You are on page 1of 94

Transient Multiphase

_GET
Flow Simulator
STARTED
Enabling reliable and efficient flow of production fluids

be dynamic
Graphical User Interface (GUI).

VERSION 5.2
OLGA - at the heart of production.
®
OLGA VERSION 5 Get Started Page i

TABLE OF CONTENTS
Page

1. INTRODUCTION 1

2. STARTING THE PROGRAM 2

3. THE OLGA OVERALL STRUCTURE 2


3.1 GUI Object model 2
3.2 Pipe model 3
3.3 Files and file extensions 4
3.4 Organizing and working with Projects and Cases 4
3.4.1 Converting OLGA 2000 input files 7

4. SELECTING THE SIMULATION ENGINE AND OTHER SETTINGS 9

5. GUI LAYOUT 12
5.1 Start page 12
5.2 The Graphic editor 13
5.2.1 Network view 13
5.2.2 Flow path view 25
5.2.3 3-D view 27
5.3 Model view 28
5.4 File view 29
5.5 Components view 30
5.6 Properties 31
5.7 Output view 32

6. CASE DESIGN 34
6.1 New project 34
6.2 New case 34
6.2.1 Build from empty template 35
6.2.1.1 Case information 35
6.2.1.2 Flowpath 35
6.2.1.3 Complete the defined objects 36
6.2.1.4 Changing a global label 36
6.2.1.5 Add new objects 38
6.2.1.6 Copy/Paste 38
6.2.1.7 Define output variables 39
6.2.1.8 Activate OLGA Viewer 44
6.3 Open existing projects/cases 45
6.3.1 Open project 45
6.3.2 Open case 45

7. INPUT EDITORS 46
7.1 Time series editor 46
7.2 INITIALCONDITIONS and HEATTRANSFER 47
7.2.1 Initial conditions 47
7.2.2 Heat transfer 51

8. GEOMETRY EDITOR 55
8.1 Activating 55
8.2 Enter a new profile 56
8.3 Edit Geometries 58
8.3.1 Edit the table 59

i
OLGA VERSION 5 Get Started Page ii

8.3.2 Edit the graph 59


8.3.3 Check angle distribution 60
8.3.4 Filter the data 60
8.3.5 Complete the data 61
8.3.6 Define sectioning 61
8.3.7 Use the new geometry 63
8.3.8 Menus 65
8.4 Limitations 66

9. PARAMETRIC STUDY 67

10. SIMULATION 73

11. VIEW YOUR RESULTS 74


11.1 Active case trend plot 74
11.2 Active case profile plot 76
11.3 Some general features of the plotting tool 78
11.4 Export/import data to/from MS Excel 78
11.5 Multi-case plotting 80
11.6 Fluid properties 82
11.7 OLGA Viewer 83
11.8 Menus 83
11.9 Reports 84

12. ONLINE HELP 85

13. GENERAL WINDOW OPERATIONS 86


13.1 Moving windows 86
13.2 Moving objects inside graphical editor 86
13.3 Hot keys 86
13.4 Moving view in 3D 87

14. MENUS 88
14.1 File 88
14.2 Edit 88
14.3 View 88
14.4 Project 89
14.5 Simulation 89
14.6 Tools 89
14.7 Windows 89
14.8 Help 89

15. TOOL BARS 90


15.1 Standard 90
15.2 Simulate 90
15.3 Plot 90
15.4 Layout 90

ii
OLGA VERSION 5 Get Started Page 1

1.INTRODUCTION
This document shall help you to get started with OLGA VERSION 5 which has a new
and different Graphical User Interface (GUI) compared to OLGA 2000.

The main new features of the GUI are:

Graphical configuration and visualization of complex networks with


• Drag and drop
• Graphical copy and paste
• Automatic detection and classification of internal nodes
• Positive flow direction can be indicated on flowpath
• Pressure boundary nodes are distinguished
• Network coupling table with configuration capability

Design time verification of model and listing missing items


• Errors are detected while the model is created
• Action buttons for missing items 1

GEOMETRY Editor with spreadsheet type input


ƒ Copy directly from Excel
ƒ Both XY and Length-Elevation input are displayed.
ƒ Automatic Sectioning without simplification
ƒ Direct access to simplification procedure with new angle distribution details
ƒ Automatic inversion of pipe profiles which facilitates e.g. annular models

New Plotting Functions


• Select variables from a complete list with descriptions
• Make your own standard sets of variables with units
• Within a graph - copy directly to and from Excel

Spreadsheet type input and visualization of input series

New Parametric study function

New RESTART function

Context sensitive help

Main new features of OLGA version 5 are:


• Black-oil model
• General network steady state solver (use splitting nodes without initial
conditions)
- Also solves Compressors, Centrifugal pumps and Heat Exchangers
• Slug statistics

1
Some missing model elements can only be detected by running the OLGA simulator
1
OLGA VERSION 5 Get Started Page 2

2. STARTING THE PROGRAM

OLGA may be started in one of the following ways:

• Start menu -> OLGA -> OLGA


• Double click the OLGA icon on the desktop

3. THE OLGA OVERALL STRUCTURE

3.1 GUI Object model


The GUI works with objects, which are generally organized as follows (see also an
example of a "Model View" on the next page):

• Project-X Top level, a Project can hold several cases


o Case-XY1 Simulation information for Case-Y in Project-
X
ƒ Case definition Case title, author, date etc.

ƒ Network components Flowpaths with objects


ƒ Boundary and initial conditions
ƒ Piping
• BRANCH
• GEOMETRY
o PIPES
ƒ Process equipment
ƒ Output
NODES
ƒ Type and type specific input
ƒ Coordinates

ƒ FA-models Inputs for flow assurance modules like


ƒ Slugtracking
ƒ Waxdeposition
ƒ Corrosion etc.

ƒ Compositional Input for compositional models


ƒ AdvancedThermal Input regarding FEMTherm, Bundle etc.
ƒ Output Global output definitions
ƒ Library Keywords globally available
ƒ Materials
ƒ Walls
ƒ Drillingfluid etc.

o Case-XY2 Simulation information for Case-XY2 in


Project-X

o Case-XY3
o
o Case-XYn etc.

2
OLGA VERSION 5 Get Started Page 3

3.2 Pipe model


In the chapter above we have mentioned the term Flowpath. This is a prelude to our
next generation simulator (with the working name OPUS). Flowpath is a more general
term than Branch and comprises well tubing, special risers, topside piping etc.

In the OLGA GUI the Flowpath has only one keyword - namely its Label, while any
Branch has the same fixed label, i.e. BRANCH. In the model file that is sent to the
OLGA simulator the BRANCH key gets the label of the Flowpath.
3
OLGA VERSION 5 Get Started Page 4

When you open an OLGA 2000 .inp file with OLGA, ref. section 3.4.1, you will see
that the Flowpaths take the labels of the Branches in the original file.

