1 Pumpe ty pe Single-/Multi-pump set Fluid Water
2 No. of pumps 2 Operating temperature t A °C 4
3 Nominal f low m³/h 30 pH-v alue at t A 7
4 Nominal head m 46 Density at t A kg/m³ 1000
5 Static head m 0 Kin. v iscosity at t A mm²/s 1.569
6 Inlet pressure kPa 0 Vapor pressure at t A kPa 100
7 Env ironmental temperature °C 20 Solids 0
8 Av ailable sy stem NPSH m 0 Altitude m 0
Pump data
9 Pump designation Max. mm 105
10 GSD20/15SV04F040T Impeller Ø designed mm 105
11 Design Fixed speed sets Min. mm 105
12 Make Nominal m³/h 30.5 ( 15.3 )
13 Flow Max- m³/h 24
14 Speed rpm 2900 Min- m³/h
15 Nominal m 47.7
16 Max. working pressure kPa 572.7 Head at Qmax m 28.7
17 Head H(Q=0) m 58 at Qmin m 58.4
18 Weight kg On demand Shaf t power kW 5.5 ( 2.7 )
19 Weight data include external package Max. shaf t power kW 6
20 Ef f iciency % 72.97
21 NPSH 3% m 1.4
Materials
22 Booster Motor data
23 Manif olds Stainless steel, 1.4301, AISI 304 Manuf acturer Lowara Electric v oltage 380 V
24 On-of f v alv es Stainless steel, 1.4401, AISI 316 Specif ic design IE3 Three phase surf ace motor
25 Non-return v alv es Stainless steel, 1.4301, AISI 304 Ty pe PLM112.../340 E3
26 Pressure switches AISI 301 R ated power 4 kW Electric current 7.7 A
27 Pressure trasmitters Stainless steel, 1.4301, AISI 304 Speed 2885 rpm Degree of protection IP 55
28 Caps/plugs/f langes AISI 304 / 316 Frame size 112 Insulation class F
29 Fittings Stainless steel, 1.4401, AISI 316 Weight 29 kg R AL 5010
30 Bracket Galv anized steel/painted steel

31 Base Painted steel


32
Standard options
33 Non return v alv e position Non return v alv e in deliv ery side
34 Set certif icate
35 Material Combination /A304 G S 10-22 SV AISI A304 materials
36 Pump Test Set without certif ied pumps
37 High pressure protection Without high pressure protection on deliv ery
38 Turned Deliv ery Manif old Standard
39 Ov ersize Piping Standard manif old
40 Control Panel Clean Contacts Standard
41 Protection Against Dry R unning Without protection against dry running
42 Control Dev ices Ov ersized Standard
43 Deliv ery Side Standard deliv ery
44 Suction side Standard suction
45 Pressure Transmitter Standard
46 Control Panel Position Standard position
47 Electric Pump Special Seals Standard
48 Non-return Valv e Standard non-return v alv e

Remarks

Project Created by Rachael Amelia Last update 10/31/2022


Block Block: 4 kW Created on 10/31/2022
Program version Data version User group(s)
65.0 - 27/09/2022 (Build 180) 20/10/2022 13:44 Xylem: Indonesia - EXT
GSD20/15SV04F040T
Company name
Contact
Performance curve Phone number
e-mail address

Operating Data Specification Hydraulic data (duty point) Impeller design


Flow 30 m³/h Flow 30.5 m³/h Impeller R 105 mm
Head 46 m Head 47.7 m Frequency 50 H z
Static head 0m MEI: >=0, 70 - according to Ecodesign Directiv e 2009/125/EC
Speed and R egulation (EU) No.547/2012
2900 rpm

Power datas refered to:


Water [100%] ; 4°C; 1000kg/m³; 1.57mm²/s
Perf ormance according to ISO 9906:2012 – G rade 3B

m] Head
[
1
58
56
54
52
50
48 47.7 m
46 Eff.
44 73.6%
42
40
38
36
34
32
30
15SV04 [Pump 1] 15SV04 [Pump 1+2]
28
26
24
22
20
18
16
14
12
10
8
6
4
2
[ %0] 73 %
70 Efficiency
65 Overall efficiency
60 15SV04 [Pump 1] 15SV04 [Pump 1+2]64.7 %
55 15SV04 [Pump 1] 15SV04 [Pump 1+2]
50
45
40
35
30
25
20
15
10
5
0
[m]
NPSH-values 15SV04 [Pump 1] 15SV04 [Pump 1+2]
3.6
3.2
2.8
2.4
2.0
1.6
1.38 m
1.2
0.8
0.4
0.0
[kW]
Shaft power P2
6.0 15SV04 [Pump 1+2] (P2)
5.5
5.45 kW
5.0
4.5
4.0
3.5
3.0 15SV04 [Pump 1] (P2)
2.5
2.0 30.5 m³/h
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 m³/h]
[

Project Created by Rachael Amelia Last update 10/31/2022


Block Block: 4 kW Created on 10/31/2022
Program version Data version User group(s)
65.0 - 27/09/2022 (Build 180) 20/10/2022 13:44 Xylem: Indonesia - EXT
GSD20/15SV04F040T
VFD Analysis
m] Head
[
1

60
58
56
54
52
50
48 47.7 m
46 Eff.
44 73.6%

42
40
38
36 73.6%
34
32
30
73.6% 15SV04 [Pump 1] 15SV04 [Pump 1+2]
28
26
24
45 Hz 45 Hz
22 73.6%
20
18 40 Hz 40 Hz
16 73.6%
14 35 Hz 35 Hz
12
10 30 Hz 30 Hz
8
6
4
2
30.5 m³/h
0
0 4 8 12 16 20 24 28 32 36 40 44 48 m³/h]
[
Curve ISO

Pumps
running Specific
/System Frequency Flow Head Shaft power Flow Head Shaft power Pump eff. energy NPSHre
1 50 Hz 15.3 m³/h 47.7 m 2.73 kW 30.5 m³/h 47.7 m 5.45 kW 73 % 0.201 kWh/m³ 1.38 m
1 45 Hz 13.7 m³/h 38.6 m 1.99 kW 27.5 m³/h 38.6 m 3.97 kW 73 % 0.163 kWh/m³ 1.17 m
1 40 Hz 12.2 m³/h 30.5 m 1.4 kW 24.4 m³/h 30.5 m 2.79 kW 73 % 0.129 kWh/m³ 0.966 m
1 35 Hz 10.7 m³/h 23.4 m 0.935 kW 21.4 m³/h 23.4 m 1.87 kW 73 % 0.0986 kWh/m³ 0.78 m
1 30 Hz 9.16 m³/h 17.2 m 0.589 kW 18.3 m³/h 17.2 m 1.18 kW 73 % 0.0724 kWh/m³ 0.609 m

Project Project ID Created by Created on L ast update


Rachael Amelia 10/31/2022 10/31/2022

Program version Data version User group(s)


65.0 - 27/09/2022 (Build 180) 20/10/2022 13:44 Xylem: Indonesia - EXT
GSD20/15SV04F040T
Company name
Contact
Dimensions Phone number
e-mail address

PLEASE NOTE:

Dimensions mm
A 350.5 H 200
B 408.5 H1 794.5 Weight (Include external package)
C 848 H2 944 On demandkg
D 610 H3 719
DNA R 3"
DNM R 3"
E 135
F 370
G 640

Project Created by Rachael Amelia Last update 10/31/2022


Block Block: 4 kW Created on 10/31/2022
Program version Data version User group(s)
65.0 - 27/09/2022 (Build 180) 20/10/2022 13:44 Xylem: Indonesia - EXT