Professional Documents
Culture Documents
Sas22 37SD 5e 6e (E7) (39600 12940)
Sas22 37SD 5e 6e (E7) (39600 12940)
eS . Press the dryer advance operation button “1” 2 bei ae Indication lamp goes on. = tite one © Inorder to stop dryer advance operation mode, f ] A: ME Ale re, press again the button of dryer advance 8 ta see ch l RATION HR Ge operation mode, © When the dryer advance operation is not in use, the machine and dryer start at the same time. °° or 4 ef exe fn ize © When stopping dryer advance operation mode | ein | ||) Si during dryer advance operation, at the time, : machine starts. tS : l 4 2 8 ANTOBASE- Operation mode selection switch 3.3.2. Low pressure operation (2 stages pressures selection function) By switching low-pressure operation signal (ADT), 2 stages pressures are available, Low pressure operation in the period during wl .e discharge pressure caused due to fall of pressure | © In the period during which the discharge p» fone wauee is allowed to remain at a low level, including between 0.02 to 0.2 MPa. during nighttime hours. z Selection of service machine and stand-by machine. Two machines are operated alternately. Service pressure il Operation procedures [Operation at operation panel] User wiring part --~]Press low pressure operation button “2” Indicator light goes on and low-pressure operation starts @® In order to stop low pressure operation, press low pressure operation button again. ‘Lowpressue | ADT _{operaton signal! Low pressure at ON [Operation at exterior signal] EXCR: Remote operstion signal (DC12ViemA) © In the case of operation by exterior signal, perform ADT : Low pressure operation signal (OC 12V/6mA) cable connection as shown in the figure on the le . ee using a terminal plate (B10) provided in the A120876E | starter panel © Pressing “ON” low-pressure operation signal (ADT), low-pressure operation is selected. 3 For the adjustment of low pressure operation caused due to fall of pressure, please refer 5.6 clause, 353. Operation 3.3.3. Automatic start/Stop (auto-start/Stop) operation When this machine is started, it starts to first remove condensate. And then it is automatically started and stopped, according to increase or decrease of air consumption, Thus power saving is accomplished. © Operation for removal of condensate Depending on ambient temperature, when the discharge air temperature exceeds the dew point temperature in the figure on the left, and when 5 integrated minutes or longer of purge operation elapse, the condensate that is caused at start-up will completely be removed and emulsification of compressor oil will be prevented. This can cause the operation for removal of condensate to become shorter and to prevent frequent start/stop of the machine operation. Relation between ambient temperature ‘and dew point (based on humidity 80%) \ Dew point temp. (C) 1 20 3 40 Ambient temp. (C) © Start/stop mode operation After completion of condensate removal operation when starting, the machine will automatically stop in the case enough stop time can be estimated upon pressure drop gradient when unloading. ‘The same way applied to the case unload time continues for the fixed time (J) (60 seconds but can be changed). The machine will restart in the case service pressure drops to full road recovering pressure (purge cancellation pressure) (PL) and meet the following conditions (1) or (2). () 20 seconds or more has elapsed after stoppage and separator receiver tank’s residual pressure drops to 0.1MPa or less (2) 90 seconds or more has elapsed after stoppage. tis possible to change estimated stop time, refer to 5.6. Pressureincrease operation The predicted stop time will be recalculated Unloading operation staring pressure (purge stating pressure) (PH) Restart (Resta wltake place ar he service pressure ‘ecipases below the Wl fad recovery pressure) (' __Fulload recovery pressure (urge cancelation pressure) (PL) |} —Sepertor cee tank pressixe [Wen te separator recover tani readual pressure is 0.1 MPa ores, resto Is omeah- [pefored detecion te current pressure a = Operation for removal oteondensate edited stop time (60 sec.changeable) ‘Start inerock time 20 sec. fired. The resiced stop time is calelated from the pressure drop line, Predicted top tine < Predicted stop time determined. ‘Alter the prassue increase operation, the system wil ‘hit the stop mode operation to save its power consumption. 1708526 1.Operation procedures Press auto start/stop button “3”, Indicator light goes on. © In order to stop auto start/stop operation, press auto start/stop button again. Releasing auto start/stop mode even while it stops in this mode, this made will be switched to continuous operation mode. But it keeps stopping til the service pressure drops to re-start, and when it drops to re-start pressure, it starts operation again.3. Operation © As during automatic start-stop operation the compressor is designed automatically to start or stop corresponding to the air ‘consumption, keep your hands away from the interior of the machine even ifit keeps stopping K0028 3.3.4 Remote control 1. Wiring work of remote control switch ‘Remote operation terminal board (TB10) is provided inside the starting panel. If you wish to operate this machine remotely please prepare power, pilot lamp (PL), switch (EX-R,ADT) and wiring as the drawing below. Power should be turned*OFF” when wiring. (ro User wiring part --> 2 OI x +. + Ameen eae Terminal plate as | for remote control wanes eae (B10) ‘A1206776-4 EX:R: Remote operation signal (OC 12V/6mA) —_ ‘ADT : Low pressure operation signal (DC12V/6mA) ‘Terminal plate arrangement PL: pilot lamp Atzo7tt © Operation pilot lamp : Lamp goes on when the compressor starts. Abnormal pilot lamp : Light up when stop under abnormal condition, Warning pilot lamp?Light up when warning of abnormal condition appears. © Remote operation selected pilot lamp : Lamp goes on when remote control operation is selected % Indication signal is no-voltage with contact (RY5,RY6,RY7,RY8) [Contact capacity: -AC250V LOA %* Connecting cable size of remote control terminal plate‘[Applicable cable---0.08-2.5mm?] 2. Operation procedures © Press the remote control button “4”. Indication lamp goes on. @® Machine runs when remote operation signal (EX-R) is “ON” and stops when this signal is © In order to release remote operation, press again remote control mode button. Even while remote