You are on page 1of 16

Blocked for new applications / Für Neuanwendung gesperrt

4/3, 4/2 and 3/2 directional valve RE 23178/12.05


Replaces: 04.05
1/16

with wet-pin AC or DC solenoid

Type WE 6 …E

Size 6
Component series 6X
Maximum operating pressure 350 bar [5100 psi]
Maximum flow: 80 l/min [21 gpm] – DC
60 l/min [15.8 gpm] – AC
H5909

Table of contents Features


Contents Page – Direct operated directional spool valve, solenoid actuated, in
Features 1 heavy-duty configuration
Order code 2 – Port pattern as per DIN 24340 form A (without locating bore)
Standard types 3 – Port pattern as per ISO 4401-03-02-0-94, NFPA T3.5.1 MR1
and ANSI B93-7 D03 (with locating bore/anti-rotation pin)
Mating connectors 3
– For subplates, see data sheet RE 45052 (order separately)
Spool symbols 4
– Wet-pin AC or DC solenoids with removeable coil
Function, cross-section 5
– Solenoid coil can be rotated through 90°
Technical data 6, 7
– Pressure-tight chamber need not be opened for coil
Characteristic curves 8
replacement
Power limits 8 to 10
– Electrical connection direct on coil or central via conduit box
Dimensions 11 to 15
– Manual override, optional
– Soft shift version, see RE 23183
– Inductive position indicator, contact-free, see RE 24830
– Other electrical connection see RE 08010

Information on available spare parts:


www.boschrexroth.com/spc
Blocked for new applications / Für Neuanwendung gesperrt
2/16 Bosch Rexroth AG Hydraulics WE 6 …E RE 23178/12.05

Order code

WE 6 6X E *

3 main ports =3 Further


4 main ports =4 details in clear text
NG 6, ISO4401-3, =6 No code = Without
NFPA/ANSI D03 Interface locating bore
Spool symbols, e.g. C, E, EA, EB, etc; /60 2) = With locating bore
for possible versions, see page 4 /62 = With locating
bore and anti-rotation pin
Component series 60 to 69 = 6X ISO 8752-3x8-St
(60 to 69: unchanged installation and
connection dimensions) Seal material
No code = NBR seals
Spring return = No code
V= FKM seals
Without spring return =O
(other seals on enquiry)
Without spring return with detent = OF
Caution!
Heavy-duty solenoid =E Observe compatibilty of seals
wet-pin with removeable coil with the hydraulic fluid used!
24 V DC = G24 Clamping length
230 V AC 50/60 Hz = W230 No code = 42 mm (standard)
120 V oder 110 V AC 50 or 60 Hz = W110 Z= 22 mm
= W + voltage
No code = Without throttle insert
205 V DC = G205 1)
With throttle insert (see table)
Built-in rectifier / DC coils for 50/60 Hz AC voltage = W110R
(only available with central connection, Throttle orifice Ø in mm
a D connector type conduit box, see page 3) Port
0,8 1,0 1,2
For further ordering codes for other voltages
and frequencies, see page 7 P = B08 = B10 = B12

With concealed manual override (standard) = N9 A = H08 = H10 = H12


With manual override =N B = R08 = R10 = R12
Without manual override = No code A and B = N08 = N10 = N12
T = X08 = X10 = X12
1) If a DC solenoid is to be conneced to AC voltage, then a rectifier
For use when the flow is higher than
must be used, suitable AC voltages are defined in the table below.
performance limit of the valve.
When using individual coil connections, a mating connector with (see remark page 5)
integrated rectifier may be used. (order separately)
Electrical connection 3)
2) Requires anti- Rotation pin as per ISO 8752-3x8-St,
Individual connection
material number R900005694. K4 4) = Without mating connector with
(order separately for .../60 option) connector as per DIN EN 175301-803
3) Also available with M12 connector (option ...G24... only) Central connection
For order code and mating connectors, see RE 08010. DL = Strain relief on box, with lights (LED)
4) DIN mating connector, order separately, see page 3. DKL 5) = Central connector on box, with
5) Mating connector, order separately, material number R900005538 lights (LED) (without mating connector)
For electrical connection options see RE 08010

Note!

