E-TRAN - Translator for Power System Simulation Programs - Version: 5.2.0.

10, March
24, 2021
Electranix Corporation

Date: Mon Dec 19 09:14:08 2022

PSCAD case file name: C:\Users\2526396268\Desktop\savnw\savnw_PSCAD.pscx

--- Reading PSSE input file: C:\Users\2526396268\Desktop\savnw\savnw.raw

- Reading Case ID Data...

- Reading System Wide Data...

- Reading Bus Data...

- Reading Load Data...

- Reading Fixed Shunt Data...

- Reading Generator Data...

- Reading Branch Data...

- Reading System Switching Device Data...

- Reading Transformer Data Data...

- Reading Area Data...

- Reading 2 Terminal DC Data...

- Reading VSC Data...

- Reading Impedance Correction Data...

- Reading Multi-Terminal DC Data...

- Reading Multi-Section Line Data...

Warning: Multi-Section Line Grouping Data Ignored!

- Reading Zone Data...

- Reading Inter-Area Data...

Warning: Inter-Area Transfer Data Ignored!

- Reading Owner Data...

Warning: Owner Data Ignored!

- Reading FACTS Data...

- Reading Switched Shunt Data...

- Reading GNE Device Data...


- Reading Induction Machine Data...

- End of Reading Data...


Q Record read, rest of file will be ignored.
Read routine exiting normally.
PSSE Summary
PSSE Busses: 23
PSSE Generators: 6
PSSE Loads: 8
PSSE Branches: 34
PSSE Transmission Lines: 23
PSSE Transformers: 11
PSSE DC Terminals: 0
PSSE Switched Shunt Branches: 0
PSSE Fixed Shunt Branches: 5
PSSE System Switching Devices: 0

Creating subsystems, busses etc...

Initial Indexing of branches and busses...

Subsystem Creation Complete.

--- Reading PSSE .seq input file: C:\Users\2526396268\Desktop\savnw\savnw.seq

Warning: Reading .seq Generator Sequence data: Bus number=101, ID=1 - negative
sequence machine impedance not supported and is ignored...

Warning: Reading .seq Generator Sequence data: Bus number=102, ID=1 - negative
sequence machine impedance not supported and is ignored...

Warning: Reading .seq Generator Sequence data: Bus number=206, ID=1 - negative
sequence machine impedance not supported and is ignored...

Warning: Reading .seq Generator Sequence data: Bus number=211, ID=1 - negative
sequence machine impedance not supported and is ignored...

Warning: Reading .seq Generator Sequence data: Bus number=3011, ID=1 - negative
sequence machine impedance not supported and is ignored...

Warning: Reading .seq Generator Sequence data: Bus number=3018, ID=1 - negative
sequence machine impedance not supported and is ignored...

Warning: Reading .seq Mutual Impedance data: FR1=151, TO1=152, CKT1=1, FR2=151,
TO2=152, CKT2=2 - data not supported and is ignored...

Warning: Reading .seq Mutual Impedance data: FR1=153, TO1=154, CKT1=1, FR2=153,
TO2=154, CKT2=2 - data not supported and is ignored...

Warning: Reading .seq Mutual Impedance data: FR1=203, TO1=205, CKT1=1, FR2=203,
TO2=205, CKT2=2 - data not supported and is ignored...

Warning: Reading .seq Mutual Impedance data: FR1=3003, TO1=3005, CKT1=1, FR2=3003,
TO2=3005, CKT2=2 - data not supported and is ignored...

Warning: Reading .seq Mutual Impedance data: FR1=154, TO1=203, CKT1=1, FR2=203,
TO2=205, CKT2=1 - data not supported and is ignored...

Warning: Reading .seq Mutual Impedance data: FR1=154, TO1=203, CKT1=1, FR2=203,
TO2=205, CKT2=2 - data not supported and is ignored...

Warning: Reading .seq Transformer Zero data: FR=151, TO=101, TERT=0, CKT=1 - data
not supported and is ignored...