Moreover, in the new GUI the Geometries must have separate labels. The
Geometries can be identical in all other respects, as before.

3.3 Files and file extensions


A Project has its own xml-file with the filename e.g. Test-C-5.opp (ref. previous
section). This file only refers to a collection of case files e.g. Case-0.opi, Case-01.opi,
etc., which also are xml-files and contain the input specifications etc.

When the case is run, the OLGA output files are produced. These are the same as
for OLGA 2000, with one exception. A text-file with the extension .geninp is also
printed. This is an OLGA 2000 legible input-file (you must change the .geninp to .inp)

The files with a ~ prefix e.g. ~Case-0.opi is the case file from the last save. With auto-
save on, ref. ch. 4, all case files in a project are saved with user-specified intervals.

3.4 Organizing and working with Projects and Cases


The "Project" concept is new to OLGA. The idea is that a Project contains references
to all files relevant to an OLGA project. This could include specifications, special
calculations in Excel, reports etc.

So far only the .opi files get a reference in the Project file (.opp) and this is done
automatically by the GUI.

The OLGA GUI requires that you work with a project and here are some ground-
rules:
When you open the OLGA GUI all projects accessible with your user account on your
network are listed on the GUI Front-page (you can hide the list in
TOOLSÆOPTIONS).
When you make your first project (or a new one), you can select to create a normal
explorer folder for the project (the folder gets the same name as the project).
By the same token you may select not to create a new folder but use an existing one.

If you start your session by making a New Project– the GUI will first ask you for the
name of a new project (.opp), and then you may create a New Case.

4
OLGA VERSION 5 Get Started Page 5

The window below opens and you can select a blank case (to start from absolute
scratch), a single-branch template (OLGA Basic) or a three-branch template (OLGA
Basic Network). The two templates are run-able cases.

5
OLGA VERSION 5 Get Started Page 6

Below you see a Model view of the OLGA Basic Network template case.

You can have only one Project open at the time2.


If you open another project you will be asked if you want to save the current one.
You can select save or save as and close the project (FILE menu).

You can create and keep the project files (.opp) and the case files (.opi) in separate
locations.
With “Save Project” you save the Project and the case files in their origins.

2
You can have several instances of OLGA with the same project open – actually working with
the same case. This should be used with great care.

6
OLGA VERSION 5 Get Started Page 7

You can add as many new cases as you like (FILE-menu) to your project. Existing
cases (from other Projects or OLGA 2000 .inp files) can be copied over to your
current project.

You can also remove a case from a project (case is not deleted, just de-coupled from
the project). All cases belonging to the project shall be visible in one of the GUI views
(Model or File- view).

3.4.1 Converting OLGA 2000 input files

When you have installed OLGA, you will notice that the OLGA 2000 input files have
been attributed with a special icon.

You can convert your OLGA 2000 input files (.inp) with the new GUI. The
straightforward way is to open a case with the GUI which then makes a project and a
case with the name of the original .inp file. If you open more .inp cases they will be
added to the project.

If you want to convert a folder of OLGA 2000 cases into OLGA format you can do as
illustrated below:

1. Select all the cases (e.g. shift left-click on the topmost case)
2. Drag the cases over to the e.g. Model view window in the OLGA GUI

The GUI will now make a project using the same name as one of the cases.

7
OLGA VERSION 5 Get Started Page 8

8
OLGA VERSION 5 Get Started Page 9

4. SELECTING THE SIMULATION ENGINE AND OTHER SETTINGS


The overall simulator settings are specified under Tools->Options; making it possible
to work with different simulation engines under the same GUI (this includes OLGA
2000 versions as long as it accepts the keywords you actually use).

Settings under the General tab are:

- My Project locations: Location where file dialogs will open.


- Show start page at start-up: If applied - start-page with recent projects will
appear when starting the GUI. A sub-setting is "show the project list on the start-
page".
- Use cached static data: This is set by default during installation. The GUI will
then store certain data the first time the simulator is started. This speeds up file
loading and is recommended to obtain the best performance from the program.

The General tab can also be used to specify if the program shall execute auto-save
at specified intervals.

OLGA is selected by checking “use OLGA” on the “OLGA” tab. The user interface will
then work with OLGA keywords, keys and variables, and the OLGA simulator will be
started when clicking the run button.

External programs that should be available from the Tools menu can be specified
under the External Tools tab. Some programs are set by default during installation
and the user can specify additional programs like Excel, a text-editor etc.

To check all keywords, rules etc. an OPUS3 simulation engine is used. The OLGA
Communicator tab is used to specify the version of OPUS.

The Graphics tab is used to specify the pipeline layout view:


- Turn the background grid on and off and specify the colours of the gridlines.
- Set the canvas colour.
- Choose the interpolation method for the flowpath lines.
- Set flowpath colour.

3
The working name for the next generation multiphase flow simulator under development by Scandpower
Petroleum Technology AS.
9
OLGA VERSION 5 Get Started Page 10

10
OLGA VERSION 5 Get Started Page 11

11
OLGA VERSION 5 Get Started Page 12

5. GUI LAYOUT

5.1 Start page


When opening the OLGA graphical user interface the Start page will appear. The
central window contains a list of recent projects and the date when they were last
modified. A project can be opened by clicking on the case name.

A new project can be started from the New Project button at the bottom of the screen.

12
OLGA VERSION 5 Get Started Page 13

5.2 The Graphic editor


5.2.1 Network view

Below you see a snapshot from the GUI with the template case Case0 loaded. All the
windows are described in the following sections. The windows may be moved around
(outside or inside the frame) and may be docked as described in section 13.1.

Click left button on canvas and


use mouse wheel to zoom in/out

The central view in the figure above shows the Network view with its Graphical editor
functions.

• Zooming in and out is done by the mouse wheel.


• Moving the mouse while the left mouse button is held down will move the layout
within the window.
• Pressing Q adjusts the graphical view to the frames. Holding Shift and pressing
Q zooms out in steps.
• Focus is shifted away from selected objects by pointing to the background while
holding down the Shift key.

Nodes and flow lines are drawn schematically. Network components (Nodes and
Flowpaths) can be dragged into this view from the “Components” window. Sources,
Pressure boundaries and Process equipment are visible and their properties may be
entered or modified by selecting the object (left-click) and filling in their “Properties”.
In the figure the properties of the NODE OUTLET are shown to the right.

13
OLGA VERSION 5 Get Started Page 14

Double click on
blue line:

The window above is the 2-dimensional Flowpath view which shows one Flowpath at
the time. The functions for "moving" the graph are the same as for the Network view,
ref. Ch. 5.2.2 for more details.

14
OLGA VERSION 5 Get Started Page 15

You can drag equipment to the canvas from the Process Equipment Components on the
left. When e.g. a valve is dropped on the canvas it "attach" to the middle of the Flowpath as
illustrated below. The actual position and other data for the valve can be entered in the
Properties window for the Valve which now is in focus (to the right).
By entering the data e.g. the PIPE and SECTIONBOUNDARY the valve will take its
specified position on the Flowpath.