AC electricity supply Nominal voltage of the DC For standard types, see page 3!
Order
code

system (permissible solenoid when operated


voltage tolerance ± 10%) with rectified AC voltage
110 V - 50/60 Hz 96 V G96
230 V - 50/60 Hz 205 V G205
Blocked for new applications / Für Neuanwendung gesperrt
RE 23178/12.05 WE 6 …E Hydraulics Bosch Rexroth AG 3/16

Standard types

Type Material number Type Material number


4WE 6 J6X/EG12N9K4 R900567496 4WE 6 D6X/EW110N9K4 R900551704
3WE 6 A6X/EG24N9K4 R900561180 4WE 6 D6X/OFEW110N9K4 R900552321
3WE 6 B6X/EG24N9K4 R900561270 4WE 6 E6X/EW110N9K4 R900558641
4WE 6 C6X/EG24N9K4 R900561272 4WE 6 J6X/EW110N9K4 R900551703
4WE 6 C6X/OFEG24N9K4 R900564107 3WE 6 A6X/EW230N9K4 R900915672
4WE 6 D6X/EG24N9K4 R900561274 4WE 6 C6X/EW230N9K4 R900913132
4WE 6 D6X/0FEG24N9K4 R900567512 4WE 6 D6X/EW230N9K4 R900909559
4WE 6 E6X/EG24N9K4 R900561278 4WE 6 D6X/OFEW230N9K4 R900915095
4WE 6 EA6X/EG24N9K4 R900561280 4WE 6 E6X/EW230N9K4 R900912492
4WE 6 EB6X/EG24N9K4 R900561281 4WE 6 H6X/EW230N9K4 R900912494
4WE 6 G6X/EG24N9K4 R900561282 4WE 6 J6X/EW230N9K4 R900911762
4WE 6 H6X/EG24N9K4 R900561286 4WE 6 Y6X/EW230N9K4 R900909415
4WE 6 HA6X/EG24N9K4 R900549534
4WE 6 J6X/EG24N9K4 R900561288
4WE 6 M6X/EG24N9K4 R900577475 For additional standard types and components
please contact Product Support.
4WE 6 Q6X/EG24N9K4 R900561292
4WE 6 R6X/EG24N9K4 R900571012
4WE 6 T6X/EG24N9K4 R900934414
4WE 6 U6X/EG24N9K4 R900572785
4WE 6 W6X/EG24N9K4 R900568233
4WE 6 Y6X/EG24N9K4 R900561276

Mating connectors (DIN EN 175301-803)

For details
and additional
mating connectors,
see RE 08006

Material Numbers
With LED lamp
and
Valve side

With LED lamp Zener diode


Cable With LED lamp and rectifier With rectifier suppressor circuit
gland Color Without circuitry 12 … 240 V 12 … 240 V 12 … 240 V 24 V
a grey R901017010 – – – –
M16 x 1,5 b black R901017011 – – – –
a/b black – R901017022 R901017029 R901017025 R901017026
a red/brown R900004823 – – – –
1/2“ NPT
b black R900011039 – – – –
(Pg16)
a/b black – R900057453 R900057455 R900842566 –
Blocked for new applications / Für Neuanwendung gesperrt
4/16 Bosch Rexroth AG Hydraulics WE 6 …E RE 23178/12.05

Spool symbols
A B A B A B A B

a b a b a 0 b a 0 b
a b a b
P T P T P T P T
A B A B A B A B
= .A 1)
a b a a b b = …/O.. a 0
a
a 0
P T P T P T P T
A B A B A B A B
= .B
a b a a b b = …/OF.. 0 b 0 b
b
P T P T P T P T

= E 1)
=A = E1- 2)

