www.tyco-fire.com
Contacts
IMPORTANT
Technical Button ������������������������������������������� Brass/Copper
Sealing Assembly ��������������������������������� Beryllium
Refer to Technical Data Sheet
TFP2300 for warnings pertaining to
Data Nickel w/TEFLON
Bulb ������������������������������������������������������������� Glass
Compression Screw ���������������������������������Bronze
regulatory and health information. Approvals Deflector �������������������������������������������������� Copper
UL and C-UL Listed Shield �����������������������������������������������Plated Steel
Always refer to Technical Data
Sheet TFP700 for the “INSTALLER FM and NYC Approved
WARNING” that provides cautions (See Table A for complete approval informa-
with respect to handling and instal- tion including corrosion resistant status.)
lation of sprinkler systems and com- Maximum Working Pressure
ponents. Improper handling and 175 psi (12,1 bar)
installation can permanently damage
a sprinkler system or its compo- Discharge Coefficient
nents and cause the sprinkler to fail K = 5.6 gpm/psi½ (80,6 Lpm/bar½)
to operate in a fire situation or cause K = 8.0 gpm/psi½ (115,2 Lpm/bar½)
it to operate prematurely.
* Temperature rating is indicated on deflector, ** Pipe thread connections per ISO 7-1 can be
shield, or adjacent to orifice seat on frame. provided on special request.
7/16" UPRIGHT
(11,1 mm) SHIELD * 2-3/16"
2-3/8"
NOMINAL WRENCH MODEL S2 (55,6 mm)
(60,3 mm)
MAKE-IN FLATS SHIELD
WRENCH
FLATS
* Temperature rating is indicated on deflector, ** Pipe thread connections per ISO 7-1 can be
shield, or adjacent to orifice seat on frame. provided on special request.
TABLE A
LABORATORY LISTINGS AND APPROVALS
Operation Design
The glass bulb contains a fluid which
expands when exposed to heat. When
Criteria
the rated temperature is reached, the The Series TY-B Pendent and Upright
fluid expands sufficiently to shatter the Intermediate Level Sprinklers are
glass bulb, allowing the sprinkler to intended for fire protection systems
activate and water to flow. designed in accordance with the stan-
dard installation rules recognized by the
applicable Listing or Approval agency
(for example, UL Listing is based on
the requirements of NFPA 13, and FM
Approval is based on the requirements
of FM’s Loss Prevention Data Sheets).
TFP351
Page 4 of 6
TEMPERATURE
SIN SPRINKLER
RATING
533 5.6K UPRIGHT (1/2 in. NPT) TY3153 1 NATURAL BRASS 135 135°F (57°C)
543 8.0K UPRIGHT (3/4 in. NPT) TY4153 7 LEAD COATED 155 155°F (68°C)
TABLE B
SERIES TY-B UPRIGHT INTERMEDIATE LEVEL SPRINKLERS
PART NUMBER SELECTION
(Upright Shield Included With Sprinkler)
TEMPERATURE
SIN SPRINKLER
RATING
571 5.6K PENDENT (1/2 in. NPT) TY3251 1 NATURAL BRASS 135 135°F (57°C)
WAX COATED
591 8.0K PENDENT (3/4 in. NPT) TY4251 6 155 155°F (68°C)
286°F (141°C) MAXIMUM
TABLE C
SERIES TY-B PENDENT SPRINKLERS
PART NUMBER SELECTION
(Model S2 Pendent Shield & O-Ring Must Be Separately Ordered)
NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association;
TEFLON is a registered trademark of DuPont