Professional Documents
Culture Documents
USER MANUAL
Thank you for choosing RUIDE theodolite RT-2.
Please read this manual carefully before use.
PRECAUTIONS
a. Do not collimate the objective lens directly to the sun without a filter.
c. When the instrument is not in use, store it in the case and avoid shock, dust and humidity.
d. If there is great difference between the temperature in work site and that in store place, leave the
e. If the instrument will not be used for a long time, remove the battery for separate storage. The
g. For better accuracy, the instrument should be set up on a wooden tripod rather than an aluminum
tripod.
h. Clean those exposed optical parts with degreased cotton or tissue only.
i. Clean the instrument surface with a woolen cloth after use. If it gets wet, dry it immediately.
j. Before turning on, inspect the power, functions and indications of the instrument as well as its initial
k. Do not attempt to disassemble the instrument without professional technical support and guidance.
m. Keep the screen clean. Do not scratch the screen with sharp objects.
1. PART NAMES
Key Function
◄ Move Left.
► Move right.
HOLD Hold the value of horizontal angle.
▲ Move up.
▼ Move down.
SET Setting
Power
2.2 Signs on Screen
Signs Meaning
Power status
H Horizontal angle
V Vertical angle
3.3.3 Value/Slope
Press V/% to shift the display mode of vertical angle between value
and slope.
dms mil
gon
4.5 Minimum Change of Angle
Change the minimum change of the angle as below. Press ▲, ▼ (HOLD,
V/%) to shift different options, and then press SET to confirm the setting.
Step 1 Step 5
dms 1” 5”
gon 0.00.05 0.00.15
mil 0.05 0.10
Step 2: Rotate the theodolite to Face Right (Face 2), collimate the crosshair
center of a collimator and adjust the focus until it seems clearly. Press 0SET.
The system will correct the error and return to the display of Face Left (Face 1).
However, if the error is too big to correct, an error code “E-20” will show. If so,
press V/% to return to calibration again, and repeat the above steps until the
error is corrected.
6. SPECIFICATION
TELESCOPE
Image Erect
Magnification 26.5X
Resolution 3”
Length 155mm
ANGLE
Accuracy 2”
Minimum Reading 1”
LEVEL
COMPENSATOR
Range +3’
Resolution 3”
DISPLAY
INTERFACE
N/A N/A
POWER
Voltage 7.4V
Working Time 8h
ENVIRONMENT
Weight 4.7kg
7. ERROR CODE
Error Code Cause
Restart the theodolite. If it is not solved, return to your local dealer for further
inspection.
http://www.ruide.xyz
support@ruideinstrument.com