.00 INR Ninety Five Thousand Only
to the surface as per ASTM E797 / E797M for section detailing of steel
members.
3.06 Hardness Testing of metals: Hardness of Ferrous & Non-ferrous

Metals/Alloys Vickers 80-94; HRC 17.9-68.5 HRB 13.5-99.5, LD 200-900, HB 40 Nos 400.00 16000.00 INR Sixteen Thousand Only

82.0-940.0 to get the type of material and its estimated tensile strength.
3.07 Inspecting torque/Tension on Nut/ Bolt: To determine the torque to a fasten
nut or bolt permits proper tension and loading wherever bolts are loose and
found deteriorated. Check torque applied to the nut/bolt so it can be matched
to the specifications as per codal requirement IS 6623: 2004. Also check the
gap between bolt/nut using filler gauge. When nuts and bolts are fastened 10 Nos 8000.00 80000.00 INR Eighty Thousand Only
together under load the action of tightening the nut increases the force applied
to the bolt causing elongation. Bolt tension monitors should be also used to
accurately measure the elongation, stress, and %strain of the bolt during traffic
load in 5% intact bolts.
3.08 Mechanical Testing of Loosened Bolt : To evaluate the mechanical
properties like Tensile Strength and Shear Strength of the bolt and to evaluate 12 Nos 4000.00 48000.00 INR Forty Eight Thousand Only
the grade of bolt.
3.09 Radiography test for weld/lamination, as per field requirement. Test should be
conducted the conducted under the supervision of approved radioactive 9 Nos 10000.00 90000.00 INR Ninety Thousand Only
system operator (license holder from Govt.).
2346
508

4 Load Testing and Miscellaneous

4.01 Geotechnical Survey: Carrying out Geotechnical soil investigation work by


tools & plants as per Indian codal provisions and site requirement. Drilling of
150mm dia Bore Hole (BH) in approaches of flyovers for a depth o approx.
15m or refusal strata whichever is earlier, including providing and supplying of
4 Nos of BH 150000.00 600000.00 INR Six Lakh Only
wooden core boxes for samples, logging of all bore holes and also includes
preparation of reports, conducting of various field and lab tests as per scope
of work, complete all as per specifications/latest relavent IS codes and as per
instructions of Engineer in Charge.
4.02 Static Load Testing of the bridges/flyover for all Flyovers : Conducting
load testing on already constructed deck slabs and assessment of its load
carrying capacity as per latest guidelines of IRC and other relevant standards.
The rating of the structure shall be assessed both using Analytical Method & 8 Nos 600000.00 4800000.00 INR Forty Eight Lakh Only
through Load Testing. A comparative chart to be plotted between observed v/s
theoretical strain and deflection against the sequence loading up to full proof
loading. Traffic Diversion Plan and Contingency plan shall also be prepared.
4.03 Dynamic load test on the flyover/bridge spans: Evaluate the dynamic
behavior of bridge with calculation of various parameter like strain, vertical
deflection, vibration and lateral movement near the expansion joints through
correlation with the identified peaks and traffic loads and full load test. Sensors 3 Nos 200000.00 600000.00 INR Six Lakh Only
to be installed 3-Axis Accelerometer (Vibration due to Traffic movement &
Displacement), Strain Gauge (Strain value) & LVDT Sensor
(Displacement/crack movement).
4.04 Condition Assessment of the each and every Bearings & expansion joint
of flyover: Each and every bearing identification along with photograph of
3 No. of flyovers 100000.00 300000.00 INR Three Lakh Only
their present condition, suggestion for replacement or maintenance if required
immediate marked over the drawing.

5 PREPARATION & SUBMISSION OF DPR

5.01 Specialized consulting firm /Agency shall prepare and submit the DPR of
each flyovers/bridge in 3 copies which includes all inspection and NDT
results, interpretation of test results, load test reports, conclusion, site
p g p , scheme for repair/rehabilitation/
photographs, p g works with BOQ
retro-fitting Q and
Rate analysis, technical Specifications, design and execution drawing (feasible
3 No. of flyovers 150000.00 450000.00 INR Four Lakh Fifty Thousand Only
and economic options) for rehabilitation/strengthening of flyovers,
improvement of drainage system, traffic diversion plan, bridge inspection and
maintenance manual including QAP, safety and environmental plan. HD quality
site photographs and Video during inspection & testing shall be provided in a
good quality CD/DVD/USB hard disk..

