Professional Documents
Culture Documents
SELECTION GUIDE
AGILENT INFINITYLAB LC SERIES
EFFICIENT LC SOLUTIONS –
FOR ANY APPLICATION AND BUDGET
The Agilent InfinityLab LC Series offers you an unmatched choice of instrumentation for liquid
chromatography. Use this product selection guide to identify which configuration fits best to your
laboratory’s requirements.
Analytical LC Systems
From routine analysis to cutting-edge research, the Agilent InfinityLab LC Series offers the broadest portfolio of liquid
chromatography solutions, helping you to achieve highest operational efficiency while keeping within your budget.
NEW
2
InfinityLab LC Workflow Solutions
The flexibility of the InfinityLab LC Series allows Agilent to offer the broadest portfolio of liquid chromatography solutions.
From LC method development to GPC/SEC and SFC, and from online SPE to 2D-LC, the InfinityLab LC Series gives you
infinite possibilities to solve your separation challenges.
InfinityLab InfinityLab LC
Online SPE Solutions Method Development Solutions
Enrich analytes, remove matrix Accelerate your method development with
components or lower detection dedicated hardware and software. Utilize up
limits with tailored solutions to match to 26 solvents and 32 columns to create more
virtually any analytical LC challenge. than 1000 different sets of LC conditions.
For details of Agilent InfinityLab LC Purification Solutions, see our Selection Guide, publication number 5991-8010EN. 3
AGILENT INFINITYLAB LC SERIES
Instrument Control
InfinityLab LC Companion Handheld instrument controller for 1260 and 1290 Infinity II LCs G7108AA
Solvent Preparation
1260 Infinity II Degasser 4 channels; up to 10 mL/min flow; 12 mL internal volume per channel G7122A
Solvent Delivery
1290 Infinity II High Speed Pump 1300 bar up to 2 mL/min, ramping down to 800 bar at 5 mL/min; binary solvent mixing; integrated G7120A
degassing unit
1290 Infinity II Flexible Pump 1300 bar up to 2 mL/min, ramping down to 800 bar at 5 mL/min; quaternary solvent mixing; G7104A
integrated degassing unit
1260 Infinity II Flexible Pump 800 bar up to 5 mL/min; quaternary solvent mixing; integrated degassing unit G7104C
1260 Infinity II Binary Pump 600 bar up to 5 mL/min; integrated degassing unit; optional SSV G7112B
1260 Infinity II Quaternary Pump 600 bar up to 5 mL/min; 200 bar up to 10 mL/min; integrated degassing unit G7111B
1260 Infinity II Bio-Inert Pump 600 bar up to 5 mL/min; 200 bar up to 10 mL/min; integrated degassing unit; quaternary mixing; G5654A
all materials in flow path inert
1260 Infinity II Isocratic Pump 600 bar up to 5 mL/min; 200 bar up to 10 mL/min; optional integrated degassing unit and SSV G7110B
1260 Infinity II SFC Binary Pump Delivers supercritical CO2 and modifiers at up to 600 bar and 5 mL/min; binary solvent mixing; G4782A
integrated degassing unit and two-solvent selection valve for channel B
1260 Infinity Capillary Pump1 Up to 20 μL/min; up to 100 µL/min with extended flow range kit; 400 bar; 0.18 to 1.0 mm column id G1376A
1260 Infinity Nanoflow Pump1 Up to 4 μL/min; 400 bar; 0.075 to 0.1 mm column id G2226A
LC Support Modules
1260 Infinity II SFC Control Module Compresses CO2 and houses backpressure regulator; uses liquefied (analytical grade) or gaseous CO2 G4301A
(beverage grade); low dispersion nozzle for full flow transfer to MS or ELSD
4
Valve Solutions
1290 Infinity Flexible Cube For enhanced injection modes and advanced valve-switching applications such as online SPE G4227A
1290 Infinity Valve Drive Drive unit for any InfinityLab Quick Change valve head G1170A
InfinityLab Quick Change Valves Available in stainless-steel for high-pressure and ultrahigh-pressure applications up Get product
to 1300 bar as well as with bio-inert materials in flow paths for bio-chromatographic numbers2
applications
Sample Injection
1290 Infinity II Multisampler 0 to 20 μL or 0 to 100 μL single-stroke injection at 1300 bar; up to 1500 μL with optional G7167B
kits; sample capacity up to 432 vials and up to 16 microtiter plates; multiwash option
for less than 9 ppm carryover; optional sample cooling (Option 100) or thermostatting
(Option 101) available; dual-needle option for highest throughput and flexibility
