Professional Documents
Culture Documents
2-5)
This functional mode is used to check electrical continuity of wiring, a switch or other.
Warning: Checking any live part for continuity is not possible and such an attempt is
dangerous.
The buzzer sounds when the resistance at the check point is approximately below the range of
10-60 Ω. If the resistance exceeds the operating range of the buzzer, the buzzer does not
sound. If this is the case, use the resistance mode to measure the resistance and determine
whether the object under measurement has no continuity (i.e., whether the wire is broken).
The reading shows the resistance at the check point.
The open-circuit voltage of the connector is approximately 0.4 V.
(1) Set the Function key to Ω / / .
(2) Press the Select switch to display on the upper part of the readout.
(3) Make the test pines contact with the object under measurement and check for continuity
based on whether the buzzer sounds and the reading (400 Ω maximum).
Caution: To measure a capacitor with polarities (positive and negative), connect the red test
pin (positive measurement terminal) to the positive side of the capacitor.
Capacitor
3
COM +