control mode operation continues. itis possible to stop operation, using stop button provided on the operation panel. ‘OFF’. nth the remote control mode is released: operation by machine side will be selected.) © Once the machine stopped at the emergency stop during remot tion mode then it can not be temotely reset. Pl forth f trouble at th ion panel and repair it, Then 1¢ operation b resetti 2 When using remote operation please surely follow the order above for operation. Any misoperation might keep the machine from regular running or sudden g © In remote control operation, the machine can be started by : remote control far from it even while the machine is in a = shutdown state. Therefore, do not put your hands inside the = machine. < © Make sure that the power is “OFF” before performing PK0028 inspection/maintenance. a73. Operation 3.3.5 Momentary stop restart operation When the machine stops by momentary power supply interruption and if it is about 2.5 to 4 seconds, the compressor automatically restarts its operation about 30 seconds after the power recovery. Interruption 25.00 dee —— Dea Power recovery fom {ogee i Flickers Glows Start lamp 1 ee Restart Airend \ AITOB4E-1 t The start lamp flickers on i ‘ while waiting for restart time. D: i | Restart yer ' : When re-starting the machine, start it at the : same time of starting compressor operation 30sec) without dryer advance operation. ‘81003186 The factory default setting has been made in such a way that the machine operation will resume automatically at the time of power return. If such a setting that prevents automatic restart is desired, that setting can be established by modifying the internal setting of the controller. For the details, contact our office nearby or distributor. © When the machine is stopped due to instantaneous power supply interruption, machine is automatically restarted after the power is supplied again. ‘Therefore, do not put your hands inside the machine. (© Make sure that the power is "OFF" before doing wiring work. AXWarninc4. Failure and Troubleshooting 4.1 Warning: Abnormality display 4.1.4. Details of warning and abnormality indication [Warning Display] When ever a little abnormality occurs during operation, the operation continues. When error code lamp flashes, rapidly take the following countermeasures and correct it soon. Tem Fale coi ‘Trouble ‘Measures DISCHARGE AIR ‘TEMPERATURE H When air temperature at outlet of compressor air end exceeds 105, it Tower ambient temperature, (ower than 40°C) Check compressor ol level ‘Check and change oil iter. Adjust service pressure to proper one. Cleaning cil cooler. Cleaning dustproof air filter. AIR FILTER CLOGGING. When differential pressure reaches 6.2kPa due to air filter clogging, a ‘warning is indicated. (It continues longer than 10 seconds.) Clean or change WARNING: DRYER Eat When abnormality occurs at dryer, it displays emergency Tower ambient temperature Check dryer. INTAKE ATR ‘TEMPERATURE HIGH) When ambient temperature reaches 52C, it warns, Lower ambient temperature. DISCHARGE AIR ‘TEMPERATURE HE When air temperature at outlet of compressor air end reaches 108, it Same as the countermeasures for failure code AL ‘SEPARATOR DISCHARGE AIR TEMPERATURE _H When air temperature at outlet of separator exceeds 105°, it warns, Faulty separator element. ‘Change oil separator element and compressor oil ‘MAINTENANCE WARNING 342 ‘When operation time reaches set time, it warns, Do maintenance in accordance with the table of Periodical Inspection and ‘Maintenance.4. Failure and Troubleshooting [Abnormality Display] When ever abnormality occurs during operation, each lamp goes on and it makes emergency stop. When error code lamp flashes, take the following countermeasures soon and repair it.try to operate the machine. DISCHARGE AIR TEMPERATURE B ‘Trouble Measures When discharge air temperature at outlet of compressor air-end reaches 10, it warns. Tower ambient temperature (ower than 40°C) Check compressor cil level Check and change oil filter. Adjust service pressure to proper one Cleaning oil cooler. Cleaning dustproof air fer. REVERSE PHASE ‘CONNECTION When power supply is connected in reverse phase, it displays emergency Change connection between R and T phase. Switch the R-T phase of power supply. ‘ABNORMALITY: DRYER 341 ‘When abnormality occurs at dryer, it displays emergency. Tower ambient temperature Check dryer. OVERLOAD When main motor gets overloaded, it displays emergency. ‘Check service pressure ‘Check and confirm voltage of power supply. ‘Chock thermal relay. When will display when an error cecurs in the fan motor inverter and when the fan motor is overloaded. ‘Check fan motor. When want to see the error of fan motor inverter. ‘Cheek and confirm voltage of power suppl SEPARATOR DISCHARGE AIR TEMPERATURE _E. When temperature of air discharged at outlet of separator exceeds 110C, it displays emergency Faulty separator element. ‘Change oil separator element and compressor ol, DISCONNECTION. OF DISCHARGE AIR TEMPERATURE SENSOR When the discharge air temperature sensor hecomes disconnected, it displays an abnormality. DISCONNECTION OF SEPARATOR DISCHARGE AIR ‘TEMPERATURE SENSOR When the separator exit temperature sensor gets disconnected, it displays abnormality. ‘Check cable and connector for any faulty contact, and also check for any disconnection. EMERGENCY STOP DUETO EXCESSIVE RISE OF DISCHARGE ‘TEMPERATURE When discharge air temperature at outlet of compressor air‘end reaches 120°, it warns, Same as the countermeasures for failure code E+ INTAKE TENP. SENSOR DISCONNECTED When ambient temperature sensor is disconnected, it warns, ‘Check cable and connector for any faulty contact, and also check for any disconnection,4, Failure and Troubleshooting Reset © If switch is pressed while failure code lamp is flickering, it displays failure code. ‘And if itis pressed longer, its display is reset. 31: When an abnormality occurs at a dryer prior to delivery ex.works, it is set to display “Abnormality”. If you wish to continue operating the machine even when a fault occurs in the dryer, such operation is made available using the data setting switch on the operation panel. For the details, contact our office nearby or distributor. 32: When the maintenance warning A-8 appears, it cannot be reset if the maintenance time is “0” On this occasion, please reenter maintenance time. Refer to 5.6 for details of reenter method. 