1. PURPOSE
The purpose of this document is to inform the user on the functions of the Field Display Unit for the
Roxar Multiphase Meter
2. ABBREVIATIONS / DEFINITIONS
Roxar MPFM 2600 Roxar Multiphase meter 2600
3. REVISION HISTORY
Revision Description
A New customer documentation
B New template
4. DOCUMENTATION
Note: If the client requires notification before records are discarded, this must be stated on the record itself.
Page 3 of 9
Roxar Template doc. no. / rev.: 034708/D
PO: 4500195123 UM_MPFM-2193-13 ROX000230195/AA
5. PROCEDURE
The enclosure also includes a power supply, computer assembly, barriers to the intrinsically safe
units, converter with galvanic separation, communication switch to peripheral units, and HART
modem.
All wiring and connections to the system should be finalized and checked by authorized Roxar
personnel before external power is applied to the EExd enclosure.
Appendix 1: Well Test Record Sheet may be used to record the measured values.
The electronics components in the flow computer are not repairable and may be subject to
replace. The services should be performed by authorized Roxar personnel only!
5.2 Power – up
The system power is switched ON by setting the changeover switch marked MAIN POWER on the
lower left side of the enclosure (not shown on the picture), to the position marked ON. The system
is switched OFF by setting changeover switch back to the position marked OFF.
Page 4 of 9
Roxar Template doc. no. / rev.: 034708/D
PO: 4500195123 UM_MPFM-2193-13 ROX000230195/AA
5.4 Start – up
Press POWER to activate the local display.
Press MODE until ACTUAL FLOW screen appears.
Run the production flow through the system for at least 15-20 minutes and make sure that there is
no “Process Alarm” or “Technical Alarm”.
Page 5 of 9
Roxar Template doc. no. / rev.: 034708/D
PO: 4500195123 UM_MPFM-2193-13 ROX000230195/AA
Page 6 of 9
Roxar Template doc. no. / rev.: 034708/D
PO: 4500195123 UM_MPFM-2193-13 ROX000230195/AA
5.7 Configuration
5.7.1 Setup by using Service Console Software
Well identification and the fluid parameter setup should be completed using the Service Console
Software.
All of the wells should be named with a number between 1 and 50. Alphanumeric characters
cannot be used.
The flow computer can store up to five (5) different fluid parameter sets (PVT data and fluid
properties). The fluid parameter set that is used during a well test must be pre-selected [2].
Page 7 of 9
Roxar Template doc. no. / rev.: 034708/D
PO: 4500195123 UM_MPFM-2193-13 ROX000230195/AA
If the push button is not activated within 15 seconds, the display will exit to the
default menu “ACTUAL FLOW”
Press PAGE five (5) times to display the WELL TEST MENU.
Press MODE to toggle between standard and actual conditions.
Press AUX2 to start new well test. The NEW WELL TEST menu will appear.
Press AUX1 to change setup. The WELL TEST SETUP menu will appear.
Press AUX1 to change well number. The WELL NUMBER SELECTION menu will appear.
Press AUX1 or AUX2 to increase or decrease the well that is to be tested, respectively.
Press PAGE to return to the WELL TEST SETUP menu.
Press AUX2 to change well test duration. The WELL TEST DURATION menu will appear.
Press AUX1 or AUX2 to decrease or increase the selected well test duration, respectively.
When starting a well test from the field display, the well number and the corresponding fluid
parameter set will then automatically be loaded from the pre-selected list into the flow computer.
Press PAGE five (5) times to display the WELL TEST MENU.
Press AUX2 to start new well test. The NEW WELL TEST menu will appear.
Press AUX2 two (2) times to start well testing. WELL TEST IN PROGRESS will be displayed.
The well identification number, test duration, remaining time, and measured values will be
displayed along with options to STOP and Escape.
Page 8 of 9
Roxar Template doc. no. / rev.: 034708/D
PO: 4500195123 UM_MPFM-2193-13 ROX000230195/AA
WELLTEST
PAGE =
WELLTEST
If you really want to START a
AUX1 = Change well
Press AUX2
AUX2 Change
PAGE =
PAGE =
8
If you really want to STOP
press AUX2
PAGE =
Page 9 of 9
Roxar Template doc. no. / rev.: 034708/D