Warning: Reading .seq Transformer Zero data: FR=151, TO=102, TERT=0, CKT=1 - data
not supported and is ignored...

Warning: Reading .seq Transformer Zero data: FR=152, TO=153, TERT=0, CKT=1 - data
not supported and is ignored...

Warning: Reading .seq Transformer Zero data: FR=201, TO=211, TERT=0, CKT=1 - data
not supported and is ignored...

Warning: Reading .seq Transformer Zero data: FR=202, TO=203, TERT=0, CKT=1 - data
not supported and is ignored...

Warning: Reading .seq Transformer Zero data: FR=204, TO=205, TERT=0, CKT=1 - data
not supported and is ignored...

Warning: Reading .seq Transformer Zero data: FR=205, TO=206, TERT=0, CKT=1 - data
not supported and is ignored...

Warning: Reading .seq Transformer Zero data: FR=3001, TO=3002, TERT=0, CKT=1 - data
not supported and is ignored...

Warning: Reading .seq Transformer Zero data: FR=3001, TO=3011, TERT=0, CKT=1 - data
not supported and is ignored...

Warning: Reading .seq Transformer Zero data: FR=3004, TO=3005, TERT=0, CKT=1 - data
not supported and is ignored...

Warning: Reading .seq Transformer Zero data: FR=3008, TO=3018, TERT=0, CKT=1 - data
not supported and is ignored...

Selecting the Kept Network...

Network Equivalent: 9 busses have been identified to be kept in the network...

Initializing Y Matrix...

Checking for Ideal Branches in the Equivalent...

Busses Converted in Detail:


3011 3002 3001 3004 3003 3005 3006 3008 3018

Calling BuildY for loadflow verification.

Collapsing Ideal Branches...

--- Resetting node numbers after collapsing ideal branches

--- Resetting node collapsing indices after collapsing ideal branches

Finished collapsing ideal branches


Calling Verify_Orig_Loadflow.

Verifying Load Flow is Solved...

Forming voltage vector...

Forming current vector...

Removing generator currents from current vector...

--- Forming PQ vector...

Compute P,Q...

Checking V, I, PQ values...

The 23 busses with the largest PQ mis-match (p.u. on base MVA = 100) are:
Bus: 152, (P,Q) = (0.000157274,-0.00195578)
Bus: 205, (P,Q) = (-8.71229e-005,0.00185162)
Bus: 3001, (P,Q) = (-7.35888e-005,-0.00177126)
Bus: 154, (P,Q) = (0.00013702,-0.00169445)
Bus: 153, (P,Q) = (2.17681e-005,0.00157604)
Bus: 3003, (P,Q) = (2.66434e-005,0.00117463)
Bus: 202, (P,Q) = (-4.29031e-005,0.00103113)
Bus: 3005, (P,Q) = (8.88689e-005,0.000811709)
Bus: 151, (P,Q) = (-6.57192e-005,0.000648106)
Bus: 203, (P,Q) = (-8.1721e-005,-0.000558322)
Bus: 211, (P,Q) = (2.73229e-005,-0.000506852)
Bus: 3011, (P,Q) = (7.04901e-005,0.000437153)
Bus: 3006, (P,Q) = (-8.68253e-005,-0.000415474)
Bus: 3008, (P,Q) = (3.83638e-006,-0.000306338)
Bus: 3007, (P,Q) = (2.81125e-006,-0.000276732)
Bus: 201, (P,Q) = (-7.59622e-005,0.00019913)
Bus: 3004, (P,Q) = (-0.000121051,-0.000170679)
Bus: 206, (P,Q) = (0.00010176,0.000159878)
Bus: 3002, (P,Q) = (2.78579e-006,0.000177194)
Bus: 102, (P,Q) = (4.02572e-005,-0.000145044)
Bus: 101, (P,Q) = (4.02572e-005,-0.000145044)
Bus: 204, (P,Q) = (-5.91337e-005,-8.583e-005)
Bus: 3018, (P,Q) = (-1.45001e-005,6.38084e-005)

- If you see PQ which is greater than the load flow tolerance (usually 0.001 pu),
then this loadflow may not be not solved!
Notes:
- You may see a large +ve mismatch and an equally large -ve mismatch
at each end of a branch which has very small impedances (but is not ideal).
- This is because bus angles are usually only available to 6 decimal points in the
.raw file,
so branches entered with very small impedances (but not ideal) can have large
PQ mismatches at each end of the branch (the sum should be within tolerance
however).
- Consider converting these small impedances branches to ideal branches...

