Professional Documents
Culture Documents
Business Unit Document Ref No.: Rev. No. Effective Date Page
No.
ECOALLY ECO-00318 00 08-Feb-2023 1 of 1
TECHNICAL SUBMITTAL
King Abdullah Road, Mergab District, Al Jubail, Kingdom of Saudi Arabia Tel: 013 3408341 Fax: 013 3408322 E-mail: info@ecoaly.com
www.ecoaly.com
شركة مصنع حليف البيئة المحدودة
ECOALLY FACTORY LLC
229415 غرفة تجارية2055026236 ت.س
C.R. 2055026236, C.O.C NO. 229415
VAT Number: 310406440800003
King Abdullah Road, Mergab District, Al Jubail, Kingdom of Saudi Arabia Tel: 013 3408341 Fax: 013 3408322 E-mail: info@ecoaly.com
www.ecoaly.com
USER MANUAL IP66 IK10
SOLAR STREET LIGHT
FEATURES
High pressure die cast aluminium alloy housing.
IEC62471
Double clip on closure, “Plug and Play” system suitable for SKD
USER MANUAL
TECHNICAL INFORMATION
ELECTRIC DATA
PHOTOMETRIC SPECIFICATIONS
Luminous Flux (±5%) 7750lm 13950lm 15500lm 18600lm 23250lm 310000lm 38750lm
CCT 3000K/4000K/5000/5500K
MECHANICAL SPECIFICATIONS
Working
-40oC~50oC, 20%~90% H.R
Environment
Lens Material PC
USER MANUAL
USER MANUAL
HIGH EFFICIENCY
FLEXIBILITY IK10
USER MANUAL
DISTRIBUTION CURVE
DIALUX
USER MANUAL
DIMENSIONS
USER MANUAL
INSTALLATION
MAINTENANCE
BATTERY
King Abdullah Road, Mergab District, Al Jubail, Kingdom of Saudi Arabia Tel: 013 3408341 Fax: 013 3408322 E-mail: info@ecoaly.com
www.ecoaly.com
DG12-200(12V200Ah)
Specification
Cells Per Unit 6
Voltage Per Unit 12
Capacity 200Ah@20hr-rate to 1.75V per cell @25℃
Weight Approx. 60.0 Kg (Tolerance±1.5%)
Internal Resistance Approx. 5.2 mΩ
Terminal F16(M8)/F10(M8)
Max. Discharge Current 2000A (5 sec)
DG (Deep Cycle GEL ) series is pure GEL
Design Life 15 years (floating charge)
battery with 15 years floating design life ,
Maximum Charging Current 40.0A it is ideal for standby or frequent cyclic
C3 136.5AH discharge applications under extreme
C5 151.5AH environments. By using strong grids, high
Reference Capacity purity lead and patented Gel electrolyte,
C10 174.0AH
C20 200.0AH the DG series offers excellent recovery
13.6 V~13.8 V @ 25℃
capability after deep discharge under
Float Charging Voltage frequent cyclic discharge use, and can
Temperature Compensation: -3mV/℃/Cell
deliver 450 cycles at 100% DOD. Suitable
14.2 V~14.4 V @ 25℃ for solar & wind system, CATV, marine,
Cycle Use Voltage Temperature Compensation: -4mV/℃/Cell
RV a n d d e e p d i s c h a r g e U P S , a n d
Discharge: -40℃~60℃ telecommunication, etc.
Operating Temperature Range Charge: -20℃~50℃
Storage: -40℃~60℃
Normal Operating Temperature Range 25℃±5℃
alve Regulated Lead Acid (VRLA) batteries can
be stored for up to 6 months at 25℃ and then recharging
Self Discharge is recommended. Monthly Self-discharge ratio is less
than 3% at 25℃.Please charged batteries before using.
Dimensions
Φ20 Length 522±1mm (20.6 inches)
205 M8 Width 240±1mm (9.45 inches)
522 240
Height 219±1mm (8.62 inches)
5
M5 6~7 N*m
M6 8~10 N*m
M8 10~12 N*m
F10 Terminal
Unit: mm
F.V/Time 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 8HR 10HR 20HR
1.60V 273.6 183.4 111.8 66.9 46.2 37.9 31.0 21.4 18.1 11.0
1.65V 268.0 181.8 111.3 66.4 46.1 37.7 30.8 21.2 17.9 10.6
1.70V 263.8 180.7 110.2 65.9 45.7 37.5 30.7 21.0 17.7 10.3
1.75V 254.1 177.9 109.2 65.4 45.5 37.2 30.3 20.8 17.5 10.0
1.80V 237.0 171.7 106.6 64.2 44.3 36.3 29.7 20.5 17.4 9.40
1.85V 215.0 162.4 101.3 61.4 42.3 34.6 28.5 19.6 16.8 9.00
F.V/Time 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 8HR 10HR 20HR
1.60V 502 348 215 131 91.8 75.3 61.7 42.5 36.0 19.5
1.65V 494 344 215 131 91.7 75.2 61.5 42.3 35.8 19.1
1.70V 488 345 213 130 91.3 75.0 61.3 42.0 35.4 18.8
1.75V 471 341 211 129 91.0 74.3 60.6 41.7 35.1 18.4
1.80V 440 330 207 127 88.5 72.6 59.5 41.0 34.7 18.1
1.85V 401 313 198 123 84.7 69.1 56.9 39.3 33.7 17.0
(Note) The above characteristics data are average values obtained within three charge/discharge cycle not the minimum values.
