Professional Documents
Culture Documents
• Three changes to optimise HFSI part life and costs and m/c performance.
o IBT Drive Gear reduced to 275k to reduce banding (default 550k belt revolutions ≈ 6M A4)
o Cooling Belt Upper & Lower Steering Roll increase to 8M (previously 2M, default 4M)
Note: HFSIs that have changed from the m/c default threshold show the Default value in black in the last column.
Changes to the Previous ACA threshold are shown red in the last column.
• A UK NVM Script (v2) has been created to optimise numerous NVMs on the m/c’s
o Sets sleep timer to 15 mins
o Sets the Auto Resume Print Timer to 5 seconds
o Sets the Auto Resume Timer to 2 mins
o Sets the StockByNameOnly OFF for new stocks
o Disables the Deburr Assembly
o Set Script version (in service phone no area)
Note: country phone numbers are in separate scripts now if required
o Enables Page/Serial No./Time/Date stamp on various test prints
o Sets Booklet Wrinkle fix
o Sets HCF & PR-Fin stack limits
o Enables IDM manual curl for heavyweight and speciality medias
• The RML has been optimised for XE and ease of use (based on the latest RML available)
o All non XE stocks removed
o All stocks have the Stock By Name Only option unselected by default
o All stocks have the tray empty slider set to minimum (Chamonix was on the tray)
o There is a dummy stock with this information which can be used to check it is loaded -
use the Search feature and search for rml
Save the folder UKFINDS Iridesse ACA_HFSI_Script_RML 01-10-20 to the Documents folder on the
PCUI
Ensure the right arrow (write to IOT) is selected then click the PC icon to select the script
When the ‘Restore’ has finished, you may see Write Errors depending on the output configuration
Note: load country phone number scripts after main NVM script.
To install the new Recommended Media List .rml file, use the profiles Shortcut on the Desktop then
select the rml folder or paste this path into any explorer window…
C:\ProgramData\xerox\ProductionPrinter\UI\public\custom\rml
Note: the ProgramData folder is a hidden folder so you cannot just browse to it
Create a new folder called rml old and move all existing .rml files into this folder
Copy the new Xerox Iridesse Production Press XE_SNOoff_LOW v3 200520 file into the main rml
folder
Open the Stock Library in the PCUI application, the RML will take a few seconds to reload
Check that the new RML has been loaded by typing rml in the search bar and you should see the