--- Clearing V,I and PQ vectors...


--- Loadflow verification complete!

Calling BuildY to form system equivalent.

Collapsing Ideal Branches...

--- Resetting node numbers after collapsing ideal branches

--- Resetting node collapsing indices after collapsing ideal branches

Finished collapsing ideal branches

Calling Reduce_Y.

Reducing Complete Y Matrix to Equivalent Nodes...

Yreduced (Y of complete system reduced to kept nodes)


(2.81486,-128.508) (0,0) (-1.9992,99.96) (0,0) (0,0) (0,0) (0,0) (0,0)
(0,0)
(0,0) (3.36532,-84.8877) (-1.3328,66.64) (-2.03252,18.2927) (0,0) (0,0)
(0,0) (0,0) (0,0)
(-1.9992,99.96) (-1.3328,66.64) (3.332,-291.6) (0,0) (-0,125) (0,0) (0,0)
(0,0) (0,0)
(0,0) (-2.03252,18.2927) (0,0) (6.09139,-103.673) (0,0) (-1.51388,61.5012)
(-0.432605,12.8735) (0.234928,3.69857) (0,0)
(0,0) (0,0) (-0,125) (0,0) (4.06504,-161.495) (-4.06504,36.5854) (0,0)
(0,0) (0,0)
(0,0) (0,0) (0,0) (-1.51388,61.5012) (-4.06504,36.5854) (15.6846,-170.893)
(-3.83667,32.8857) (-4.20521,39.2342) (0,0)
(0,0) (0,0) (0,0) (-0.432605,12.8735) (0,0) (-3.83667,32.8857) (8.63992,-
72.6839) (0.624814,9.14063) (0,0)
(0,0) (0,0) (0,0) (0.234928,3.69857) (0,0) (-4.20521,39.2342)
(0.624814,9.14063) (13.1578,-81.4679) (-0.0290656,11.7646)
(0,0) (0,0) (0,0) (0,0) (0,0) (0,0) (0,0) (-0.0290656,11.7646)
(0.135101,-15.4759)

Calling BuildY for kept system.

Collapsing Ideal Branches...

--- Resetting node numbers after collapsing ideal branches

--- Resetting node collapsing indices after collapsing ideal branches

Finished collapsing ideal branches

Ykeptfull (Y of kept system with ideal branches collapsed)


(2.81486,-128.508) (0,0) (-1.9992,99.96) (0,0) (0,0) (0,0) (0,0) (0,0)
(0,0)
(0,0) (3.36532,-84.8877) (-1.3328,66.64) (-2.03252,18.2927) (0,0) (0,0)
(0,0) (0,0) (0,0)
(-1.9992,99.96) (-1.3328,66.64) (3.332,-291.6) (0,0) (-0,125) (0,0) (0,0)
(0,0) (0,0)
(0,0) (-2.03252,18.2927) (0,0) (3.5464,-79.7489) (0,0) (-1.51388,61.5012)
(0,0) (0,0) (0,0)
(0,0) (0,0) (-0,125) (0,0) (4.06504,-161.495) (-4.06504,36.5854) (0,0)
(0,0) (0,0)
(0,0) (0,0) (0,0) (-1.51388,61.5012) (-4.06504,36.5854) (12.792,-151.009)
(-3.83667,32.8857) (-2.36593,19.7161) (0,0)
(0,0) (0,0) (0,0) (0,0) (0,0) (-3.83667,32.8857) (3.83667,-32.8507) (0,0)
(0,0)
(0,0) (0,0) (0,0) (0,0) (0,0) (-2.36593,19.7161) (0,0) (4.57143,-32.2369)
(-0.0290656,11.7646)
(0,0) (0,0) (0,0) (0,0) (0,0) (0,0) (0,0) (-0.0290656,11.7646)
(0.135101,-15.4759)

Negative R were found in the network equivalent off-diagonals

Negative R were set to 0 (as per the advanced circuit options specified)...