=C =F

=D =G

=H
A B A B

a b a b
a b
=J
P T P T

=B =L

=Y =M

=P

=Q

=R

=T

=U

1) Example:
Spool symbol E with coil on side a, order code ..EA..
=V
2) Symbol E1-: P – A/B pre-opening,
Be careful with single-rod cylinders due to pressure
intensification! =W
Blocked for new applications / Für Neuanwendung gesperrt
RE 23178/12.05 WE 6 …E Hydraulics Bosch Rexroth AG 5/16

Function, cross-section

Type WE control valves are solenoid operated directional spool Type .WE 6.. 6X/O... (possible only with symbols A, C and D)
valves. They control the start, stop and direction of a flow. This version refers to two position directional spool valves
These directional valves basically consist of a housing (1), one consisting of two solenoids without detent. When de-
or two solenoids (2), a control spool (3) as well as one or two energized, there is no predefined spool position.
return springs (4). Type .WE 6.. 6X/OF... (detent spool, possible only with
In the inactive condition, the control spool (3) is held in the symbols A, C and D)
central or initial position by return springs (4) (except for detent This version refers to two position directional spool valves
spools). Control spool (3) is actuated by wet-pin solenoids (2). consisting of two solenoids and a detent. Detent holds the
The force of solenoid (2) acts via plunger (5) on control spool spool at it‘s most recent position, and continuous solenoid
(3) and shifts it from it´s initial position to the required end excitation is not required.
position. This enables the required direction of flow, P to A and Note!
B to T or P to B and A to T.
Pressure peaks in a tank line connected to two or more
After solenoid (2) is de-energized, control spool (3) is again detent type valves, can cause unintended spool move-
pushed to it´s initial position by return spring (4). ment! In this situation, it is recommended that separate
Manual override (6) allows control spool (3) to be moved return lines be used or a check valve must be installed in
without energizing the solenoid. the tank line.

2 5 1 3 5 2
A B
6 6

"a" "b"

4 A T B 4
(P)
Type 4WE 6 E6X/...E...

Throttle insert (type .WE 6..6X/…/B.. )


The use of throttle inserts is required, when, due to prevailing
operating conditions, flows can occur during valve switching,
that exceed the power limits of the valve. These orifices are
inserted into the valve body‘s P-port.
Blocked for new applications / Für Neuanwendung gesperrt
6/16 Bosch Rexroth AG Hydraulics WE 6 …E RE 23178/12.05

Technical data (for applications exceeding these parameters, please consult product support!)

General
Weight – Valve with one solenoid kg [lbs] 1.45 [3.2]
– Valve with two solenoids kg [lbs] 1.95 [4.3]
Mounting orientation Unrestricted
Ambient temperature range °C [°F] –30 to +50 [–22 to +122] (NBR seals)
–20 to +50 [–4 to +122] (FKM seals)

Hydraulic
Maximum operating pressure – Ports A, B, P bar [psi] 350 [5100]
– Port T bar [psi] 210 [3050] (DC); 160 [2320] (AC)
For symbols A and B, port T must be used as the drain
port, if the operating pressure is higher than the tank
pressure.
Maximum flow l/min [gpm] 80 [21] (DC); 60 [15.8] (AC)
Flow cross-section – Spool symbol Q mm2 approx. 6 % of nominal cross-section
(centered spool)
– Spool symbol W mm2 approx. 3 % of nominal cross-section
Hydraulic fluid Mineral oil (HL, HLP) to DIN 51524 1); fast bio-de-
gradable hydraulic fluids to VDMA 24568 (see also
RE 90221); HETG (rape-seed oil) 1); HEPG (polygly-
cols) 2); HEES (synthetic esters) 2); other hydraulic
fluids upon request
Hydraulic fluid temperature range °C [°F] –30 to +80 [–22 to +176] (NBR seals)
–15 to +80 [–4 to +176] (FKM seals)
Viscosity range mm2/s [SUS] 2,8 to 500 [35 to 2320]
Max. permissible degree of contamination of the Class 20/18/15 3)
hydraulic fluid - cleanliness class to ISO 4406 (c)
1) Suitable for NBR and FKM seals
2) Suitable only for FKM seals
3) The cleanliness classes specified for components must be
adhered to in hydraulic systems. Effective filtration prevents
malfunction and, at the same time, increases the service life
of components.
For the selection of filters, see data sheets RE 50070,
RE 50076, RE 50081, RE 50086 and RE 50088.
Blocked for new applications / Für Neuanwendung gesperrt
RE 23178/12.05 WE 6 …E Hydraulics Bosch Rexroth AG 7/16

Technical data (for applications exceeding these parameters, please consult product support!)

