UV Sterilizer
Model: UIV-10
FOR
COSCO(GUANGDONG)SHIPYARD CO.,LTD.
UT771WP
Hull No.: N603/N604/N605/N606/N607/N608/N634/N635
M14587
Version ( A.0 )
2015.1.6
Date: 2014-12 UV-STERILIZER
Rev: UIV-10
Table of contents
1.0 General
2.0 Specifications
3.0 Installation
3.1 Delivery
3.2 Positioning
3.3 Piping
3.4 Electric connections
3.5 Alarm extension
4.0 Operation
4.1 Initial start-up
4.2 Operation
4.3 Control cabinet
4.4 UV-lamps
6.0 Troubleshooting
-1–
Date: 2014-12 UV-STERILIZER
Rev: UIV-10
1.0 General
The UV unit is designed to provide disinfection to potable water onboard.
The whole system includes stainless steel UV chamber, UV sensor, UV-lamp, Quartz jacket,
solenoid valve, control cabinet.
The control system is arranged through a controller program, which collect information from UV
sensor and lamp monitors, so that the solenoid valve on output pipe can be controlled at such
conditions like the Lamp failure and the UV dosage lower, the solenoid valve will be closed , to
protect unqualified water passing through to potable water system; meanwhile , a lamp
running-hours accumulator will deliver alarm while running hours reaches to 7200 hours and valve
will be closed when running hours reaches 8000hrs.
2.0 Specifications
Model UIV-10
Capacity 10 m3/h
Number of lamps 5 pc
Type of lamp HS15
Voltage 220 VAC; 60 Hz
Power consumption 100 W
UV-dosage 36000 μWs/cm2
Alarm extension Potential-free, NO & NC available
Ambient temperature 5-45 ℃
Working pressure Max 10 bar
Material chamber Stainless steel 316L
3.0 Installation
3.1 Delivery
The unit is completely arranged inner piping and cabling, for piping there is only inlet and outlet to
be interfaced with user’s piping. Furthermore there is only power supply and alarm extension to be
connected.
3.2 Positioning
-2–
Date: 2014-12 UV-STERILIZER
Rev: UIV-10
The unit is to be positioned with certain space for maintenance, the space is enough for onsite
replacement of UV-lamp and quartz. The unit is to be positioned far from heavy vibration. For
detailed installation, please refer to drawing as illustrated.
3.3 Piping
The UV-Sterilizer is to be arranged close to hydrophore, boost pump, filter tank etc, and keep the
piping as short as possible to end user.
The unit of power supply is designed available to 220VAC & 60Hz, for other power source to be
further required. Please be advised that we can supply as option. For details, please refer to
electrical drawing.
4.0 Operation
Slowly open inlet valve, avoiding water impact to quartz and cause damage.
z Check no leakage
-3–
Date: 2014-12 UV-STERILIZER
Rev: UIV-10
4.2 Operation and description of panel
1. Start-up of UV Sterilizer
While start up the unit, it will take two minutes delay for opening of solenoid valve. So that
the UV lamp to be warmed up to maximum outputting.
When power on the unit, there should be intensity page illustrated upon initializing of
controller, detail as follow:
-4–
Date: 2014-12 UV-STERILIZER
Rev: UIV-10
1) Intensity of UV ray
This is the main page of unit, which will enter into this page upon star-up automatically,
the page intended for displaying of UV intensity. The page illustrates range of UV ray:
1%~100%. The system is running normally when UV ray stabilized within 50%~100%. If
UV intensity is less than 50%, an alarm occurs, solenoid valve to be shut off
simultaneously.
-5–
Date: 2014-12 UV-STERILIZER
Rev: UIV-10
This page displays the hour accumulation of lamp, which gives record accumulated
running hours of UV lamps. There is two time value designed, 7200 hours and 8000 hours
alternatively. When the UV lamp running is over 7200 hours, the system will give
attention to user for prepare spare of UV lamp. If 8000 hours running up, the system will
shut down the solenoid valve, and alarm occur.
3) Status of UV lamp
The system can control and monitor 5 UV lamps in maximum, which can illustrate the
status of each UV lamp. From right to left, which is corresponding to the status of
No.1~No.5 UV lamps interface channel. Each code of “O, F, X” stands for different
status of UV lamp. “O” stands for interface channel is normal. “F” stands for faulty of
subject channel is in faulty. “X” stands for non-use of subject channel. For example,
“XXXOF” stands for faulty of #1 interface channel, Normal of #2 channel and it’s non-use
of 3~5 channels.
