CALCULATION OF FILTERING SCUM RAW SYRUP

TCD 18000 ton per day


RAW SYRUP 30 % Cane

SCUM CONTENT:
MIN 0.11 % RS
MAKS 1.64 % RS

HW DILUTION : 4 x Scum

HW Dilution Total Material


Est. Raw Syrup Est. Scum (ton/Hr)
(ton/Hr) (ton/Hr)
(ton/Hr)
Min Maks Min Maks Min Maks
225 0.2475 3.69 0.99 14.76 1.2375 18.45

Safe 20% 22.14 ton/Hr

Equipment Request :
Equipment Request Capacity Function
Colection of scum and mixing with filter
Scum tank 1 15 m3, complete with stirer
aid
Scum liquid pump min 1 30 m3/hr, head 20 m Distribution of scum liquid to filter press

Filter cake cap. 30m3/Hr, Filter cake


Filter pressed min 1 Recovery sugar from scum
thick 30 mm, and hydrolic system

Filtrat Tank 1 15 m3 Colecting filtrat from filter press

Filtrat Pump min 1 30 m3/hr, head 20 m Distribution of filtrat to the next process
(clear juice tank or defecator)

Note:
Drawing arrangement