You are on page 1of 8

Power and Energy Meter

Power and Energy Meter PR720


Universal Power Monitor UPM100/UPM101

Bulletin 77C01A02-01EN
For swithchboard mounting...
Power and
Energy Meter PR720
As a power equipment meter
As an energy savings monitor

DIN rails for on-board mounting,


or wall-mountable...
Universal Power Monitor

UPM100/UPM101
As an energy savings monitor

High quality power


monitoring supported
by YOKOGAWA’s
power measurement
technology

Install without
disconnecting existing equipment
Clamp-on Current Transformers

CTW
The sales area of PR720/UPM100/CTW is limited,
please contact your nearest Yokogawa’s sales office or sales representative.
920 MHz wireless communication model of UPM100 is for Korean market only.

1 OpreX Components: Power and Energy Meter


Reduce power costs, supports the Energy Conservation Act and
ISO14001, and as power equipment,

Aids the digitalization of power monitoring


from the factory to the office
Power
supply Broad power monitoring-based solution system

Factory Power company

Reading
meter PR720 panel-mount monitor for power equipment Powerful support for
real time monitoring,
analog me erload check ol meter r analysis, reports, and
PR720 izes te Ov patr ea
ral ce demand monitoring of

u
t

rin

din
Cen

Red
power data.
g

Reduces Preventative Equipment

g
equipment equipment management Data Logging Software
costs maintenance labor saving
GA10

VJET

Ethernet
VJET

Print reports

PR720 PR720 PR720 PR720


RS-485 RS-485 RS-485

Circuit Circuit Circuit Circuit


breaker breaker breaker breaker Ethernet

VJET

Pump, fan, freezer Manufacturing equipment/line A/C, lighting, outlets Elevators, OA equipment

For energy savings:

PR720 panel-mount
power monitor
UPM100 UPM100 UPM100 PR720
RS-485
UPM100/UPM101
RS-485 communication lines can connect 31 power monitors at up to 1200 meters. on-board compact
power monitor
nd monitorin s
twork upport er smoot ergy savin ctuation
ma pow hin s en e flu che
De
g Ne ak ort g
tag
Greater
Pe

law
p

l
g

ck
Vo
Sup

Reduce Increase Preventative


s

efficiency with Output level


contract equipment equipment
more advanced management
power up-time maintenance
equipment

OpreX Components: Power and Energy Meter 2


PR720
A panel-mount power monitor that precisely meets the
dual needs of power equipment metering and energy
saving monitoring.

ior visibili r monitoring ions and po e power m


per ty we ef icat w nsiv on
Su po cif he

er

pre
spe

ito
fic
ter
4

sup
ien

ring
Com
Multi

Input
Grea

ply
cy
element functional Universal Network
LCD

Multimeter and 4 element Power monitoring with


simultaneous display demand alarm
Display any 4 measuring elements and together on the LCD. and communication function
Simultaneously monitor measured values from three-phase
circuits such as three-phase current/voltage. One unit can replace Increased power monitoring efficiency by condensing these
multiple meters, greatly reducing cost, space, and wiring. functions into a single unit: watt hour integral pulse output, alarm
output of demand current/demand power, RS-485 communication
(Modbus), and others.

U V W VT
Power company Replace multiple analog
PT
meters with a single unit
Digitization
Wh W PF Hz V A CT

CT
Also measures reactive power, demand current, demand
Load power, and other values, and comes with pulse output and
B+
communication output functions. LOAD POWER SUPPLY A- COMMUNI
L+ 8 17 16 SG -CATION
1 OUTPUT
9 19 18 TERM
Improved visibility N-
2 10 20
SHIELD
12 PULSE+ PULSE
Easy-to-read bar graph display, and numeric display of any 4 13 25 24 OUTPUT
elements simultaneously. 14 27 26 PULSE-
PE 7 ALM+ ALARM
15 28
29
EXT. INPUT ALM- OUTPUT

DI+

DI-
PR720 as a Three-phase Three-wire System

Model and suffix code [PR720]


Model PR720 -3 2 2 0 3 -6 U -0
Universal three-phase three-wire
Phase and system (single-phase two-wire,
-3
wire system single-phase three-wire, and three-
phase three-wire systems)
Rated input Universal voltage input
2
voltage/current (150V/300V)/5A
Compatible with conventional 110-square mechanical meters. No Input and
1 digital input, 1 pulse output 2
need to redesign the mounting panel. output function
Communication
RS-485 communication 0
function

Universal
Measurement
Demand measurement 3
function
100-240V AC±10% (50/60Hz), 80-143V
Power supply -6
Power supply: 100–240 VAC and 80–143 VDC (both AC and DC uses) DC
Input specifications: Use parameters to switch between Phase indication
U, V and W indications U
single-phase two-wire, single-phase three-wire, and three-phase format
three-wire Always 0 -0

3 OpreX Components: Power and Energy Meter


UPM100/UPM101
Powerful support for energy savings analysis. This
compact power monitor can measure fifteen power
elements such as integrated power on a single unit.

o minimize ail/wall moun Saves labo power mon


es t fun Nr zes ito
liz DI t ali

tr
tra

cti

rin
Easy

Cen
ons
Cen

g
Low 920 MHz
price install wireless Network
ation

Low price 920 MHz wireless (For Korean market only)


In addition to active energy, a single unit measures regenerative Because 920 MHz wireless has a longer range than the 2.4 GHz
energy, reactive energy, power factor, and other phenomena. band (such as wireless LAN) and has greater reach around
obstacles, it can be used in long-distance applications or where
there are many obstructions.
Easy installation Web screens for power monitoring

One-step mounting on DIN rails. And PC


of course, you can wall-mount it with
screws.

