You are on page 1of 3

Conbextra EP65 constructive solutions

Free flowing epoxy resin grout


Exotherm
Uses
Conbextra EP65 epoxy systems will develop an increase in
Suitable for use in situations where heavy dynamic or mobile temperature on mixing. Its extent will be a function of the
loads are encountered. The gap between a base plate and volume to surface ratio, the ambient temperature as well as
substrate will need to be filled in such applications as the mass and thermal conductivity of the surrounding
reciprocating machinery, testing equipment, heavy crane and materials. Contact Fosroc for specific data on the product.
transporters rails, high speed turbines, centrifuges and drop
forges. Typical on-plate shutter system
Also for use in conditions where chemical spillage may be Removable hopper: For larger pours the grout may be
encountered. Typical situations could be met in steelworks, hand placed or pumped into a removable hopper (trough).
refineries, electroplating works and chemical plants.

Advantages
 Suitable to fill gaps from 35 mm to 65 mm.

 Low creep characteristics under sustained loading.

 Resistant to repetitive dynamic loads.

 Non-shrink and hence ensures complete surface contact


and bond.

 High compressive, tensile and flexural strengths.

 Withstands a wide range of chemicals.

 Low exotherm epoxy grout .

Technical Support
Fosroc offers a comprehensive range of high performance,
high quality construction products. Fosroc offers a technical Specification clauses
support package to specifiers and contractors as well as
technical advice from staff with unrivalled experience in the Supplier Specification
industry. All epoxy resin grouting where shown on the drawings,
must be carried out using Conbextra EP65 product
Description manufactured by Fosroc and used in accordance with the
manufacturer’s data sheet.
Conbextra EP65 range of epoxy resin based products is
designed for free-flow grouting of gaps from approximately 35 Limitations
- 65 mm. Where higher thicknesses are involved please
consult your local Fosroc office i.e. base plate plinths, etc. Failure to comply may lead to
crack development in the grout.
Conbextra EP65 three component systems consisting of
base resin, liquid hardener and specially graded inert fillers o
Conbextra EP65, at temperatures below 20 C the cure rate
are supplied in the correct mix proportions designed for may be slow, but will go to completion provided the
whole pack mixing on site and no other materials should be o
temperature remains above 5 C.
added.
Careful planning of shuttering should be made to reduce
Chemical Resistance exposed surfaces of epoxy grout and shoulders to an
absolute minimum. Exposure to cyclic temperature
Conbextra EP65 product is resistant to oil, grease, fats, most changes is likely to cause cracking and peeling in
chemicals, mild acids and alkalis, fresh and sea water. unrestrained grout. Please contact Fosroc for further
Consult Fosroc’s Technical Department when exposure to details.
solvents or concentrated chemicals is anticipated.
Properties

Page 1
Conbextra EP65
Test Method Typical Mixing
Results
3
Density (kg/m ) 2050 Pour all the contents of the hardener pack into the base
o
Compressive strength @ 40 C container. Mix using a slow speed power mixer until
2
(N/mm ) ASTM C579: homogeneous.
3 days 91
7 days 99 Pour all the mixed liquid into a container then add all the
28 days 105 filler gradually. Mix using a slow speed power mixer for two
2 minutes or until a uniform colour is achieved in the grout.
Tensile strength (N/mm )
ASTM C307, 7 days: 15
Flexural strength (N/mm )
2 Placing
ASTM C580, 7 days: 25
Modulus of elasticity The mixed grout should be poured steadily from one side
2
(KN/mm ) ASTM C580, 7 days: 15.0 only to eliminate the entrapment of air.
Linear shrinkage (%)
ASTM C531, 7 days: 0.08 Continuous grout flow is essential.
Linear coefficient of thermal
-6 o Sufficient grout must be available prior to starting.
expansion 10 (mm/mm C)
ASTM C531: 42
The time taken to pour a batch should be regulated to the
Linear shrinkage of cured material
time taken to prepare the next batch.
ASTM D2566: 0.0002
o
Pot life at 40 C ASTM D2471 (min): 80 Flow Characteristics
Peak exothermic temperature
o
at 40 C (ASTM D2471): 37 The maximum distance of flow is governed by the gap
Water absorption (%) thickness, the head of grout applied and the ambient
ASTM C413: 0.14 temperature. The following table gives typical data for flow
design.
Application Instructions
Gap thickness Hydrostatic Maximum
o
Preparation C (mm) head (mm) flow (mm)
35 35 100 1200
Foundation surface 35 70 100 2000

