The RMU Digital Upgrade packages can provide The RMU Digital Upgrade packages for SafeRing/
monitoring, control and measurement functiona- SafePlus are integrated in the space behind the
lities - including Feeder Automation (FA) devices lower front cover offering a compact solution.
with wired and/or wireless communication inter- ABB also provides another solution with an addi-
faces and power supply backup. tional low voltage compartment installed on top of
the switchgear.
Customer benefits
• Gain more efficient utilization of the secondary Benefits of the compact secondary substation
distribution network through automation and automatization:
thus minimize the effect of power outages. • Improved quality of the power supply:
• Wireless modem GPRS/3G/LTE communicating -- Less and shorter outages.
with your DMS or SCADA system. -- Improvement of the operational efficiency.
The RMU Digital Upgrade functionalities enable the Optimal utilization of the distribution network:
network operators to: • Utilize the network more efficiently, and minimize
• Obtain real time data for analyzing and decision the network losses.
making, in order to optimize operations and • Optimal asset management.
improve power quality. • Measurements of power flows/quality.
• Monitor the grid to enable remote fault locali- • Improves overview of power network.
zation. • Extends life cycle of the earlier investments.
• Reconfigure the network to isolate the faulty part
of the network, to ensure faster power restoration Improves efficiency and safety of operating
reducing the cost of energy loss. personnel:
• Less need to travel to places difficult to reach.
Enclosed FA box inside the RMU: • Less need to work in dangerous environments.
• Fully integrated solution in the RMU, less space
consuming.
• Less affected by the environment.
• Fast and plugable installation.
• No impact on compact secondary substation
IP rating.
Functionality levels
The RMU Digital Upgrade covers Level 1, 2 and 3 of the below functionality levels:
Level 4
Selectivity
Protection
Protection
Line Circuit
Breakers
Level 3
Management
Power Flow
Measurement Measurement
Accurate MV Accurate MV
Measurements Measurements
Level 2
Control Control Control
Isolation
Fault
© ABB Group
March 6, 2018 | Slide 1
— —
1VDD300001 EN_2018.03
ABB AS We reserve the right to make technical We reserve all rights in this document and
Amtm. Aallsgt. 73 changes or modify the contents of this in the subject matter and illustrations
P.O. Box 108, Sentrum document without prior notice. With re- contained therein. Any reproduction, dis-
3716 Skien, Norway gard to purchase orders, the agreed par- closure to third parties or utilization of its
ticulars shall prevail. ABB AG does not ac- contents – in whole or in parts – is forbid-
cept any responsibility whatsoever for den without prior written consent of ABB
potential errors or possible lack of infor- AG. Copyright© 2018 ABB
mation in this document. All rights reserved
abb.com/service