EARTHING TRANSFORMERS - ETR

I EARTHING TRANSFORMERS - ETR


ETR earthing transformers are used to create Radiators are hot dip galvanized and painted,
an artificial neutral in distribution electric the tanks are provided with a zinc layer using
networks: spray zinc metallizing method.

The expansion tank is equipped with an oil


level gauge.

Fig.1 earthing transfomer in an electric distribution network

Typical parameters of ETR earthing


transformers are:
- networks of 6, 10, 15, 20, 35 kV
- rated power from 200 to 5000 kVA
- connection group Zn, ZNyn 11 or other
variants based on customer´s wishes

Typical ETR earthing transformers are placed


in a corrugated wall tank and are hermetically
sealed.
Smaller corrugated wall tanks are hot dip
galvanized and painted (if required). Typical
colour shade is RAL 7033. Larger tanks are Fig.3 ETR earthing transfomer – tank with radiators
painted with zinc paint.
Bushings are of various types: porcelain DIN or
EN bushings, Euromold or Connex cable
connectors.

The transfomer oil temperature is monitored by


a thermometer.

Typical transformer oil used in ETR earthing


transformers is Shell Diala S2.

Lugs determined for lifting the complete


transformer are placed on the cover or on tank
walls under the cover (larger earthing
transformers).

ZNyn earthing transformers are equipped with


an off-load tap changer purchased from one of
the most prestigious companies.

ETR earthing transformers are equipped with


Fig.2 ETR earthing transfomer – hermetically sealed an oil drain valve placed at the bottom of a
transformer.
Alternatively larger ETR earthing transformers
can be placed in a tank equipped with DIN If required the transformers can be equipped
radiators, an expansion tank and an air with bi-directional wheels.
breather.

ELA O 162.2 EN EGE, spol. s r.o. Novohradská 34 37008 České Budějovice Czech Republic
Tel.: 00420 38 77 64 412, Fax: 00420 38 77 64 603, e-mail: elaobch@ege.cz, www.ege.cz
EARTHING TRANSFORMERS - ETR

Table.1 – examples of ETR earthing transformers:


- ZN connection group
- continuous operation duty
- corrugated tank
- hermetic design

RATED
L - length W- width H - height
POWER

ТYPE [кVА] [mm] [mm] [mm]


ETR0200 200 1350 770 1200
ETR0315 315 1360 770 1400
rated voltage
10,11 kV

500 1500 950 1550


Network

ETR0500
ETR0800 800 1900 1300 1550
ETR1000 1250 2000 1300 1700
ETR2500 2500 2000 1300 1900
ETR4200 4200 2335 1320 2100

ELA O 162.2 EN EGE, spol. s r.o. Novohradská 34 37008 České Budějovice Czech Republic
Tel.: 00420 38 77 64 412, Fax: 00420 38 77 64 603, e-mail: elaobch@ege.cz, www.ege.cz
EGE, spol. s r.o.
Novohradská 34
370 08 České Budějovice
Czech Republic
www.ege.cz

Tel.: 00420 38 77 64 412


Fax.: 00420 38 77 64 603
E-mail: elaobch@ege.cz

You might also like