GM
920MHz
RS-485
No need to
cut the line
Plus, the UPM101 comes
standard with dedicated Existing CT
compact CTs. Simply clamp UPM100 UPM100 UPM100 UPM100
a dedicated CT on the (with 920 MHz wireless communication*)
secondary side line of the
existing CT, and save the
cost and labor of installing
One-step
attachment with UPM101
Powerful measurement functions
a new CT. the attached CT
Supports three-phase 4-wire, and has a rated input of 440 V. A
variety of measurement functions including reactive power,
Model and suffix code [UPM100] apparent power, and frequency.
Model UPM100 - -20
Model and suffix code [UPM101]
Phase and Single-phase 2-wire 1
wire type Single-phase 3-wire 2 Model UPM101 - -20
Three-phase 3 wire 3 Phase and Single-phase 2-wire (with 1 dedicated CT) 1
wire type Single-phase 3-wire (with 2 dedicated CTs) 2
Three-phase 4 wire 4
Rated input*3 220 V (127 V)/1 A AC*1 3 Three-phase 3-wire (with 2 dedicated CTs) 3
voltage/ 220 V (127 V)/5 A AC*1 4 Three-phase 4-wire (with 3 dedicated CTs) 4
current Rated input*3
440 V (277 V)/1 A AC 5 220 V (127 V)/5 A AC*1 4
voltage/
440 V (277 V)/5 A AC 6 current 440 V (277 V)/5 A AC 6
Output Without display function, without pulse output 0 Output Without display function, without pulse output 0
Function With display function, without pulse output 1 Function With display function, without pulse output 1
Without display function, with pulse output 2 Without display function, with pulse output 2
With display function, with pulse output 3 With display function, with pulse output 3
Optional None (RS-485 is provided as standard) 0 Optional
communication communication None (RS-485 is provided as standard) 0
functions Wireless communication (with serial gateway function)*4 C
functions
Optional Integral resolution kWh 0 Optional Integral resolution kWh 0
measurement Integral resolution kWh / power factor 1 measurement Integral resolution kWh / power factor
functions 1
Integral resolution kWh*2 / reactive power, integrated functions
2 Integral resolution kWh*2 / reactive power, integrated
reactive power 2
reactive power
Integral resolution kWh*2 / power factor, reactive power, Integral resolution kWh*2 / power factor, reactive power,
3 3
integrated reactive power integrated reactive power
Integral resolution Wh 4 Integral resolution Wh 4
Integral resolution Wh / power factor 5 Integral resolution Wh / power factor 5
Integral resolution Wh*2 / reactive power, integrated Integral resolution Wh*2 / reactive power, integrated
6 6
reactive power reactive power
Integral resolution Wh*2 / power factor, reactive power, Integral resolution Wh*2 / power factor, reactive power,
7 7
integrated reactive power integrated reactive power
*1. 200 VAC (100 V + 100 V) for single-phase 3-wire. *2. When selecting reactive power, the units are kvar or var. *3. Parentheses ( ) means phase three-phase 4-wire
*4. 920 MHz wireless communication model is for Korean market only.

OpreX Components: Power and Energy Meter 4


Compact power monitoring package
Power integration screen Hardware Configurator
Monitor on a tablet (Power monitor setup wizard)
that can display
Wizard-based UPM100 and SMARTDAC+
integrated bar graphs, PC
GM connection setup.
and an integrated trend
display function.
Wi-Fi router
Setup wizard to help you
build power monitoring
applications.
Universal Viewer (Off line monitoring)
Ethernet
Displays integrated bar graphs and
integrated trends. Printing function
*2

UPM100 *1

Report files
Web application (On line monitoring)
Real-time display of integrated bar graphs
and integrated trends based on power
RS-485 data recorded and saved by the SMART-
DAC+ GM.

*1 920 MHz wireless communication model of UPM100 is for Korean market only.
*2 920 MHz wireless communication model of SMARTDAC+ GM is for Korean or US market only.

With GA10 data logging Data Logging Software GA10 (Integrated Monitoring Software)
software, easily ingetrate
the SMARTDAC+ GM and
expand the system

Power monitor related products


Recorder-based data acquisition, monitoring, and transfer.
Power monitoring using Record power data on the SMARTDAC+ GX/GP over the Ethernet.
Through pulse input and MATH functions, you can build an
acquisition system that delivers energy consumption rate
management.

