Bulletin 77C01A02-01EN
For swithchboard mounting...
Power and
Energy Meter PR720
As a power equipment meter
As an energy savings monitor
UPM100/UPM101
As an energy savings monitor
Install without
disconnecting existing equipment
Clamp-on Current Transformers
CTW
The sales area of PR720/UPM100/CTW is limited,
please contact your nearest Yokogawa’s sales office or sales representative.
920 MHz wireless communication model of UPM100 is for Korean market only.
Reading
meter PR720 panel-mount monitor for power equipment Powerful support for
real time monitoring,
analog me erload check ol meter r analysis, reports, and
PR720 izes te Ov patr ea
ral ce demand monitoring of
u
t
rin
din
Cen
Red
power data.
g
g
equipment equipment management Data Logging Software
costs maintenance labor saving
GA10
VJET
Ethernet
VJET
Print reports
VJET
Pump, fan, freezer Manufacturing equipment/line A/C, lighting, outlets Elevators, OA equipment
PR720 panel-mount
power monitor
UPM100 UPM100 UPM100 PR720
RS-485
UPM100/UPM101
RS-485 communication lines can connect 31 power monitors at up to 1200 meters. on-board compact
power monitor
nd monitorin s
twork upport er smoot ergy savin ctuation
ma pow hin s en e flu che
De
g Ne ak ort g
tag
Greater
Pe
law
p
l
g
ck
Vo
Sup
er
pre
spe
ito
fic
ter
4
sup
ien
ring
Com
Multi
Input
Grea
ply
cy
element functional Universal Network
LCD
U V W VT
Power company Replace multiple analog
PT
meters with a single unit
Digitization
Wh W PF Hz V A CT
CT
Also measures reactive power, demand current, demand
Load power, and other values, and comes with pulse output and
B+
communication output functions. LOAD POWER SUPPLY A- COMMUNI
L+ 8 17 16 SG -CATION
1 OUTPUT
9 19 18 TERM
Improved visibility N-
2 10 20
SHIELD
12 PULSE+ PULSE
Easy-to-read bar graph display, and numeric display of any 4 13 25 24 OUTPUT
elements simultaneously. 14 27 26 PULSE-
PE 7 ALM+ ALARM
15 28
29
EXT. INPUT ALM- OUTPUT
DI+
DI-
PR720 as a Three-phase Three-wire System
Universal
Measurement
Demand measurement 3
function
100-240V AC±10% (50/60Hz), 80-143V
Power supply -6
Power supply: 100–240 VAC and 80–143 VDC (both AC and DC uses) DC
Input specifications: Use parameters to switch between Phase indication
U, V and W indications U
single-phase two-wire, single-phase three-wire, and three-phase format
three-wire Always 0 -0
tr
tra
cti
rin
Easy
Cen
ons
Cen
g
Low 920 MHz
price install wireless Network
ation
GM
920MHz
RS-485
No need to
cut the line
Plus, the UPM101 comes
standard with dedicated Existing CT
compact CTs. Simply clamp UPM100 UPM100 UPM100 UPM100
a dedicated CT on the (with 920 MHz wireless communication*)
secondary side line of the
existing CT, and save the
cost and labor of installing
One-step
attachment with UPM101
Powerful measurement functions
a new CT. the attached CT
Supports three-phase 4-wire, and has a rated input of 440 V. A
variety of measurement functions including reactive power,
Model and suffix code [UPM100] apparent power, and frequency.
