You are on page 1of 14

HCPA-Transmission&Access Series

eSight-PON POL Simplified O&M


Promotional Theme Slides

Department: Transmission & Access Product Line-NCE-FAN Service Product Unit


Author: Gong Kebing
Date: May, 2020

Security Level:
What Is POL
A Passive Optical LAN (POL) is a flat access network consisting of an optical
line terminal (OLT), optical network unit (ONU), and passive optical distribution
network (ODN).

OLT
ODN

ONU Cloud

GPON / 10G PON

• Passive devices • Open access to the


• Simplified network
replacing active cloud
Simple • One fiber for multiple Reliable Flexible
devices • Centralized device
services
• Fiber replacing copper management

2 Huawei Confidential
POL OptiX Campus Has Been Widely Used in the World

200+ 350+ 100+ 60+ 30+

Offices Hotels Education Public security Energy & transportation


institutions projects projects
Sochi Olympic Park (Russia)
Bourne Leisure (UK) Islamabad Safe City Project

Enel Italy FAW Group in Changchun


Hospital Local Candelaria in Spain SGCC
Madinat Jumeirah/City Walk in Dubai Beijing Jiaotong University
Melville Headquarters in New York Highway in Yantai
San Diego Central Library China Railway Zhengzhou Group
Temptation Cancun Resort (Mexico) YOFC's Qianjiang Science and
Technology Park
Southwest University
Macao Roosevelt Hotel
EGAT park (Thailand)
Australia: Singapore Changi Airport
Aloft Hotel
Skytower

3 Huawei Confidential
POL O&M Requires Support from Innovative Solutions and
Technologies POL service provisioning: Service provisioning by using command lines is
complex and inefficient. A service provisioning process that is easy to
understand, graphical, and has low requirements on personnel is required.
POL maintenance: No tool is available for locating some faults of POL OptiX
Campus. A tool that can quickly locate and rectify faults is required.

Campus construction is shifting from IP to Datacom Access

POL, but the skills of delivery and


maintenance personnel are not updated.
As a result, access engineers are
insufficient, further hindering POL O&M. Delivery channel Campus O&M

The Switch configuration is


simple and mainly about VLAN.
The POL configuration is flexible
and has many PON protocol
parameters such as T-CONT,
GEM port, and GEM mapping,
which makes learning and
understanding difficult.

4 Huawei Confidential
eSight: an ICT Full Lifecycle O&M System Built for Enterprises
Unified management Intelligent O&M
 Unified cross-domain management  Centralized alarm monitoring
 Unified topology view  Visualized diagnosis
 Unified resource reports eSight  Intelligent capacity analysis

Unified ICT management


Data center (DC) Campus/WAN branch Public safety (video surveillance)

Server, storage, and DC network

Router, switch, firewall, and WLAN Server, switch, storage, surveillance system, and
camera

IP wireless eLTE terminal & POL network


network module
Power, environment, and cooling Camera
Camera
OLT ONT
Switch, eLTE, and microwave

eSight-PON is an eSight component dedicated


for POL network management.
5 Huawei Confidential
eSight-PON Builds Simplified POL O&M, Achieving "Only One
Engineer Required for the Management of One Campus"
Provisioning upon Intuitive information Quick fault
installation display diagnosis

ONT plug-and-play Visualized POL campus network Real-time alarm notification and fast fault
 Remote ONT authentication  Customized large-screen display diagnosis
 Automatic service provisioning  Visualized locations and status of  Visualized fault topology & real-time
Switch-like service configuration, nodes and links alarm notification
ordered on demand  Real-time campus traffic monitoring  Service emulation test and fast fault
demarcation (Q2 of 2020)
 E2E diagnosis of camera failures

eSight-PON
Simplified POL O&M

POL OptiX Campus


6 Huawei Confidential
Provisioning upon Installation: Services Provisioned Within
1 Minute After an ONT Is Powered On
AS-IS TO-BE
 Each ONT configured on the web page, high skill requirements, time-consuming  Remote ONT authentication, and automatic service provisioning on
eSight
 CLI-based configuration being complex, with high skill requirement  Switch-like service provisioning and configuration on eSight, ordered
 Services provisioned ONT by ONT, no batch service provisioning on demand

ONT plug-and-play Simple service provisioning & configuration on eSight

Switch-like configuration Services provisioned on demand


3. eSight checks VLAN VLAN VLAN VLAN
whether the ONT 1000 1001 1002 1003
eSight ONT Service Options
complies with the ETH port
service provisioning
policy. Option Required Setting

4. eSight issues
OLT Broadband Service VLAN, OLT-side
2. The OLT reports configurations to the PON parameters service inner/outer VLAN, service
an ONT auto- OLT and ONT to automatically rate limit
discovery event. provision services.
configured on
Wi-Fi Wi-Fi name and password
eSight
service
ONT
Monitoring Service VLAN, OLT-side
ETH port
1. The ONT is service inner/outer VLAN
ONT OLT Untag VLAN VLAN VLAN
powered on. 100 200 300
Voice Service VLAN, user VLAN,
service SIP server address

The ONT works upon power-on and does not need to be After the process is simplified, automatic Services can be selected as required, and related
configured onsite. service provisioning is achieved. settings are provided.
Services are provisioned within 1 minute after ONT power-on.
7 Huawei Confidential
Intuitive Display of POL Campus Network Information
AS-IS TO-BE
 Invisible device location details or link information  Visualized locations and status of nodes and links
 Invisible status of device alarms and link alarms  Real-time fault status detection
 Invisible KPIs, and unclear network status  Real-time campus traffic monitoring
 No real-time statistics on network-wide resources  Real-time network-wide resource statistics