Each graphic view has its own tab and if you click on the Case0-tab (see below) you get
back to the Network view.

Click here to get back to


Network view

Select NODE
and drag it onto
the canvas

How to make a new Flowpath:


Start with dragging a Node from the Components window and drop it on the canvas, as
shown above.

15
OLGA VERSION 5 Get Started Page 16

Then you make a new Flowpath by following the instructions in the drawing below:

To make a new flowpath:


Right-click in the blue square:
Keep right button down and drag
towards the OUTLET Node.
(the cursor looks like this- )

When the cursor looks like: +


release and select” Connect”
in the window below.

A new Flowpath has been added:

The new Node and Flowpath also appears in the Model View window, see below:

16
OLGA VERSION 5 Get Started Page 17

An alternative method for adding a Flowpath.

Select the Components window

Select a FLOWPATH and drag it to the canvas. Then drag a new node to the canvas.

17
OLGA VERSION 5 Get Started Page 18

A new Flowpath and a new


Node have appeared.

Then do as illustrated below.

1
Right-click on
canvas and
select Network
Connections.

2 Couple the Flowpath_1 From


OUTLET To NODE_1

18
OLGA VERSION 5 Get Started Page 19

Re-configure the network:

Move node(s) to
make the network
look better

Connecting Nodes and Flowpaths can be done as follows:


• Point to the red dot at one end of a Flowpath (the red dot indicates that
this
end of the Flowpath is not connected).
• Hold down the right mouse button, initially pointing to the blue square that
has appeared at the end of the Flowpath.
• Move the mouse pointer to the Node which the Flowpath should be
connected to and release.
• Select connect from the pop-up box that appears. The dot at the end of
the
Flowpath turns green, indicating that a connection is established.

Alternatively:
• Right-click on the view background and select Network Connections.
• Select the "from-to" nodes for each Flowpath and click OK. The network
should appear as specified.

19
OLGA VERSION 5 Get Started Page 20

Select Red dot on Flowpath

Right-click within the blue square and move pointer towards NODE_0. Select Connect to
…and release mouse button.

Do the same with the other end of the Flowpath.

20
OLGA VERSION 5 Get Started Page 21

Disconnect a Flowpath from a Node by left-clicking on the Flowpath and then point to the
green dot at the end of the Flowpath. Hold down the left mouse button while moving the
end of the Flowpath away from the node and release. The dot at the end of the Flowpath
should now be red, indicating that it is not connected.

Left-click on Flowpath, select green dot (left-click) and drag endpoint away from Node.

21
OLGA VERSION 5 Get Started Page 22

Right-click while pointing to an object in the Model view brings up various menus
depending on the object:

- Add : Add items to the network object.


- Verify : Checks input file and reports errors and missing input in the output view..
- Copy : Copy selected item.
- Paste : Paste the copied item onto the currently selected item.
- Delete : Delete selected object.
- Properties: Starts property editor for selected object. For a Flowpath this would be to
Geometry Editor while for other items it would typically be a time series editor.

For example: pointing to a Flowpath gives the alternatives below.

22
OLGA VERSION 5 Get Started Page 23

Text labels in the Network view (which reside in their separate text boxes) can be rotated
and scaled in addition to moved (except those for Flowpaths). Move is the default edit
mode.

You can either select the edit mode on the toolbar

m s r

or you can type one of the following letters to change the edit mode for the selected text
box.

s: Scale: (left-click in the triangle and drag


while keeping the mouse button down)

r: Rotate: (left-click in the sector and drag horizontally)

m: Move: (left-click in the square and drag)

You can add fixed points on a Flowpath by pressing Ctrl while double-clicking anywhere on
it. A fixed point, indicated by a small square, appears on the Flowpath.

The fixed points can be moved to shape the Flowpath (this does not change the actual
geometry of the Flowpath).

23
OLGA VERSION 5 Get Started Page 24

More points are added by repeating the Ctrl double clicking. You remove the fixed points
by Ctrl double click within its blue square.

Right-click in the Network view activates a menu with the following items:

A "Case.jpg" file with the Network view is copied to the folder where the project resides.

Network Connections: Opens the network overview/connection window

24
OLGA VERSION 5 Get Started Page 25

Network plot allows for a quasi-animated plotting of profiles in the Network view.

Configure: Allows for (re)configuration of e.g. colors and line interpolation.

3D View Changes to 3D view as described in section 5.2.3.

Show directions Direction arrows are displayed on each Flowpath.

5.2.2 Flow path view

The actual profile of the geometry may be viewed by opening the flow path; double click
FLOWPATH in the “Model View”. This opens a new tab in the Graphical Editor

25
OLGA VERSION 5 Get Started Page 26

showing the selected flow path only (including equipment). In the Flowpath view
equipment may be added by drag and drop from the “Components” window (the available
components are now the ones that is located on a specific Flowpath).

Focus an object by a left mouse click to bring up the Property editor, and the properties of
the object can be entered or modified.

Focus is shifted away from selected objects by pointing to the background while holding
down the Shift key.

26
OLGA VERSION 5 Get Started Page 27

Zooming in and out is done by the mouse wheel and moving the mouse while the left
mouse button is held down will move the layout within the window.

5.2.3 3-D view

Both the Network view and the Flowpath view are available in 3-D. Right click on the
view background and check 3D View in the menu. See Section 13.4. about moving
the "camera" position, moving the pipeline network and zooming in 3-D.

The Flowpath view will show the real pipeline profile. If the correct coordinates are
given for the nodes the network view will be correct. Otherwise a schematic view of
the network is transformed to 3D.

27
OLGA VERSION 5 Get Started Page 28

5.3 Model view

The Model View is used for navigation between the objects of the system. The
objects are ordered hierarchically with a Project on top comprising one or more
cases. A case contains Case Definitions, Libraries, Output, Network Connections and
Network Components.

• Case Definitions describe information common to the whole system simulated.


• Network Components describe the properties of the flow network (currently
either a node or a flow path).
• Libraries contain keywords that can be accessed globally (for instance Material
and Wall).
• Output contains global output definitions, such as plotting intervals for trend,
profile and output.
• FA-models contain input to flow assurance models.
• Compositional has input to the compositional model.

28
OLGA VERSION 5 Get Started Page 29

• Advanced thermal contains input to the FEMTherm and bundle models and
input to annulus calculations.

When selecting an object in the project explorer, the object is made active and its
properties may be edited in the “Properties” view.

The model view contains input for all cases in the project. Switching between the
different cases is done by clicking on the file name in model view.

5.4 File view


The “File View” shows the input files of the project.

By right clicking on the on a file the file can be removed or the input file on OLGA
2000 format can be opened in a text editor (applies to OLGA 2000 only).