Model UPM100 - -20
Model and suffix code [UPM101]
Phase and Single-phase 2-wire 1
wire type Single-phase 3-wire 2 Model UPM101 - -20
Three-phase 3 wire 3 Phase and Single-phase 2-wire (with 1 dedicated CT) 1
wire type Single-phase 3-wire (with 2 dedicated CTs) 2
Three-phase 4 wire 4
Rated input*3 220 V (127 V)/1 A AC*1 3 Three-phase 3-wire (with 2 dedicated CTs) 3
voltage/ 220 V (127 V)/5 A AC*1 4 Three-phase 4-wire (with 3 dedicated CTs) 4
current Rated input*3
440 V (277 V)/1 A AC 5 220 V (127 V)/5 A AC*1 4
voltage/
440 V (277 V)/5 A AC 6 current 440 V (277 V)/5 A AC 6
Output Without display function, without pulse output 0 Output Without display function, without pulse output 0
Function With display function, without pulse output 1 Function With display function, without pulse output 1
Without display function, with pulse output 2 Without display function, with pulse output 2
With display function, with pulse output 3 With display function, with pulse output 3
Optional None (RS-485 is provided as standard) 0 Optional
communication communication None (RS-485 is provided as standard) 0
functions Wireless communication (with serial gateway function)*4 C
functions
Optional Integral resolution kWh 0 Optional Integral resolution kWh 0
measurement Integral resolution kWh / power factor 1 measurement Integral resolution kWh / power factor
functions 1
Integral resolution kWh*2 / reactive power, integrated functions
2 Integral resolution kWh*2 / reactive power, integrated
reactive power 2
reactive power
Integral resolution kWh*2 / power factor, reactive power, Integral resolution kWh*2 / power factor, reactive power,
3 3
integrated reactive power integrated reactive power
Integral resolution Wh 4 Integral resolution Wh 4
Integral resolution Wh / power factor 5 Integral resolution Wh / power factor 5
Integral resolution Wh*2 / reactive power, integrated Integral resolution Wh*2 / reactive power, integrated
6 6
reactive power reactive power
Integral resolution Wh*2 / power factor, reactive power, Integral resolution Wh*2 / power factor, reactive power,
7 7
integrated reactive power integrated reactive power
*1. 200 VAC (100 V + 100 V) for single-phase 3-wire. *2. When selecting reactive power, the units are kvar or var. *3. Parentheses ( ) means phase three-phase 4-wire
*4. 920 MHz wireless communication model is for Korean market only.
UPM100 *1
Report files
Web application (On line monitoring)
Real-time display of integrated bar graphs
and integrated trends based on power
RS-485 data recorded and saved by the SMART-
DAC+ GM.
*1 920 MHz wireless communication model of UPM100 is for Korean market only.
*2 920 MHz wireless communication model of SMARTDAC+ GM is for Korean or US market only.
With GA10 data logging Data Logging Software GA10 (Integrated Monitoring Software)
software, easily ingetrate
the SMARTDAC+ GM and
expand the system
Ethernet
RS-485 RS-485
VJET VJET
UPM100 UPM100 UPM100 UPM100 PR720 PR720
Appearance
With CTs
Accuracy rating (voltage/current, power) Energy, Power factor: ±2.0% ±1.0% ±2.0% (with dedicated CT)
Size (H × W × D mm) 110×110×120 106 × 100 × 60 (excluding wireless connector) 106 × 100 × 60
AC 85 to 264V 50/60 Hz 10 VA
Power supply AC 100 to 240V +10%, -15%
DC 80 to 143V 6W
Weight Approx. 600g Approx. 400 g Approx. 400 g (w/o dedicated CT)
= Standard, = Universal, = Added cost
*1. Two pulse outputs proportional to the active power and regenerative energy/reactive energy (LAG) (with reactive power option).
*2. 920 MHz wireless communication model is for Korean market only.
The power monitor and pulse integrator are not to be used as certified supply meter or verification instruments as mandated by the metering law.
Appearance
Gauge standard Less than Φ24 mm Less than Φ36 mm Less than Φ24 mm Less than Φ36 mm
Rated primary current
100 A 200 A 500 A 800 A 100 A 300 A
(In)
Rated secondary current 1A 1A 5A 5A 1A 1A
Rated load 0.5 VA 0.5 VA 2.5 VA 2.5 VA 0.3 VA 0.5 VA
Accuracy/linearity ±1.0% of rated primary current In
Notes Built-in hazardous voltage suppressor that functions when the current transformer secondary side is open.
GA10
GM Data Acquisition Data Logging Software Ethernet/RS-485 converter PID controller
GM10 GA10
(with wireless communication)
SMARTDAC+ GM with a 920 MHz Monitors and records data from a Through VJET, instruments with RS-485 UT32A/MDL
wireless communication can easily variety of instruments via networks. communication can connect to the Can function as a wireless relay.
acquire and record data. Ethernet.
920 MHz wireless communication models of GM10 and UT32A/MDL are for Korean market only.
https://www.yokogawa.com/ns/powercert/ https://partner.yokogawa.com/global/
Trademarks
All brand or product names of Yokogawa Electric Corporation in this bulletin are trademarks or registered trademarks of Yokogawa Electric Corporation.
All other company brand or product names in this bulletin are trademarks or registered trademarks of their respective holders.