Model SUN600G&SUN1300G
Photovoltaic Grid-connected Microinverter
Rev 1.3
Installation/User Manual 1
Important Safety Instructions
Specifications subject to change without notice - please ensure you are using
the most recent update found at the manufacturer website.
Installation/User Manual 2
Important Safety Instructions
A) Relocate the receiving antenna and keep it well away from the
equipment.
Communication Statement
The Energy Monitoring systems and Analysis (EMA) software analyzes
and reports the performance of each module from real-time data collected
through the Energy Collect Device (ECD) gateway. The EMA
promptly detects any performance issues in the array, pinpointing the
location and nature of the problem and providing precise guidance for
maintenance, all within a user-friendly graphic interface.
Communication between inverters and the ECD may be affected by signal “noise”
from nearby electrical equipment, the distance between inverters and the ECD,
the number of inverters supported, and other factors, so sometimes the ECD
experiences loss of signal or data randomly, that is not a problem or a fault.
If the ECD does not communicate with the EMA database at all, contact support.
Installation/User Manual 3
Important Safety Instructions
CE mark is attached to the solar inverter to verify that the unit follows the
provisions of the European Low Voltage and EMC Directives.
Installation/User Manual 4
Microinverter System Introduction
Installation/User Manual 5
Microinverter System Introduction
This integrated system improves safety; maximizes solar energy harvest;
increases system reliability, and simplifies solar system design, installation,
maintenance, and management.
Simple to install
You can install individual PV modules in any combination of
Module quantity, orientation, different type and power rate
The Ground wire (PE) of the AC cable is connected to the chassis
inside of the Microinverter,potentially eliminating the installationof grounding wire (check
local regulation).
Installation/User Manual 6
Microinverter Introduction
The Microinverters connect with the single-phase grid, and can also
use multiple Microinverters in the form of single-phase grid to achieve
three-phase grid, and operate with most 60and 72 cell PV modules. For
more information, please see the Technical Data page (p.18) of this
manual.
Model Max. #
AC grid PV Module Module Connector
Number Per branch
8 for 25A
SUN600G 50/60Hz,127/240V 60,72 Cell MC-4 Type or Customize
breaker
4 for 25A
SUN1300G 50/60Hz,240V 60,72 Cell MC-4 Type or Customize
breaker
Installation/User Manual 7
Microinverter System Installation
WARNING: Do not touch any live parts in the system, including the
PV array, when the system has been connected to the electrical grid.
Installation/User Manual 8
Installation Procedures
Installation/User Manual 9
Installation Procedures
Installation/User Manual 10
Installation Procedures
Installation/User Manual 11
Microinverter system operating instructions
3. The units should start blinking red one minutes after turning on the AC circuit
breaker.Then blue led blinking. This means they are producing power normally, the faster
blinking of the blue led means more power generated.
4. Plug in the ECD and follow the instructions according to the manual
for the ECD.
Installation/User Manual 12
Troubleshooting
Operation LED
Flashing Slow Blue - Producing small power
Flashing Fast Blue - Producing big power
Flashing Red - Not producing power
Red blinking two times-AC low-voltage or high-voltage
Red blinking three times-Grid Malfunction
GFDI Error
A four time red LED indicates the Microinverter has detected a Ground
Fault Detector Interrupter (GFDI) error in the PV system. Unless the
GFDI error has been cleared, the LED will remain four times blinking.
Other Faults
All other faults are reported to the ECD. Refer to the ECD Installation and
Operation Manual for a list of additional faultsand troubleshooting
procedures.
Installation/User Manual 13
Troubleshooting
Maintenance
No need to Maintenance.
Installation/User Manual 14
Replace a microinverter
D. Close the branch circuit breaker, and verify operation of the replacement
Microinverter.
Installation/User Manual 15
Technical Data
Installation/User Manual 16
SUN600G Microinverter Datasheet
Installation/User Manual 17
SUN1300G Microinverter Datasheet
Model SUN1300G-240V
Input Data (DC)
MPPT Voltage Range 25V-55V
Operation Voltage Range 20V-55V
Maximum Input Voltage 60V
Startup Voltage 20V
Maximum Input Current 1 0.4A x 4
Maximum DC Short Circuit Current 13A
Output Data (AC)
Maximum Output Power 1300W
Nominal Output Voltage 240V
Nominal Output Current .5.416A
Installation/User Manual 18
Sample Wiring Diagram SUN600G
MAX 9 SUN600G
RED L1
26
Sunshine Sunshine Sunshine
BOXGROUNDmeter
RTU
ECD ETHERNET CABLE
Installation/User Manual
YELLOW NEUTRALETHERNET CABLE
TO BROADBAND ROUTER
MA 8 SUN600GMAX 8 SUN600GBLACK L2
19
GROUND
TO BROADBAND ROUTERECDMAX 8 SUN600G2726S
Sample Wiring Diagram SUN600G
MA 8 SUN600G
RTU
ECD
ETHERNET CABLE
Installation/User Manual
TO BROADBAND ROUTER
20
GROUND
Sample Wiring Diagram SUN1300G
JUNCTION BLACK L2
RED L1
BOX YELLOW NEUTRAL
MAX 4 SUN1300G
MAX 4 SUN1300G
Sample Wiring Diagram Three Phase
meter
MAX 4 SUN1300G
Installation/User Manual
RTU
21
ECD ETHERNET CABLE
GROUND TO BROADBAND ROUTER
Sample Wiring Diagram SUN1300G
JUNCTION BLACK L2
RED L1
BOX YELLOW NEUTRAL
MAX 4 SUN1300G
MAX 4 SUN1300G
meter
Sample Wiring Diagram Single Phase
MAX 4 SUN1300G
Installation/User Manual
22
RTU
ECD ETHERNET CABLE
GROUND TO BROADBAND ROUTER