Professional Documents
Culture Documents
3.1 Summary of Calculations
3.1 Summary of Calculations
Limit,FOS 1.25
Ratio 1.33
Check OK
Actual,FOS 2.00
Overturning
Limit,FOS 1.50
Ratio 1.34
Check OK
504.93
Contact Base Pressure
2
Actual Soil Pressure ( kN/m )
With Backside Water Pressure
300.00
Allowable Soil Pressure ( kN/m2 )
Long Term
1.68
Ratio
NG
Check
532.04
Contact Base Pressure
2
Actual Soil Pressure ( kN/m )
375.00
Allowable Soil Pressure ( kN/m2 )
Short Term
1.42
Ratio
NG
Check
Actual Settlement, mm 85.74
Settlement
Ratio 1.71
Check NG
Actual,FOS 4.26
Sliding
Limit,FOS 1.50
Ratio 2.84
Check OK
Actual,FOS 6.02
Overturning
Limit,FOS 1.50
Ratio 4.01
Check OK
Without Backside Water Pressure
286.13
Contact Base Pressure
2
Actual Soil Pressure ( Kn/m )
300.00
Allowable Soil Pressure
Long Term
0.95
Ratio
OK
Check
Contact Base Pressure
Check OK
Actual Settlement, mm 46.64
Settlement
Sliding
Limit,FOS 1.25
Ratio 2.84
Check OK
Actual,FOS 4.17
Overturning
Limit,FOS 1.50
Ratio 2.78
Check OK
393.17
Contact Base Pressure
2
Actual Soil Pressure ( kN/m )
300.00
In Dry Condition
Stability Check
NG
Check
Contact Base Pressure
2 402.01
Actual Soil Pressure ( kN/m )
Check NG
Actual Settlement, mm 64.19
Settlement
Shear Check
Abutment Stem
Ratio 1.69
Check NG
Actual, Mpa 4.87
Allowable, Mpa 8.5
Stress on Concrete
Ratio 0.57
Without Backside Water Pressure
Check OK
Actual, Mpa 71.32
Allowable, Mpa 240
Stress on Comp. Steel
Ratio 0.30
Check OK
Actual, Mpa 231.01
Allowable, Mpa 240
Stress on Tension Steel
Ratio 0.96
Check OK
Force,Mpa 0.22
Capacity,Mpa 0.23
Shear Check
Ratio 0.93
Check OK
Type of check
Value Remarks
Provided(mm2),
28d@140 4398.57
2
X-Direction Required(mm ), 5894.98
Ratio 1.34
Check NG
Top
Provided(mm2),
20d@180 1745.56
2
Y-Direction Required(mm ) 2264.4
With Backside Water Pressure
Ratio 1.30
Check NG
Provided(mm2),
32d@110 7311.82
2
X-Direction Required(mm ) 4871.8
Ratio 0.67
Bottom
Check OK
Provided(mm2),
20d@180 1745.56
Y-Direction Required(mm2) 2259.6
Ratio 1.29
Check NG
Force,Mpa 0.361
Abutment Foundation
Capacity,Mpa 0.27
Shear Check
Strength Check
Ratio 1.34
Check NG
Provided(mm2),
28d@140 4398.57
X-Direction Required(mm2), 2348.6
Ratio 0.53
Check OK
Top
Provided(mm2),
20d@180 1745.56
2
Y-Direction Required(mm ) 2264.4
Without Backside Water Pressure
Check OK
Provided(mm2),
20d@180 1745.56
Y-Direction Required(mm2) 2259.6
Governed By Min, 0.12%
Ratio 1.29
Check NG
Force,Mpa 0.189
Capacity,Mpa 0.27
Shear Check
Ratio 0.70
Check OK
Type of check
Value Remarks
Provided(mm2),
28d@140 4398.57
X-Direction Required(mm2), 4309.71
Ratio 0.98
Check OK
Top
Provided(mm2),
20d@180 1745.56
2
Y-Direction Required(mm ) 2264.4
Governed By Min, 0.12%
Ratio 1.30
Abutment Foundation
Check NG
In Dry Condition
Strength Check
Provided(mm2),
32d@110 7311.82
2
X-Direction Required(mm ) 4303.8
Ratio 0.59
Bottom
Check OK
Provided(mm2),
20d@180 1745.56
Y-Direction Required(mm2) 2259.6
Governed By Min, 0.12%
Ratio 1.29
Check NG
Force,Mpa 0.132
Capacity,Mpa 0.22
Shear Check
Ratio 0.60
Check OK
FOS : Factor of safety