Electrical
Voltage type DC AC 50/60 Hz
Available voltages 4) V 12, 24, 96, 205 110, 230
(for AC solenoid order codes, see below)
Voltage tolerance (nominal voltage) % ± 10 ± 10
Power consumption W 30 –
Holding current VA – 50
Inrush current VA – 220
Duty cycle 100 % 100 %

Switching time per ISO 6403 ON ms 25 to 45 10 to 20


OFF ms 10 to 25 15 to 40
Maximum switching frequency 1/h 15000 7200
Maximum coil temperature 5) °C [°F] 150 [302] 180 [356]
Type of protection to DIN EN 60529 6) IP 65 IP 65

4) Other voltages upon request


5) Due to the solenoid coil surface temperatures, please
observe European safety standards EN563 and EN982!
6) With mating connector mounted and secured

Note!
AC solenoids can be used only for 2 or 3 voltage/frequency
relationships; e.g. solenoid type W110 for:
110 V, 50 Hz; 110 V, 60 Hz; 120 V, 60 Hz

Order code Power supply


W110 110 V, 50 Hz
110 V, 60 Hz
120 V, 60 Hz
W230 230 V, 50 Hz
230 V, 60 Hz

When connecting wires, properly connect the PE ground


conductor (PE ) .
Blocked for new applications / Für Neuanwendung gesperrt
8/16 Bosch Rexroth AG Hydraulics WE 6 …E RE 23178/12.05

Characteristic curves (measured with HLP46, oil ( = 190 SUS) = 40 °C ± 5 °C [104 °F ± 9 °F])
Δp-qV characteristic curves
7 8 10 6 5 3 9 1 2
����� 11
Spool Direction of flow
����� 10 4 symbol
Pressure drop in bar [psi] →

P–A P–B A–T B–T


�����
8 A; B 3 3 – –
����� C 1 1 3 1
����
6 D; Y 5 5 3 3
E 3 3 1 1
���� 4
F 1 3 1 1
����
T 10 10 9 9
2
���� H 2 4 2 2
��� J; Q 1 1 2 1
0 10 20 30 40 50 60 70 80
L 3 3 4 9
��� ��� ��� ��� ��� ���� ���� ���� ���� ���� ���� M 2 4 3 3

Flow in l/min [gpm] → P 3 1 1 1


R 5 5 4 –

7 Spool symbol R in spool position B – A V 1 2 1 1


8 Spool symbol G and T in central position P – T W 1 1 2 2
9 Spool symbol H in central position P – T U 3 3 9 4
G 6 6 9 9

Power limits (measured with HLP46, oil ( = 190 SUS) = 40 °C ± 5 °C [104 °F ± 9 °F])
Caution! only one direction of flow (e.g. from P to A, with port B being
The specified switching performance limits are valid with two blocked)!
directions of flow (e.g. from P to A and simultaneous return In such cases, please consult product support!
flow from B to T).
The switching performance limit was determined with the
Due to the flow forces acting within the valve, the permissible solenoid at operating temperature, at 10 % under-voltage
switching performance limit can be significantly lower with and without tank pre-loading.
Operating pressure in bar [psi] →

������ 350
7 9 10 DC solenoid
300 8
������ Char. curve Spool symbol
1 5
������ 200 1 A; B1)
2 6 3
3 2 V
������
4
100 3 A; B
������ 1 4 F; P
2
��� 5 J
0 10 20 30 40 50 60 70 80
6 G; H; T
��� ��� ��� ��� ��� ���� ���� ���� ���� ���� ���� 7 A/O; A/OF; L; U