INR Ninety One Lakh Forty Four Thousand Seven


Total in Figures 9144700.00 Hundred Only

INR Seventy Lakh Eighty Two Thousand Five Hundred


Quoted Rate in Figures Less (-) 22.55% 7082570.15 & Seventy Only

Quoted Rate in Words INR Seventy Lakh Eighty Two Thousand Five Hundred & Seventy Only
2857
508

Validate Print Help Percentage BoQ


Tender Inviting Authority:

Name of Work: E- Tender for "Conducting NDT, Load Testing, preparation of Traffic diversion plan, Rate Analysis, Cost Estimate, BOQ, Interpretation of Test Results, Correlation of Theoretical and Field
Results, Rehabilitation Measures, Report Preparation Etc. for 3 Flyovers/Bridges Under Hoogly River Bridge Commissioners (HRBC)- Kolkata , Govt. of West Bengal" - BOQ for Structural Health Assessment
Project of 3 Nos. Flyovers/Bridges at Kolkata - (i) Nagerbazar flyover, (ii) Cossipore & Lockgate flyover) & (iii) Kidderpore new flyover).

Contract No: RITES/IS/RCED/HRBC-KOL – 3 Flyovers/2020, Dated 17.08.2020

Name of the Bureau Veritas (India) Private Limited


Bidder/
Bidding Firm /
Company :

PRICE SCHEDULE
(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to
enter the Bidder Name and Values only )
Note:- 1-Annexur-B of Tender Document shall also be reffered prior to Quote the Rates.
2- Rates shall be quoated excluding GST. GST Rate/Amount shall not be considered for evaluation of financial Bid.
3-GST shall be paid over and above the quoted price at the current applicable rate i.e. 18%.

NUMBER # TEXT # NUMBER # TEXT # NUMBER NUMBER # TEXT #

Estimated Rate TOTAL AMOUNT


Sl. TOTAL AMOUNT
Item Description Quantity Units in in
No. In Words
Rs. Rs.

1 2 4 5 6 7 8
Updation of NDT marking plan as provided by RITES, by visual inspection
through a bridge expert and videographer, using its own means to cover
areas of high distress & abnormal variations in structure prior to start of NDT
1 activity. Submission of detailed investigation plan along with updated NDT 3 No. of flyovers 25000.00 75000.00 INR Seventy Five Thousand Only
marking plan within 10 days from the date of initiation of work for approval of
RITES. Mapping over the structural members at the site with good quality
paint (for visibility at day & night) with indication of width, length and depth.
2 NDT FOR RCC STRUCTURES

2.01 Rebound Hammer Test: For determining the estimated compressive


strength of concrete and uniformity of concrete in terms of surface hardness
INR Fifty Seven Thousand Seven Hundred & Fifty
as per IS 13311 (Part-2)-1992, also establishing correlation chart between 330 Nos 175.00 57750.00
Only
rebound hammer and other confirmatory test for estimated in-situ strength of
concrete if required.
2.02 Ultrasonic Pulse Velocity Test: for ascertaining the quality of concrete,
INR One Lakh Twenty Five Thousand Four Hundred
soundness and density of concrete, uniformity of concrete in terms of density 330 Nos 380.00 125400.00
Only
as per IS 13311 (Part-1)-1992.
2.03 CORE Sampling and Testing (Partially Destructive Test): Extracting the
concrete core samples at select locations from RCC members of the
structures covered under the study and evaluating the properties fck value,
grade of concrete in the laboratory from the core samples selected. IS
456:2000; IS516:1959, IS 1199:2002; without encountering any steel
18 Nos. of Set 12000.00 216000.00 INR Two Lakh Sixteen Thousand Only
reinforcement from the RCC members at specified locations by site in-charge
with portable power driven core cutting equipment. After extraction of core
from the structures, each core extraction/cutting location shall be filled with
epoxy materials asper standard practice and codal guide lines.
(1 Set = 3 Nos. of Core)
2858
508