DG12-200(12V200Ah)
Discharge Characteristics Curve Charge Characteristic Curve for Cycle Use(IU)
Temperature:25℃(77℉) Temperature:25℃(77℉)
(V/cell)
120 0.14 2.50
Charge Volume
2.16
80 0.10 2.30
1.84
0.1C 0.05C
0.25C 0.17C 60 0.06 2.20
1.68 After 50% Discharge
0.50C
After 100% Discharge
2C 1C 40 0.04 2.10
1.52
Cycle Life in Relation to Depth of Discharge Relationship Between Charging Voltage and Temperature
120 2.60
100
2.50
Charge Voltage (v )
Cycle use
80
2.37~2.40VPC@25℃
Capacity(%)
2.40
60
100% 80% 50%
DOD DOD DOD 2.30
Float charging
40
2.27~2.30VPC@25℃
2.20
20
2.10
0 -20 -10 0 10 20 30 40 50
250 500 750 1000 1250 1500 1750
Number of Cycles Temperature (℃)
100 0℃
A
0 .0 5 C 80
Capacity (% )
Capacity (% )
80 0 .2 C A
60
10℃
60
20℃
1 .0 C A 40
40℃ 30℃
40
20
20
0 0
-20 -10 0 10 20 30 40 50 0 2 4 6 8 10 12 14 16 18 20 22 24
Temperature (℃) Storage Time(months)
Effect of Temperature on Long Term Life Relationship of OCV And State of Charge(20℃)
25 2.20
2.15
Battery Voltage (V)
Lift Expectancy (y ears)
20
2.10
2.05
15
2.00
10
1.95
1.90
5
1.85
0 1.80
0 10 20 30 40 50 0 10 20 30 40 50 60 70 80 90 100
Temperature(℃) State Of Capacity (%)
شركة مصنع حليف البيئة المحدودة
ECOALLY FACTORY LLC
229415 غرفة تجارية2055026236 ت.س
C.R. 2055026236, C.O.C NO. 229415
VAT Number: 310406440800003
CHARGE CONTROLER
King Abdullah Road, Mergab District, Al Jubail, Kingdom of Saudi Arabia Tel: 013 3408341 Fax: 013 3408322 E-mail: info@ecoaly.com
www.ecoaly.com
MPPT-DC series
MPPT Solar charge controller
with LED driver built-in
(Constant Current, Boost)
12/24V, 15/20A
200/260/400/520W
MPPT
User Manual
User Manual_MPPT-DC series_JA
CE, Rohs, ISO9001:2015
Subject to change without notice!
Solar charge controller MPPT-DC series User Manual
Dear Clients,
Thanks for selecting the MPPT-DC series solar controller. Please take the time to read this user manual, this will help you to take
advantage of controller’s new features. This manual gives important recommendations for installing, programming, using and so
on. Read it carefully in your own interest please.
1.Description of Function 3.Dimensions(Unit:mm)
MPPT-DC series intelligent MPPT solar controller is
2.5
2.5
Page 1 of 5 pages
Solar charge controller MPPT-DC series User Manual
When MPPT-DC series controller is connected to the Press the "Status" key of the S-unit to read the
system, you can setting the controller with S-Unit infrared running status of the controller.
remote controller, as shown below! Detailed setting
operations, please read S-Unit User Manual. Num Name Name describe Unit
Status: Charge
! Remark:Be sure to set only one MPPT-DC unit at a
Batter y voltage V 1 Batt V
time. Load current A
2 Load I
3 Load V Load voltage V
4 PV V PV voltage V
5 PV I PV current A
6 Energy Total generating capacity AH
7 OD Times Over discharge times Times
8 FC Times Fully charge times Times
9 Day1-HV A day ago highest voltage V
45°
10 Day1-LV A day ago lowest voltage V
11 Day2-HV Two days ago highest voltage V
12 Day2-LV Two days ago lowest voltage V
13 Day3-HV Three days ago highest voltage V
14 Day3-LV Three days ago lowest voltage V
4 Dim2 100%
6.2 System Voltage
5 Time3 0H The controller adjusts itself automatically to 12V or 24V
6 Dim3 100% system voltage. As soon as the battery voltage at the time
7 Time4 0H of start-up is within 10V to 15V, the controller implies a 12V
system, else if the battery voltage is within 20V to 30V, the
8 Dim4 0%
controller implies a 24V system.