Flow in l/min [gpm] → 8 C; D; Y


9 M
DC solenoid 10 E; E1–2); R3);
C/O; C/OF
Solenoid voltage D/O; D/OF; Q; W
12; 24; 48; 96; 125; 205 V 1) With manual override
(for other voltages, see page 10) 2) P – A/B pre-opening
3) Return flow from actuator to tank
Blocked for new applications / Für Neuanwendung gesperrt
RE 23178/12.05 WE 6 …E Hydraulics Bosch Rexroth AG 9/16

Power limits (measured with HLP46, oil ( = 190 SUS) = 40 °C ± 5 °C [104 °F ± 9 °F])
– see page 8
Operating pressure in bar [psi] →

������ 350 17
AC solenoid – 50 Hz
300
������
15 18 Char. curve Spool symbol
14
������ 200 11 A; B1)
������ 13 16 12 V
100 13 A; B
������ 14
11 12 14 F; P
��� 15 G; T
0 10 20 30 40 50 60
16 H
��� ��� ��� ��� ��� ���� ���� ����
17 A/O; A/OF; C/O; C/OF; D/O; D/OF;
Flow in l/min [gpm] → E; E1–2); J; L; M; Q; R3); U; W
18 C; D; Y
AC solenoid 1) With manual override
Solenoid voltage
2) P – A/B pre-opening
W110 110 V; 50 Hz 3) Return flow from actuator to tank
120 V; 60 Hz
W230 230 V; 50 Hz
(other voltages upon request)
Operating pressure in bar [psi] →

������ 350 AC solenoid – 60 Hz


26
300 28
������ 21 23 Char. curve Spool symbol
22
������
24 19 A; B1)
200
25
20 V
������
100 21 A; B
������
27 22 F; P
19 20
��� 23 G; T
0 10 20 30 40 50 60
24 J; L; U
��� ��� ��� ��� ��� ���� ���� ���� 25 A/O; A/OF; Q; W
Flow in l/min [gpm] → 26 C; D; Y
27 H
AC solenoid 28 C/O; C/OF; D/O; D/OF; E
Solenoid voltage E1–2); M; R3)
W110 110 V; 60 Hz 1) With manual override
W230 230 V; 60 Hz 2) P – A/B pre-opening
(other voltages upon request) 3) Return flow from actuator to tank
Blocked for new applications / Für Neuanwendung gesperrt
10/16 Bosch Rexroth AG Hydraulics WE 6 …E RE 23178/12.05

Power limits (measured with HLP46, oil ( = 190 SUS) = 40 °C ± 5 °C [104 °F ± 9 °F])
– see page 8
Operating pressure in bar [psi] →

������ 350 11
5 9 10 DC solenoid
300 8
������ Char. curve Spool symbol
1 6
������ 3 1 A; B
200
2 4 6 7 2 V
������ 11
100 3 F; P
������ 5
1 4 J; L; U
2
��� 5 G
0 10 20 30 40 50 60 70 80
6 T
��� ��� ��� ��� ��� ���� ���� ���� ���� ���� ���� 7 H
Flow in l/min [gpm] → 8 D; C
9 M
DC solenoid 10 C/O; C/OF; D/O; D/OF;
Solenoid voltage E; E1–; R, Q; W
110; 180 V 11 A/O; A/OF
Operating pressure in bar [psi] →

������ 350 5 10 DC solenoid


300
������ 6 11
6 Char. curve Spool symbol
2 1 A; B
������ 200 4
12
1 2 V
������ 3 4
100 3 F; P
������ 7 8 9 5 4 J; L; U
2 1
��� 5 A/O; A/OF
0 10 20 30 40 50 60 70 80
6 E
��� ��� ��� ��� ��� ���� ���� ���� ���� ���� ���� 7 T
Flow in l/min [gpm] → 8 G
9 H
10 D; C
DC solenoid 11 M
Solenoid voltage 12 C/O; C/OF; D/O; D/OF;
42; 80; 220 V E1–; R, Q; W
Blocked for new applications / Für Neuanwendung gesperrt
RE 23178/12.05 WE 6 …E Hydraulics Bosch Rexroth AG 11/16

