You are on page 1of 3

TEST RESULTS OF SAND SAMPLES

PROJECT: CONSTRUCTION OF KHATAM-UL-ANBIYA MOSQUE, JHAND-E-WALA, GUJRAT

DESCRIPTION OF %Age Passing % age through sieve size


MATERIAL

used
Original Grading 3/4” 1/2” 3/8” 4 8 16 30 50 100
Coarse aggregate I (3/4") 100 80 25 2 ----- ----- ----- ----- -----

Coarse aggregate II (1/2”) 100 100 85 25 5 1 ----- ----- -----

Coarse Sand ( Lawrencepur ) 100 100 98 97 94 82 58 27 9

Coarse aggregate I (3/4") 26% 26 20.8 6.5 0.54 ----- ----- ----- ----- -----

Coarse aggregate II (1/2”) 39% 39 39.6 33.1 9.75 1.95 0.39 ----- ----- -----

Coarse Sand ( Lawrencepur ) 35% 35 35 34.3 33.95 32.901 28.70 20.3 9.45 3.15

Combined Aggregate 100 100 95.4 73.9 44.24 34.851 29.09 20.3 9.45 3.15

Prepared by: Checked by


TEST RESULTS OF CEMENT SAMPLES

PROJECT: CONSTRUCTION OF KHATAM-UL-ANBIYA MOSQUE, JHAND-E-WALA, GUJRAT

Setting Time Compressive Strength Psi


Normal
Description Initial Time Final Time
Consistency
3 Days 7 Days
H M H M

D.G Cement 31 2 10 6 30 1900 3020

Not Less Than 30


Specified Limit --- Not Less Than 10 hours 1800 2800
Minutes

Prepared by: Checked by


TEST RESULTS OF AGGREGATE SAMPLES

PROJECT: CONSTRUCTION OF KHATAM-UL-ANBIYA MOSQUE, JHAND-E-WALA, GUJRAT

Los
Angeles Flakiness Elongation Sp. Water Sulphate Loose Unit Weight
Description of Material Abrasion % % Gravity Absorption % Soundness
Fines Modules
%
g/cc Lbs/Cft

Coarse Aggregate - I (3/4") 21.5 19.2 17.50 2.670 0.805 2.50 1.57 97.9 -----

Coarse Aggregate – II (1/2”) 23.6 21.5 19.70 2.66 0.825 3.90 1.55 96.7 -----

Fine Aggregate ----- ----- ----- 2.65 0.930 ----- 1.45 90.5 2.35

Prepared by: Checked by