1290 Infinity II Vialsampler 0.1 to 20 μL (40 optionally); up to 120 µL with multi-draw mode at 1300 bar; G7129B
sample capacity up to 132 x 2 mL vials; optional integrated column compartment for
column heating up to 80 °C; optional sample cooling (Option 100) or thermostatting
(Option 101) available
1260 Infinity II Multisampler 0 to 100 μL single-stroke injection at 800 bar; up to 1800 μL with optional kits; sample G7167A
capacity up to 432 vials and up to 16 microtiter plates; multi-wash option for less than
9 ppm carryover; optional sample cooling (Option 100) or thermostatting (Option 101)
available; dual-needle option for highest throughput and flexibility
1260 Infinity II Vialsampler 0.1 to 100 μL injection from vials at up to 800 bar; up to 1500 µL with optional kits; G7129C
optional integrated column compartment for column heating up to 80 °C; optional
sample cooling (Option 100) or thermostatting (Option 101) available
1260 Infinity II Vialsampler 0.1 to 100 μL injection from vials at up to 600 bar; up to 1800 µL with optional kits; G7129A
optional integrated column compartment for column heating up to 80 °C; optional
sample cooling (Option 100) or thermostatting (Option 101) available
1260 Infinity II Bio-Inert Multisampler 0 to 100 μL single-stroke injection at 600 bar; up to 1000 µL with optional kits; sample G5668A
capacity up to 432 vials and up to 16 plates; multi-wash option for less than 9 ppm
carryover; optional sample cooling (Option 100) or thermostatting (Option 101)
available; all materials in flow path inert
1260 Infinity II SFC Multisampler Operates in SFC or LC mode; in SFC mode, injection is done through Feed Injection G4767A
principle that enables highly reproducible injection with injection volumes from
0.1 to 90 μL at up to 600 bar; in LC mode, injection is done through classic flow-through
principle; sample capacity up to 432 vials and up to 16 microtiter plates; optional
sample cooling (Option 100) or thermostatting (Option 101) available
1260 Infinity High-Performance 0.01 to 8 μL injection from vials and microtiter plates G1377A
Micro Autosampler1
1
Check with Agilent for availability in your country. 2
Visit www.agilent.com/chem/lc-valve-solutions for product numbers. 5
Column Compartments
1290 Infinity II Multicolumn Thermostat 20 degrees below ambient to 110 °C; up to four 30 cm columns and up to eight 10 cm G7116B
columns; up to eight individual InfinityLab Quick Connect heat exchangers for standard-
flow, high-flow and ultralow dispersion; optional valve drive for InfinityLab Quick
Change valve heads
1260 Infinity II Multicolumn Thermostat 10 degrees below ambient to 85 °C; up to four 30 cm columns; up to four individual G7116A
InfinityLab Quick Connect heat exchangers; optional valve drive for InfinityLab Quick
Change valve heads (up to 800 bar and up to 4-column selection without replumbing)
UV Detection
1290 Infinity II Diode Array Detector ± 0.6 μAU/cm noise (60 mm Max-Light cartridge cell) or ± 3 μAU/cm noise G7117B
(10 mm Max-Light cell); 240 Hz; spectra; 8 signals; 1 to 8 nm slit; 190 to 640 nm
1290 Infinity II Diode Array Detector FS ± 0.6 μAU/cm noise (60 mm Max-Light cartridge cell) or ± 3 μAU/cm noise G7117A
(10 mm Max-Light cell); 120 Hz; spectra; 8 signals; fixed slit; 190 to 640 nm
1290 Infinity II Variable Wavelength Detector ± 1.5 μAU noise; time-programmable, 240 Hz (single wavelength detection); G7114B
2.5 Hz (dual wavelength detection); 190 to 600 nm
1260 Infinity II Diode Array Detector HS ± 0.6 μAU/cm noise (60 mm Max-Light cell) or ± 3 μAU/cm noise G7117C
(10 mm Max-Light cell); 120 Hz; spectra; 8 signals; fixed slit; 190 to 640 nm
1260 Infinity II Diode Array Detector WR ± 7 μAU/cm noise; 120 Hz; spectra; 8 signals; 190 to 950 nm G7115A
1260 Infinity II Multiple Wavelength Detector ± 7 μAU/cm noise; 120 Hz; 8 signals; 190 to 950 nm G7165A
1260 Infinity II Variable Wavelength Detector ± 2.5 μAU/cm noise; 120 Hz (single wavelength detection); G7114A
2.5 Hz (dual wavelength detection); 190 to 600 nm
Special Detection
1290 Infinity II Evaporative Light For subambient operation; flow range 0.2 to 5 mL/min; evaporator temperature G7102A