Dimensions: Valve with DC solenoid – individual coil connection


(nominal dimensions in mm [inch])

14 5 11 9 11 5 14 12 12 6

������
15 ������

15
9,4 5,3
������� �������
A B B

97,5 ������
92 ������
23 ������

�������������
42 (22)
4

3 8,4 ������ 8,4 ������ 4


3,5 ������ 22 ������ 64 ������ 3,5 ������
14 ������ 82 ������ 124 ������ 14 ������ 3
50,5 ������ 206 ������ 50,5 ������

13 1.1 16 2 15 10 1.2 13
69,2 ������
13,6 ������

F1
T F2
B
45 ������
A
7 ������

F4
P F3
G

0.0004/4.0 in
0,01/100mm

Rzmax 4

Required surface quality of


the valve mounting face

1.1 Solenoid a (ANSI coil designation see RE 08010) 12 Space required to remove mating connector
1.2 Solenoid b (ANSI coil designation see RE 08010) 13 Space required to remove coil
2 Dimension for solenoid with concealed manual 14 Hand nut, tightening torque MT = 4 Nm [2.95 ft-lbs]
override N9 (standard) – the manual override can only 15 Port pattern as per DIN 24340 form A (without locat-
be operated at tank pressures up to approx. 50 bar ing bore), or ISO 4401-03-02-0-94, NFPA T3.5.1 MR1
[725 psi]. Use tool R900024923 to prevent damage to and ANSI B93-7 D03 interface (with locating bore for
override! anti-rotation pin ISO 8752-3x8-St, material number
3 Dimension for solenoid with manual override N R900005694, order separately for …/60 option)
4 Dimension for solenoid without manual override 16 Alternative clamping length (Z): 22 mm [0.87 inch]
5 DIN mating connector without circuitry (order sepa-
rately, see page 3 and RE 08006) Subplates and valve mounting bolts see page 15.
6 DIN mating connector with circuitry order separately,
see page 3 and RE 08006)
9 Nameplate
10 Identical seal rings for ports A, B, P, T
11 Screw plug for valves with one solenoid
Blocked for new applications / Für Neuanwendung gesperrt
12/16 Bosch Rexroth AG Hydraulics WE 6 …E RE 23178/12.05

Dimensions: Valve with DC solenoid – central coil connection (nominal dimensions in mm [inch])
15 ������
12

8
14
7 11 9 11 14
9,4 5,3
������� �������

131 ������
71 ������

90 ������
71 ������
������

�������������
42 (22)
23

4 8,4 ������ 8,4 ������ 4


3 3,5 ������ 22 ������ 64 ������ 3,5 ������
14 ������ 82 ������ 124 ������ 14 ������ 3
������ 50,5 206 ������ 50,5 ������

13 1.1 16 2 10 15 1.2 13
69,2 ������
13,6 ������ 0.0004/4.0 in
0,01/100mm
F1 F2
7

