Troubleshooting

9.1 Indoor unit error display

For FSR1-21CRN1-QB8W, FSR1-24CRN1-QB8W models:

Operation Timer Auto lamp Failure


lamp lamp
☆ ☆ ☆ Over current protection occurs 4 times.

☆ X X The T2 sensor is open circuit or short circuit

X ☆ X The T1 sensor is open circuit or short circuit

☆ ☆ X EEPROM error

X X ☆ Indoor / outdoor units communication error

For FSR1-21HRN1-QB8W, FSR1-21HRN1-QB4W, FSR1-24HRN1-QB4W, FSR1-24HRN1-QB8W

models:

Operation Timer Defrosting Auto Failure


lamp lamp lamp lamp
☆ ☆ ☆ X Over current protection occurs 4 times.

☆ X X X The T2 sensor is open circuit or short circuit

X ☆ X X The T1 sensor is open circuit or short circuit

X X ☆ X The T3 sensor is open circuit or short circuit

☆ ☆ X X EEPROM error

X X X ☆ Indoor / outdoor units communication error

O (light) X ( off ) ☆( flash )