Plan showing the Proposed Construction of R.C.C. Roof Ground and First Floor Residential Building in S.F.

No : 146/2A3,Site No:3,
Zaminkottampatti Village & Panchayat, Pollachi Taluk,Coimbatore Dt.
Solar Water Heater
Parapet wall
Weathering course
R.C.C. Roof slab 1:2:4 mix
2'-6" [.76]
4.5" [.11]
Brick work in C.M. 1:6

10'-0" [3.05]

R.C.C. Roof slab 1:2:4 mix

4.5" [.11] Brick work in C.M. 1:6


R.C.C. Lintel 1:2:4 mix
Scale
10'-0" [3.05]
Plan : 1: 100
Site Plan : 1: 200
N
Floor finish
Flooring concrete 1:4:8 mix
Earth filling Area details Sq.ft. Sq.m.
1'-6" [.46] GL GL R.R. masonry 1:7 mix
1'-6" [.46] Area of the site 1202.00 111.67
P.C.C. 1:5:10
1'-6" [.46]
FRONT ELEVATION 9" [.23]
Area of the Pro.Ground floor Building 837.00 77.78
1'-6" [.46]
2'-0" [.61] SECTION ON A-A' Area of the Pro. First Floor Building 618.00 57.43
2'-6" [.76]
Mr.Seakars land

[.61]
2'-0"
3'-0" [.91]
34'-0" [10.36] Area of the Open Space 365.00 33.92
3'-9"
28'-3" [8.61]
[1.14]
28'-3" 28'-3" 2'-0"
[8.61] [8.61] Schedule of Joineries

20'-3" [6.17]
9" 9" 9" 9" Rwh [.61]
9" 10'-0" [.23] 16'-0" [.23] 9" 10'-0" [.23] 16'-0" [.23]
[.23] [3.05] [4.88] [.23] [3.05] [4.88]

28'-3" [8.61]
Pro.Ground & First

36'-0" [10.97]

34'-9" [10.59]
MD Maindoor 3'-3" x 7'-0" (0.99 x 2.13)

PLOT NO:2

PLOT NO:4
W W V V W Floor Building
[.23]

[.23]
9"

9"

D Door 3'-3" x 7'-0" (0.99 x 2.13)


D1
D1 Door 2'-9" x 7'-0" (0.83 x 2.13)
Master Bed Room Toilet Toilet Master Bed Room
[3.05]

[3.05]
10'-0"

10'-0"

Kitchen
10'-0" x 10'-0"
16'-0" x 10'-0" 5'-0" x 10'-0" 4'-7.5" x 10' 16'-0" x 10'-0" 24'-0" [7.32] W Window 4'-0" x 4'-6" (1.21 x 1.37)
A DT ST
A W
W A' W
A' W1 Window 6'-0" x 4'-6" (1.82 x 1.37)
34'-0" [10.37]
V Ventilator 2'-6" x 2'-0" (0.76 x 0.60)
[.23]

[.23]

D1 D
9"

9"

AO AO D1 << 20'-0" WIDE ROAD >>

D
Site boundary
[8.61]

[8.61]
28'-3"

28'-3"

Toilet
W 5'-0" x 7'-0" V
W
SITE PLAN Prop. R.C.C. Building
Hall
Road
[4.88]

[4.88]
16'-0"

16'-0"

16'-9" x 16'-0" Bed Room


D1 D 10'-0" x 16'-0"
Rain Water Pit (Rwh)
Toilet
5'-0" x 8'-6"
Porch
V
8'-0" x 7'-6"

Rain Water Perculation Pit


[.23]

[.23]

MD
9"

9"

W1 W (Not to Scale)
Air Holes
Covering Slab
PRO.GROUND FLOOR PLAN PRO.FIRST FLOOR PLAN
Inlet Applicant.
45 mm Hard

4'0"
SEPTIC TANK WITH DISPERSION TRENCH ( 250 Gls.,) Blue Granite Metal

A.C. Ventilating Shaft

R.C.C Slab, 100 mm Thick 3'0"


Manhole with air tight cover SECTION C-C'
GL Formation Level GL 8'-0"
(Not to Scale)
GL
Inspection Chamber Ventilating hole 1'-0" 6'-0" 1'-0" 4'-0"
Country roofing pantiles extra
U trap large to cover side space 4'-10"
A 2'-0" B
2'-0" C C'
6" S.W. Inlet pipe 150 tk. Outlet Pipe 2'-9"
S.W. Pipe open jointing
and laid to fall 1/100
Dwarf wall 115 tk. Dwarf wall 115 tk. Dispersion Trench
Septic Tank
Brick Work in C.M 1:6
300 tk. Soil encrasing all sides 4.5" 4.5"
1'-0" P.C.C. 1:4:8 1'-0" 11" 6'-0" 11" 1'-0" PLAN
9'-6" SECTION ON - AB 7'-10" PLAN L.B.S/Engineer
Drawn By : CADD TECHNOLOGY, Pollachi. 04259 - 224219