Subject page displays the status of solenoid valve, if solenoid valve is open, which display
“Open”. If not, display “Close”.
5) Voltage of UV sensor
-6–
Date: 2014-12 UV-STERILIZER
Rev: UIV-10
For easy test and inspection, the system provides input voltage of UV sensor, the user can
test and inspect the function of system accordingly.
and then press to confirm the operation or press to cancel the operation.
The system provides 5 UV lamp interface channels in maximum, the user can define
certain channels. From right to left, which stands for the status of #1 to #5 channels, if the
value is “1” of corresponding bit, it means subject channel is occupied in use, if the value
is “0” of corresponding bit that means subject channel is un-use.
-7–
Date: 2014-12 UV-STERILIZER
Rev: UIV-10
The interface has the cursor which flashes, the in current operation port, user can move the
User wants to manually open or close solenoid valve for testing and commissioning. The
system provide subject page for this purpose, by pressing manually open or close
solenoid valve.
When user step out subject page, the control right will shift program automatically.
Faulty information
The system provides monitoring functions of status, intensity, running time for UV lamp. If
something wrong, an alarm caused or error code for user attention. When alarm occurs, which is to
be extended to remote terminal, and flashing on local panel for user attention. If user acknowledges
alarm, the lamp will light off.
1) Intensity low
UV intensity Low
Caused reason
z Defective of UV lamp
z Dirty of quartz jacket
z Dirty of UV sensor glass
z Defective of UV sensor
z Dirty water source
-8–
Date: 2014-12 UV-STERILIZER
Rev: UIV-10
2) Faulty of UV lamp
The system running over 7200 hours, the system will call use for stand-by of
replacement of UV-lamp. The use can still run the system till 8000 hours.
Subject page illustrated the UV-lamp is running over 8000 hours, the UV lamp must
change accordingly, and solenoid valve shut off automatically. Please reset hour meter
upon replacement of UV-lamp.
y The control cabinet is equipped with HSC-2, which arranged on cabinet cover, there is power
and alarm LED arranged on front of cover.
y The controller contains necessary information that displays in different manual bar, which
includes UV intensity, hour meter, trouble shorting, alarm list and contact information. There is
-9–
Date: 2014-12 UV-STERILIZER
Rev: UIV-10
arrow key available for page turning.
4.4 UV-lamps
The UV-lamps is specially made by Phillips, which fits adapter for easy connection. The UV-lamp
gives 8000 hours life, the UV ray reaches 254nm that specially designed for potable water
sterilizing.
The UV-Sterilizer should be carried out periodic maintenance, so that the unit is kept in regular
condition. When the UV-sterilizer running for long time, there is some dirties stained on the surface
of quartz jacket, this will cause UV ray reduced, and slow down the sterilizing capacity. Meanwhile
the sight quartz of UV-sensor is also to be carried out periodic cleaning, otherwise it will cause
drop-down of detecting accuracy.
Meanwhile please take care, the inlet and outlet valve must be position in close during cleaning
procedure. And be careful of dismounting, since quartz jacket and lamp is easy for crack, and
damage hands.
7. Close drain valve and open vent, slowly open inlet valve till venting of water on top, then
close vent and open inlet & outlet valve completely.
9. Check the displaying on controller screen, if no alarm. The unit is ready for use.
- 10 –
Date: 2014-12 UV-STERILIZER
Rev: UIV-10
7. Close drain and keep vent open, then open inlet valve slowly till vent over flow, then
close vent valve
10. Check the displaying on controller screen, if no alarm. The unit is ready for use.
The UV-lamp is to be replaced in period, every 8000 hours or the UV intensity is to be dropped to
certain level that activating alarm. Please change UV-lamp and keep UV-Sterilizer running in good
condition.
- 11 –
Date: 2014-12 UV-STERILIZER
Rev: UIV-10
4. Reset hour-meter on controller.
6.0 Troubleshooting
The troubleshooting illustrated as follow, please check and follow up when something wrong with
the unit. Meanwhile there is error message display, please refer to and take further action.
- 12 –
Date: 2014-12 UV-STERILIZER
Rev: UIV-10
- 13 –
Date: 2014-12 UV-STERILIZER
Rev: UIV-10
- 14 –
Date: 2014-12 UV-STERILIZER
Rev: UIV-10
2 O-ring 1 1B2711080
φ33.5*2.65
3 O-ring 1 1B2711081
φ46.2*1.8
4 O-ring 1 1B2711083
φ53*1.8
- 15 –