CODE B

1. All exhaust grill location and sizes should be as per approved MEP composite layout.
2. Submit separate HVAC layout for Mechanical and Pump room.
3. Exhaust fan locations, capacities, duct sizes and pressure losses should be as per IFC drawings and equipment
schedule.
4. Fire dampers to be provided in the main duct while all branches to be equipped with VD.
5. Coordination with other disciplines is contractor's responsibility.
GENERAL NOTES

LEGEND:

A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1
Y X W V U T' T S R Q P' P O N M L K J I H G G' F E D C B A

A1
1

RAMP RAMP

WELL COMPACTED FILL WELL COMPACTED FILL

MATCHLINE
FFL -2.05

RAMP RAMP

A1
2"
KEYPLAN:
A1
2
FLAKTWOODS
EF-1A

FAN ROOM 06
BF.46 STORAGE 15 I.T. STORAGE STORAGE 07 STORAGE 08 PCD CAFETERIA PCD STATIONARY
A1
Y
A1
X
A1
W
A1
V
A1
U
A1 A1
T' T
A1
S
A1
R
A1
Q
A1 A1
P' P
A1
O
A1
N
A1
M
A1
L
A1 A1
K J
A1
I
A1
H
A1 A1
G G'
A1
F
A1
E
A1
D
A1
C
A1
B
A1
A

STORAGE 16 BF.18 BF.18A STORAGE


BF.50 BF.22 STORAGE A1
1

FFL -2.70 BF.51 BF.19 WATER TANK 01


BF.20
FFL -1.85 FFL -1.85 BF.24 A1
2"
A1
2

FFL -2.70 FFL -1.85 FFL -1.85 FFL -1.85 FFL -2.70 B.O.PIT -4.95 CL -2.85 A1
3

A1
4

A1 UP

3
PART-1 PART-2 FE1
A1
5

PE7
A1
6

A1
7

A1
8

A1
9
A1
10
A1

PE4

PE1
10'

PE5

PE2
PUMP ROOM WATER TANK 02

PE6

PE3
A1

FFL -2.05 11

BF.17
PART-4 PART-3
A1

BF.25 12
A1
13

RAMP FFL -2.05 RAMP FFL -2.70 UP


A1
14

CL -2.85
A1
15

FFL -2.85
FFL -2.85 FFL -2.85 FFL -2.05

K
A1
16

FFL -2.70 A1
17

A1
4
PCD DOCUMENT ARCHIVE
A
STAIR 07 BF.13

3
4
5
6
BF.45
STAIR 08
BF.48
DATA RM.
BF.49A
FFL -1.70
B
FAN ROOM 01

E EE ROOM
2
FAN ROOM 08
EF-1A

1
BF.21
FLAKTWOODS
6
UP 5
BF.49 EF-1A

BF.52
FLAKTWOODS
AHU ROOM 02 UP
4 BF.16 5 4 3 2 1
STO. 05
3
FFL -1.85 FFL -1.85
2 BF.14
1 STAIR 02
FFL -2.70 BF.12

C
FFL -2.70 UP FFL -2.70

GF.28
FFL -1.85

A1 STAIR 03
A1
5 STORAGE 5
BF.26
BF.27
6
FFL -2.70

J
5
FAN ROOM 07 EF-1A

FLAKTWOODS
EE ROOM STO. 04 4

BF.47 BF.09 BF.11 B.O.PIT -3.95


3
FE1 2

FFL -2.70 1

STO. 03 UP
BF.10 PE7 FFL -2.70

AHU ROOM DETAIL SHALL BE


SUBMITTED SEPERATELY
FFL -2.70

FFL -5.50
VIP ENTRANCE LOBBY
BF.08
FFL -1.85
A1 A1
6 6

A1 MATCHLINE MATCHLINE A1
7 7 NAME:
FFL -1.85 FFL -2.05
SIGNATURE/
DATE:
FFL -2.85 FFL -1.85

A1
8
A1
8 A Approved As Submitted D Disapproved
PARKING PARKING AHU ROOM 01 PARKING
BF.01 FFL -2.85 BF.01 BF.07 BF.01 Approved as Noted No Action Taken
B E
F Resubmission not required
C Resubmission required
FFL -2.70
FFL -1.85
A1 A1
9 B.O.PIT -4.95 B.O.PIT -4.95 9
SUMP PIT 03
BF.43 SUM PIT
SUMP PIT 02 01
BF.34 FFL -1.85 BF.28
A1 A1
10 10
A1 B.O.PIT -4.95
A1

