The M200E-PMB panel mount bracket M701-240-DIN - 195g M701-240 Single 230Vac output
offers the ability to mount a single unit inc. surface
M200E-SMB: 139 (w) x 134 (h) x
module in to a suitable box by using mount box
40 (d).
two M4 pan head screws.
M701-240-DIN Single 230Vac output
• Current Consumption
Alternatively the M200E-DIN may be unit inc. DIN rail
used. This mounting option allows a ü M710, M701 - 310 µA @ 24 VDC mounting enclosure
single module to be mounted directly (without communication);
510 µA @ 24 VDC (one Mounting Accessories:
to a section of standard DIN rail.
communication every 5 sec.
with LED blink enabled). M200E-SMB Surface Mount Box
Maximum input circuit length is
approximately 750 metres or 2500 feet M200E-PMB Panel Mount Bracket
ü M720 - 340 µA @ 24 VDC
(20 Ohms maximum). (without communication); M200E-DIN DIN rail mounting clip
600 µA @ 24 VDC (one
A 47K End-of-Line Resistor (provided)
communication every 5 sec.
must be fitted to the Monitored circuits with LED blink enabled).
to provide supervision.
ü M721 - 340 µA @ 24 VDC
Mounting hardware and installation (without communication); 660
instructions are provided with each µA @ 24 VDC (one
module. communication every 5 sec.
with LED blink enabled).
ü 0% to 95%, non-condensing
relative humidity.
M701-240-DIN
Page 2 of 5 — 990-084
Back
Wiring Diagrams
Notes:
1 If short circuit isolation is not required, loop output+
should be wired to terminal 5 and not 2. Terminal 5 is
internally connected to terminal 4.
Loop Output -
1
2 The dashed line circuit connected to terminals 8 and 9
Loop Output +
2
should only be used with the M720. There are no
Loop Input -
3
connections to these terminals on the M710.
Loop Input + 3 Provided the control panel is compatible, short circuit
4
A B
Loop Output (See notes 1) + M710 / M720 monitoring of the input circuit may be possible. An
5
1
18K Ohm resistor should be wired in series with each
6
device switch being monitored.
7
0
8
9
12 11 10 4 5 4 5
3 6 3 6
2 7 2 7
1 8 1 8
0 9 0 9
A x10 B x1 C
47KΩ 47KΩ
See Note 2
Notes:
1 If short circuit isolation is not required, loop output+
should be wired to terminal 5 and not 2. Terminal 5 is
Loop Output - internally connected to terminal 4.
1
1
6
7
0
8
12 11 10 9
4 5 4 5
3 6 3 6
2 7 2 7
1 8 1 8
0 9 0 9
A x10 B x1 C
47KΩ 47KΩ
NC C NO
Relay Contact Rating:
30VDC, 2A resistive load
Loop Output -
1
Loop Output+
2
Loop Input -
3
Loop Input +
4
M700X
5
6
7
8
12 11 10 9
Page 3 of 5 — 990-084
Back
Wiring Diagrams
1
Loop Output+ internally connected to terminal 4.
2
2 To enable output circuit supervision, the link supplied
Loop Input-
3
must be fitted across terminals 6 and 7, and the load
Loop Input +
4
M701 A B must be polarised.
Loop Output (See notes 1) +
5
1 3 In supervised mode, the module monitors the power
6
supply voltage across terminals 10 and 11 to ensure it
does not drop below 7V, and also monitors for a
7
- 0
switched negative fault signal from the power supply to
8
terminal 12 (optional). If a fault is seen the yellow LED
12 11 10 9
+ will blink, and a fault may be indicated at the panel.
4 5 4 5 The use of this fault warning is dependant upon panel
3 3
6 6 software, please consult Notifier Technical support.
2 7 2 7 4 Up to 1.5A load can be driven subject to the supply
1 8 1 8 capability, total cable resistance and minimum voltage
0 9 0 9
+ - required by the load.
A x10 B x1 C
5 An alternative end of line monitoring option is available
for VdS 2489 requirements - see table 1. Maximum
External Power Supply cable series resistance is 10R so max. load current is
Maximum 32VDC, Table 1: EOL Monitoring Options limited by permissible voltage drop along the cable,
Minimum 7VDC Mode Switch A Switch B EOL Device Load min. PSU voltage and min. load voltage requirement.
EOL See Note 3 Position Position eg: Min PSU voltage = 21V, min load voltage = 18V,
Std 0 0 47KO Resistor See Note 4 max. series resistance = 10R, therefore max. current =
VdS 1 0 Polarised 47 O See Note 5 300mA [(21-18)/10 Amps.]
RLY N/A 1 Unsupervised
Notes:
1 If short circuit isolation is not required, loop output+
should be wired to terminal 5 and not 2. Terminal 5 is
- internally connected to terminal 4.
1
Loop Output
+
2
Loop Output
-
3
Loop Input
+
4
Loop Input A B
+ M701
5
{
6
7
Rating: C
12 11 10 9
30VDC, 2A
resistive load
N.O 4 5 4 5
3 6 3 6
2 7 2 7
1 8 1 8
0 9 0 9
A x10 B x1 C
Notes:
1. If short circuit isolation is not required, then the
N/O Input 1 7 1 Loop -, Out
loop output should be wired to terminal 5 rather
N/C Input 2 8 2 Loop +, Out - See Note 1 than terminal 2. Terminal 5 is internally connected
Ground 9 3 Loop -, In directly to terminal 4.
Page 4 of 5 — 990-084
Back
Mechanical
76mm
134mm
125mm
139mm
40mm
48mm
139mm
24mm
Page 5 of 5 — 990-084