29
OLGA VERSION 5 Get Started Page 30

5.5 Components view

Simulation objects may be fetched from the “Components” window by Drag & Drop
onto the Graphical Editor. Only objects available at the network level presented are
available. This means that e.g. process equipment can be introduced this way only
when the Flowpath is open.

30
OLGA VERSION 5 Get Started Page 31

5.6 Properties

The “Properties” window is a common interface to


all simulation objects (keywords). Here the objects
are defined setting values on the different keys.
The left column gives the property name (currently
the key name), the right its value.

Units may be altered as shown in the figure. By


default the value will update when the unit is
changed. To keep the value: Press the Shift key
while changing the unit.

When a property is selected, a description is


shown in the field at the bottom.

Values may be inserted by typing or by selecting


one or several values presented by the interface.

The colours of the keys have the following


meaning:
Black : Key can be given but not
required.
Red : Key required.
Grey : Key cannot be given.

Note that the colours will change as input is given.


As an example: Two keys are mutually exclusive
and one of them must be given. Both will then
initially be red (required). When a value is given for
one of the keys its colour will change to black (key
is given and no more input required for that key)
while the other key will turn grey (can not be
given).

Some keywords have a special property page to


make the process of entering data easier. These
property pages can be accessed through the
property editor button at the top bar of the property
editor window.

31
OLGA VERSION 5 Get Started Page 32

5.7 Output view


The output view (not to be confused with the OUTPUT keyword/OUTPUT File) gives
information about the state of the cases, modelling and simulations. The information
comes out three categories:

• Error messages (and task list) - : Cannot simulate


o Errors in input
o Errors from initialization phase
o Errors during simulation
o List of incomplete keywords.
o Click on the symbol to go to the incomplete keyword

• Warnings - : The simulation may still be performed 4

• Information -
o Simulator state changes
o Progress during simulation
o Any messages during simulation (info previously directed to DOS
window)

The windows can be cleared from the context menu (right click).

Text can be copied:


• Mark text
• Right click and copy

4
Warnings from the OLGA interpretation of fluid files which takes place when the simulation has started are
categorized as Information
32
OLGA VERSION 5 Get Started Page 33

Which Output categories are active are indicated by the "orange" background around the
category names in the top bar of the output window. A left mouse click on the text will
activate and deactivate.

By default the output from the active case is shown. Output from other cases is selected
from the pull-down menu at the top of the output window.

33
OLGA VERSION 5 Get Started Page 34

6. CASE DESIGN
All cases reside inside projects, and projects may hold one or several cases. Project
files have extension .opp, case files have extension .opi.

6.1 New project


A new project is defined by:

• Select File/New/Project
• Ctrl+Shift+N
• Click the New Case icon or New Project at the base of the Start Page.

When starting a new project a new folder can optionally be created by checking the
“Create folder” box.

6.2 New case


A new case is defined in one of the following ways:
• Select File/New/Case (you will be taken into a dialog to create a new project if
not already done)
• Ctrl+N
• Click the New Case icon

Then, the window below appears:

34
OLGA VERSION 5 Get Started Page 35

Enter a case name (or use default), fill inn location (or use default) and select
template.

• OLGA Case File. This generates an empty case.


• OLGA Basic Case. This generates a complete basic case. Ready for
simulation.
• OLGA Network case. This generates a complete basic case with an internal
merge node.

6.2.1 Build from empty template

A case containing the minimum required information is built as follows:

6.2.1.1 Case information

Complete the information of the following elements by right click on the case in the
Model view and selecting from the drop down menu:

CaseDefinition > CASE


CaseDefinition > FILES
CaseDefinition > INTEGRATION
CaseDefinition > OPTIONS

NOTE:

Software (e.g. PVTsim) for generation of fluid-files may be started from the GUI
through the Tools Menu. How to add programs to the Tools menu is described in
section 4.

6.2.1.2 Flowpath

Define a flowpath like this:

1. Drag two nodes from the component bar


2. Drag a Flowpath from the component bar.
3. Connect the nodes as described in section 5.2.1.
35
OLGA VERSION 5 Get Started Page 36

A default Geometry is introduced. Ref. Section 8 about the Geometry Editor for
modification of the Geometry,

6.2.1.3 Complete the defined objects

The defined simulation objects must now be completed. Information that needs to be
given can be found as follows:

1. Verify by
a. Press F7 or
b. right click on the case in the Model View and select Verify or
c. Click the Verify button in the Simulate toolbar
2. View the instructions presented in the task list in the Output window
3. Double click the task to open the relevant object in the “Properties”
4. Complete the fields marked red
5. View the instructions given in “Errors”.

Once enough information is given to the simulator, the state will change from Not
Runnable to Ready to Simulate.

Ready to simulate does not necessarily mean that the case is completely perfect for
OLGA. This is because the GUI itself does not perform any error checking5. This is
done by a version of the new generation simulator, OPUS (current working name).
There are some structural differences between OLGA and OPUS (OLGA is written in
FORTRAN and OPUS in C++) which may let incomplete specifications or wrong
definitions slip through.

A typical example: if you have specified heat transfer for the individual pipes in a
Flowpath (Branch) and then add a pipe without specifying heat transfer for that,
OPUS is not able to catch this. It will only be discovered when OLGA is checking the
input.

6.2.1.4 Changing a global label

In the new GUI the update of a modified object label is performed semi-automatically,
e.g. if you change a Wall label which has already been applied and you run verify,
you get an error message and a way to amend this as given below:

5
The reason is that when rules are changed in OPUS it will not be necessary to change them for the GUI as
well.
36
OLGA VERSION 5 Get Started Page 37

In the case outlined above the first 3 pipes and the 5th pipe have WALL-2. Now you
change the WALL-2 label to WALL-2B (for your own good reasons) and run Verify:

You now get the following error messages:

and the Properties window shows a "common key" where all instances of use of the
original key (WALL-2 in this case) are listed and checked, see below.

You can now change the WALL-2 to WALL-2B and run verify again:

37
OLGA VERSION 5 Get Started Page 38

The change of the WALL-label is now acknowledged (only the plotting specification
remains) as you also see from the PIPE-specifications, e.g. for PIPE-1:

6.2.1.5 Add new objects

New objects may be added in two ways:

• Right click on a FLOWPATH in the Model View and select from the appearing
groups
• Open the Flowpath view (double click on a FLOWPATH in the model view) and
drag & drop from the “Components”.

As new objects are introduced, the simulator state normally changes to Not
Runnable. Complete the definitions as described above.

6.2.1.6 Copy/Paste

By right clicking on an object in the model view it can be copied (alternatively by Ctrl-
C) and pasted at the desired location by right click and Paste (alternatively Ctrl-V).

38
OLGA VERSION 5 Get Started Page 39

Copy/Paste can also be performed directly in the canvas by pointing at an object,


right click and select copy, point to where the object is to be pasted and select past.