AHU ROOM DETAIL SHALL BE


10' B.O.PIT -3.95 10'

PE4

PE1

SUBMITTED SEPERATELY
FFL -1.85
B.O.PIT -3.95 18-02-2020 01 CONSULTANT COMMENTS INCORPORATED
FFL -2.05 ELEVATOR 26-01-2020 00 ISSUED FOR APPROVAL

PE5

PE2
LOBBY
BF.02
DATE REVISION NO. REMARKS
FFL -2.05
FFL -2.85 FFL -2.85
CLIENT

PE6

PE3
A1 A1
11 FFL -1.85 11

STORAGE
BF.29A
A1 A1 [T] +966 26681765
12 AHU ROOM 01 12
AHU ROOM 01 BF.03 [F] +966 26681732
FAN ROOM 04 BF.04
BF.38 FAN ROOM 03 P.O. Box 3896 - Jeddah 21481
A1 EF-1A

BF.35
FLAKTWOODS

A1
ARCHITECTS & INTERIORS [E] info@kaosarchitects.com
FLAKTWOODS EF-1A

13 FFL -1.85 13
FFL -2.70

A1
FFL -1.85

STAIR 01
D FAN ROOM 02
BF.29 A1
BF.05 STO. 06 EF-1A

14 BF.15 FFL -1.85


FLAKTWOODS

14
FFL -2.70 5 4 3 2 1

UP

UP
1
2
3
4
FFL -1.70 MEP CONSULTANT
5
6
STO. 14 FFL -1.85
BF.40 STORAGE 02
BF.06 STORAGE
STAIR 05 BF.29B
BF.39 FFL -2.70

GF.04
FFL -2.70

GF.03
FFL -1.85
A1 RAMP UP A1 PROJECT MANAGEMENT & SUPERVISION
15 1 15
2 M I D D
3

L
H
4

E E A S
5
6

FFL -2.70
FFL -2.05 STAIR 04 T
FFL -2.05
BF.30
FFL -2.85
RAMP FFL -2.05 RAMP FFL -2.85
CONTRACTOR

FFL -2.70
FFL -2.85
Al Saad General ContractinG Limited Liability Co.

A1 A1 P.O. Box 13028, Jeddah 21493, Saudi Arabia


16 16
P.O. Box 16910, Riyadh 11474, Saudi Arabia
UP
1
STORAGE 13 STORAGE 12 LEGAL ARCHIVE ROOM
2
3 BF.37 BF.36 BF.33 STORAGE 09 JOB NUMBER
4 BF.31
5
FAN ROOM 05
6

STAIR 06
BF.41
FFL -2.70
FFL -2.70 FFL -1.85
FFL -1.85 FFL -2.70
2013-154
FLAKTWOODS

BF.42
EF-1A

A1 I A1
PROJECT NAME
17 17
ZAHID BUSINESS PARK
MATCHLINE

LOCATION: PLOT NUMBER


JEDDAH KSA
DESIGN BY -
1. All exhaust grill location and sizes should be as per ARCHITECT TK

approved MEP composite layout. STRUCTURAL ENGINEER


ELECTROMECHANICAL ENGINEER
MF
RM
2. Submit separate HVAC layout for Mechanical and Pump DRAWN: KS

room. CHECKED: -
DESIGN PHASE
3. Exhaust fan locations, capacities, duct sizes and pressure CONSTRUCTION PHASE CP
losses should be as per IFC drawings and equipment REVISION NUMBER
schedule. REVIEW CYCLE: 001
4. Fire dampers to be provided in the main duct while all FORMAT SCALE DATE

branches to be equipped with VD. A0 1:200 FEB.18.2020

5. Coordination with other disciplines is contractor's DRAWING TITLE AND NUMBER

responsibility. HEADQUARTERS
OVERALL BASEMENT FLOOR PLAN
HVAC SYSTEM LAYOUT
CODE B
DRAWING NUMBER
TRANSMITTAL #:
ZBP-V3-ALSAAD-HQ-DWG-SD-MC-016-REV-1
ZBP/HQ/SD/M1A-101
SIZE A0 841MM x 1189MM
GENERAL NOTES