2.04 Carbonation Test: Measurement of carbonation depth by phenolphthalein


spray test at selected locations on RCC members of the structures covered
under the study to see the depth of carbonation as per BS EN 14630:2006, 142 Nos 1500.00 213000.00 INR Two Lakh Thirteen Thousand Only
BS EN 13295:2004. Ratio of Carbonation depth to cover depth is also
measured to check the intensity of carbonation attack on steel bar
2.05 Determination of pH, Chloride & Sulphate Content : Water Soluble
Chloride & Sulphate Content % (by mass of concrete) to check the risk of
corrosion due to present chloride % as per IS: 14959 (Part 2) – 2001, B.S.
70 Nos 2000.00 140000.00 INR One Lakh Forty Thousand Only
5328 Part 1, ACI 201.2R-92, BS 1881 Part 124:1988, BS 8110, IS 456:2000
and other relevant Codes. pH Value (to check alkanity of concrete) as per
relevant B.S. 5328, ACI 201.2R-92 and ACI-318-99, IS 456:2000, BS 8110.
2.06 Cover Depth Test :RCC details by using ferro-scanner for measuring the
cover depth by using cover meter and existing protecting layer of steel rebar,
54 Nos 1200.00 64800.00 INR Sixty Four Thousand Eight Hundred Only
diameter of steel and number of rebar, Preparation of structural details of
RCC sections.
2.07 Half Cell Potential Test :Measuring the Half Cell Potential readings with
electrode at the nodes of pre-marked grid points on concrete surface in a
suitable grid for determining the probability of corrosion activity of embedded
steel reinforcement in concrete with specified half cell electrode in
accordance with ASTM C876-1980 after moistening the concrete surface
with water. The rate shall include surface preparation, moistening concrete
INR Forty Three Thousand Seven Hundred & Fifty
surface for assessing the percentage risk of corrosion in reinforcement, 35 Nos 1250.00 43750.00
Only
Measuring the half-cell / surface potentials at selected locations on RCC
members of the structures covered under the study to understand the extent
of reinforcement corrosion and contour Mapping of corrosion, Plotting the
half cell potential readings in graphical presentation with potential contours
plotted in terms of probable risk of corrosion of steel bar as per ASTM C876
[6]-1991.
2.08 Resistivity Meter Test : It is used in determination of Estimation of the
likelihood of corrosion, Indication of corrosion rate, Correlation to chloride
permeability, Determination of zonal requirements for cathodic protection
35 Nos 2500.00 87500.00 INR Eighty Seven Thousand Five Hundred Only
systems, Identification of areas within a structure most susceptible to chloride
penetration as per BS EN 12696:2000, RILEM TC-154, AASHTO T277 RCP,
AASHTO T259, ASTM C 1202 971
2.09 RCC Mapping by GPR/Section Profiling : Mapping of reinforcement in
RCC members by using x-ray/magnetic based scanner at doubtful location in
the grid size of 600x600mm; each picture shot and plotting of the same
details on drawings measuring the cover depth and existing protecting layer 70 Nos 2500.00 175000.00 INR One Lakh Seventy Five Thousand Only
of steel rebar, diameter of steel and number of rebar, Preparation of
structural details of RCC sections spacing of bar up to 300mm -450 mm
depth, Very high frequency Hz GPR

3 NDT FOR STEEL STRUCTURES

3.01 Liquid Penetration Testing : To reveal surface breaking flaws by bleed out
of a colored or fluorescent dye from the flaw as per ASME standards refers
400 Nos 500.00 200000.00 INR Two Lakh Only
to the ASME Code Section V Article 6 and ASME VIII Div 1 Appendix 8 and
other relevant sections/guidelines.
3.02 Ultrasonic Pulse Eco Testing of Metallic Sections:- For assessment of

welding/joints assessment of Steel Plates/Tube/Pipe Weld/Forging/Casting 400 Nos 1000.00 400000.00 INR Four Lakh Only

as per ASTM A-435/A435M-82 ASME Sec V, range (0mm-5000mm).


3.03 Dry Film Thickness:- Dry film / Coating thickness of external surface
materials (paint, anti-corrosive coating etc..) on Ferrous and Non-ferrous 190 Nos 250.00 47500.00 INR Forty Seven Thousand Five Hundred Only
Metals/Alloys as per IS: 3023 Up to 1000 micron.
2859
508

3.04 Magnetic Particle Testing Ferrous Metals as per ASTM-709, 1995; ASME
Sec-5, 200; ASTM A275 range(Up to 3mm depth) to assess the 440 Nos 500.00 220000.00 INR Two Lakh Twenty Thousand Only
cracks/joints/welding conditions rang
3.05 UT Thickness for Steel Section Size Assessment:- Local thickness of a
solid/hollow element based on the time taken by the ultrasound wave to
190 Nos 500.00 95000.00 INR Ninety Five Thousand Only
return to the surface as per ASTM E797 / E797M for section detailing of steel
members.
3.06 Hardness Testing of metals: Hardness of Ferrous & Non-ferrous

Metals/Alloys Vickers 80-94; HRC 17.9-68.5 HRB 13.5-99.5, LD 200-900, 40 Nos 400.00 16000.00 INR Sixteen Thousand Only