Currently multiple select can be used within a Flowpath, but multiple select can not
be used on Flowpaths.

6.2.1.7 Define output variables

Variables can be specified on two levels: On a case level and on a flowpath (branch)
level.

Output intervals (DTOUT and DTPLOT) are usually defined on the case level.

Global variables are specified on the case level. You may also specify variables
common to all branches, equipment and modules on the case level.

Output definitions are set up by right clicking on either case or FLOWPATH and
selecting Add/Output and then select the relevant output function:

This introduces a case Output-key which contains the output definitions on the case
level.

Click on Output, select the time-unit for DTOUT in the Properties and enter e.g. 2:

39
OLGA VERSION 5 Get Started Page 40

You may now add the DTPLOT for profiles, trends and OLGA-viewer by right-clicking
on Output (or on the case label) select ADD Æ e.g. PROFILE,

and then fill in the DTPLOT in the properties window for PROFILE
(do the same for TREND).

Now you specify plot-variables common to all branches in the case.

You may select the case-Output again and select e.g. PROFILEDATA.

40
OLGA VERSION 5 Get Started Page 41

Click in the VARIABLE field in the Properties window and then the - box.

Select variables from the window shown below. The variables may be sorted:

• Alphabetically (by name or description)


• Categorized (as seen below)
• Those already selected (click the check box)

The units for plotting variables can be changed when actually plotting, ref. Ch. 11.

41
OLGA VERSION 5 Get Started Page 42

All selected (alphabetic must be checked first)

When you check OK in the relevant variable selection window the variables appear in
the Properties window:

Now you can do the same with the global Trend-data.

To specify e.g. local trend data you right-click Flowpath and select ADD etc., as
illustrated below.

You check the variable select-box in the Properties window and make the selection:

You can now give the selection a label and save it. This can then be re-used at
several positions.

42
OLGA VERSION 5 Get Started Page 43

In the Properties window you specify where to plot the variables. When checking the
box in the PIPE entry you get into the pipe selection window where you select the
pipe(s) you want. Then you specify the section(s). Observe that you also get an
indication of the absolute position – relative to the start of the Flowpath.

You may now add another trend definition by right clicking on the FLOWPATH-Output
key: (you can also define it by right clicking the FLOWPATH):

When you get back to the "Select output variables" window, you can click on the
orange pull-down to re-use the "Rates".

43
OLGA VERSION 5 Get Started Page 44

By clicking OK you get back to the properties. You enter the pipe selection again and
complete the specification by giving the section(s), see below:

6.2.1.8 Activate OLGA Viewer

The OLGA Viewer is the stand-alone animation tool that is installed and defined as
an external tool by default, see the Tools – menu.

The PLOT-key is needed by the OLGA Viewer, and it is always specified on a case
level:

In the Properties window for the PLOT – key you specify both the plotting interval
DTPLOT and the variables. The variables are all plotted for all flow paths (branches)
and all sections of the case.

44
OLGA VERSION 5 Get Started Page 45

6.3 Open existing projects/cases


You may open an existing Project, an existing OLGA case or an existing OLGA 2000
case. If you open an existing case after you have opened or created a project the
case will be added to the project. However, if you open an existing case without
having a project, a project with the case name is created. You should save this
project immediately

6.3.1 Open project

Select either of these:


• Select File/Open/Project
• Ctrl+Shift+o

and open a file with extension .opp.

6.3.2 Open case

Select either of these:


• Select File/Open/Case
• Ctrl+o
• Click the Open Case icon

and open a file with extension .opi, .key or .inp.

45
OLGA VERSION 5 Get Started Page 46

7. INPUT EDITORS

7.1Time series editor


Input keys with time series can be edited in a time series editor. The time series
editor is accessed through the properties for the relevant keyword.

If there are several independent time-varying parameters within one keyword the
graph of these can be displayed by checking them in the graph legend (which shows
the minimum necessary input parameters).

46
OLGA VERSION 5 Get Started Page 47

You can insert columns in the spreadsheet by right-clicking on a column-header.

Selecting "cancel" nullifies all actions performed within the time series editor.

A trick: to fill in the same value for several time points: enter the value in the column
for the last time-point and then enter.

7.2 INITIALCONDITIONS and HEATTRANSFER


Special editors are available for editing initial conditions and heat transfer statements.
The input is graphically displayed together with the data. An example of an initial
condition is shown in some detail below. An example of heat transfer specification is
also given.

7.2.1 Initial conditions

You access these screens through the property editor button on the
INITIALCONDITION statements.

Note that these screens can only be used when entering data section-wise. However, by
selecting cells in the spreadsheet and right clicking, a number of interpolation options are
available. These will help input the desired data. Also, if incomplete data is given it will
automatically be completed when exiting the editor.

The procedure for entering INITIAL CONDITIONS could then be:


Set OPTIONS STEADY STATE= OFF
Add Initial conditions by right clicking on the relevant FLOWPATH:

47
OLGA VERSION 5 Get Started Page 48

The property window for Initial Conditions (IC) comes up similar to the left window
below:

In the IC Editor the default pressure unit is used and you cannot change it within the
IC Editor. You must do it in the Section-wise part of the window below. To make the
unit change active, you must also enter a pressure value.

To activate the IC Editor you click the property button on top, see below:

48
OLGA VERSION 5 Get Started Page 49

The IC Editor screen.

We see the profile of the pipeline (ref GEOM-A in next section) and the constant pressure
that was entered (50 bara).

To enter a realistic pressure profile left-click on the top of a column (selects all) and then
right click and then left click in Interpolate. The Interpolate window below comes up.
Select interpolation method and then Start/Stop values and OK. Now all sections are
filled in e.g.

49
OLGA VERSION 5 Get Started Page 50

Fill in Temperature, Void Fraction, Watercut and MassFlow in the same manner (or by
applying a mix of manual input and automatic interpolation). When finished, the Initial
Conditions Property windows would look like below:

50
OLGA VERSION 5 Get Started Page 51

7.2.2 Heat transfer

The heat transfer properties could look like below:

By clicking the properties icon of this window you enter the Heat Transfer Editor
(HT Editor).

51
OLGA VERSION 5 Get Started Page 52

The methods for manipulating the parameters are the same as for the Initial Conditions,
but here we shall illustrate how to enter two constant values for ambient temperature.

We assume that the temperature is changing from 6 to 4 C at the top of the first hill and
remains (sufficiently) constant at 4 C for the rest of the pipe distance. The first hill is at
about 25 km (X) and we can use the HT Editor to see in which PIPE that is (the X-column
to the left) namely at the end of PIPE-14 (i.e. beginning of PIPE-15).

52
OLGA VERSION 5 Get Started Page 53

Now you select all the pipes from PIPE-15 to the end by Left-clicking in the Tambient-
column for PIPE-15 and drag to the bottom.

