You are on page 1of 8

3.

1 3D ANALYSIS OF BUILDING

3.1.1 FRAME MODEL

Y2

X3

X2

Y1

X1
Y

CHEMICAL DOSING EQUIPMENT SHED SUPERSTRUCTURE


STAAD Pro 3D MODEL
X1 X2 X3
4425 4425

1 2 3
Y2

6350

4 5 6
Y1

Y X

Joint Number Support Condition


1 TO 6 FIXED BUT MY MZ KMX 228

CHEMICAL DOSING EQUIPMENT SHED SUPERSTRUCTURE


SUPPORT LOCATION/ NUMBER
X1 X2 X3 X1 X2 X3 X1 X2 X3
4425 4425 4425 4425 4425 4425

H200X100X5.5X8

H200X100X5.5X8

H200X100X5.5X8
17 18 19 20 21

C150X75X6.5

C150X75X6.5
1000

36

42

37

43

38
22 23 24 25 26 13 14 15 16 H200X100X5.5X8 H200X100X5.5X8 H200X100X5.5X8 H200X100X5.5X8
Y2

H200X100X5.5X8

H200X100X5.5X8
0

0
L1

L1
X1

X1
17

19

00

00
00

00
X1

X1
47

49
46

48
24

26

X1

X1
00

00
00

00
X1

X1
L1

L1
0

0
H300X150X6.5X9

H300X150X6.5X9

H300X150X6.5X9
45 27 28 46

18
6350

H200X100X5.5X8

H200X100X5.5X8
0

0
L1

L1
X1

X1
00

00
00

00
X1

X1
50

52
51

53
78

25

27

X1

X1
00

00
00

00
X1

X1
79

L1

L1
0

0
H200X100X5.5X8

H200X100X5.5X8

H200X100X5.5X8
29 30 31 32 33 20 21 22 23 H200X100X5.5X8 H200X100X5.5X8 H200X100X5.5X8 H200X100X5.5X8

C150X75X6.5

C150X75X6.5
Y1
1000

39

44

40

45

41
34 35 36 37 38

Y X

ROOF FRAMING PLAN @ GL+5440~GL+6075 ROOF FRAMING PLAN @ GL+5440~GL+6075 ROOF FRAMING PLAN @ GL+5440~GL+6075
NODE NUMBER MEMBER NUMBER MEMBER SIZE
Y1 Y2 Y1 Y2
1000 6350 1000 1000 6350 1000