LEGEND:
A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1
Y X W V U T' T S R Q P' P

A1
1

WELL COMPACTED FILL

MATCHLINE
A1
2"
A1
2 KEYPLAN:
FLAKTWOODS

EF-1A

FAN ROOM 06
A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1
Y X W V U T' T S R Q P' P O N M L K J I H G G' F E D C B A

A1
1

BF.46 STORAGE 15 A1

STORAGE 16
2"
A1
2

BF.50
A1
3

FFL -2.70 BF.51 UP


A1
4

PART-1 PART-2 FE1


A1
5

PE7
A1
6

FFL -2.70 FFL -1.85 A1


7

A1
8

A1
9

A1
10

PE4

PE1
A1
10'

PE5

PE2
PE6

PE3
A1
11

PART-4 PART-3
A1

A1
12
A1
13

A1
14
UP

3 A1
15

A1
16

A1
17

FFL -2.05
RAMP

FFL -2.85 FFL -2.85


FFL -2.70

A1
4
STAIR 07
BF.45 DATA RM.
STAIR 08 BF.49A
6
5 BF.48
4
3

E EE ROOM
2
1 6 FAN ROOM 08
UP 5
BF.49 BF.52
EF-1A
FLAKTWOODS

4
3
NAME:
FFL -1.85
2 SIGNATURE/
1

FFL -2.70 DATE:


FFL -2.70 UP FFL -2.70
A Approved As Submitted D Disapproved
Approved as Noted No Action Taken
B Resubmission not required E
A1 C Resubmission required
5

FAN ROOM 07 EF-1A

FLAKTWOODS

BF.47
FFL -2.70

18-02-2020 01 CONSULTANT COMMENTS INCORPORATED


26-01-2020 00 ISSUED FOR APPROVAL
DATE REVISION NO. REMARKS

CLIENT

A1 [T] +966 26681765

6 [F]
P.O. Box
+966 26681732
3896 - Jeddah 21481

ARCHITECTS & INTERIORS [E] info@kaosarchitects.com

A1 MATCHLINE MEP CONSULTANT


7

PROJECT MANAGEMENT & SUPERVISION


M I D D

L
E E AS
T

CONTRACTOR
Al Saad General ContractinG Limited Liability Co.

P.O. Box 13028, Jeddah 21493, Saudi Arabia


P.O. Box 16910, Riyadh 11474, Saudi Arabia

JOB NUMBER

2013-154
PROJECT NAME

ZAHID BUSINESS PARK


1. All exhaust grill location and sizes should be as per approved
MEP composite layout. LOCATION:
JEDDAH KSA
PLOT NUMBER

2. Submit separate HVAC layout for Mechanical and Pump room. DESIGN BY -
3. Exhaust fan locations, capacities, duct sizes and pressure ARCHITECT TK

losses should be as per IFC drawings and equipment schedule.


STRUCTURAL ENGINEER MF
ELECTROMECHANICAL ENGINEER RM
4. Fire dampers to be provided in the main duct while all DRAWN: KS

branches to be equipped with VD. CHECKED: -


DESIGN PHASE
5. Coordination with other disciplines is contractor's CONSTRUCTION PHASE CP
responsibility. REVISION NUMBER
REVIEW CYCLE: 001
CODE B FORMAT SCALE DATE

A0 1:100 FEB.18.2020
DRAWING TITLE AND NUMBER

HEADQUARTERS
BASEMENT FLOOR PLAN
SECTION - E HVAC SYSTEM LAYOUT-PART-1

TRANSMITTAL #: DRAWING NUMBER


ZBP-V3-ALSAAD-HQ-DWG-SD-MC-016-REV-1 ZBP/HQ/SD/M1A-101A
SIZE A0 841MM x 1189MM
GENERAL NOTES

A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1
O N M L K J I H G G' F E D C B A

A1
1

RAMP RAMP

WELL COMPACTED FILL WELL COMPACTED FILL


MATCHLINE

FFL -2.05

LEGEND:
RAMP RAMP

A1
2"
A1
2

I.T. STORAGE STORAGE 07 STORAGE 08 PCD CAFETERIA PCD STATIONARY


BF.22 BF.18 BF.18A STORAGE STORAGE
BF.19 BF.20 WATER TANK 01
FFL -1.85 FFL -1.85 BF.24
FFL -1.85 FFL -1.85 FFL -2.70 B.O.PIT -4.95 CL -2.85