Right click anywhere in the selected column and enter 4 C for start and stop-value, see
below:

You now see that the ambient temperature drops from 6 to 4 C on the first hill.

53
OLGA VERSION 5 Get Started Page 54

Click OK and the HT properties window is also updated.

54
OLGA VERSION 5 Get Started Page 55

8. GEOMETRY EDITOR

8.1Activating
Pipeline profiles are edited in the Geometry Editor. The tool can be started like this:

• Tools/Geometry Editor (opens with only default data) or


• Select the Property page for the active geometry (opens with data for the selected
geometry)

You may also select FLOWPATH (or GEOMETRY) in the Model-View and right click and
then select Properties:

55
OLGA VERSION 5 Get Started Page 56

You will now see this graph of the default geometry for the single branch template:

8.2 Enter a new profile


You can work with an existing profile in the .xy-format by File/Import and opening the
relevant xy-file with the browser (e.g. Profile-A.xy - this Geometry is given below).

56
OLGA VERSION 5 Get Started Page 57

You should save this new Geometry with a new label while in the Geometry Editor (e.g.
GEOM-A. The saved geometry file has the extension .geo:

You must also give the new Geometry relevant sections, diameters, roughness and walls.
How to do this is described below.

You can also copy directly from an Excel –worksheet:


Open the Geometry Editor and select FileÆ New. You will get a new Geometry with one
pipe and default values as given below. The geometry is now presented in a tabular
format and you can toggle between this and the graphic format by clicking on the relevant
tab.

Open the Excel-file with your profile-data, select the X-Y columns and copy.

Select the Start Point 0, 0 in the Geometry Editor with the default geometry open and then
Paste. You will get the question below. Answer yes and the data will be pasted directly
over to your open geometry.

57
OLGA VERSION 5 Get Started Page 58

Please observe that if your excel geometry contains fewer pipes than the one you
paste over, you must delete the obsolete pipes.
You can now save this Geometry (e.g. GEOM-B) and use it for one or several
Flowpaths in any model. First you must of course complete it with sections, diameters
etc., as you do in the window below.

8.3 Edit Geometries


When opening the Geometry Editor you have seen that two views are available i.e.
the graph of the profile and a table of pipes. The two windows can be viewed
simultaneously by selecting the e.g. plot tab and drag it towards the bottom of the
window (as has been done below).

58
OLGA VERSION 5 Get Started Page 59

8.3.1 Edit the table

New pipes are added, renamed or deleted, by right-clicking in the Pipe column and
selecting the relevant action.

X and Y in the table give the data for the end point of the pipe. Changing Length-
Elevation affects X-Y and vice-versa6.

Units are changed by right clicking in the title cell (e.g. “Diameter [m]”) and selecting a
unit.

8.3.2 Edit the graph

You can also edit the Geometry by the following actions under the Actions menu:

Normal (no change)


A: Add a point
M: Move a point
D: Delete a point

6
There is a bug in OLGA v5.0. Entering X-values instead of Length should eliminate the problem.
59
OLGA VERSION 5 Get Started Page 60

Restrictions on the graphic editor can be imposed (Actions -> Restrictions):

X Fixed (X remains fixed, Y can be changed)


X Bound (Point X-value can not be moved upstream or downstream neighbors)
Y Fixed (Y remains fixed, X can be changed)
Y Bound (Point Y-value can not be moved above or below neighbors)
Recursive (all points downstream will follow the point that is being moved)

8.3.3 Check angle distribution

You can check the angel distribution of a Geometry by selecting Tools -> Check
angle distribution. You can see the angle groups that are used by right clicking when
in the output window from the angle distribution calculation. You can also change the
angel groups.

The color of the bars and the % values in the output window indicate the difference
between the average angle of the pipes within a group and the mean value of the
angle group. Green (and a low % deviation) means a good relevance of the angle
group. The % value is a numerically calculated standard deviation divided by half of
the angle group span.

8.3.4 Filter the data

Select Tools/Filter. You have two options: a Box filter or a preservation of angle
distribution / total flowpath length (the algorithm is identical to the one used in the
OLGA 2000 Grid Generator).

Box filter: This filter is more relevant for removing relatively small disturbances from
a pipeline survey. Enter the horizontal sample distance and the vertical sample
height. These values define a moving rectangle (a box) within which all data points
will be filtered out. The filtered data appear as a new geometry which may be further
filtered/edited.

Angel distribution: Enter the maximum pipe length that shall be used to filter the
profile while maintaining the angle distribution and the total pipe length.

When filtering has been completed it is a good idea to compare the angle
distributions of the original geometry and the filtered ones. The filter with the best
reproduction of the original geometry should be used – keeping in mind that the angel
groups should be representative.

60
OLGA VERSION 5 Get Started Page 61

8.3.5 Complete the data

You may want to open the e.g. GEOM-A.geo file.

All fields except the “Length of sections” are editable directly, and copy/paste may be
used for single cells. The "Length of sections" has its own input support-tools

In contrast to OLGA2000 all Pipes must have a Diameter, a Roughness and a Wall (if
relevant). You can use copy-paste functions to achieve this.

If defined in the OLGA case, walls may be selected from the drop down menu.
Within the Graph window the profile may be edited activating either of the four menu
functions (found under Actions -> Graphical):

8.3.6 Define sectioning

The pipe sectioning can be performed in two ways:

1. Manually enter number of sections in the “# Sections” column. This gives you
equally long sections for a given pipe.

2. If you double click in the Length of Section list you enter a tool to distribute
sections of various lengths over the pipe-length.

Change (the nominal) no of sections to 3 and enter 4.75 m in Section 1 and click OK.

61
OLGA VERSION 5 Get Started Page 62

You get 2 sections of 4.75 m and 1 of 4.64214 m.

The main rule is that the tool ensures that you get a sum of sections which is equal to
the pipe length. Moreover, open section lengths mean that you repeat the value
above.

The "remaining of total" is the total pipe length minus length accumulated over the
section lengths specified (including the open ones).

If you double-click in the Length of Sections field again:

62
OLGA VERSION 5 Get Started Page 63

You get the window below and you see that the remaining now is very close to zero.

To start over again you can set # of sections to 0.

3. Use the discretization tool (Tools/Discretize). Then all pipes are given the same
selected number of sections.

8.3.7 Use the new geometry

A new geometry may be imported to a case as follows:


Open the geometry files you want to use (you can open them from the Geometry
editor or in explorer). Right click on FLOWPATH or Piping in the Model View, select
“Exchange Geometry” and pick the desired geometry. If you use the same Geometry
file for several branches you must re-label the Geometries afterwards to secure that
the labels are genuine.

You can also exchange geometries between flow paths in the same case. Select the
flow path and its Property Page of the Geometry you want to distribute to other flow
paths. Then you select the flow paths that you want to import to and select Exchange
Geometry:

Select FLOWPATH and click on Properties. This opens the Geometry GEOM-1_2

Select destination FLOWPATH and click on Exchange Geometries and then on


GEOM-1_2.

