Tank Inspection Report

Client: MB

Location: MB

Tank ID: TK-6000

Inspection Date: 23-12-2021

1/17
Tank Floor Layout
Showing Top and
Bottom Discontinuities

Tank TK-6000

Location MB

Client MB

Operator Company MB

Outer Tank Diameter17670 mm

Lower Threshold 60%

Upper Threshold 100%

Defect Enhancment 10
Setting

Discontinuity Colour Scheme

60% - 69%
70% - 79%
80% - 89%
90% - 100%
Weld Discontinuity
2/17
Maximum Discontinuity
Per Track

Tank TK-6000

Location MB

Client MB

Operator Company MB

Outer Tank Diameter17670 mm

Lower Threshold 60%

Upper Threshold 100%

Defect Enhancment 10
Setting

Discontinuity Colour Scheme

60% - 69%
70% - 79%
80% - 89%
90% - 100%
Weld Discontinuity
3/17
Tank Floor Numbering
System

Tank TK-6000

Location MB

Client MB

Operator Company MB

Outer Tank Diameter17670 mm

Lower Threshold 60%

Upper Threshold 100%

Defect Enhancment 10
Setting

4/17
Tank Floor Layout With
Symbols

Tank TK-6000

Location MB

Client MB

Operator Company MB

Outer Tank Diameter17670 mm

Lower Threshold 60%

Upper Threshold 100%

Defect Enhancment 10
Setting

5/17
Identify Top and
Bottom Discontinuities

Tank TK-6000

Location MB

Client MB

Operator Company MB

Outer Tank Diameter17670 mm

Lower Threshold 60%

Upper Threshold 100%

Defect Enhancment 10
Setting

Identify Top/Bottom Colour Scheme

Top

Bottom

Both

6/17
7/17

Plate summary
Tank: TK-6000
Date: 23-12-2021

0 10 20 30 40 50 60 70 80 90 100

Discontinuities found on all plates (ignoring thresholds)

Row Plate Minimum discontinuity % Maximum discontinuity % Severity


1 1 20 0
1 2 20 0
2 1 20 0
2 2 20 0
2 3 20 0
2 4 20 0
2 5 20 0
2 6 20 0
3 1 20 71
3 2 20 70
4 1 20 64
4 2 20 0
4 3 20 62
5 1 20 73
5 2 20 0
6 1 20 65
6 2 20 70
7 1 20 61
7 2 20 78

Total number Of plates for Tank TK-6000 = 19


8/17

Patch plate summary


Tank: TK-6000
Date: 23-12-2021

All X and Y coordinates are taken perpendicular from the plate reference to the TOP-LEFT corner of
the patch plate concerened. See each plate illustration for further details

METRIC (mm), Height and Width are rounded up to nearest 10 mm

Row Plate Plate Ref. Patch ID X Y Height Width Rot (deg) Radius Type

Total No Of Patches for Tank TK-6000 = 0


Total area of patch material required for Tank TK-6000 = 0 meters squared
9/17

UT verification summary
Tank: TK-6000
Date: 23-12-2021

All X and Y coordinates are taken perpendicular from the plate reference to the TOP-LEFT corner of
the verification area concerened. See each plate illustration for further details

Row/ Plate Ref. X, Y (mm) Length, Comment Date Added Remaining Wall/ Date Modified
Plate/ Width (mm) Measured Depth
Index

3/1/1 Bottom-Right 2191, 2147 70, 120 30-12-2021 Not validated


3/1/2 Bottom-Right 1560, 1829 70, 40 30-12-2021 Not validated
3/1/3 Bottom-Right 1387, 1827 90, 40 30-12-2021 Not validated
3/1/4 Bottom-Right 1558, 1249 110, 70 30-12-2021 Not validated
3/1/5 Bottom-Right 1384, 333 140, 70 30-12-2021 Not validated

3/2/1 Bottom-Left 8129, 2262 110, 100 30-12-2021 Not validated


3/2/2 Bottom-Left 6634, 2150 190, 170 30-12-2021 Not validated
3/2/3 Bottom-Left 7550, 132 120, 270 30-12-2021 Not validated