Ethernet

RS-485 RS-485

VJET VJET
UPM100 UPM100 UPM100 UPM100 PR720 PR720

5 OpreX Components: Power and Energy Meter


Power monitor functions
List of power monitor features
Product Power Monitor Universal Power Monitor Universal Power Monitor

Model PR720 UPM100 UPM101

with 920 MHz wireless


communication*2

Appearance

With CTs

Single-phase 2-wire With 1 CT


Single-phase 3-wire With 2 CTs
Phases/wires
Three-phase 3-wire With 2 CTs
Three-phase 4-wire — With 3 CTs
Yes
Display
No —
Instantaneous
Voltage Max —
Min —
Instantaneous
Current
Max —
Active power Instantaneous
Reactive power Instantaneous
Apparent energy Instantaneous —
Active
Measured
Reactive
elements
Energy Regenerative
Apparent —
Optional electric —
Power factor Instantaneous
Frequency Instantaneous
Demand value — —
Demand current
Max — —
Demand value — —
Demand Power
Max — —
Rated input voltage AC 110V, AC 220V AC 110V, AC 220V, AC 440V
Rated input
Rated input current AC 5A AC 1A , AC 5A AC 5A
Digital input — —
I/O functions Pulse output *1 *1

Demand alarm output — —


VT ratio
Settings
CT ratio
DIN rail —
Mounting Wall —
Panel — —
RS-485
Comunication
920 MHz wireless — —

Accuracy rating (voltage/current, power) Energy, Power factor: ±2.0% ±1.0% ±2.0% (with dedicated CT)

Size (H × W × D mm) 110×110×120 106 × 100 × 60 (excluding wireless connector) 106 × 100 × 60

AC 85 to 264V 50/60 Hz 10 VA
Power supply AC 100 to 240V +10%, -15%
DC 80 to 143V 6W

Weight Approx. 600g Approx. 400 g Approx. 400 g (w/o dedicated CT)
= Standard, = Universal, = Added cost
*1. Two pulse outputs proportional to the active power and regenerative energy/reactive energy (LAG) (with reactive power option).
*2. 920 MHz wireless communication model is for Korean market only.
The power monitor and pulse integrator are not to be used as certified supply meter or verification instruments as mandated by the metering law.

OpreX Components: Power and Energy Meter 6


List of transformers (for the PR720/UPM100)
Type Clamp-on Current Transformers
Model CTW10 CTW20 CTW100 CTW130 CTW15 CTW35

Appearance

Gauge standard Less than Φ24 mm Less than Φ36 mm Less than Φ24 mm Less than Φ36 mm
Rated primary current
100 A 200 A 500 A 800 A 100 A 300 A
(In)
Rated secondary current 1A 1A 5A 5A 1A 1A
Rated load 0.5 VA 0.5 VA 2.5 VA 2.5 VA 0.3 VA 0.5 VA
Accuracy/linearity ±1.0% of rated primary current In
Notes Built-in hazardous voltage suppressor that functions when the current transformer secondary side is open.

Power monitor related products

GA10
GM Data Acquisition Data Logging Software Ethernet/RS-485 converter PID controller

GM10 GA10
(with wireless communication)

SMARTDAC+ GM with a 920 MHz Monitors and records data from a Through VJET, instruments with RS-485 UT32A/MDL
wireless communication can easily variety of instruments via networks. communication can connect to the Can function as a wireless relay.
acquire and record data. Ethernet.

920 MHz wireless communication models of GM10 and UT32A/MDL are for Korean market only.

Web site User Registration Request


For detailed specifications of each model, please see the General Thank you for purchasing YOKOGAWA products.
Specifications. Please register to the following Partner Portal Member Site.
If you have trouble with the power monitor, please see the FAQ. You can use various services such as confirmation of purchased
product information, download of related materials, and newsletter.

https://www.yokogawa.com/ns/powercert/ https://partner.yokogawa.com/global/

Trademarks
All brand or product names of Yokogawa Electric Corporation in this bulletin are trademarks or registered trademarks of Yokogawa Electric Corporation.
All other company brand or product names in this bulletin are trademarks or registered trademarks of their respective holders.

YOKOGAWA ELECTRIC CORPORATION YOKOGAWA ENGINEERING ASIA PTE. LTD. http://www.yokogawa.com/sg/


Edge Solution Business Division http://www.yokogawa.com/ YOKOGAWA ELECTRIC KOREA CO. LTD. http://www.yokogawa.com/kr/
E-mail: ns@cs.jp.yokogawa.com YOKOGAWA TAIWAN CORPORATION http://www.yokogawa.com/tw/
YOKOGAWA INDIA LTD. http://www.yokogawa.com/in/

Subject to change without notice. Printed in Japan, 103(KP)


All Rights Reserved. Copyright © 2019, Yokogawa Electric Corporation [Ed : 02/b]

You might also like