63
OLGA VERSION 5 Get Started Page 64

64
OLGA VERSION 5 Get Started Page 65

8.3.8 Menus

The Geometry Editor features the following menus:

File
New New geometry
Import Import xy-data
Open Open geometry file (*.geo)
Close Close geometry
Save Save geometry
Save As Save geometry as new file
Print Print active window
Print Preview
Print Setup
<Recent File>
Send
Exit
Edit
Undo
Cut
Copy
Paste
Configure Configure graph window
View
Global Overview
Standard
Restrictions
Graph
Status Bar
Labels
Walls
Actions
Graphical Normal/Add/Move/Delete
Restrictions X Fixed/X Bound/Y Fixed/Y Bound/Recursive
Tools
Angle groups
Check Angle Distribution
Check section lengths calculate the length ratio of adjoining sections.
Discretize Automatic pipe sectioning (all equal)
Filter Filter data
Reset Pipe Labels Use default pipe labeling
Reverse geometry Creates a geometry that is the mirror image of the
original geometry (in x-direction).
Window
New window New window with active data (works on same data set)
New window Select graph or table representation
New Horizontal Tab Group
New Vertical Tab Group
More Windows
Help
Help Topics Not implemented
About Geometry Version Information

65
OLGA VERSION 5 Get Started Page 66

8.4 Limitations
The following important limitation applies:

1. For export to Excel, dot (“.”) must be selected as decimal separator for Excel

66
OLGA VERSION 5 Get Started Page 67

9. PARAMETRIC STUDY
Parametric studies are defined through Tools-Studies, where new studies can be
added or previously performed studies reopened.

The input screen for parametric studies is shown below.

The number of parameters is given in the field labelled “#Parameters”.

At present studies can only be performed on the local machine, but the number of
simultaneous simulation can be given (#Parallel simulations). This can be useful for
machines with multiple processors or multithreading.

67
OLGA VERSION 5 Get Started Page 68

The quick way to enter an equidistant parameter variation is given below:

Right-click in MASSFLOW below and select Set Value(s)

68
OLGA VERSION 5 Get Started Page 69

Set the e.g. the values below:

This results in the definition of 4 cases ready for running. You may save the study by
clicking OK. The study is saved in a separate folder together with the Project/Case.

Click Run Study and observe the progress:

69
OLGA VERSION 5 Get Started Page 70

When finished select e.g. Trend Plot:

70
OLGA VERSION 5 Get Started Page 71

Select variables for plotting e.g. QLT at PIPE-86 (outlet total liquid flow):

Change units and then plot.

71
OLGA VERSION 5 Get Started Page 72

More details on plotting are given in Ch. 11 and for more details on Matrix.. and XY-
Plot see Tutorial (accessed from the Help menu in GUI).

Set up a study with non-equidistant parameter values:

Add a new study and right click on the Case column to add new entries.

Now follow the same procedure as above:

Right click on the column with (<Right click to select parameter>), select Source
and then Massflow.

Enter one value for mass flow for each case and press Run Study. When cases are
finished you can plot to see the results.

72
OLGA VERSION 5 Get Started Page 73

10. SIMULATION
Simulation (batch) is controlled by the simulation menu. Press “Run simulation” for
starting a simulation. Progress is visualized in the output window and on the
progress-bar in the lower right-hand corner.

73
OLGA VERSION 5 Get Started Page 74

11. VIEW YOUR RESULTS


Trend and profile plot output as defined by the user can be viewed during and after
simulation. The plotting buttons on the top menu will show red lines when plot files
are available for the active case.

Trend Profile PVT File

11.1 Active case trend plot


Select trend plot with the buttons in the top menu. Trend plot gives you the menu
below. Select the variables you want to plot. Double click on the selection or right
click and chose one of the options displayed. Click OK to see the graph.

NOTE:
For network cases (more than one flow path) the results are stored in separate files for each
flow path using the following naming convention (OLGA 2000 will save all results in one file)
<Input file name><Flowpath label>.tpl or .ppl
Example: MyCaseP1.ppl gives the profile plot data for flow path P1 when running
MyCase.opi.

74
OLGA VERSION 5 Get Started Page 75

The default time unit for a Trend plot is Seconds which you change at the lower left.

75
OLGA VERSION 5 Get Started Page 76

11.2Active case profile plot


You select the profile button and then select variable (s) to plot:

Trend Profile PVT File

76
OLGA VERSION 5 Get Started Page 77

You may now "play-back" the profile plot, either by dragging the slide or by clicking the
green triangle. You may also freeze a curve by clicking the "needle" button.

You get a frozen curve each time you click it. You "un-freeze" by disable the needle.
The play-back is stopped by clicking the blue square. You may play-back several profiles
simultaneously, but the speed will of course depend on your PC-capacity.

77
OLGA VERSION 5 Get Started Page 78

11.3 Some general features of the plotting tool


The plotting tool is a quite sophisticated program and you have access to several
functions for modifying your graph7.

• Add/remove data to plot:


o Right click and select Dataset/Select or
o Menu Options/Select Plot Variables
• View values: Right click and select Track values
• For profile plots: select plot time point with slider at bottom right
• Collapse/expand axes: Right click and select
o Axes/Collapse all or
o Axes/Expand all
• Display legend: Right click and select Show legend
• Modify settings
o Right click and select Configuration (window as below) or
o Menu Options/Configuration
• Zoom:
o Select upper left corner with left mouse button
o Drag to lower right corner while holding button
o Release
• Un-zoom: Do as for zoom, but drag to the left (any start and end point works)
• Zoom in/zoom out/un-zoom buttons are also available

11.4 Export/import data to/from MS Excel


• Export data: Right click and select Dataset/Copy Data. Then paste into MS
Excel.
• Paste from Excel: Select data columns in and select copy. In Plot window right
click and select Dataset->Paste. See some examples below.

Trend:

7
You may also change default colors, text styles etc.
78
OLGA VERSION 5 Get Started Page 79

All the variables in the graph are copied to separate columns in the Excel-worksheet –
each variable with the X-axis.

Profile

Copy to Excel by right-click in the graph and then as illustrated below:

79
OLGA VERSION 5 Get Started Page 80

11.5 Multi-case plotting


It is possible to plot results from several cases/projects simultaneously. For example
you can plot data from all the cases in your project, the in-active as well as the one
active. You can open several results files by the ToolsÆ Plot menu (select several
files, either trend (.tlp) or profile (.plt) or from within the plot tool itself by adding files,
see below. You plot as for single cases.

80
OLGA VERSION 5 Get Started Page 81

Note that for profile plots where different plotting intervals have been used in the different
files the profile closest to the selected time will be used and no interpolation is currently
applied.

The figure above gives total liquid hold-up at time = 0 for 2 different mass flow rates:
40 kg/s (blue) and 80 kg/s.

