SS-280-60P 60 cells

265-280W
Management System
ISO 9001: Quality Management System
ISO 14001: Environmental Management System Standard
OHSAS 18001: International Occupational Health and
Safety Assessment System Standard

Product Certification

Product Insurance

Product Guarantee
100%
97.5%
97.5% Line
ar q
Guaranteed power

94.7% uali
tygua
rant
ee p
91.2% rov
90% ides
mor
87.7% e ea
rnin
gs
84.2%

80.7%
80%

0 5 10 15 20 25
years

10 years
Product quality
& process guarantee 25
years
Linear power guarantee

Safety Reliability High performance


Resistance to salt-spray Resistance to power attenuation Excellent power output of
Advanced
corrosion passed system modules in low light
(IEC61701, certified to test FREE voltage endurance test environment
standard)

Resistance to ammonia 100% double EL test enabling


NH3 Corrosion remarkable reduction of
(IEC62716, certified to test hidden crack rate of modules
standard)

Fire safety
(Class C, certified to
and Rheinland test standards)

Specifications are subject to change without prior notice

POWERING THE FUTURE


SS-280-60P 60 cells

Electric characteristics(STC)
Model of modules SS-265-60P SS-270-60P SS-275-60P SS-280-60P
35±1
Maximum power- Pmp (W) 265 270 275 280
Junction box
Open-circuit voltage-Voc(V) 38.3 38.5 38.8 39.0 Mounting hole

Short-circuit current-Isc(A) 8.83 8.94 9.02 9.12


SERIAL NUMBER

I
Barcode
Nameplate
Maximum power voltage-Vmp(V) 31.1 31.3 31.6 31.8

Cell color card

1100±1
Maximum power current- Imp(A) 8.53 8.63 8.71 8.81
1
0± Grounding hole
Module efficiency- ηm(%) 16.29 16.6 16.9 17.2 Ø2 2×Ø 4
10±1

1640±1
1360±1
860±1
STC:Irradiance 1000 W/m2, 25℃, AM1.5

Barcode
Negative electrode(-)
Electric characteristics(NOCT)
Positive electrode(+)
A A
Connector
Model of modules SS-265-60P SS-270-60P SS-275-60P SS-280-60P

Maximum power- Pmp (W) 196 200 203 206 Ⅱ


Open-circuit voltage - Voc(V) 35.3 35.5 35.7 35.9

Short-circuit current-Isc(A) 7.14 7.22 7.29 7.36 942±1


Voltage at maximum power-Vmp(V) 992±1
29.1 29.3 29.5 29.7
Current at maximum power-Imp(A) 6.74 6.83 6.88 6.94
35
9

.5
NOCT: lrradiance 800 W/m2, 20℃, wind velocity 1m/s

R4
Power tolerance (W) (0,+5)

35
14
Maximum system voltage (V) 1000V/1500V
I II
Maximum rated fuse current (A) 20 2:1 Sectional view A-A
5:1
10:1

* Unit: mm
Temperature characteristics
Temperature coefficient at maximum power -0.41 %/°C

Temperature coefficient at open-circuit voltage -0.32 %/°C I-V curves(SS-280-60P)


Temperature coefficient at short-circuit current +0.05 %/°C
10
Cells temp. = 25 °C
Operating temperature -40~+85 °C Incident Irrad. = 1000 W/m²

Rated operating temperature of cells 45±2 °C 8


Incident Irrad. = 800 W/m²

6
Current(A)

Incident Irrad. = 600 W/m²


Packaging Configuration
4 Incident Irrad. = 400 W/m²
Container 20GP 40GP 40HC

Quantity/pallet 30 30 30 2 Incident Irrad. = 200 W/m²

Pallets/container 14 28 28

Quantity/container 400 840 924 0


0 5 10 15 20 25 30 35 40

Voltage(V)
10

Structural characteristics 8

Module dimensions 1640 x 992 x 35 mm 6


Current(A)

Weight 17.5 kg
4 Incident Irrad. = 1000 W/m²
Cell Polycrystal 156.75×156.75 mm (60 cells)
Cells temp. = 10 °C
Cells temp. = 25 °C
Glass 3.2mm AR tempered glass, low iron Cells temp. = 40 °C
2 Cells temp. = 55 °C
Cells temp. = 70 °C
Frame Anodized aluminum alloy

Junction box IP67 0


0 5 10 15 20 25 30 35 40

Output wire 4.0 mm2, wire length: 1100 mm Voltage(V)


Connector MC4 compatible
Mechanical load 5400 Pa

Specifications are subject to change without prior notice

POWERING THE FUTURE