You are on page 1of 2

Document ID: A173

Multigas detector 17 June2020


2020
Standard stock

Gas detector tubes Number Art No.

Gastec Multi Gas Pump (Gas Sampling Pump) 1 pc 414838

Gastec Handbook for Detector Tubes 1 pc 427087

Hydrogen Sulphide, 1 - 240 ppm (4L) 20 pcs 344207

Carbon Dioxide, 0.13 % - 6 % (2L) 20 pcs 427080

Carbon Dioxide, 2.5 % - 40 % (2HH) 20 pcs 427081

Carbon Monoxide, 5 - 600ppm (1LK) 10 pcs 427082

Arsine, 0.04 - 10 ppm (19LA) 20 pcs 427083

Phosphine, 0.15 - 5 ppm (7L) 20 pcs 427084

Methyl Bromide, 1 - 36 ppm (136LA) 20 pcs 427086

RKI Multigas detector Number Art No.

RKI GX-2009 GAS DETECTOR, LEL/O2/H2S/CO, WITH RECHARGABLE


BATTERIES, CHARGER, QUICK USER GUIDE, TRAINING CD, DATA 2 pcs 441868
LOGGING SOFTWARE
AUTOMATIC SAMPLE DRAW PUMP, FOR RKI GX-2009 2 pcs 676525

SAMPLING HOSE, 10 MTR FOR RKI GX-2009 2 pcs 681995

CALIBRATION ADAPTOR FOR RKI GX-2009


1 pc

414809

FIXED FLOW REGULATOR - 0.5L/MN (FOR RKI GX-2009) 1 pc 680123

QUAD CALIBRATION GAS MULTIMIX, FOR RKI GX-2009 (34 LTR) 2 pcs 414831

LOG BOOK FOR RKI GX-2009 2 pcs 435730

RKI GX-2009 Multigas detector spare parts

LEL / HC SENSOR FOR GX-2009 360755

CO SENSOR, SINGLE SENSOR FOR GX-2009 427146

H2S SENSOR, SINGLE SENSOR FOR GX-2009 476170

OXYGEN SENSOR FOR GX-2009 435735

SME department: Marine Standards – Cargo Management Page 1

Classification: Internal Uncontrolled copy when printed


Document ID: A173

Multigas detector 17 June2020


2020

Multigas detector spare parts (Obsolete detectors) Art No.

MICROTECTOR II G450 - Calibration Gas (34 LITERS) 435733

GASALERTMAX - Sampling hose (30 FT) for motorized pump with quick connect (D4- 345405
HSP-30)
GASALERTMAX - Calibration Kit, for GASALERTMAX w/ 1 QUAD Gas 34 LTR cylinder 345009
(CK-Q34)
GASALERTMAX - QUAD Calibration Gas (34 LTRS) (CG-Q34) 345391

GASALERTMAX - Training CD-ROM 345390

If equipped with another brand of multigas detector then above, this detector must as a
minimum be able to measure for LEL/O2/H2S/CO. A calibration kit for the specific detector
shall be available onboard.

If requested to carry commodities below deck involving other dangerous vapours than the
above equipment can detect, order additional detector tubes.
Each box of detector tubes is stamped with an expiration date. The tubes are suitable for
use until the last day of the month of expiration. Discard tubes that has past the expiry
date.
Stored the test tubes in the original package at a temperature between 1° C and 25° C.
Do not subject tubes to light for prolonged periods.

SME department: Marine Standards – Cargo Management Page 2

Classification: Internal Uncontrolled copy when printed