T Rzmax 4
46,5 ������

45 ������

A B
������

F3 Required surface quality of


F4 P the valve mounting face
G

1.1 Solenoid a (ANSI coil designation see RE 08010) 15 Port pattern as per DIN 24340 Form A (without locat-
1.2 Solenoid b (ANSI coil designation see RE 08010) ing bore), or ISO 4401-03-02-0-94, NFPA T3.5.1 MR1
and ANSI B93-7 D03 interface (with locating bore for
2 Dimension for solenoid with concealed manual
anti-rotation pin ISO 8752-3x8-St, material number
override N9 (standard) – the manual override can only
R900005694, order separately for …/60 option)
be operated at tank pressures up to approx. 50 bar
[725 psi]. Use tool R900024923 to prevent damage to 16 Alternative clamping length (Z): 22 mm [0.87 inch]
override!
3 Dimension for solenoid with manual override N Conduit D box:
4 Dimension for solenoid without manual override Terminal assignment for central connection
7 Cable gland Pg 16 [1/2“ NPT] D or DL – 1 solenoid:
Solenoid always to screw terminals 1 and 2,
8 Angled mating connector (color: red, order separately,
Ground to screw terminal PE
Material number R900005538)
– 2 solenoids:
9 Nameplate
Solenoid on a side to screw terminals 1 and 2,
10 Identical seal rings for ports A, B, P, T Solenoid on b side to screw terminals 3 and 4,
11 Screw plug for valves with one solenoid Ground to screw terminal PE
12 Space required to remove mating connector
13 Space required to remove coil Subplates and valve mounting bolts see page 15.
14 Hand nut, tightening torque MT = 4 Nm [2.95 ft-lbs]
Blocked for new applications / Für Neuanwendung gesperrt
RE 23178/12.05 WE 6 …E Hydraulics Bosch Rexroth AG 13/16

Dimensions: Valve with AC solenoid – individual coil connection


(nominal dimensions in mm [inch])

14 5 11 9 11 5 14 12 12 6

������
������

15
9,4 5,3

15
������� �������
A B B

98 ������
92 ������
������
��������������
42 (22)
3

23
������ 17 8,4 ������ 8,4 ������ 17 ������
22 ������ 64 ������
81 ������ 123 ������
3
������ 44,5 205 ������ 44,5 ������

13 1.1 16 2; 4 10 15 1.2 13
69,2 ������
13,6 ������

F1
7

T
45 ������
F2
A B
������

F3
F4
PG

0.0004/4.0 in
0,01/100mm

Rzmax 4

Required surface quality of


the valve mounting face

1.1 Solenoid a (ANSI coil designation see RE 08010) 10 Identical seal rings for ports A, B, P, T
1.2 Solenoid b (ANSI coil designation see RE 08010) 11 Screw plug for valves with one solenoid
2 Dimension for solenoid with concealed manual 12 Space required to remove mating connector
override N9 (standard) – the manual override can only 13 Space required to remove coil
be operated at tank pressures up to approx. 50 bar
14 Hand nut, tightening torque MT = 4 Nm [2.95 ft-lbs]
[725 psi]. Use tool R900024923 to prevent damage to
override! 15 Port pattern as per DIN 24340 form A (without locat-
ing bore), or ISO 4401-03-02-0-94, NFPA T3.5.1 MR1
3 Dimension for solenoid with manual override N
and ANSI B93-7 D03 interface (with locating bore for
4 Dimension for solenoid without manual override anti-rotation pin ISO 8752-3x8-St, material number
5 DIN mating connector without circuitry (order sepa- R900005694, order separately for …/60 option)
rately, see page 3 and RE 08006) 16 Alternative clamping length (Z): 22 mm [0.87 inch]
6 DIN mating connector with circuitry order separately,
see page 3 and RE 08006)
Subplates and valve mounting bolts see page 15.
9 Nameplate
Blocked for new applications / Für Neuanwendung gesperrt
14/16 Bosch Rexroth AG Hydraulics WE 6 …E RE 23178/12.05

Dimensions: Valve with AC solenoid – central coil connection


(nominal dimensions in mm [inch])
15 ������
12

8 7 11 9 11 14
9,4 5,3
������� �������

131 ������
14
71 ������

90 ������
71 ������

������
��������������
42 (22)

23
������ 17 8,4 ������ 8,4 ������ 17 ������
22 ������ 64 ������
3 81 ������ 123 ������
3
������ 44,5 205 ������ 44,5 ������

13 1.1 15 16 2; 4 10 1.2 13
69,2 ������
13,6 ������ 0.0004/4.0 in
0,01/100mm
F1
7