4.2. Troubleshooting © Should any trouble occur during operation, do not leave it. Investigate the cause and take appropriate measures. © in this chapter the most important troubles, causes and countermeasures are described. For such items or parts marked ©, contact our office nearby or distributor because technical knowledge is required, 4.2.1 Compressor Trouble status Cause Countermeasures = T) Malfunction of pressure sensor. Check 9 3 @) Airleak from unloader system piping. | Check/repair © 3| (3) Trouble of safety valve Change ba (It blows below the set pressure.) | Unloader does not (4) Trouble of solenoid valve for capacity | Check/repair ° | operate and safety control (SV1). Wrong cable connection 3| valve blows and faulty contact. a (6) Defective seating face failure of Disassemble/repair | © 2 unloader valve 2 (6) Defect of oil seal. Disassemble/check © é () Malfunction of controller. Check/change _ © ‘1D Separator oil scavenging orifice Disassemble/check clogging. Oil is mixed in (2) Discharge pressure is low. Check pressure © discharged air (Much control valve. oil is consumed) (3) Deterioration of oil separator element. | Check/change ® @) Oil level is too high. Drain excessive oil | See5.4.8 ‘to proper level. ‘Abnormal noise from | (I) Belt slipping. Check belt, or Seeb.7 belt: change. Frequently () Air leakage from pipes. ‘Check compressor starts and | (2) Malfunction of pressure control valve _| Check/change | stops automatically seat. | even when | compressed air is not = | consumed. 2) Even when each (WD) Defective connection of switch Gheckichange © S| switch is pushed ON, } (2) Malfunction of controller. Check/repair ° machine will not run, No abnormality lamp_ J © Malfunction of controller is caused by | Uso a power source clr bat the " the source of the machine often stops ae with unknown cause. | (9) yfalfunction of controller Check/change © Start lamp glows, but | (1) electromagnetic switch failure Checkichange ® very (2) Malfunction of controller. Cheek/change ° Oil leaks from oil seal . portion, () Damage of oil seal Check/change ° +34. Failure and Troubleshooting 4.2.2. Dryer ‘Trouble status Cause Countermeasures | Remarks (No power supplied. Checkirepair (2) Breaking, or disconnecting of wire. | Check/repair (3) Abnormality of power supply voltage. | Adjust to rated voltage ae (4) Malfunction of refrigerating Cheek/ehange compressor. (6) Malfunction of electromagnetic Checl/ehange e switeh, (@) Thermal relay activates. Check/change e (7) High pressure switch malfunction. _ | Check/change ® (W Drain pipe broken or clogged. Checkirepair (2) The solenoid valve for draining Melt frozen parts ® condensate (SV6) is frozen. (8) Cable disconnection in line to solenoid valve for draining condensate (SV6). and drain them. Wrap the valve with freezing protection band. Repair ae (@) Malfunction of the capacity control | Check/maintenance | @ water dupa at quiet valve (Inside of the heat exchanger is frozen) (6) The open air temperature is lower | Wrap piping with © than the dew-point temperature. _| heat insulation material © Cooling capacity drops. Check coolant leak. | © (7) Ambient temperature is too high. | Lower ambient temperature. (6) Fins of condenser clogged. Clean condenser (9) Filter of dustproof clogged. Check/clean See5.4.1 @ Ambient temperature is high. Make it lower than 40. (2) Abnormality of power supply voltage. | Adjust to rated It starts, but stops soon. voltage. (8) Malfunction of electromagnetic Check/change © switch, (W) High pressure switch malfunction. _| Checkichange e @) Foreign matter stuck in seating face | Change’ clean © Air is blowing from drain outlet, of solenoid valve for draining condensate (SV6).. AAWARNING © Nonfiammable, innoxious and odorless refrigerant (Freon gas) is used for dryer. ‘Should this gas leak from this machine and contact fire, noxious gas will be caused and it can sometimes cause stimulus to eyes and throat. Further, as the gravity of this gas is heavier than air, it covers surroundings floor space and it could cause ‘oxygen deficient situations. In case this gas should leak. stop using fire, and ve the surroundings by sweeping the floor. And contact our office nearby or distributor. 445. Periodic Inspection List 5.1 Precautions on Periodic Inspection/Maintenance The following table shows the inspection and maintenance intervals under normal operation conditions. When used or operated under hard environmental conditions, it is impossible to warrant, the machine even if the above conditions are performed according to the intervals listed in the above table. AXWarninc © Before inspection, be sure to turn the power “OFF” and hang up a "Now Checking and Maintenance" tag in front of the switch, Accidental turning on of the power can cause an electric shock accident, or even a fire due to short-circuit. © Keep the electric components away from water or steam. Otherwise, electric shock accident or short circuit could Syoot_] cause fire. IMPORTANT, © Be sure to use recommended oil and grease. © Use genuine parts for replacement. © Never disassemble or readjust the components like motor and compressor air-end because such things are not mentioned in this manual. Ask our office nearby or distributor for detail if such work is needed. © Never make any modification to the machine without prior approval. © Any breakdown, caused by using unapproved parts or by wrong handling, will be out of the scope of "WARRANTY". © Place a container or a pan underneath the oil port to receive waste liquid so that such liquid cannot be spilt out on the floor or inside the machine. © The pressure displayed on the operation panel shows the service pressure, Aso, a pressure gauge is mounted in the lower area of the oil separator tank, through hich the pressure in the tank can be checked. For periodic inspection, wait for ‘enough time (2 - 3 minutes) after stopping the machine. Then start inspection job, © Dispose of the waste fluid properly. Do not dispose of such harmful fluids to the ground, rivers, lakes or ponds, and sea. Doing so contaminates the environment. it should be noted especially that unauthorized disposal of the oil, solvent, fiters, and other toxic substances is subject to punishment. 