Professional Documents
Culture Documents
CBI123A •
•
Input: Single-phase 115 - 277 VAC
Output Load: power supply 12 VDC; 3 A
• Output: Battery charging 12 VDC; 3 A
DC UPS • Suited for the following battery types:
Open Lead Acid, Sealed Lead Acid, lead Gel and Ni-Cd (option)
• Automatic diagnostic of battery status.
• Switching technology, output voltage 10-14.4 VDC
• Three charging levels: Boost, trickle and recovery
• Protection degree IP20 - DIN rail mountable
Output Current In
Output Voltage (Vn) / Nominal Current (In) 12 VDC / 3A
3A
Efficiency (at 50% of rated current) ≥ 90 %
Turn-On delay after applying input voltage 1 sec. (max)
Start up with Strong Load (capacitive load) Yes, Unlimited
Dissipation power load max 9W
PROTECTION
Short-circuit protection Yes
Over Load protection Yes
Over Voltage Output protection Yes (typ. 35 VDC)
LOAD Over Temperature protection Yes
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
142
CBI123A
DC UPS
Jumper for Battery Type Selection
The Altech DC-UPS system is built to optimize power
management. The available power is automatically allocated Open
between load and battery, supplying power to the load is the first Lead
1 2 3 4 6 7
priority. For high inrush applications the charging power will Sealed
reroute automatically to the load. In this case the maximum Lead Low
available current on the load output is two times the value of the 1 2 3 4 6 7 1 2 3 4 5 6 7 8 9 10
Sealed – + – +
device rated current.
Lead High
1 2 3 4 6 7 ADJ. MAINS LOW BATTERY
OR OR BATTERY
The Battery Care concept based on algorithms that achieve rapid Gel BACKUP REPLACEMENT
Time Auto-diagnostic system, monitors battery faults, sulfated Gel LOW BATTERY
OR BATTERY
Battery (1) REPLACEMENT
battery, short circuit battery elements, reverse polarity connection, 1 2 3 4 6 7 DIAGNOSIS
battery disconnect. This conditions are detected and identified by NiCd - BATTERY
the number of blinks of the diagnosis Led. NiMh (1) START
1 2 3 4 6 7
L N
Signal Output Contacts Jumper for Functional Setting
Main or Backup Power Yes
Battery Life
Battery Power Low Yes
Test On1
Battery Fault Yes 1 2 3 4 6 7 1
Max. Current Rating (Resistive Load) 1A 30 VDC/60 VAC Jumper present: life test enabled.
Fast Charge 2
Jumper present: fast test enabled.
Minimum Permissible Current Rating 1mA @ 5 VDC Enable2
3
Jumper present: fast recovery charge
1 2 3 4 6 7 enabled only for size 3. Possibility to
RJ45 Connection Input / Output Fast Recovery
recharge the battery also when the
voltage is close to zero with the
Temp. Comp. Battery (with ext. probe) Yes - Optional Charge (2)3 maximum power of the device.
Remote monitoring display Yes - Optional 1 2 3 4 6 7
Can Bus No
Environment
Insulation voltage (IN/OUT) 3000 VAC
Insulation voltage (input / ground) 1605 VAC
Out 1
Insulation voltage (Output / ground)
Protection Class (EN/IEC 60529)
500 VAC
IP20
In Vac CBI Load
Pollution Degree Environment 2
Battery Mains or Backup
Connection TB, Screw Terminal 2,5 mm² (24–14AWG) Out 2
Protection class (Ground Connected) Class I
Dimensions (WxHxD) 65x115x135 mm Battery Low or
2.56x4.53x5.32 in Battery Replacement
Weight (approx.) 0.6 kg (1.35 Lbs)
A compact and rugged metal case with DIN rail mounting bracket
provide an easy installation and an IP20 protection.
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490
143