A1
3

PUMP ROOM WATER TANK 02


BF.17 BF.25
FFL -2.05 RAMP FFL -2.70
CL -2.85
KEYPLAN:
FFL -2.85
FFL -2.05

K
A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1
Y X W V U T' T S R Q P' P O N M L K J I H G G' F E D C B A

A1
1

A1
2"
A1
2

A
A1
3

A1
4

UP

A1 PART-1 PART-2 FE1


A1
5

PE7
4
A1
6

A1
7

PCD DOCUMENT ARCHIVE


A1
8

A1
9

A1

BF.13

B
10

PE4

PE1
A1
10'

PE5

PE2
PE6

PE3
A1
11

PART-4 PART-3
A1
12
A1
13

A1
14
UP

A1
15

FFL -1.70 A1
16

A1
17

FAN ROOM 01 EF-1A

BF.21
FLAKTWOODS

AHU ROOM 02 UP
BF.16 5 4 3 2 1
STO. 05 FFL -1.85
BF.14
STAIR 02
BF.12

C
GF.28

FFL -1.85

STAIR 03
A1
STORAGE 5
BF.26
BF.27
6
FFL -2.70

J
5
EE ROOM STO. 04 4
BF.09 BF.11 B.O.PIT -3.95
3
FE1 2
1

STO. 03 UP
BF.10 PE7 FFL -2.70
AHU ROOM DETAIL SHALL BE
SUBMITTED SEPERATELY

FFL -2.70
NAME:
FFL -5.50 SIGNATURE/
VIP ENTRANCE LOBBY DATE:
BF.08
FFL -1.85
A1 A Approved As Submitted D Disapproved
6
Approved as Noted No Action Taken
B Resubmission not required E
C Resubmission required

FFL -1.85 FFL -2.05


MATCHLINE
J A1
7

18-02-2020
26-01-2020
DATE

CLIENT
REVISION NO.
01
00
CONSULTANT COMMENTS INCORPORATED
ISSUED FOR APPROVAL
REMARKS

[T] +966 26681765


[F] +966 26681732
P.O. Box 3896 - Jeddah 21481

ARCHITECTS & INTERIORS [E] info@kaosarchitects.com

MEP CONSULTANT

PROJECT MANAGEMENT & SUPERVISION


M I D D

L
E E AS
T

SECTION - A SECTION -B SECTION -C MAT FOUNDATION


EL. -2.85
CONTRACTOR
Al Saad General ContractinG
160CM THK. Limited Liability Co.
MAT FOUNDATION
MAT FOUNDATION 800CM THK.
80CM THK. P.O. Box 13028, Jeddah 21493, Saudi Arabia
P.O. Box 16910, Riyadh 11474, Saudi Arabia

A
JOB NUMBER

50000
2013-154
PROJECT NAME
SECTION -J ZAHID BUSINESS PARK

LOCATION: PLOT NUMBER


1. All exhaust grill location and sizes should be as per JEDDAH KSA

approved MEP composite layout. DESIGN BY -


ARCHITECT TK
2. Submit separate HVAC layout for Mechanical and Pump STRUCTURAL ENGINEER MF
room.
FLAKTWOODS
ELECTROMECHANICAL ENGINEER RM

3. Exhaust fan locations, capacities, duct sizes and pressure DRAWN:


CHECKED:
KS
-
losses should be as per IFC drawings and equipment
EF-1A-7
DESIGN PHASE

schedule. CONSTRUCTION PHASE CP

4. Fire dampers to be provided in the main duct while all REVISION NUMBER

branches to be equipped with VD. REVIEW CYCLE: 001

MAT FOUNDATION 5. Coordination with other disciplines is contractor's FORMAT SCALE DATE
160CM THK.
A0 1:100 FEB.18.2020
responsibility. DRAWING TITLE AND NUMBER

HEADQUARTERS
CODE B BASEMENT FLOOR PLAN
50000

HVAC SYSTEM LAYOUT-PART-2


SECTION -K
SECTION -K TRANSMITTAL #: DRAWING NUMBER
ZBP-V3-ALSAAD-HQ-DWG-SD-MC-016-REV-1 ZBP/HQ/SD/M1A-101B
SIZE A0 841MM x 1189MM
GENERAL NOTES

A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1
O N M L K J I H G G' F E D C B