5.2 Easy inspection of the dryer IMPORTANT, © For prevention of leak of refrigerant from dryer, it is necessary to perform dryer ‘easy inspection more times than 1 time every 3 months. (1)Check the dryer for abnormal noise. (2) Check for any corroded refrigerant pipe or leak of refrigerant and the ike an also for oil oozing, (3)Check for frost sticking to radiator. »Should refrigerant leak, immediately take action for reparation a15. Periodic Inspection List Inspection List Periodical Inspection and maintenance (A) In case that total operation hours per one y r are less than 3,000 hours [A Itreters tothe inspection tems of dyer Maintenance nial lspecion tems Inspection pits] > J Brey | Evy | fey | Ey] Bey] — Remats [page iY | month | + year | 2years | 4years | 6years | 8 years Indication of each gauge ° ‘Sees wnebod bees Compressor oil level | Check ° fee oes a2 Som Retigeantresie Oat ou Ape gauge A | Chock 2 SRE ROSE ih inthe| a 5 rie 00a sa aT eae drain, en ery ee cs Dusprocfarfier [hea raean | _O % Trea ety ave perormance ° 56 Airfter element Clean [e} 57 Status confirmation oF seoneratsrina | | can ffancesage. "|e portion of dryer drain Gear ezrin Dustproof air iter Change ° 56 ‘Scavenging orifice strainer | Clean e 56 Swen cca org_| check e Fecae BER 55 Wrens pany srosza fn chek ean . Saned ceentes | 57 sooras ole Be Paley Chad e Hatrom epee | 58 Fuerte heck e ne heck e Colatmainmatee | Rt e ape Tuten ee an THE a Clef tan noir oe e enna Feninene che den ° Air filter element ‘Change ° 57 Compressor ot Charge 40 sit Oil fiter ‘Check ! change e 57 O-ring of ol filer Change e 51 ll separator element Change e Sz ‘Nylon tube Change e Wane aay tense cooler | clean . stated, dean tas somes posite tien sev Oil level gauge ‘Change e ‘stained, change it as somnas posse Coninoretayer [A [olan ° env ot eb Dryer fan mator ‘A | Check e Bering ofmainmatee | Change e Teamabe ater chek Bergetfan not —_| Change ° a5. Periodic Inspection List T Tariana inspeion ems npecon ins) IFT every | Ermey | Evy | Ey | Bey] Rerarts [Pap a | mann | year | 2 years | yeas | yeas |ayears Oi seal To conpresser aivend ; iene . Consumable pa unloader Change © Consumable part Saat compeneis vecumreiefvave | Stange : loser Rubber hse Change . og Consumable patot | Check chang | e pressure contol vave | Fiston . Reais ar choc heck’ change | nama Qasarp arene t ae Searle sarge at usable ate heck, temp. Ambient temp, | "#0 . inomal sensor Sokol ave charge Fea Replace the ply, Bet Change oni” | 58 E cnetens Compressor] a [change Ro-able aor hea feeang yer roma Fan contol pressure Reusable oer oo, swichfocdyer | A J Change noma Cobar toro seal ior | Check ircmaizericee eemeressorairend [Change 320 | te Beaing cone | Change Bean Chang xe Ssnooting capagior&’ | operas Re-wsate aera inert (colegtan) | an © acral Regarding the items or parts marked © in the table of periodical maintenance customers or users should perform periodical maintenance of the items or parts marked O by themselves For such items or parts marked @, contact our office nearby or distributor because technical knowledge is. required ‘Also the maintenance interval in the table shall be based on the normal operation conditions, Regarding the periodical maintenance between inspection period and operation hours, maintenance or inspection should be performed, roughly according to 250 hours/month, 3,000 hours/year, 6,000 hours/2 years, 12,000 hours/4 years, 18,000 hours/6 years and 24,000hours/8 years. 331 shows the interval time of bearing replacement for the compressor of the pressure of 0.70MPa, 52 shows the interval time of bearing replacement for the compressor of the pressure of 0.85MPa +3 shows the interval time of bearing replacement for the compressor of the pressure of 0.93MPa, +4 Please make sure to use the AIRMAN genuine dedicated oil “LONG-LIFE HP”. However, in case AIRMAN dedicated ol is un-acquirable, using the recommendation oil ofa statement in 5.4.8, ‘and please reduce by hat all the periods those are suggested inthe table of periodic inspection maintenance. © Only main components are mentioned in the table. © Maintenance interval means that periodical maintenance should be repeatedly carried out. © Use AIRMAN genuine parts and recommended oil for replacement. » When such parts which are not mentioned in the table need inspection and or maintenance, contact our office nearby or distributor. 535. Periodic Inspection List 5.3.2. Periodical Inspection and maintenance (B) In case that total operation hours per one year are less than 6,000 hours [A trefers tothe inspection items of ayer Taner nara! ingecten tems | nspecton ons [Bey] fey | Gey [Bey [Bey] — Renats [Pape PY | mont | yor | years | yeas | yeas | 6 ye | Sete ———| Indication ofeach gauge ° Goraametod? ‘Oi level to be between] comgresoral tie! [check ° Raimeretaesss™™ | 32 Regan presse meee nore, ete A | neck ° ice any iaeO0i ile Sopra eer ane 5 drain, Crain vey woe | 32 Dustproof air filter | Check ! dean ° 56 | Check = permance 2 bal iter erent een ° 7 Sie at ring ene potion of dyer dran | * | 8" o. band cepating en 52 Duspoofar fier [change ° 6 Air-fiter element Change ° 57 [Compressor of Change 40 St Seavering oc rae [Clan e $6 sarmonacivoiy [Omck ; aA 6, We is ay stoen‘an check! ean e Sared cesnttas | 7 oonas poste Olt Chek] change ° a Bet Paley chek e Fatroral epecet | 58 Olsepartordenent | change e 512 Rubber hose Check e ‘Nylon tube Check e coetmanna ° Tea a] cotter ar fai ; tee Fan imerter Check ! clean e | Wren pany iced Atercover | can . sed, dean tas toons poste conderserotsyer | A [Clean e Removal of debris and yertanmoie [A [Chek e sing ofl fer Change . ei Nyon tbe change e Org Consumatepaot | Check charge . resureomtctvehe | Beon . Resaabe ser eck Chek charge true a45. Periodic Inspection List Tairaree ional Inspesion tems inspeton pots TTT Frey | vey ] vey] Hey] Frey] — Remars | Page "Y | ron | tyes | years | yeas | 6 yeas | year Consume pat ot T none Change I : Consume par ot Sait compeneis vacumrciefvave | Ctenge { ° of noner When is neaviy Oileve! gauge Change | e stained, change tas | semas posse place the puby, bet owe | | . Seringents” | 58 Bearing of mainmotor | Change I l e 1 oe ee | ° Feat are Oi seal orcompresser T si-end emer | : Rubber ose Orange | I . Daatge a .7 T 1 Sepraordsctae at Loe | . Reusable ater check temp. Ambient tom. | | foal sensor Re-uate ar Solenid vate change e Fe use eer ck Compressor er Re-usbs ar check | frecangdyer__| 4 [henge 2 roma Fan contl pressure Re-usabie ater ie | swichiocdyer | * |Chenae 2 ifnemal Cotaroroisealtr [Cheek e feng eer Jesmressora-end [change wee [ze | xe Beating ofcompressor | change 2x30 [xe | x10 Snoating capasar or Rosato ar ceak inverter (cooing fr) —_| rene © iromal Regarding the items or parts marked © in the table of periodical maintenance customers or users should perform periodical maintenance of the items or parts marked O by themselves, For such items or parts marked @, contact our office nearby or distributor because technical knowledge is required. Also the maintenance interval in the table shall be based on the normal operation conditions. Regarding the periodical maintenance between inspection period and operation hours, maintenance or inspection should be performed, roughly according to 600 hours/month, 6,000 hours/year, 12,000 hours/2 years, 24,000 hours/4 years, 36,000 hours/6 years and 48, 000hours/8 years. 