You are on page 1of 1

Floor Seismic mass h Ah VB Wihi2 Qi (KN) Storey Shear (KN)

1 8285.078 3.3528 93134.78 39.39456 7718.607045


2 5637.637 6.7056 253496.8 107.2252 7679.21248478138
3 7117.656 10.0584 720103.3 304.5925 7571.98731186822
4 6914.077 13.4112 1243568 526.0098 7267.39484440238
5 6800.908 16.764 1911271 808.4377 6741.3850272681
0.135 7718.607
6 6509.778 20.1168 2634414 1114.316 5932.94731627939
7 6225.445 23.4696 3429113 1450.461 4818.63139897466
8 5759.862 26.8224 4143882 1752.797 3368.17013245778
9 2774.38 30.1752 2526191 1068.54 1615.37278447416
10 1150.046 33.528 1292798 546.8332 546.833190963163
57174.867 18247971

Z Seismic Zone Factor = 0.36


I= Importance Factor = 1.2
R= Response Reduction Factor = 4
Tx = Time period in x direction = 0.5445 sec
Ty = Time period in y direction = 0.5445 sec
sa/gx = Design acceleration coef = 2.5

You might also like