MATCHLINE A1
7
FFL -1.85 FFL -2.05

FFL -1.85

A1
8
PARKING AHU ROOM 01 PARKING
BF.01 BF.07 BF.01 LEGEND:

FFL -1.85
A1
B.O.PIT -4.95 B.O.PIT -4.95 9
SUM PIT
SUMP PIT 02 01
BF.34 FFL -1.85 BF.28
A1
10
A1

AHU ROOM DETAIL SHALL BE


B.O.PIT -3.95 10'

PE4

PE1

SUBMITTED SEPERATELY
FFL -1.85
B.O.PIT -3.95
FFL -2.05 ELEVATOR

PE5

PE2
LOBBY
BF.02

FFL -2.05
FFL -2.85

PE6

PE3
KEYPLAN:

A1 A1
Y
A1
X
A1
W
A1
V
A1
U
A1 A1
T' T
A1
S
A1
R
A1
Q
A1 A1
P' P
A1
O
A1
N
A1
M
A1
L
A1 A1
K J
A1
I
A1
H
A1 A1
G G'
A1
F
A1
E
A1
D
A1
C
A1
B
A1
A

FFL -1.85 11 A1
1

A1
2"
A1
2

A1
3

A1
4

UP

PART-1 PART-2 FE1


A1
5

PE7
STORAGE A1
6

A1
7

BF.29A A1
8

A1 A1
9

A1
10
A1

PE4

PE1
10'

12

PE5

PE2
AHU ROOM 01

PE6

PE3
A1
11

PART-4 PART-3
A1
12
A1

AHU ROOM 01
13

BF.03 UP
A1
14

BF.04
A1
15

A1
16

A1
A1
17

FFL -1.85 13

STAIR 01
D FAN ROOM 02
BF.29 A1
BF.05 STO. 06 EF-1A

BF.15
FLAKTWOODS

FFL -1.85 14
5 4 3 2 1

UP

FFL -1.70

FFL -1.85
STORAGE 02
BF.06 STORAGE
BF.29B
FFL -2.70
GF.04

FFL -2.70
GF.03

FFL -1.85
RAMP UP A1 NAME:
1 15
2 SIGNATURE/
3
DATE:

H
4
5
6
A Approved As Submitted D Disapproved
FFL -2.05 STAIR 04 Approved as Noted
B E No Action Taken
BF.30 Resubmission not required

RAMP
C Resubmission required
FFL -2.05 FFL -2.85

18-02-2020 01 CONSULTANT COMMENTS INCORPORATED


A1 26-01-2020 00 ISSUED FOR APPROVAL
16 DATE REVISION NO. REMARKS

CLIENT
LEGAL ARCHIVE ROOM
BF.33 STORAGE 09
BF.31

FFL -1.85 FFL -2.70 [T] +966 26681765


[F] +966 26681732
P.O. Box 3896 - Jeddah 21481

ARCHITECTS & INTERIORS [E] info@kaosarchitects.com

I A1
17
MATCHLINE

MEP CONSULTANT

PROJECT MANAGEMENT & SUPERVISION


M I D D

L
E E AS
T

CONTRACTOR
Al Saad General ContractinG Limited Liability Co.

P.O. Box 13028, Jeddah 21493, Saudi Arabia


P.O. Box 16910, Riyadh 11474, Saudi Arabia

JOB NUMBER

2013-154
PROJECT NAME

ZAHID BUSINESS PARK

LOCATION: PLOT NUMBER


JEDDAH KSA
1. All exhaust grill location and sizes should be as per approved MEP DESIGN BY -

composite layout. ARCHITECT TK


STRUCTURAL ENGINEER MF
2. Submit separate HVAC layout for Mechanical and Pump room. ELECTROMECHANICAL ENGINEER RM
3. Exhaust fan locations, capacities, duct sizes and pressure losses DRAWN: KS

should be as per IFC drawings and equipment schedule. CHECKED:


DESIGN PHASE
-

4. Fire dampers to be provided in the main duct while all branches to be CONSTRUCTION PHASE CP
equipped with VD. REVISION NUMBER
5. Coordination with other disciplines is contractor's responsibility. REVIEW CYCLE: 001
FORMAT SCALE DATE