9 Time5 0H If the battery voltage is not within the normal operating
10 Dim5 100% rang(ca.10 to 15V or ca.20 to 30V) at start-up, a status
11 D/N Thr 5.0V display according to the section 9.2Faults & Alarms occur.
Page 2 of 5 pages
Solar charge controller MPPT-DC series User Manual
D/N Dly The controller recognizes day and night based on the solar
array open circuit voltage. This day/night threshold can be
If “ Time1” is set to “D2D”,the controller works in
dusk to dawn mode. modified according to local light conditions and the solar
array used.
!
Day/Night threshold setting range: 3.0~20.0V.
1.MPPT-DC series controller is set to D2D mode, the
corresponding dimming setting is still valid.
In the evening, when the solar array open circuit
2. If “Time1”is set to D2D mode, “Time4” can not be
voltage reaches the setting day/night threshold, you
set to T0T mode.
can adjust the day/night delay time to make the load
turn on a little later.
7.2 Five-stage Night Mode Day/Night delay time setting range: 0~30min.
D/N Thr
D/N Thr
Sunrise Sunset Sunrise
Sunset
Light on 4.0~21.0V
3.0~20.0V
Light off
You can set the Time 1-5 and Dim 1-5 with S-Unit. !
1. Day/Night threshold voltage should be set around
0.22 times of open circuit voltage.
7.3 T0T mode ( can set the load on time before 2.Day/Night threshold voltage of load disconnect is 1V
morning coming )
higher than the setting data, means the load will disconnect
D/N Thr when the solar voltage at 4.0~21.0V.
D/N Thr
3.The controller has an automatic day/night threshold
Sunset Sunrise
adjustment function. If the lowest voltage of solar array is
Light on higher than the setting day/night threshold, the load has no
Light off output in first night, 24 hours later the controller can
automatically adjust the day/night threshold to meet the
D/N Dly Time1 Time2 Time3 T0T Time5
requirements of lighting at night.
If "Time4" of the S-Unit is set to "T0T", this mode is T0T 8.4 Auto Dimming
mode.
* If “Time4”is set to T0T mode, “Time1” can not set to The "Dim Auto" item of S-Unit is set to "Yes", set "Dim V"
D2D mode. and "Dim %" at the same time, press the "Send" key to set
up the controller. when the battery voltage is lower than the
voltage of "Dim V" , it starts to dimming automatically.
Battery voltage reduces per 0.1/0.2V, load current decreased
according to the set of "Dim %", the minimum output
current is 10% of the setting current.
!
1.”Dim V”setting range: 11.8~12.5V/23.6~25.0V.
2. If the controller is set to “Dim” or “Auto Dim”, the
minimum output current can be as low as 100mA.
Page 3 of 5 pages
Solar charge controller MPPT-DC series User Manual
Reverse
Green LED
polarity Protected *1 Protected Protected
R eceiver
Yellow LED Emitting
9.1LED Display Explanation Switches off
Red LED Short circuit Protected Protected *1 immediately
LED Status Function Switches off
Over current with delay
Solar panel is correctly
On connected,
Reverse
but not charged Protected
Current
Green Fast flash(0.1/0.1s) MPPT charging
Over voltage Max.55V *2 Max. 35V
LED Flash(0.5s/0.5s) Equal or Boost Charging
Under
voltage Switches off
Slow flash(0.5/2s) Float Charging
Off Over voltage protection Over temp. The controller cuts off the load if the
temperature reaches the set value.
Yellow On Battery is normal
LED
Slow flash(0.5/2s) Batter y voltage is low *1.Battery must be protected by fuse, otherwise battery will
Fast flash(0.1/0.1s) Low voltage protection be damaged.
*2.The solar panel voltage should not exceed this limit for a
Off Work normal
long time.
On The output power is 0.
Red
Super slow(0.2/5s) Open circuit protection
! Warning: The combination of different error
LED
conditions may cause damage to the controller.
Flash(0.5s/0.5s) Over temperature
Always remove the error before you continue connecting
Short circuit or * the controller.
Fas t flas h( 0. 1/ 0. 1s )
Over current protection
Page 4 of 5 pages
Solar charge controller MPPT-DC series User Manual
12.Technical Data
*1.This value represents the maximum voltage of the solar panel at the minimum operating ambient
temperature.
