CORRIGENDA No.

1 August 2021
Part 1 Seagoing Ships

Volume I

RULES FOR CLASSIFICATION AND SURVEYS

2021

Biro Klasifikasi Indonesia

Copyright © 2021 Biro Klasifikasi Indonesia


Jl. Yos Sudarso No. 38-40, Tanjung Priok
Jakarta 14320 - Indonesia
rules@bki.co.id
www.bki.co.id
Pt. 1 Seagoing Ships
Vol. I Rules for Classification and Surveys
Foreword

Foreword
Corrigenda No.1 gives a correction to the “Rules for Classification and Surveys (Pt.1, Vol.I) 2021
consolidated edition”. This Corrigenda are marked by strikethrough, red color and expanded text which is
to be read in conjunction with the requirements given in the 2021 Consolidated Edition.

This Corrigenda is available to be downloaded at www.bki.co.id. Once downloaded, this Corrigenda will be
uncontrolled copy. Please check the latest version on the website.

Further queries or comments concerning this Rules are welcomed through communication to BKI Head
Office.

B iro Klasifi kasi Indonesia – 2021 Page i i


Pt. 1 Seagoing Ships
Vol. I Rules for Classification and Surveys
Corrigenda No. 1

Corrigenda No. 1 – Aug 2021

Surveys – General Requirements

B. Surveys for Maintenance of Class


1. Periodical Surveys

1.3 Class Renewal Surveys

1.3.2 Scope

1) The Class Renewal Survey is to include, in addition to the requirements of the Annual Survey,
examination, tests and checks of sufficient extent to ensure that the hull, equipment and related
piping, as required in 1.3.2.12), are in satisfactory condition and fit for the intended purpose for the
new period of class of five years to be assigned, subject to proper maintenance and operation and
the periodical surveys being carried out at the due dates.
2) The examinations of the hull are to be supplemented by thickness measurements and testing and
thickness measurements as required in 1.3.2.11).9) and 1.3.2.12).11), to ensure that the
structural integrity remains effective. The aim of the examination is to discover Substantial
Corrosion, significant deformation, fractures, damages or other structural deterioration, that may
be present.

Co rrec tio n : c ha n g e referen c es reg a rd ing th e h u ll ex a mina tio n ( in a c co rd an c e with


IACS UR Z 7 Rev. 2 8 Co rr. 1 )
----------------------------------------------------------------------end---------------------------------------------------------------

B iro Klasifi kasi Indonesia – 2021 Page 1