HB 82.0-940.0 to get the type of material and its estimated tensile strength.
3.07 Inspecting torque/Tension on Nut/ Bolt: To determine the torque to a
fasten nut or bolt permits proper tension and loading wherever bolts are
loose and found deteriorated. Check torque applied to the nut/bolt so it can
be matched to the specifications as per codal requirement IS 6623: 2004.
Also check the gap between bolt/nut using filler gauge. When nuts and bolts 10 Nos 8000.00 80000.00 INR Eighty Thousand Only
are fastened together under load the action of tightening the nut increases
the force applied to the bolt causing elongation. Bolt tension monitors should
be also used to accurately measure the elongation, stress, and %strain of
the bolt during traffic load in 5% intact bolts.
3.08 Mechanical Testing of Loosened Bolt : To evaluate the mechanical
properties like Tensile Strength and Shear Strength of the bolt and to 12 Nos 4000.00 48000.00 INR Forty Eight Thousand Only
evaluate the grade of bolt.
3.09 Radiography test for weld/lamination, as per field requirement. Test should
be conducted the conducted under the supervision of approved radioactive 9 Nos 10000.00 90000.00 INR Ninety Thousand Only
system operator (license holder from Govt.).
2860
508

4 Load Testing and Miscellaneous

4.01 Geotechnical Survey: Carrying out Geotechnical soil investigation work by


tools & plants as per Indian codal provisions and site requirement. Drilling of
150mm dia Bore Hole (BH) in approaches of flyovers for a depth o approx.
15m or refusal strata whichever is earlier, including providing and supplying
4 Nos of BH 150000.00 600000.00 INR Six Lakh Only
of wooden core boxes for samples, logging of all bore holes and also
includes preparation of reports, conducting of various field and lab tests as
per scope of work, complete all as per specifications/latest relavent IS codes
and as per instructions of Engineer in Charge.
4.02 Static Load Testing of the bridges/flyover for all Flyovers : Conducting
load testing on already constructed deck slabs and assessment of its load
carrying capacity as per latest guidelines of IRC and other relevant
standards. The rating of the structure shall be assessed both using
8 Nos 600000.00 4800000.00 INR Forty Eight Lakh Only
Analytical Method & through Load Testing. A comparative chart to be plotted
between observed v/s theoretical strain and deflection against the sequence
loading up to full proof loading. Traffic Diversion Plan and Contingency plan
shall also be prepared.
4.03 Dynamic load test on the flyover/bridge spans: Evaluate the dynamic
behavior of bridge with calculation of various parameter like strain, vertical
deflection, vibration and lateral movement near the expansion joints through
correlation with the identified peaks and traffic loads and full load test. 3 Nos 200000.00 600000.00 INR Six Lakh Only
Sensors to be installed 3-Axis Accelerometer (Vibration due to Traffic
movement & Displacement), Strain Gauge (Strain value) & LVDT Sensor
(Displacement/crack movement).
4.04 Condition Assessment of the each and every Bearings & expansion
joint of flyover: Each and every bearing identification along with
3 No. of flyovers 100000.00 300000.00 INR Three Lakh Only
photograph of their present condition, suggestion for replacement or
maintenance if required immediate marked over the drawing.

5 PREPARATION & SUBMISSION OF DPR

5.01 Specialized consulting firm /Agency shall prepare and submit the DPR of
each flyovers/bridge in 3 copies which includes all inspection and NDT
results, interpretation of test results, load test reports, conclusion, site
photographs,
h t h scheme
h for
f repair/rehabilitation/
i / h bilit ti / retro-fitting
t fitti works
k with
ith BOQ
and Rate analysis, technical Specifications, design and execution drawing
3 No. of flyovers 150000.00 450000.00 INR Four Lakh Fifty Thousand Only
(feasible and economic options) for rehabilitation/strengthening of flyovers,
improvement of drainage system, traffic diversion plan, bridge inspection and
maintenance manual including QAP, safety and environmental plan. HD
quality site photographs and Video during inspection & testing shall be
provided in a good quality CD/DVD/USB hard disk..

INR Ninety One Lakh Forty Four Thousand Seven


Total in Figures 9144700.00 Hundred Only

INR Eighty Eight Lakh Seventy Thousand Three


Quoted Rate in Figures Less (-) 3.00% 8870359.00 Hundred & Fifty Nine Only

Quoted Rate in Words INR Eighty Eight Lakh Seventy Thousand Three Hundred & Fifty Nine Only

You might also like