You are on page 1of 1

7.

3 Design of Longitudinal Girder


7.3.1 Design of LG
Girder size : 400x2000

A. Beam Force Detail Summary


Sign convention as diagrams:- positive above line, negative below line except Fx where positive is
compression. Distance d is given from beam end A.
Axial Shear Torsion Bending
Beam L/C d (m)
Fx (kN) Fy (kN) Fz (kN) Mx (kNm) My (kNm) Mz (kNm)
Max Fx 22926 1171 0.00 598.84 -189.79 1.71 -28.82 -28.04 -4146.53
Min Fx 4476 1305 0.00 -442.10 -185.00 1.28 -31.83 -27.10 -4194.05
Max Fy 22846 1168 0.00 14.99 1296.48 16.61 5.03 0.00 0.00
Min Fy 4729 1166 5.00 118.65 -968.61 14.71 -51.44 38.23 12.82
Max Fz 2384 1331 0.00 430.54 774.81 370.69 -11.06 0.00 0.00
Min Fz 4501 1331 0.00 101.88 659.33 -184.73 -92.40 484.64 -104.27
Max Mx 4843 1309 0.00 -32.18 906.86 -1.47 80.32 -4.75 -31.03
Min Mx 4843 1320 0.00 -350.21 -456.73 -8.28 -101.08 -0.69 -2812.02
Max My 23142 1161 0.00 101.88 659.33 -184.73 -92.40 484.64 -104.27
Min My 4859 1163 4.85 101.88 439.54 -184.73 -92.40 -411.28 -2769.03
Max Mz 4729 1166 5.00 585.10 -676.05 -8.33 -77.51 -42.61 27.95
Min Mz 22926 1170 2.50 107.26 -13.39 5.93 6.56 -5.04 -6808.49