GL+6075 GL+6075 39
34 29 78

635
635

GL+5440 45 GL+5440 17
36
22 17

2
80
4840
4840

12
7

71

70
76 72
40 43 39

1
GL+600
GL+600 4 1

Y Y

FRAMING ELEVATION @ LINE X1 FRAMING ELEVATION @ LINE X1


Z X Z X
NODE NUMBER MEMBER NUMBER

Y1 Y2
1000 6350 1000

H200X100
GL+6075 X5.5X
H3800X1 50X6.5X9
H300X150
635

X6.5H2
H194X150X6X9 H194X150X6X9

GL+5440 X900X1 00X5.5X8

H194X150X6X9
H148X100X6X9
4840

H194X150X6X9
H194X150X6X9

H194X150X6X9
H194X150X6X9 H194X150X6X9

GL+600
Y

Z X
FRAMING ELEVATION @ LINE X1
MEMBER SIZE
Y1 Y2 Y1 Y2
1000 6350 1000 1000 6350 1000

GL+6075 36 31 GL+6075 40
18
635

635
GL+5440 24 19 GL+5440 37

10

4
14
4840

4840
9

3
GL+600 5 2 GL+600

Y Y

FRAMING ELEVATION @ LINE X2 FRAMING ELEVATION @ LINE X2


Z X Z X
NODE NUMBER MEMBER NUMBER

Y1 Y2
1000 6350 1000

H200X100X5.5X
GL+6075 8
H300X150X6.5
635

X9
GL+5440 H200X100X5.5
H194X150X6X9

X8

H194X150X6X9
4840

H194X150X6X9

H194X150X6X9

GL+600
Y

Z X
FRAMING ELEVATION @ LINE X2
MEMBER SIZE
Y1 Y2 Y1 Y2
1000 6350 1000 1000 6350 1000

GL+6075 GL+6075 41
38 33 79
635

635
46 19
GL+5440 GL+5440 38
26 21

74

81

73
42 44 41 77 75

12
4840

4840
16

6
11

11

5
GL+600 GL+600
6 3

Y Y

FRAMING ELEVATION @ LINE X3 FRAMING ELEVATION @ LINE X3


Z X Z X
NODE NUMBER MEMBER NUMBER

Y1 Y2
1000 6350 1000

GL+6075 H200X100
X5.5X
H3800X150
X6.5X 9
635

H300X150
H194X150X6X9

GL+5440 X6.5H2
X900X100X5

H148X100X6X9
.5

H194X150X6X9
X8
H194X150X6X9

H194X150X6X9
H194X150X6X9 H194X150X6X9
4840

H194X150X6X9

H194X150X6X9
Y GL+600

Z X
FRAMING ELEVATION @ LINE X3
MEMBER SIZE
X1 X2 X3 X1 X2 X3
4425 4425 4425 4425

GL+6075 29 30 31 32 33 GL+6075 20 21 22 23
2735

2735

65

69
63

67
10

12
8
GL+3340 12 13 14 15 16 GL+3340 32 33 34 35
2740

2740

62

66
64

68

11
7

9
GL+600 4 5 6 GL+600

Y Y

FRAMING ELEVATION @ LINE Y1 FRAMING ELEVATION @ LINE Y1


Z X Z X
NODE NUMBER MEMBER NUMBER

X1 X2 X3
4425 4425

GL+6075 H200X100X5.5X8 H200X100X5.5X8 H200X100X5.5X8 H200X100X5.5X8


H194X150X6X9

H194X150X6X9

H194X150X6X9
2

2
L1

L1
X1

X1
30

30
30

30
2735

X1

X1
X1

X1
30

30
30

30
X1

X1
L1

L1
2

2
GL+3340 H200X100X5.5X8 H200X100X5.5X8 H200X100X5.5X8 H200X100X5.5X8
H194X150X6X9

H194X150X6X9

H194X150X6X9
2

2
L1

L1
X1

X1
30

30
30

30
2740

X1

X1
X1

X1
30

30
30

30
X1

X1
L1

L1
2

2
GL+600

FRAMING ELEVATION @ LINE Y1


Z X
MEMBER SIZE
X1 X2 X3 X1 X2 X3
4425 4425 4425 4425

GL+5440 22 23 24 25 26 GL+5440 13 14 15 16
2420

2420

57

61
55

59
2

6
GL+3020 7 8 9 10 11 GL+3020 28 29 30 31
2420

2420

54

58
56

60
1

5
GL+600 1 2 3 GL+600

Y Y

FRAMING ELEVATION @ LINE Y2 FRAMING ELEVATION @ LINE Y2


Z X Z X
NODE NUMBER MEMBER NUMBER

X1 X2 X3
4425 4425

GL+5440 H200X100X5.5X8 H200X100X5.5X8 H200X100X5.5X8 H200X100X5.5X8


H194X150X6X9

H194X150X6X9

H194X150X6X9
2

2
L1

L1
X1

X1
30

30
30

30
2420

X1

X1
X1

X1
30

30
30

30
X1

X1
L1

L1
2

2
GL+3020 H200X100X5.5X8 H200X100X5.5X8 H200X100X5.5X8 H200X100X5.5X8
H194X150X6X9

H194X150X6X9

H194X150X6X9
2

2
L1

L1
X1

X1
30

30
30

30
2420

X1

X1
X1

X1
30

30
30

30
X1

X1
L1

L1
2

2
GL+600

FRAMING ELEVATION @ LINE Y2


Z X
MEMBER SIZE

You might also like