241 shows the interval ime of bearing replacement for the compressor of the pressure of 0,70MPa. 32 shows the interval ime of bearing replacement for the compressor ofthe pressure of 0.85MPa. 23 shows the interval ime of bearing replacement forthe compressor of the pressure of 0.93MPa. 3&4 Please make sure to use the AIRMAN genuine dedicated oil ‘LONG-LIFE HP”. However, in case AIRMAN dedicated ols un-acquirable, using the recommendation ol of a statement in 5.4.8, and please reduce by half all the periods those are suggested in the table of periodic inspection! maintenance, © Only main components are mentioned in the table. ‘© Maintenance interval means that periodical maintenance should be repeatedly carried out. © Use AIRMAN genuine parts and recommended ol for replacement + When such parts which are not mentioned in the table need inspection and or maintenance, contact our office nearby or distributor.5. Periodic Inspection List 5.4 Items and Places of Inspection 5.4.1. Check-clean and change of dustproof air filter Left cide Right side © Check the dustproof air filter “I” and “2” for dust or ditt. Ifdust is found to be heavy, remove any dust or dirt. © Ifthe dust and dirt could not be cleaned away from the filter wash the filter using a detergent. Such washings should be limited up to max 5 times. ‘Then replace the filter with a new one after it has been washed 5 times. © Change the dustproof air filter ifit is heavily damaged, (For Replacement parts, See 5.5) ty 120855, 5.4.2 Clean strainer in scavenging orifice When compressor oil is found mixed in discharge air, clean strainer.Remove a nylon tube “3” off the oil scavenging line bottom of the oil separator. @ Remove the bushing “4”. @® Remove strainer “5” from bushing and wash it in diesel oil and clean dust or dirt from it by air blow. When the cleaning is finished, assemble the strainer in the reverse order. When cleaning the strainer, make sure to check O-ring “6” fitted on bushing and replace it with a new one if it is found hardened or damaged. A20727-4 5.4.3 Performance check of safety valve © Close the service valves completely and pull the test ring “7" to check the performance. It is performing normally when the compressed air jets out with turning by slight force. @ When compressed air bursts out, leave your hand from test ring Set pressure O70MPa | 0.85MPa | 093MPa Soler Pat | [STD.spec] [Factory opt]]| Factory opt] ‘Set pressure 150035-4 for safety valve fame ‘© During inspection of safety valve function, never bring your face to safety valve because compressed air may burst out. It is very dangerous because high-pressure compressed air is blown from there. AXWaRNING5. Periodic Inspection List 5.4.4 Check and clean of sirocco fan @ Remove the fan cover “I” and check if there is any crack on sirocco fan “2”. Change the fan, if any are found. © When replacing it, contact our office nearby or distributor because technical knowledge is required. ® Clean dust or dirt from fan blades. © If too much dust is stuck on the fan, the fan will get unbalanced and the abnormal vibration due to such unbalance may cause crack to it. More often clean the fan even before scheduled maintenance interval, when the machine is used in especially dusty environment. 2 © Great care should be taken to handle the sirocco fan "2" because it will be deformed & and damaged if a strong force is applied to | it when rotating it A120720-4 5.4.5 Clean and change air filter element © Loosen the latch “4” of the latch fixing the cup “3” and remove it. © Remove the element “5” and clean dust and dirt. © After cleaning, install element and cup as they were, and surely set the latch fixing the cup. @ Even before periodic inspection interval comes, clean or replace them when they are found dusty or dirty. (For Replacement parts, See 5.5) © Check for oil leak around oil filter “6”. Replace it according to following procedures if reached at the timing of replacement. © Use a wrench or a similar tool to secure the nut “1”, and unlock the nut “2”, © Rotating the nut “I” clockwise causes the belt tension to increase, whereas the tension will be decreased if the nut is rotated counterclockwise. © After the adjustment is completed, tighten the nut “2” to lock it in place. « © Use a wrench or a similar tool to secure the nut “I”, and unlock the nut “2”. ® Use a wrench or a similar tool to loosen the nut “3”, and rotate the nut “3” counterclockwise after it comes into contact with the motor pedestal, using a wrench again. Then, the motor will be moved upward together with the pedestal and the belt tension will decrease. @ Replace the belt with a new one. lf. the fixing bolts of the compressor machine and motor are not loosened, the centering is basically not reauired, @ Tighten the nut “3” first, and secure the belt in position firmly. ‘The belt will be tightened by the weight of the motor and the pedestal. © As the belt can be further tightened by tightening the nut “I” under this condition, tighten and lock the nut “2” in place to prevent the nut “1” from being loosened from the moment when the specified tension is achieved. motor pedestal SAS37SD-5E/6E (Drver built-in type) is shown in this figure asaaz232 ‘© Because there is an initial elongation in the belt when itis replaced with a new one, be sure to make the belt tension adjustment again after performing the loaded operation for about two hours. 