T Rzmax 4
46,5 ������

45 ������

F2
A B
������

F3 Required surface quality of


F4 P the valve mounting face
G

1.1 Solenoid a (ANSI coil designation see RE 08010) 14 Hand nut, tightening torque MT = 4 Nm [2.95 ft-lbs]
1.2 Solenoid b (ANSI coil designation see RE 08010) 15 Port pattern as per DIN 24340 Form A (without locat-
2 Dimension for solenoid with concealed manual ing bore), or ISO 4401-03-02-0-94, NFPA T3.5.1 MR1
override N9 (standard) – the manual override can only and ANSI B93-7 D03 interface (with locating bore for
be operated at tank pressures up to approx. 50 bar anti-rotation pin ISO 8752-3x8-St, material number
[725 psi]. Use tool R900024923 to prevent damage to R900005694, order separately for …/60 option)
override! 16 Alternative clamping length (Z): 22 mm [0.87 inch]
3 Dimension for solenoid with manual override N
4 Dimension for solenoid without manual override Conduit D box:
7 Cable gland Pg 16 [1/2“ NPT] D or DL Terminal assignment for central connection
8 Angled mating connector (color: red, order separately, – 1 solenoid:
Material number R900005538) Solenoid always to screw terminals 1 and 2,
Ground to screw terminal PE
9 Nameplate
– 2 solenoids:
10 Identical seal rings for ports A, B, P, T
Solenoid on a side to screw terminals 1 and 2,
11 Screw plug for valves with one solenoid Solenoid on b side to screw terminals 3 and 4,
12 Space required to remove mating connector Ground to screw terminal PE
13 Space required to remove coil
Subplates and valve mounting bolts see page 15.
Blocked for new applications / Für Neuanwendung gesperrt
RE 23178/12.05 WE 6 …E Hydraulics Bosch Rexroth AG 15/16

Dimensions

Subplates to data sheet RE 45052 (order separately)


– without locating bore G 341/01 (G1/4)
G 342/01 (G3/8)
G 502/01 (G1/2)
– with locating bore G 341/60 (G1/4)
G 342/60 (G3/8)
G 502/60 (G1/2)
G 341/12 (SAE-6)
G 342/12 (SAE-8)
G 502/12 (SAE-10)

Valve mounting bolts (order separately)


– Clamping length 42 mm:
4 socket head cap screws (SHCS)
ISO 4762 - M5 x 50 - 10.9-flZn-240h-L or 10-24 UNC x 2”
(friction coefficient µtotal = 0.09 to 0.14);
tightening torque MT = 7 Nm [5.2 ft-lbs] ± 10%,
• material number metric R913000064
• material number UNC R978800693
or
4 socket head cap srews (SHCS)
ISO 4762 - M5 x 50 - 10.9
(friction coefficient µtotal = 0.12 to 0.17);
tightening torque MT = 8.1 Nm [6 ft-lbs] ± 10%,

– Clamping length 22 mm:


4 socket head cap screws (SHCS)
ISO 4762 - M5 x 30 - 10.9-flZn-240h-L or 10-24 UNC x 1 1/4”
(friction coefficient µtotal = 0.09 to 0.14);
tightening torque MT = 7 Nm [5.2 ft-lbs] ± 10%,
• material number metric R913000316
• material number UNC R978802879
or
4 socket head cap screws (SHCS)
ISO 4762 - M5 x 30 - 10.9
(friction coefficient µtotal = 0,12 to 0,17);
tightening torque MT = 8.1 Nm [6 ft-lbs] ± 10%
Blocked for new applications / Für Neuanwendung gesperrt
16/16 Bosch Rexroth AG Hydraulics WE 6 …E RE 23178/12.05

Notes

Bosch Rexroth AG © This document, as well as the data, specifications and other
Hydraulics information set forth in it, are the exclusive property of Bosch Rexroth
Zum Eisengießer 1 AG. Without their consent it may not be reproduced or given to third
97816 Lohr am Main, Germany parties.
Phone +49 (0) 93 52 / 18-0 The data specified above only serve to describe the product. No
Fax +49 (0) 93 52 / 18-23 58 statements concerning a certain condition or suitability for a certain
documentation@boschrexroth.de application can be derived from our information. The information given
www.boschrexroth.de does not release the user from the obligation of own judgment and
verification. It must be remembered that our products are subject to a
natural process of wear and aging.

You might also like