81
OLGA VERSION 5 Get Started Page 82

11.6 Fluid properties


You can use the plot-tool to plot fluid-properties. Select Tools-Plot and then open a fluid-
properties file (.tab). You then select the property or properties you want to see and
proceed as usual.

You may use the freeze-function as for profile plots. You click the nail and then the green
triangle. You repeat clicking the nail to freeze more curves.

The default x-axis is temperature. You can change this by moving the column header
fields in the right-hand side window to locate the "X-Axis" field (which is in the far right
position by default) and select Pressure instead of Temperature.

82
OLGA VERSION 5 Get Started Page 83

11.7 OLGA Viewer


The OLGA viewer is activated from the Tools-menu from the list of external tools.
You must open the appropriate .plt – file.

The figure shows a snap-shot from the OLGA viewer

11.8 Menus
File
Reload
Save Save chart configuration (tee) with link to data file
(tpl/ppl)
Print
Print Preview
Close
Options
Configuration Configure plot (Chart and Series display options)
Select Plot Variables Select data to be plotted
Help
About Not activated

83
OLGA VERSION 5 Get Started Page 84

11.9 Reports
A case report can be generated within WINDOWS Explorer from Tools Æ Report.
This is the first version of pre-defined report format and has a limited content. This
will be expanded in future versions. Since it has a java script, you must accept the
security warning you get in Windows Explorer, before the functions in the report is
activated.

Use the yellow labels to browse the report or check "Printer Friendly version” and you
remove the menu system.

84
OLGA VERSION 5 Get Started Page 85

12. ONLINE HELP


OLGA is equipped with on-line help documentation which can be opened directly
from the user interface. The help can be reached in several ways:

• Click the Properties view and press F1 -> leads to the information on the
relevant model
• Select Help/Help topics from the main menu

The on-line help has the standard features:

• Contents
• Index
• Search

The information in the current version is a minimum:

• Reference manual on models and properties


• Available output variables
• Unit conversion factors
• OLGA has the information from Get Started

The documentation will be extended.

85
OLGA VERSION 5 Get Started Page 86

13. GENERAL WINDOW OPERATIONS

13.1 Moving windows


Windows may be hidden and re-opened through the view menu. They may be
detached from the frame (floating) and may be docked again by moving the window
to the border of the frame. Double click on a floating window to move it back to the
last docked position.

In the picture below the blue area indicates where the window will end up if dropped
at the current location. If the cursor is moved over one of the arrows towards the
edge of the screen the window will dock on the corresponding border of the frame. If
dropped on one of the four arrows in the centre of the screen the window will dock
towards the corresponding side of the frame of the pipeline schematic window.

Double clicking on the top bar of a docked window makes it float and double clicking
on the top bar of a floating window makes it dock.

13.2 Moving objects inside graphical editor


1. Click on object
2. Click square handle and move in plane
3. Click on arrow and move along axis

13.3 Hot keys


Ctrl+z Undo
z Enable zoom in graphical editor; mark area with mouse
Left shift+z Enable un-zoom in graphical editor; mark area with mouse
Mouse wheel Zoom in or out in graphical editor
Delete Deletes object

86
OLGA VERSION 5 Get Started Page 87

13.4 Moving view in 3D


The following illustration shows how to navigate the camera in fly mode. In Orbit
Mode left mouse button + moving the mouse will make the camera orbit around the
pivot point. If you release the left mouse button you can use the key combinations to
move around.

Camera manoeuvring:
• Mouse wheel Zoom in/out
• Arrows Move camera in/out/left/right
• Right shift Move up
• Left shift Move down (or: Insert move down)

Left mouse button No selection: Rotate camera


Network selected: Rotate network (see below)

Camera Movement Speed


Slow to Fast Keys 1 – 9

Rotate/Move/Scale
Rotate Select object + key R + left mouse button + move mouse
Move Select object + key M + left mouse button + move mouse
Scale Select object + key S + left mouse button + move mouse

Scene View Shortcuts


Fly Mode Key F
Orbit Mode Key O (recommended to get best overview)
Field of View Mouse wheel, or
key Z + left mouse button + mark area, or
key Z + left mouse click (zoom in)’
Left Shift + key Z + left mouse click (zoom out)
Space Deselect interaction mode
Escape Deselect objects
Q (in 2D View) Zoom to extent
Delete [Del] Delete selected object.

87
OLGA VERSION 5 Get Started Page 88

14. MENUS

14.1 File
New > Project… Create new project
New > Case… Create new case
Open > Project… Open project
Open > Case… Open case
Save Case Save case
Save Case As… Save a new case
Duplicate Case… Makes a copy of the selected case
Save Project Save project
Close Project Close (and save) project
Print… Disabled
Print Preview Disabled
Print setup…
Recent projects List of projects recently opened
Recent cases List of cases recently opened
Exit Exit OPUS

14.2 Edit
Standard windows commands

Undo
Redo
Cut Disabled
Copy
Paste
Paste special… Disabled

14.3 View
Select what windows and toolbars to be visible.

88
OLGA VERSION 5 Get Started Page 89

14.4 Project
Add New Item… Same as New Case
Add Existing Item… Open an existing file e.g. an .opi file
Project Dependencies
Close Project

14.5 Simulation
Run Start simulation (Start simulation in batch-
messages from simulation are sent to the Output
window)
Stop Stop simulation. Returns to initial state
Pause Pause simulation. Simulation may be resumed
(Not implemented for OLGA).
Run Project Start to run all cases in a project in a given order
Run Batch Start simulation in a DOS-control window.
Run Project Batch Start to run all cases in a project in a DOS-control
window
Verify Verify input

14.6 Tools
The tools available are listed below.

14.7 Windows
Standard windows operations.

14.8 Help
Help topics Online documentation
Getting started Opens pdf file with getting started document.
About Release information

89
OLGA VERSION 5 Get Started Page 90

15.TOOL BARS

15.1 Standard

New case
Open case
Save Saves Case
Save Project
Cut Disabled
Copy
Paste
Undo
Redo
Print Disabled
About
Help
Model view
Property editor
Components
File view
Output

15.2 Simulate

Run Start simulation


Stop Stop simulation. Returns to initial state.
Pause Disabled
Run batch Run batch in DOS window
Verify Verify case

15.3 Plot

Plot current trend plot


Plot current profile plot
Plot current PVT file
View current Output File
15.4 Layout

Fit window
Move Moves a graphic object
Scale Scales an object
Rotate Rotates an object
90
OLGA VERSION 5 Get Started Page 91

Circular For systems with defined


Grid Nodes placed in grid
Hierarchical type 1 Hierarchy
Hierarchical type 2 Hierarchy
Radial For systems with defined center
2D Modify 2-dimensional layout (schematic view)
3D Modify 3-dimensional layout
23 Modify both views
V Layout algorithm direction is vertical.
H Layout algorithm direction is horizontal.

91

You might also like