03 Vibrating Drum Training
03 Vibrating Drum Training
Yang Yi
Content
Maintenance
Troubleshoot
Introduction
The vibrating drum is the core part of the vibration roller, it is not
only the working equipment, also the traveling device of the roller.
The vibrating drum is used for generating the vibration force and
project.
Working principle
Vibratory drum function: centrifugal force and front drum load
generated dynamic linear and static linear pressure to compacting job
object.
2. Mass of vibration (kg) : Including mass of drum, vibrating exciter, hydraulic motor,
connect plate etc.
3. Front Drum Static Linear Load (N/cm): weight of the drum on linear transmitted to the
ground.
4. Nominal Amplitude (mm): design amplitude, the vertical distance of drum travel,
caused by the motion of the eccentric weight inside the drum.
Notice: working amplitude more than nominal amplitude when roller at working.
SLOW FAST
Vibrating Drum
key parameter
Amplitude
The vertical distance of drum travel, caused by the motion of the eccentric
weight inside the drum.
Rotating eccentric block to clockwise or anticlockwise direction to achieve
high or low amplitude.
AMPLITUDE
2mm
High amplitude
Low amplitude
Model Advantage Defect
1. At starting or stop vibrating
stage has impact,
1. Constant centrifugal force decrease eccentric shaft
Eccentric calculability; and vibratory bearing life.
Block
2. Easy for manufacture; 2. The vibration curve not
stable, poor compaction
performance
1. No impact at starting or stop
vibrating stage, increase eccentric
Eccentric shaft and vibratory bearing life. 1. Centrifugal force not
Block with constant.
2. The vibration curve is smooth and
Steel ball stable, compaction performance 2. Manufacturing complex.
better.
Structure of Vibrating Drum
Eccentric block
Roller
Damper
Connecting Traveling
plate bearing
Middle shaft
Vibratory Vibratory
with fan
housing bearing
Structure of Vibrating Drum
Eccentric block
with steel ball
Roller
Damper
Connecting
plate Traveling
bearing
1. Spline shaft
2. Vibratory bearing
3. Housing
4. Eccentric block
5. Plug
6. O ring
7. Cover
8. Spline shaft
Structure of Vibrating Drum
What different?
Structure of Vibrating Drum
Eccentric block
26
Troubleshoot of vibratory drum
Issue Issue Root Solution
1 Vibratory Oil of vibratory Check oil level and fill to
bearing housing too less standard
overheat Oil of vibratory Check oil level and drain to
housing too more standard
Vibratory bearing Adjust clearance.
clearance too big
2 Frequency Oil of vibratory Check oil level and drain to
lower than housing too more standard
standard Vibratory hydraulic Check and adjustment.
system setting
pressure too low
Vibratory pump or Check and replace.
motor has
bypassed.
Troubleshoot of vibratory drum
Issue Issue Root Solution
3 Drum not Spline shaft or internal Check and replace.
vibrate spline sleeve damage and
slipped.
Vibratory hydraulic system Check system pressure and
not working. flow, try to find problem on
pump or motor, adjustment or
replace.
Vibratory control electronic Check system fuse, relay and
system not working solenoid.
4 Leakage Axial seal of vibratory Check system pressure and
motor damage, hydraulic seal of motor, replace it.
oil leak to vibratory
housing and through hole
of shaft to drum.
Seal of vibratory housing Check and replace seal.
damage and oil level lower
than standard.
THANK YOU