All contact surfaces must be free from oil, grease, free Cleaning
standing water or any loosely adherent material. Concrete
surfaces should be cut back to a sound base. All dust All tools and equipment should be cleaned immediately
must be removed and bolt-holes or fixing pockets blown after use with Fosroc Solvent 102. Spillages should be
clean of any dirt or debris. absorbed with sand or sawdust and disposed in
accordance with local regulations.
Steel surfaces
Estimating
All steel surfaces should be shot blasted free of rust and flaky
mill scale 2½. Cleaned surfaces may be protected by the Supply Yield
application of Nitoprime 28. Conbextra EP65: 16 kg 8 litres
92 kg 46 litres
Formwork
Bulk packaging is available.
The formwork should be constructed to be leakproof as
Conbextra EP65 product is free flowing grouts. Loss of grout Storage
once the material is placed, but not hardened, will result in
incomplete filling of the gap. Conbextra EP65 product has a shelf life of 12 months if kept
o
in dry conditions at 25 C.
For free flow grout conditions it is essential to provide a
hydrostatic head of grout. To achieve this a feeding hopper
system should be used.

For deep section placing in inaccessible, extended widths


chains may be used to encourage lateral movement and
complete filling of the gap, thus eliminating air pockets. For
further information please contact Fosroc for specific advice.

constructive solutions Page 2


Conbextra EP65
Precautions Additional Information

Conbextra EP65 Contains resins which may cause Fosroc manufactures a wide range of products specifically
sensitisation by skin contact. Avoid contact with skin and designed for the repair and refurbishment of damaged
eyes and inhalation of vapour. Wear suitable protective reinforced concrete. This includes hand-placed and spray
clothing, gloves and eye/face protection. Barrier creams grade mortars, fluid micro-concretes, chemical resistant
provide additional skin protection. Should accidental skin epoxy mortars and a comprehensive package of protective
contact occur, remove immediately with a resin removing coatings. In addition, a wide range of complementary
cream, followed by soap and water. Do not use solvent. In products is available. This includes joint sealants,
case of contact with eyes, rinse immediately with plenty of waterproofing membranes, grouting, anchoring and
clean water and seek medical advice. If swallowed seek specialised flooring materials.
medical attention immediately. Do not induce vomiting.
o
Fosroc Solvent 102 Flammable liquid. Flash point 33 C. Fosroc has produced several educational training videos
with provide more details about the mechanisms which
Keep away from sources of ignition - non smoking. Wear cause corrosion within reinforced concrete structures and
suitable protective clothing, gloves and eye/face protection. the solutions which are available to arrest or retard these
Use only in well ventilated area. destructive mechanisms. Further information is available
from the publication: ‘Concrete repair and Protection - The
For additional information see relevant Material Safety Data Systematic Approach’, available in seven language formats.
Sheet.
For further information about products, training videos or
Fire publications, contact the local Fosroc office.

Fosroc Solvent 102 is flammable. In the event of fire


extinguish with CO 2 or foam.

Important note:
Fosroc products are guaranteed against defective materials and manufacture and are sold subject to its standard Conditions
for the Supply of Goods and Services, copies of which may be obtained on request. Whilst Fosroc endeavours to ensure that
any advice, recommendation, specification of information it may give is accurate and correct, it cannot, because it has no direct
or continuous control over where or how its products are applied, accept any liability either directly or indirectly arising from the
use of its products, whether or not in accordance with any advice, specification, recommendation of information given by it.

Fosam Company Limited


Head Office Telephone: +966 2 637 5345 Fax: +966 2 637 5891 email: fosam@fosroc.com
Post Box 11081 Regional Offices
Jeddah – 21453 Jeddah Sales Office Tel: (02) 608 0999 Fax: (02) 638 0693 Yanbu Tel: (04) 322 4280 Fax: (04) 391 2980
Jeddah Showroom Tel: (02) 665 0187 Fax: (02) 667 4844 Makkah Tel: (02) 542 0869 Fax: (02) 542 0869
Saudi Arabia Riyadh Tel: (01) 482 9303 Fax: (01) 482 7562 Medinah Tel: (04) 855 0091 Fax: (04) 855 0047
Dammam Tel: (03) 814 1282 Fax: (03) 814 1581 Jubail Tel: (03) 362 3904 Fax: (03) 362 3875
www.fosroc.com Khamis Mushayt Tel: (07) 250 0469 Fax: (07) 250 0469 CSD Tel: (02) 608 0999 Fax: (02) 638 0693

Registered Office: Industrial Area, Phase 4, Road No. 414, Street No. 407
Page 3 FO SA/CONBEXTRA EP65/05/A

You might also like