Smart Thermostat
230 V Relay Installations
Guide for Professional Installers
Optional Accessory 5
1. Wiring
5. Configuration 14
Do not use the tado° relay to switch the main electrical
supply to the boiler!
08/2018
4
Optional Accessory
Use the tado° Trim Plate behind the Smart Thermostat or Extension
Kit if needed. This can be obtained separately at tado.com/trim-plate
5
1. Wiring: Smart Thermostat
Combi Boilers (Dry Contacts)
Wired Setup: Smart Thermostat is wired directly to the boiler
Smart Thermostat
Boiler
MAX 230 V AC
6(4) A
Smart Thermostat
Parking
Terminals
6
1. Wiring: Extension Kit
Combi Boilers (Dry Contacts)
Wireless Setup: Smart Thermostat installed wirelessly with receiver
Boiler
COM NC NO
Extension Kit
MAX 230 V AC
6(4) A 1
Jumper Position 1
7
1. Wiring: Extension Kit
S-Plan Setups (Switched Live)
Wireless Setup: Smart Thermostat installed wirelessly with receiver
Boiler
HW CH HW CH
OFF OFF ON ON
Extension Kit
MAX 230 V AC
6(4) A
2
Jumper Position 2
8
1. Wiring: Extension Kit
Y-Plan Setups (Switched Live)
Wireless Setup: Smart Thermostat installed wirelessly with receiver
Valve
Boiler
HW CH HW CH
OFF OFF ON ON
Extension Kit
MAX 230 V AC
6(4) A
2
Jumper Position 2
9
2. Connect Internet Bridge to Router
3 SEC
Blinking
4x short - pause - ...
2 MIN
Fast
Blinking
Blinking If failed:
2x short - pause - ... Restart pairing and make sure that the distance
between the devices is at least 3 m while pairing
11
4. Pair Smart Thermostat with Internet Bridge
2 MIN
3 SEC
If failed:
• Press the button to clear the error
• Restart pairing and make sure that the distance
between the devices is at least 3 m while pairing
12
Open Installer Menu
2 MIN
3 SEC 3 SEC
If failed:
• Repeat the process to open Installer Menu
• Make sure that the distance between the devices is
at least 3 m while loading the menu
13
5. Configuration
Wired Setup:
Smart Thermostat is wired
directly to the boiler
Select Heating No
Relay Circuit Hot Water
Smart Thermostat R01 HC01 Control
Wireless Setup:
Smart Thermostat installed
wirelessly with receiver
14
2 MIN
No
Extension Kit
Installation complete
1. Set the timer on the boiler
to “always heating”
2. Test the system
3. Hand over the registration
R01 for fully pumped systems card to the customer
R02 for gravity-fed systems
2 MIN
15
Get expert advice on the
tado° installer hotline:
or at
tado.com/installers