Scattering Detector 10 to 80 °C; nebulizer temperature 25 to 90 °C
1260 Infinity II Evaporative Light For subambient operation; flow range 0.2 to 5 mL/min; evaporator temperature G4260B
Scattering Detector 25 to 120 °C; nebulizer temperature 25 to 90 °C
1260 Infinity II Fluorescence Multisignal fluorescence detector; online spectra; 4 signals; 148 Hz; 4000 h lamp; G7121B
Detector Spectra Raman (H2O) > 500 (noise reference measured at signal); Raman (H2O) > 3000
(noise reference measured at dark value)
1260 Infinity II Fluorescence Detector One signal wavelength, 74 Hz; 4000 h lamp; Raman (H2O) > 500 (noise reference G7121A
measured at signal); Raman (H2O) > 3000 (noise reference measured at dark value)
1290 Infinity II Refractive Index Detector 148 Hz; 1.00 to 1.75 RI range; ±600 x10-6 RIU measurement range; G7162B
Noise < ±2.5 x10-9 RIU; < 1 h warm-up; 5 degrees above ambient up to 55 °C
1260 Infinity II Refractive Index Detector 74 Hz; 1.00 to 1.75 RI range; ±600 x10-6 RIU measurement range; G7162A
Noise < ±2.5 x10-9 RIU; < 1 h warm-up; 5 degrees above ambient up to 55 °C
6
Fraction Collection
1290 Infinity Thermostat 4 to 40 °C (for all fraction collectors) G1330B
1260 Infinity II Bio-Inert Analytical-Scale Up to 10 mL/min flow; all materials in flow path inert G5664B
Fraction Collector
GPC/SEC Systems
1260 Infinity II GPC Multi-Detector System Single or dual-enclosure system; accommodates any combination of refractive index G7800A
detector, viscometer, and light scattering detector
1260 Infinity II GPC/SEC MDS 660 nm light source; 6 μL cell volume; linearity 250 μRIU; short-term noise < 20 nRIU G7801A
Refractive Index Detector (< 80 μV); pressure rating 350 kPa (50 psi); temperature range 30 to 60 °C;
temperature stability ± 0.2 °C; sensitivity 4 mV/μRIU
1260 Infinity II GPC/SEC MDS Viscometer Linearity 0.5 % FS; shear rate (typical) 3000 s-1; sensitivity ηsp 1 x 10-5 Pa.s; temperature G7802A
range 30 to 60 °C, temperature stability ± 0.2 °C
1260 Infinity II GPC/SEC MDS Dual-Angle Sample cell volume 10 μL; light scattering volume 0.01 μL; laser wavelength/ G7803A
Light Scattering Detector power 660 nm/50 mW; Rayleigh scattering angles 15° and 90°; temperature range
30 to 60 °C; temperature stability ± 0.2 °C
1260 Infinity II High-Temperature GPC System Pump flow range 0.1 to 10.0 mL/min; reproducibility ≤ 0.07 %; oven capacity up to G7820B
six 6 x 300 mm GPC columns; temperature range ambient to 220 °C; temperature
stability < 0.05 °C/h; RID flow cell volume 8 µL; sensitivity 2.5 x 10-7 RIU/mV;
noise ≤ 80 µV; wavelength 890 nm; drift ≤ 10 mV/h; autosampler capacity 40 x 2 mL
vials; integrated 6-port/2-position valve; flushed fixed loop 5 to 500 μL
1260 Infinity II High-Temperature Viscometer Linearity 0.5 % FS; shear rate (typical) 3000 s-1; sensitivity ηsp 1 x 10-5 Pa.s G7821B
1260 Infinity II High-Temperature Sample cell volume 10 μL; light scattering volume 0.01 μL; laser wavelength/power G7822B
Light Scattering Detector 680 nm/30 mW; Rayleigh scattering angles 15° and 90°
1260 Infinity II High-Temperature Evaporator temperature range 25 to 120 °C; nebulizer and transfer line 25 to 160 °C; G7826A
Evaporative Light Scattering Detector short-term noise < 0.2 mV; drift < 1 mV/h; LED light source (480 nm); PMT detection
with digital signal processing; flow rate range 0.5 to 5.0 mL/min; gas flow 0.2 to 0.5 SLM
SP260VS Sample Preparation System Temperature range ambient to 260 °C; temperature accuracy ± 2 °C; sample G7823A
capacity 20, minimum 2 mL, maximum 20 mL; filtration 0.5 or 2 µm frit; agitation by
horizontal motion with variable speed control
Integrated LC Systems
1220 Infinity II Gradient LC Binary gradient solvent pump, autosampler, column oven and diode array detector G4294B
1220 Infinity II Gradient LC Binary gradient solvent pump, autosampler, column oven and variable G4290B
wavelength detector
1220 Infinity II Gradient LC Binary gradient solvent pump, manual injector and variable wavelength detector G4288B
1220 Infinity II Isocratic LC Single solvent pump, manual injector and variable wavelength detector G4286B
7
Learn more
www.agilent.com/chem/infinitylab-lc-series
Europe
info_agilent@agilent.com
Asia Pacific
inquiry_lsca@agilent.com