5/1/1 Top-Right 10960, -6 150, 280 30-12-2021 Not validated


5/1/2 Top-Right 9402, 40 150, 190 30-12-2021 Not validated
5/1/3 Top-Right 9112, 60 160, 140 30-12-2021 Not validated
5/1/4 Top-Right 9189, 137 290, 100 30-12-2021 Not validated
5/1/5 Top-Right 8746, 204 90, 100 30-12-2021 Not validated
5/1/6 Top-Right 7379, 29 140, 130 30-12-2021 Not validated
5/1/7 Top-Right 5542, 1 80, 160 30-12-2021 Not validated
5/1/8 Top-Right 3852, 591 120, 100 30-12-2021 Not validated
5/1/9 Top-Right 493, 591 90, 130 30-12-2021 Not validated
5/1/10 Top-Right 1487, 1162 130, 70 30-12-2021 Not validated
5/1/11 Top-Right 7495, 874 100, 130 30-12-2021 Not validated
5/1/12 Top-Right 10989, 591 110, 140 30-12-2021 Not validated
5/1/13 Top-Right 9465, 1579 120, 110 30-12-2021 Not validated
5/1/14 Top-Right 8984, 1602 120, 100 30-12-2021 Not validated
5/1/15 Top-Right 2939, 1752 90, 140 30-12-2021 Not validated
5/1/16 Top-Right 5093, 1746 100, 90 30-12-2021 Not validated
5/1/17 Top-Right 5148, 2060 100, 110 30-12-2021 Not validated
5/1/18 Top-Right 6127, 2072 110, 100 30-12-2021 Not validated
5/1/19 Top-Right 9869, 2086 180, 150 30-12-2021 Not validated

6/2/1 Top-Left 7446, 1727 130, 150 30-12-2021 Not validated


6/2/2 Top-Left 6045, 2000 140, 150 30-12-2021 Not validated
6/2/3 Top-Left 3988, 1731 170, 190 30-12-2021 Not validated
6/2/4 Top-Left 2050, 1403 160, 140 30-12-2021 Not validated

7/1/1 Top-Right 4714, -9 110, 150 30-12-2021 Not validated


7/1/2 Top-Right 4090, -7 110, 140 30-12-2021 Not validated

7/2/1 Top-Left 5175, 368 120, 120 30-12-2021 Not validated


7/2/2 Top-Left 5220, 574 60, 80 30-12-2021 Not validated
7/2/3 Top-Left 3097, 897 110, 110 30-12-2021 Not validated
7/2/4 Top-Left 3089, 1462 60, 50 30-12-2021 Not validated
7/2/5 Top-Left 3011, 1447 70, 70 30-12-2021 Not validated
7/2/6 Top-Left 2782, 1390 170, 120 30-12-2021 Not validated
7/2/7 Top-Left 269, 2213 180, 150 30-12-2021 Not validated
10/17

UT verification summary
Tank: TK-6000
Date: 23-12-2021

All X and Y coordinates are taken perpendicular from the plate reference to the TOP-LEFT corner of
the verification area concerened. See each plate illustration for further details

Row/ Plate Ref. X, Y (mm) Length, Comment Date Added Remaining Wall/ Date Modified
Plate/ Width (mm) Measured Depth
Index
11/17

UT verification summary
Tank: TK-6000
Date: 23-12-2021

All X and Y coordinates are taken perpendicular from the plate reference to the TOP-LEFT corner of
the verification area concerened. See each plate illustration for further details

Annular Plate Ref. X, Y (mm) Length, Comment Date Added Remaining Wall/ Date Modified
Width (mm) Measured Depth
5500mm 5000mm 4500mm 4000mm 3500mm 3000mm 2500mm 2000mm 1500mm 1000mm 500mm 0mm

2000mm

1500mm

1000mm

500mm

0mm
Y-axis

X-axis
Row: 3 Plate: 1
Plate Length (mm): 5630 Plate Width (mm): 2430
Orientation: Horizontal Scan Method: Parallel
Max discontinuity: 71 Showing defects from:TOP & BOTTOM
Lower Threshold: 60% Upper Threshold: 100% (Import Threshold:20%)
Defect enhancment setting: Not used
Discontinuity Colour Scheme Symbols
Tank: TK-6000 Operator: JORGE BARBOZA
Track Date: 23-12-2021 Equipment Serial: C90000004A48E322
60% - 69%
Non-Scanned Area Location: MB
70% - 79%
80% - 89%
Plate Reference
Company: MB
Tank Reference
90% - 100%
Weld Discontinuity Client: MB 12/17
0mm 500mm 1000mm 1500mm 2000mm 2500mm 3000mm 3500mm 4000mm 4500mm 5000mm 5500mm 6000mm 6500mm 7000mm 7500mm 8000mm 8500mm 9000mm 9500mm 10000mm10500mm11000mm11500mm