585. Periodic Inspection List [How to measure belt tension load using sonic belt tension meter] © Place the tip (sensor) of tension meter about 2em away from the center of belt. In this position, carry out measurement by strumming the center of belt with a finger or hitting on it slightly with a handle of screwdriver. @ Conduct a measurement twice (after performing the loaded operation for about two hours, as there is an initial belt elongation) for [a new belt] and [at the time of readjustment] after the belt is replaced with a new one. @ Note that the belt tension values differ from each other for [a new belt] and [at the time of readjustment]. Check if the belt tension values stay within the range of [at the time of readjustment] after the load operation for two hours. If not, adjust the belt tension values, @ Itis good if the measured value stays within the range of tolerance (£10%) as shown in the table below. It is better, however, that it be adjusted to be approximate to the center value. Values entered by sonic belt tension meter Belt tension values Working Quantity For ‘Type pressure | Unit (g/m) sea if Span length | Newbelt(N) | readjustment (mr) | Ass) | qyrytry | (anm) (SPAN) | (Allowable timid) w (Allowable limit) 0.70 oat 1744 1,512 [STD.spec.]] (1,570 to 1,918) | (1,361 to 1,663) SAS22SD5E 0.85 420 1,723 1,493 SAS228-5E — |[Pactory opt (1,551 to 1,895) | (1,344 to 1,642) 0.93 ‘6 1718 1,489 rscors tl) » (1,546 to 1,890) | (1,840 to 1,638) 0.70 ‘ho 1,690 1,465 [STD.spec.]| (1,521 to 1,859) | (1,319 to 1,612) SAS22SD-6E 0.85 427 1,674 1,451 SAS22S-6E —_[[Pactory opt] (1,507 to 1,841) | (1,806 to 1,596) 0.93 7 1,447 teactory opt _ (1,803 to 1,592) 0.70 135 2,670 2.314 [STD.spec.] (2,403 to 2,937) | (2,083 to 2,545) 6 sassisp-sB | 0.85 ee 2,659 2,305 SAS37S-5B |fpactory pt] Eeherzpicce | 429 | cat o2020) | (20760806 0.93 426 2,653 2,300, Pactoryont] (2,888 02,918) | (2,070 to 2,530) 0.70 = 2,574 2,281 [STD.spec.] (2,817 t0 2,831) | (2,008 to 2,454) sassisp-6B | 0.85 ae Fe 2,564 2,222 SASB7S-6E _|[Ractory opt engagement) (2,808 to 2,820) | (2,000 to 2,444) 0.93 439 2,558 2,217 [Factory opt (2,802 to 2,814) | (1,996 to 2,489) >How to enter data by sonic tension meter, please refer to sonic tension meter manual. 595. Periodic Inspection List Belt type Type ‘SAS298D-5E/6H + SAS22S-5E/6E ‘SASS7SD-SEIGE - SASSTS-SE/GE 50Hz 60Hz 50Hz 60Hz premure [Barone [S22 watvape [Nat Baas | Sat | wacepe | Seah (Bidenec) | 21600] 1 | rzPK-1800) 1 facses Pramcaeso] 1 [uarmisoo| 1 Jerxirio| 2 | snxioso| 2 eoere| 2PK1650| 1 | 12PK-1550) 45. Periodic Inspection List 5.4.8 Replenishment and change of compressor oil © For prevention of fire caused due to deteriorated oil separator, in principle change of compressor oil is to be performed in accordance with the schedule mentioned in the regular maintenance table. However, it is heavily influenced by operation conditions and environmental conditions. If it has been found more dirty and corrupted, it should be changed. © Even continuous oil replenishment cannot improve its deteriorated condition. Be sure to change the oil completely at every scheduled interval. © If machine is continuously operated in such bad conditions, it could damage bearings and degraded oil sticks oil separator to cause accumulated oxidation heat of reaction to lead oil separator fire. For this reason, regular maintenance work should be done surely and perfectly. © When compressor oil is replaced by new one, wait for enough time (2 to 3 minutes) after stopping the operation of the machine. © When the pressure in the separator receiver tank has been found completely relieved in the course of, enough time after compressor stopped, remove oil filler cap “1” and open the drain valve “2” to drain compressor oil. (The pressure in the separator receiver tank can be checked through the pressure gauge “4” located on the top of tank.) Also, open the drain valve “5” of the oil cooler to drain the cooler of the oil accumulated therein. As the drain will flow into the separator receiver tank, use the same method to open the drain valve to remove it. @ After draining compressor oil, surely retighten drain valve “2” and "3". © After filling fresh oil up to the upper level of level gauge, close the oil filler cap. Check the o-ring “3” of oil filler cap for damage or hardening. If there ia any damage, replace it with a new one. (For Replacement parts, See 6.5) @ After starting operation, check and confirm that oil level is within red lines of oil revel gauge. . SAS22SD SEE | SASBTSD-5EIGE ae el SAS228-5E/6E_| SAS37S‘5E/6E ‘er built-in type) ia ‘Quantity of oll between shown in this figure eis mL 281 Quantity of change oil 1301 2001, @ Please make sure to use the AIRMAN genuine dedicated oil "LONG-LIFE HP”. However, in case AIRMAN dedicated oil is un-acquirable, using of the below mentioned oil is strongly recommended, and please reduce by half all the periods those are suggested in the table of periodic inspection maintenanc Maker and Brand of Recommended Oil Maker Brand SHELL SHELL CORENA S3R (VG32) TK NIPPON OIL & ENERGY CORPORATION ancen ieee (© ‘Mixture of different brands compressor oil could cause an inorease of viscosity and make compressor oil sticky. In the worst case, it could cause sticking trouble of compressor air-end "Compressor air-end will not turn’. Also repairing of such air-end needs expensive cost. Therefore, be sure to avoid mixing different brands oil. In case ‘compressor oil brand in use has to be unavoidably changed, itis absolutely necessary to completely clean up the interior of compressor air-end. In such a case, contact "AIRMAN" dealer or us directty Follow the designated regulations to dispose of compressor oil5. Periodic Inspection List 5.4.9 Change oil separator element © Even before the periodic interval time of replacement, replace the oil separator element with a new one whenever the oil consumption increases and also oil is found to have been mixed in the discharge air. @ Remove separator cover bolts 4 pieces. @ Replace element and O-ring by a new one. @ After installing element, be sure to check for oil leak during the operation. © When consumption of the oil is still unusual even after cleaning strainer in the scavenging orifice (See5.4.2), On change the oil separator element with a new one. ee (For Replacement parts, See 5.5) AN2071-4E g portion of dryer drain @ When cleaning of ¥ type strainer “1” at draining portion of dryer