Customized large-screen display Unified topology monitoring Real-time campus traffic monitoring
Topology Alarms Campus traffic

√ X √ Download rate of the upstream


Rate ETH port on the OLT
ONT status Camera status LTE call drop rate 3A-2F-01 ONT

√ X √ Outbound
bandwidth
3A OLT 3A-2F optical splitter

Video quality Channel usage Voice quality 3A-2F-02 ONT

√ √ X T

 Visualized nodes/links: OLT-to-ONT links


 Customized large-screen display to focus automatically generated
on key objects, facilitating campus  Visualized node positions: topology background Real-time monitoring of campus
monitoring. images customizable, and icons able to be dragged outband bandwidth usage to confirm
 100+ modules available, such as network to a specified position bandwidth usage
traffic, service quality, device status, and  Configurable device names: device names can be
alarm information changed to location names, improving readability
8 Huawei Confidential
Quick Fault Diagnosis: Real-Time Alarm Notification and
Quick Fault Locating
AS-IS TO-BE
• Time-consuming for determining the root cause among the various • Visualized fault topology & real-time alarm notification
possible causes of service interruption • Service emulation tests to quickly determine whether a fault is caused
• Difficult for users to know whether a fault is on the ONT side or on the on the user side
PC side • E2E service fault diagnosis & one-click root cause diagnosis

Real-time alarm notification Service emulation tests (Q2 of 2020) E2E service fault diagnosis

PPPoE emulation test DHCP emulation test


eSight

SMS notification
Email notification
Topology display
eSight
X X X X X
Alarm reporting IPC ONT SPL OLT Switch Switch VNC

X
ONT OLT

(Public safety industry) For camera failures:


 Alarm information displayed and refreshed in the  E2E link restoration for camera services
Service emulation tests to quickly determine whether a
topology in real time  One-click fault root cause diagnosis (faulty node/fault
fault is caused on the user side
 Customized SMS notifications on major alarms for cause)
maintenance personnel
9 Huawei Confidential
eSight Deployment Solution

Management Local Server Deployment (Single-Node VM Deployment (Single- Operating


DB
Scale System) Node System) System

CPU: 24 vCPU
0–5000 Memory: 64 GB EulerOS GaussDB
Hard disk space: 500 GB
Taishan2280-02-(2 x Kunpeng 920 4826,
4 x 32G memory, 2 x 1920GB SSD, 8 x
GE, 2 x 900 W AC power supply)
CPU: 48 vCPU
5001–20000 Memory: 128 GB EulerOS GaussDB
Hard disk space: 1 TB

10 Huawei Confidential
Basic Trustworthiness Capabilities of eSight

•Open source management: normalized third-party •System restoration: quick backup and restoration
software of databases and applications
•Security protocol algorithms: check and •Fault detection: node, service, and database
rectification against insecure protocols and health check and warning by the management
algorithms plane
•Certificate management: unified certificate
management and updates
•System integrity protection: digital signature
•Isolation: multiple isolated planes
High reliability
Security
High availability

Resiliency Privacy
protection

•Security detection: interconnected with HiSec to •Privacy protection, GDPR compliance


manage system, operation, and security logs and
detect security risks
•Security response and recovery: interconnected
with CIS and TIC systems to manage vulnerabilities
and respond to emergencies

11 Huawei Confidential
Tsinghua University Staff Dormitory Network
1. Requirements and challenges
• The world's first-class university covers an area of more than 450 hectares and has
more than 60,000 students. The existing dormitory network of faculty members has
great security risks (such as unauthorized access to the network).
• A future-oriented, stable, and reliable campus network that provides ultra-
broadband and is easy to operate and maintain is required.
2. 3. Huawei solution
• The POL solution achieves unified transmission and management of all services. It
is simple to deploy. It builds an intelligent OptiX Campus network.
CO
• eSight is used for the O&M of the POL network, which provides intuitive network
eSight
information and enables automatic fault diagnosis.
Weak-
3. Customer benefits current
well
Internet ONU Dormitory

• Network access experience is better, network security is greatly improved, and


CERNET EA5800-X7
wireless security source tracing can be achieved. 1:32
optical ONU Dormitory
splitting
• eSight monitors the POL network in real time, visualizes resources in real time, and
detects faults in real time.
• ONTs are plug-and-play, reducing network maintenance costs.
12 Huawei Confidential
Thank you. 把数字世界带入每个人、每个家庭、
每个组织,构建万物互联的智能世界。
Bring digital to every person, home and
organization for a fully connected,
intelligent world.

Copyright©2018 Huawei Technologies Co., Ltd.


All Rights Reserved.

The information in this document may contain predictive


statements including, without limitation, statements regarding
the future financial and operating results, future product
portfolio, new technology, etc. There are a number of factors that
could cause actual results and developments to differ materially
from those expressed or implied in the predictive statements.
Therefore, such information is provided for reference purpose
only and constitutes neither an offer nor an acceptance. Huawei
may change the information at any time without notice.
Intuitive Network Information Display:
Customizable background images
Unified Topology and Monitoring A user can set the top view of a campus as the
topology background and drag devices to desired
positions to improve the topology readability.
eSight-PON topology view
Links automatically generated and their
status displayed in real time
1. OLT-SPL-ONT links are automatically generated.
2. Feeder cable alarms and distribution cable alarms
are automatically displayed on the topology view.

ONT status displayed in real time


Online, offline, and power-off states of ONUs are
displayed in different colors.

ONT names configurable


A user can manually an ONT name to a room name in
the topology view to improve readability.

Topology-centric redirection
A user can switch to the service provisioning, fault
maintenance, and details pages in one-click mode.

14 Huawei Confidential

You might also like