2000mm

1500mm

1000mm

500mm

0mm
Y-axis

X-axis
Row: 3 Plate: 2
Plate Length (mm): 11770 Plate Width (mm): 2430
Orientation: Horizontal Scan Method: Parallel
Max discontinuity: 70 Showing defects from:TOP & BOTTOM
Lower Threshold: 60% Upper Threshold: 100% (Import Threshold:20%)
Defect enhancment setting: Not used
Discontinuity Colour Scheme Symbols
Tank: TK-6000 Operator: JORGE BARBOZA
Track Date: 23-12-2021 Equipment Serial: C90000004A48E322
60% - 69%
Non-Scanned Area Location: MB
70% - 79%
80% - 89%
Plate Reference
Company: MB
Tank Reference
90% - 100%
Weld Discontinuity Client: MB 13/17
12000mm11500mm11000mm10500mm10000mm9500mm 9000mm 8500mm 8000mm 7500mm 7000mm 6500mm 6000mm 5500mm 5000mm 4500mm 4000mm 3500mm 3000mm 2500mm 2000mm 1500mm 1000mm 500mm 0mm

0mm

500mm

1000mm

1500mm

2000mm
Y-axis

X-axis
Row: 5 Plate: 1
Plate Length (mm): 12000 Plate Width (mm): 2430
Orientation: Horizontal Scan Method: Parallel
Max discontinuity: 73 Showing defects from:TOP & BOTTOM
Lower Threshold: 60% Upper Threshold: 100% (Import Threshold:20%)
Defect enhancment setting: Not used
Discontinuity Colour Scheme Symbols
Tank: TK-6000 Operator: JORGE BARBOZA
Track Date: 23-12-2021 Equipment Serial: C90000004A48E322
60% - 69%
Non-Scanned Area Location: MB
70% - 79%
80% - 89%
Plate Reference
Company: MB
Tank Reference
90% - 100%
Weld Discontinuity Client: MB 14/17
0mm 500mm 1000mm 1500mm 2000mm 2500mm 3000mm 3500mm 4000mm 4500mm 5000mm 5500mm 6000mm 6500mm 7000mm 7500mm 8000mm 8500mm 9000mm 9500mm 10000mm10500mm11000mm11500mm

0mm

500mm

1000mm

1500mm

2000mm
Y-axis

X-axis
Row: 6 Plate: 2
Plate Length (mm): 11750 Plate Width (mm): 2430
Orientation: Horizontal Scan Method: Parallel
Max discontinuity: 70 Showing defects from:TOP & BOTTOM
Lower Threshold: 60% Upper Threshold: 100% (Import Threshold:20%)
Defect enhancment setting: Not used
Discontinuity Colour Scheme Symbols
Tank: TK-6000 Operator: JORGE BARBOZA
Track Date: 23-12-2021 Equipment Serial: C90000004A48E322
60% - 69%
Non-Scanned Area Location: MB
70% - 79%
80% - 89%
Plate Reference
Company: MB
Tank Reference
90% - 100%
Weld Discontinuity Client: MB 15/17
6000mm 5500mm 5000mm 4500mm 4000mm 3500mm 3000mm 2500mm 2000mm 1500mm 1000mm 500mm 0mm

0mm

500mm

1000mm

1500mm

2000mm
Y-axis

X-axis
Row: 7 Plate: 1
Plate Length (mm): 6450 Plate Width (mm): 2430
Orientation: Horizontal Scan Method: Parallel
Max discontinuity: 61 Showing defects from:TOP & BOTTOM
Lower Threshold: 60% Upper Threshold: 100% (Import Threshold:20%)
Defect enhancment setting: Not used
Discontinuity Colour Scheme Symbols
Tank: TK-6000 Operator: JORGE BARBOZA
Track Date: 23-12-2021 Equipment Serial: C90000004A48E322
60% - 69%
Non-Scanned Area Location: MB
70% - 79%
80% - 89%
Plate Reference
Company: MB
Tank Reference
90% - 100%
Weld Discontinuity Client: MB 16/17
0mm 500mm 1000mm 1500mm 2000mm 2500mm 3000mm 3500mm 4000mm 4500mm 5000mm 5500mm 6000mm

0mm

500mm

1000mm

1500mm

2000mm
Y-axis

X-axis
Row: 7 Plate: 2
Plate Length (mm): 6450 Plate Width (mm): 2430
Orientation: Horizontal Scan Method: Parallel
Max discontinuity: 78 Showing defects from:TOP & BOTTOM
Lower Threshold: 60% Upper Threshold: 100% (Import Threshold:20%)
Defect enhancment setting: Not used
Discontinuity Colour Scheme Symbols
Tank: TK-6000 Operator: JORGE BARBOZA
Track Date: 23-12-2021 Equipment Serial: C90000004A48E322
60% - 69%
Non-Scanned Area Location: MB
70% - 79%
80% - 89%
Plate Reference
Company: MB
Tank Reference
90% - 100%
Weld Discontinuity Client: MB 17/17