drain, close drain valve “2”. @® Remove nut “3” of Y type strainer, and pull out sereen “4”, @ Clean the screen and inside of Y type strainer. © ‘Then, when installing the nut, check O-ring “5” and replace it immediately if it is found damaged. (For Replacement parts, See 5.5) 3 Drain valve °2" should be always kept “OPEN* when it is to be cleaned, 5125. Periodic Inspection List 5.5 Periodic Replacement of Parts — Part Number _ oe SAS20SD-5B/6H | SAS22S-54/6E | SAS37SD-SE/GE] SASG7S‘5E/6B = Dustproof air filter “I” 32163 19501 8216319501 1 Dustproof airfilter “2” | $2163 19701 132163 20600) 32163 196012163 20700| 1 Air filter clement 32143 17200 82143 17100 1 Oil filter 37438 08900 37438 09400 i O-ring Corel filer cap) 03402 25030 03402 25030 1 Oil separator element 34224 03000 34224 02602 1 Oring 2 16 ea 03402 15145 03402 15145 1 Oring (for strainer at draining 21221 05400 21221 05400 i ortion of dryer drain) 3 Above mentioned parts are to be changed or replaced by customer only. When parts other than the ones in the following table are required, contact our office nearby or distributor. 5-135. Periodic Inspection List 5.6 Adjustment of Various data ‘The following set values can be altered and adjusted. However, as far as unloading operation starting pressure (purge starting pressure) PH is concerned, never adjust operation at higher pressure than specified inital setting value, 3Kln case of operation at higher pressure than each specified set value would lead to motor overloading ‘and motor burning and parts. Tritt cet value classified by . —] vrkig pressure Range of set values . O.70MPa | 0.85MPa | 0.93MPa paren Pressure | *"*" {STD spec: [Pctary opt [[actry opt] (MPa) 7. | Fullied recovery pressure ey | cuael atos ete = ~ (purge cancellation pressure) PL. (0.60MPa) | (0.70MPa) | (0.78MPe) ge Unloading operation starting ae cae | aaa 2 press. (purge cancellation H mare | een i a = = lena (Oona) | (ssMtPa)| (093M) Low pressure operation a . 3 Tcaused due to fall press. BE (aosMPa) 2io20 0.02 00.2] 35 ‘foimtvoneme | | wotlain | Seems | — [oe 5 = u Tnvalid Invalid = [= "Timor set for Iimiting stop 5 ae a § operation . (5 minutes) Mhadeceaiel 7 = > Invalid Invalid = 8 |Star operation time y a 0 to 15 seconds - |[- 0: Abnormal stop with dryer available 9. [Dryer function mood 4 0 L:Abnormal warning | = — | — with dryer available 2: Dryer unavailable *— 10 JACGS operating function | © i Olnvalid 1:Enabled | — | — i = F Tavalid Tavalid = 1g [Timer set for judging ong | 6 0 to 300 seconds alae time unloading operation (60 seoond) (Every 6 seconds) 13 | Model setting A orl O:22kw _ LOTR = 14 [Maintenance warning tie | 0 (300 tous) tempore) | — | [How to change primary set value and to switch indication] @When changing each set value, it is possible to change set value within setting range by pressing right and left arrow marks on operation panel, @® After set value is changed, setting is completed by pressing indication changing switch When indication selection switch is pressed longer (than 2 second), first L.(Full load recovery pressure (purge cancellation 2 a pressure) PL) is displayed. Each time indication selection switch farslenS) S$ fabeS/ow Is pressed, each indication wil be selected aia tl Then each time its pressed one time, H.(Unloading operation ease starting pressure (purge cancellation pressure) PH) is switched ‘The display change over from to E.(Low pressure operation caused due to fall of pressure), display mode to setting mode when | 0 T.(Estimated stop time), to U.(- ), to -(Timer set for limiting indication selection switch is stop operation), to b= ), to y.(Star operation time), pressed longer (than 2 seconds), to d.(Dryer function mood), to c (ACCS operating function), to F.( - jo J.(Timer set for judging long time unloading operation), to A (Model setting), to 0,(Maintenance warning time), and to P.(Air service pressure), according to the set orders. A1706436-2 ald6. Long-term Storage and Disposal of Product 6.1 Preparation for Long-term Stoppage If the machine will not be used for a long period, follow the advice below: © Turn the main power supply “OFF” © Keep the stop valves at discharge port closed. Carry out a running:in operation for approx. 20 minutes at an interval of about a week © Perform operation in accordance with the article 3.2 “Operating method” © Ifyou find something wrong with the equipment, take appropriate measures according to 4.2 “Troubleshooting”. 6.2 Disposal of Product © When disposing of this product, be sure to remove the compressor oil from it When you have anything unclear or you want to advise us, contact our office nearby or distributor. 617. Specification 7.1 Specifications 7.4.4 Dryer built-in type [OPT:: Factory option] Model I Unit_| SAS22SD-5E | SAS22SD-6E | SAS37SD-5E | SAS37SD-6E ‘Type Rotary-twin screw, single stage, oil cooled Pree air delivery mimin | 41136] 34 | 41] 36 [34] 69 [62 [59] 69 [62] 59 & | Working pressure pa | 0708s [3 [070 [085 [naa] ao [as oas/ 07a [035 [09s § sro) [fer (orn |tsro} orn | oer) @ | Capacity control system. 2-Point control, A.C.C.S. control, Purge control, Auto start/stop & [Lubrication system Forced oil injection by compressed air pressure & [Driving eystem Bel drive Lubricating oil LONG-LIFE HP “Lubrication oil capacity L 18 I 20 ‘Type ‘Totally-enclosed fan cooled three-phase squirrel cage induction & [Power nominal output kW. 22 (SF LD I 37 SF 1.1) 5 Number of poles P 4 Starting system Star-delta starting Air outlet port 254 (RIB) I 40A (Ri 2B) Dew-point of discharged air c Under the ambient pressure less than 10, 4 | Power consumption EW. 119 LATO li 13. z Refrigerator nominal output | _kW aa 15 aan ana Raia igerant enclosed: 4002) | (Refrigerant enclosed: 1,060) 2 | wien mm 1,380 1.620 Ea Length mm 780 890 >| Height mm 1,420 1,530 Approx. weight for maintenance | kg bid Ss isd 508 380/400V type 710 380/400V type 1,030 © Free air delivery is the value calculated, being converted into suction conditions of compressor air-end (at the primary stage of air filter). © The dew point of discharge air is the value measured at the ambient temperature of 30°C, discharge pressure of 0.70MPa. © When the dryer discharges sediment, the air quantity will decrease due to the deposit of sediment. © Ask our office nearby or distributor for the guaranteed value of free air delivery. Tr7. Specification 7.4.2. Without