*2.Voc means the open circuit voltage of the solar panel.
*3.Around oblique line value separately on behalf of 12V and 24V system's value.
Page 5 of 5 pages
شركة مصنع حليف البيئة المحدودة
ECOALLY FACTORY LLC
229415 غرفة تجارية2055026236 ت.س
C.R. 2055026236, C.O.C NO. 229415
VAT Number: 310406440800003
PANEL
King Abdullah Road, Mergab District, Al Jubail, Kingdom of Saudi Arabia Tel: 013 3408341 Fax: 013 3408322 E-mail: info@ecoaly.com
www.ecoaly.com
IP65
POLYCRYSTALINE SOLAR PANEL
TEMPERATURE COEFFICIENTS
Noct : 48 °C ± 2 °C
Current temperature coefficient:
0.06 ± 0.01%/K
Voltage Temperature coefficient:
(78 ± 10)MV/K
Power Temperature coefficient :
-(0.5 ± 0.05) %/K
CHARACTERISTICS
Solar Cell: Polycrystalline silicon solar cell 156 x 156mm(6inch)
Warranty: Pm is not less than 90% in 10 years and 80% in 25 years
Junction Box: IP65 rated
Resistances: 227g steel ball fall down from 1m height and 60m/s wind.
Operating temperature: 40 oC to +85 oC
Maximum system voltage - 1000V
Standard Test Condition - Irradiance 1000W/m², module temperature
25 °C, AM=1.5
PRODUCT SPECIFICATION
Maximum Voltage at Current at Open circuit Short circuit Maximum
Power
Product power max power max power Voltage current Series Fuse
Tolerance
(Pm) (Vmp) (Imp) (Voc) (Isc) Rating
MECHANICAL CHARACTERISTICS
No. of Cells and connections: 36 = 4x9 pcs
Dimension of module: 1260 x 670 x 25mm (49.6 x 26.4 x 1.2inch)
Weight: 11.5kg
Packing configuration: 2pcs/ctn, 1290 x 700x 80mm (50.8 x 27.5 x 3.15inch)
PRODUCT SPECIFICATION
Maximum Voltage at Current at Open circuit Short circuit Maximum
Power
Product power max power max power Voltage current Series Fuse
Tolerance
(Pm) (Vmp) (Imp) (Voc) (Isc) Rating
MECHANICAL CHARACTERISTICS
No. of Cells and connections: 36 = 4x9 pcs
Dimension of module: 1480 X 670 X 25mm (58.3 x 26.4 x 1.2inch)
Weight: 13.5kg
Packing configuration: 2pcs/ctn, 1510 x 700x 80mm (59.5 x 27.5 x 3.15inch)
PRODUCT SPECIFICATION
Maximum Voltage at Current at Open circuit Short circuit Maximum
Power
Product power max power max power Voltage current Series Fuse
Tolerance
(Pm) (Vmp) (Imp) (Voc) (Isc) Rating
MECHANICAL CHARACTERISTICS
No. of Cells and connections: 60 = 6 x 10 pcs
Dimension of module: 1640 x 992 x 40mm (64.5 x 39 x 2 inch)
Weight: 24.50kg
Packing configuration: 2 pcs/cnt, 1670 x 1020 x 120 mm (65.7 x 40.1 x 4.7 inch)
PRODUCT SPECIFICATION
Maximum Voltage at Current at Open circuit Short circuit Maximum
Power
Product power max power max power Voltage current Series Fuse
Tolerance
(Pm) (Vmp) (Imp) (Voc) (Isc) Rating
MECHANICAL CHARACTERISTICS
No. of Cells and connections: 72 = 6 x 12 pcs
Dimension of module: 1480 X 992 X 40mm (76.8 X 39 X 2 inch)
Weight: 15 kg
Packing configuration: 2pcs/ctn, 1510 x 1020 x 90 mm
PRODUCT SPECIFICATION
Maximum Voltage at Current at Open circuit Short circuit Maximum
Power
Product power max power max power Voltage current Series Fuse
Tolerance
(Pm) (Vmp) (Imp) (Voc) (Isc) Rating
MECHANICAL CHARACTERISTICS
No. of Cells and connections: 72 = 6 x 12 pcs
Dimension of module: 1956 X 992 X 40mm (76.8 X 39 X 2 inch)
Weight: 26.5 kg
Packing configuration: 2pcs/ctn, 1980 x 1020 x 120 mm (78 x 40.1 x 4.7 inc
METAL BOX
King Abdullah Road, Mergab District, Al Jubail, Kingdom of Saudi Arabia Tel: 013 3408341 Fax: 013 3408322 E-mail: info@ecoaly.com