CODE B A0 1:100 FEB.18.2020


DRAWING TITLE AND NUMBER

HEADQUARTERS
BASEMENT FLOOR PLAN
HVAC SYSTEM LAYOUT-PART-3
SECTION - H SECTION - I SECTION - D
TRANSMITTAL #: DRAWING NUMBER
ZBP-V3-ALSAAD-HQ-DWG-SD-MC-016-REV-1 ZBP/HQ/SD/M1A-101C
SIZE A0 841MM x 1189MM
GENERAL NOTES

A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1
Y X W V U T' T S R Q P' P

A1
A1 MATCHLINE
7

FFL -2.85 LEGEND:

A1
8
PARKING PARKING
BF.01 FFL -2.85 BF.01

F
FFL -2.70

A1
9
SUMP PIT 03
BF.43

A1
10
A1 B.O.PIT -4.95
10'

FFL -2.05
KEYPLAN:

FFL -2.85 A1
Y
A1
X
A1
W
A1
V
A1
U
A1 A1
T' T
A1
S
A1
R
A1
Q
A1 A1
P' P
A1
O
A1
N
A1
M
A1
L
A1 A1
K J
A1
I
A1
H
A1 A1
G G'
A1
F
A1
E
A1
D
A1
C
A1
B
A1
A

A1
1

A1
2"
A1
2

A1
3

A1
4

UP

PART-1 PART-2 FE1


A1
5

PE7
A1

A1
6

A1
7

A1
8

11 A1
9

A1
10
A1

PE4

PE1
10'

PE5

PE2
PE6

PE3
A1
11

PART-4 PART-3
A1
12
A1
13

A1
14
UP

A1
15

A1
16

A1
17

A1
12
FAN ROOM 04
BF.38 FAN ROOM 03
A1 EF-1A

FLAKTWOODS
BF.35
FLAKTWOODS
EF-1A

13
FFL -2.70
FFL -1.85

A1
14
FFL -2.70

UP
1
2
3
4
5
6
STO. 14
BF.40
NAME:
STAIR 05 SIGNATURE/
BF.39 DATE:

A Approved As Submitted D Disapproved


A1 Approved as Noted
15 B E No Action Taken
Resubmission not required
C Resubmission required

FFL -2.70
FFL -2.05
FFL -2.85
RAMP

18-02-2020 01 CONSULTANT COMMENTS INCORPORATED


FFL -2.85 26-01-2020 00 ISSUED FOR APPROVAL
DATE REVISION NO. REMARKS
FFL -2.70
CLIENT

A1
16
UP [T] +966 26681765
1 [F] +966 26681732
2 STORAGE 13 STORAGE 12 P.O. Box 3896 - Jeddah 21481
3 BF.37 BF.36 ARCHITECTS & INTERIORS [E] info@kaosarchitects.com
4
5
6 FAN ROOM 05
BF.41 FFL -1.85
STAIR 06 FFL -2.70
FFL -2.70
FLAKTWOODS

BF.42
EF-1A

MEP CONSULTANT
A1
17

MATCHLINE
PROJECT MANAGEMENT & SUPERVISION
M I D D

L
E E AS
T

CONTRACTOR
Al Saad General ContractinG Limited Liability Co.

P.O. Box 13028, Jeddah 21493, Saudi Arabia


P.O. Box 16910, Riyadh 11474, Saudi Arabia

JOB NUMBER

2013-154
PROJECT NAME

ZAHID BUSINESS PARK

LOCATION: PLOT NUMBER


JEDDAH KSA
DESIGN BY -
1. All exhaust grill location and sizes should be as per ARCHITECT TK

approved MEP composite layout. STRUCTURAL ENGINEER MF


ELECTROMECHANICAL ENGINEER RM
2. Submit separate HVAC layout for Mechanical and DRAWN: KS
Pump room. CHECKED: -

3. Exhaust fan locations, capacities, duct sizes and DESIGN PHASE


CONSTRUCTION PHASE CP
pressure losses should be as per IFC drawings and REVISION NUMBER
equipment schedule. REVIEW CYCLE: 001
4. Fire dampers to be provided in the main duct while FORMAT SCALE DATE
all branches to be equipped with VD. A0 1:100 FEB.18.2020

5. Coordination with other disciplines is contractor's DRAWING TITLE AND NUMBER

responsibility. HEADQUARTERS
BASEMENT FLOOR PLAN
SECTION - F CODE B HVAC SYSTEM LAYOUT-PART-4