dryer type (OPT: Factory option] Model [unit | Sasazs-sn | saszasen [ sase7s-se | SASS7S-0E ‘Type Rotary-twin screw, single stage, oil cooled Free air delivery miimin | 41136] 34 [41] 36] 34] 69 [62] 59] 69 [62 [59 [a MPa | 07 [085] 098 [0.70 [oss [09a] 0.70 [085] 0.98 | 0.70 [os [0.98 3 {s10) oer [ors sto) oer oer ist) [ier en iso) for (er) & [Capacity control system 2Point contol, A.C.C:S, control, Purge control, Auto startistop 2 ee Forced ail injection by eompressed air pressure S [Driving system Belt drive Lubricating oil LONG-LIFE HP Lubrication oll capacity L 13 20 ‘Type ‘Totaly-enclosed fan cooled three-phase squirrel cage induction & | Power nominal output kW 22 (SF 1D 37 GF 110) | Number of poles P 4 Starting system Stardelta starting Air outlet port 25A (1B) 32h RI 1B) 2 | wiaen mm 1,380 1,620) 2 =| Length mm 730 390 2 eek mm 1,420 1,530) Ayprox. weight for maintonance | kg | “00 te 645, 200 ee 920 SBOIAOOV type ‘80/400 type © Free air delivery is the value calculated, being converted into suction conditions of compressor airrend (at the primary stage of air filter). © Ask our office nearby or distributor for the guaranteed value of free air delivery. 7.1.3, Motor specifications (Totally-enclosed fan cooled type) ‘Power output Law 22, 37 Frequency. [ie 50. 60 50 60 Voltage Vv. 200 2007220 | 200 | 200/220 aoov |Rating current A | sa | 978816 | 164 146/140 ‘Thermal relay standard set value |_A 53 51/48 95 85/81 ‘Number of poles z 4 Insulation z F a Frequency He, 50 50 60 Voltage V_| 380 | 400 [| 400/440_| 380 | 400 | 400/440 4oov | Rating current A [481 [45.7 [ 43.9408 [s8.0| 2 | 73/70 (80V) [Thermal relay standard set value | A | 28 | 27 | 2524 [o1o[a76| 42/405 Number of poles P 4 Tnsulation F7. Specification SAS22SD-5SE/6E 7.2 Size and Dimensions 7.2.1 Dryer built-in type a61vOPLW NOULOERNOSWORIOTTS & ‘nouvenno:) oor Boers RISO hear: of TET oe Tae BS Se] perme = E rt { g lg k Ly F fl 3 i LB ee u EP LP ‘np l i “Truno wad IANS | us (uaa a Tani aanooo | 7 u ee p=? TRE SONS araveravanwese reer ie SSA Eanooy (ania 10.) wossamanoo vo.) sung BRIO av oNOGT | ry Ea, aes eee t i 7 ie 5 | eee7. Specification SAS37SD-5E/6E i x a 36 = om as © EI * 92 7 = i y 4 = ae 8 4 fap 3 ly) 7 8 yi i i ra af 4 fl Le . 7 To Zea ge q a i v4bazuo0sty gE iy f\tnouwannos) oo SHIOHST (uosszuamoo yoo a Kd = “STERN lea aor TE AIRS IOINGS 8 — i t < 2 8 B °° & {Ii i & = i) o & S ae 3 by ott a 2 A “RS 30 WSLS Se f — a TRE ge iB ho grpancouon ~— N @ a an 3 = Sw 3 8 2% Zod 3g 3 ¢ & 7.2.2 75}-aezo0s1y (yossa n [oo oer za 76 SERRE we rest tease oe TRATIONS teeter r 8 | < 5 ve ¥ || 2 Y 0 1 S Ss ga oO 8 = nmowenas| ||) i 8 hal 1 1 if 2. “pa (= ca ~ ‘(yossauano wos)“ 2 & a IRR ie ‘yossauanoo vos) BRR got w ie a 2 4 pol & als] fad 1 5 =}, 3 el fs7. Specification 7.3 Wiring Diagram SAS22SD-5E/6E (200/220V type) Ee ps fae an Ly # 7 T a —— al» foe eco — levees = aro — fea mes 4s whe —f Sm : a ee 1s si — ames t i ‘A150498E-17. Specification SAS22SD-5E/6E (380/400/440V type) [eed]: fn |e CIEE = bala — fos aa aetna —feremar he i ae Joan siJao| He co Pe {32 yy Bes, Mount + 9) £o4 6 eae jou123 tome 1 Tiapatispentesty ead amie! —m-, eas i 24 — customer os S__ Saeco om ‘A1505006-1 187. Specification SAS37SD-5EI6E (200/220V type) B THe tte ae Hy ey 4 sieges = co ere ese i ing | corrtabnoma Ly —— (Nats Dechert Sept sangeet BEL mmm Opera pver ey spruces Seema Segeragrscor Heracsaacton ‘eremmcy cs Slade ech cra Eecpeacaracoe feraye fees) Sterne ca ge This partie prepared by Obxranssrne | teases A180502E-27. Specification SAS37SD-5E/6E (380/400/440V type) Meyseyee/eehe Powe nan rc) rr — = . Tamayo aoe ea fe i eld! eee! - fee cetmapstonet oneal 7 : : (or atebromal jos a a —] Saree cnt em ie a hr for A.cannecion olen jor fresh e ju rpg —fec mn aniao 1 pen bee nto len tM ee i Cpe alow 2m — gis eaeety — calpmeile (en Lom mi ‘isp repre y ons A160505E-27. Specification 74 ig Diagram 7.4.1 Compressor SAS22SD-5E/6E > oi ping > fie sipng tank ron 1900236 “Aftercooler PC] Pressure control valve ‘Air filter PRSLPRS2 | Pressure sensor Dryer $1,$2,58,84 | Orifice Check valve SV__| Safety valve Oil level gauge SV1__| 2-way solenoid valve or capacity contro Oil cooler SVG__| 2-way solenoid valve (for drain condensate) Oil filter TLE1 _ | Discharge air temperature sensor Strainer TLE2 | Separator discharge air temperature sensor Oil separator Stop valve Pressure gauge Tu7. Specification SAS37SD-5E/6E rot piping —> Air pling thsvidhsy i) «fon Th 1] oo TLE | separator recrer nk, oo 4a <] Separator receiver tank dain 81904246 ‘AC [ARervooler PC] Pressure control valve AF | Airfilter ‘PRSIPRS2 | Pressure sensor cu___| Dryer $1,83,S4 [Orifice CVI,CV2,6V3 | Check valve SV__ | Safety valve G Oil level gauge SVi__ | 2-way solenoid valve Gor capacity contro) oC. Oil cooler 'SV6__| 2-way solenoid valve or drain condensate) OF Oil filter TLEL | Discharge air temperature sensor 081,082 _| Strainer TLEZ | Separator discharge air temperature sensor (083 [ Oil separator VLV2,V3_[ Stop valve P Pressure gauge7. Specification 7.4.2. Dryer SAS22SD-5E/6E i fa ‘AGC [Accumulator oe CCV_[By-pass valve for hot gas ) CON [Condenser oe | ‘CM_[Compressor lo g i HT one CPT_|Capitlary tube | seca ih | ca [Check joint it TI, i= CV_| Charge valve = md CoN EP [Refrigerant pressure gauge FCP_|Fan‘control switch fee FM_|Fan motor HEX | Cooler HP_|[High pressure switch ‘SAS37SD-5E/GE on ; = CON [Condenser oc Tk CCV [Capacity control valve ‘CJ(L) [Check joint on low-pressure side C ON > CVG) | Check joint on high-pressure side C EXV [Capillary tube EPG |Evaporating pressure gauge BG HX [Cooler Cx ® M1_|Motor (refrigerating compressor) ox —« my M2__|Motor (fan motor) or) PRSI | High pressure switch mG PRS2 |Fan-control pressure awitch WK a ST [Strainer ‘SV_[Solenoid valve ‘TTH [Bi-metal thermostat Spy id 120730, 718MEMOOPERATION LOG Vererarion OPERATONTIE | TOTAL OISCHARGE] PUT | PUT [INHALATION OISCHARSE] coun REMARKS SALON -Sramt | srorJOnerarion| aim press | votrace| cunrenr| Aik Tew. [am Tene. | COMPO) a mae star | STOP [ours | wea) | | wf Ce) co) canes wipron BroHOKUETSU INDUSTRIES CO., LTD. 8TH FLOOR SHINJUKU SAN-EI BLDG, 22-2 NISHI-SHINJUKU 1~CHOME, SHINJUKU-KU TOKYO 160-0023 JAPAN TEL:81-3-3348-7281 FAX:81-3-3348-7289 URL:http//www. airman. co. jp Copyright (C) 2016 HOKUETSU INDUSTRIES CO., LTD. All Rights Reserved. 39600 12940 Printed NOV 2019AIRMAN HOKUETSU INDUSTRIES CO,, LTD.