Yeq (Y of network equivalent system (Yeq=Yreduced-Ykept))


(0,0) (0,0) (0,0) (0,0) (0,0) (0,0) (0,0) (0,0) (0,0)
(0,0) (0,0) (0,0) (0,0) (0,0) (0,0) (0,0) (0,0) (0,0)
(0,0) (0,0) (0,0) (0,0) (0,0) (0,0) (0,0) (0,0) (0,0)
(0,0) (0,0) (0,0) (2.77993,-23.924) (0,0) (0,0) (-0.432605,12.8735)
(0,3.69857) (0,0)
(0,0) (0,0) (0,0) (0,0) (0,0) (0,0) (0,0) (0,0) (0,0)
(0,0) (0,0) (0,0) (0,0) (0,0) (2.89258,-19.8841) (0,0) (-1.83928,19.5181)
(0,0)
(0,0) (0,0) (0,0) (-0.432605,12.8735) (0,0) (0,0) (5.42807,-39.8332)
(0,9.14063) (0,0)
(0,0) (0,0) (0,0) (0,3.69857) (0,0) (-1.83928,19.5181) (0,9.14063)
(9.44615,-49.2311) (0,0)
(0,0) (0,0) (0,0) (0,0) (0,0) (0,0) (0,0) (0,0) (0,0)

Calling Generate_Circuit_From_Equivalent.

Forming System Equivalent...

Calling Reduce_Ykept.

Reducing Y Matrix of kept PSCAD network to Equivalent Nodes...

YKeptEQ (Y of PSCAD kept system reduced to boundary busses)


(2.45698,-72.6406) (-2.20669,67.7903) (0,0) (0,0)
(-2.20669,67.7903) (9.85951,-130.369) (-3.83667,32.8857) (-2.36593,19.7161)
(0,0) (-3.83667,32.8857) (3.83667,-32.8507) (0,0)
(0,0) (-2.36593,19.7161) (0,0) (4.60531,-23.2939)

Network Equivalent Boundary Busses:


Number of boundary busses is 4
3004, 3005, 3006, 3008

Busses Fully Modeled in PSCAD:


Number of busses fully modeled in PSCAD is 5
3001, 3002, 3003, 3011, 3018

Splitting large pages into sub-pages...

2 Subsystems left after ordering and splitting of large pages.


Writing PSCAD Output

Reading PSSE Dynamics input file: C:\Users\2526396268\Desktop\savnw\savnw.dyr

Warning during reading of .dyr file:


Generator at Bus 3018 Circuit: 1
The generator loadflow data controls the voltage at remote bus: 3008
but a compensation model has not been entered for the machine exciter...
E-TRAN will set the exciter VRef to the machine terminal voltage as per the
loadflow.

Summary of all Machines read from .dyr transient stability database and
translated into PSCAD:
BusName BasekV Bus # Ckt Machine Exciter
Governor Stabilizer Other
MINE_G 13.8 3011 1 GENROU SEXS
- -
CATDOG_G 13.8 3018 1 GENROU SEXS
- -

Calculating Branch PQ for substitution library...

Substituting initial condition info...

The following data was replaced using the Substitution Library: C:\Program Files
(x86)\PSCAD46\master.pslx

PSCAD output has been written to C:\Users\2526396268\Desktop\savnw\


savnw_PSCAD.pscx.

** E-TRAN Solution Engine Ending...

Elapsed Time in Solution Engine: 0:00:01 (hours:minutes:seconds)

Hybrid Python Script Output File C:\Users\2526396268\Desktop\savnw\hybrid_cfg.py


written.